Ravas RVL RF User manual

USER MANUAL – RVL RF 1
USER MANUAL
RVL RF
We would like to inform you about the fact that this RAVAS product is 100% recyclable on the basis
that the parts are processed and disposed of in the right manner.
More information can be found on our website www.ravas.com.
Rev.20181008
Printing/typographical errors and model changes reserved

USER MANUAL – RVL RF 2
PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
If you have any queries concerning the duration and terms of the guarantee, please contact your
supplier. We would also refer you to our General Sale and Supply Conditions, which are available on
request.
The manufacturer accepts no liability for any damage or injury caused by failure to follow these
instructions, or from negligent operation or assembly, even if this is not expressly stated in this
instruction manual.
In light of our policy of continuous improvement, it is possible that details of the product may differ
from those described in this manual. For this reason, these instructions should only be treated as
guidelines for the installation of the relevant product. This manual has been com- piled with all due
care, but the manufacturer cannot be held responsible for any consequences of errors. All rights
are reserved and no part of this manual may be reproduced in any way.

USER MANUAL – RVL RF 3
Table of contents
page
1. Introduction 4
2. Warnings & Safety measures 4
3. System setup 5
3.1 Installing the indicator 5
3.2 Placing battery pack in the RVL RF 6
3.3 Switching on the RVL RF 6
3.4 Switching on indicator 7
3.5 Switching off the system 7
4. Changing the battery 8
4.1 Low battery indication RVL RF 8
4.2 Charge the battery pack of the RVL RF 8
4.3 Changing the batteries of the indicator 9
5. Use 10
5.1 Use (accurate weighing) 10
5.1.1 zero check before a weighing 11
5.2 Level correction 11
5.3 Establish Bluetooth communication and weigh! 12
5.4 Auto shut-off indicator 13
5.5 Indicator functions 14
5.6 Error messages 16
5.7 Gross / tare / net weight 17
6.8.1 Net weighing: automatic tare 17
6.8.2 Net weighing: manual tare PT 19
5.8 Adding and reset 22
5.9 Changing the time and date (on the printout) 23
5.10 KG-LB switch 26
5.11 User settings 27

USER MANUAL – RVL RF 4
IP65
1. Introduction
This manual describes the installation and use of the RVL RF. Read this manual carefully. The installer
must be informed of the contents of this manual. Follow the contents of the manual precisely. Always
do things in the correct order. This manual should be kept on a safe and dry place.
In case of damage or loss the user may request a new copy of the manual from RAVAS.
2. Warnings & Safety measures
When using the RVL RF, please observe the instructions and guidelines
contained in this manual carefully. Always perform each step in
sequence. If any of the instructions are not clear, please contact RAVAS.
- All safety regulations that apply to the truck remain valid and unchanged
- No weighing operations are allowed if any persons or objects are in the vicinity; around, under
or close to the load.
- RAVAS is not responsible for any physical harm done to the operator because of the presence
of the indicator in the cabin.
- Any modifications done to the system must be approved in writing by the supplier, prior to any
work being completed.
- It is the sole responsibility of the purchaser to train their own employees in the proper use and
maintenance of this equipment.
- Do not operate this unit unless you have been fully trained in its capabilities.
- Check the accuracy of the scale on a regular basis to prevent faulty readings.
- Only trained and authorized personnel are allowed to service the scale.
- Always follow the operating, maintenance and repair instructions of this truck and ask the
supplier when in doubt.
- RAVAS is not responsible for errors that occur due to incorrect weightings or inaccurate
scales.
Should you have any further questions after reading this manual then you can contact us at:
RAVAS Europe B.V.
Toepadweg 7
Postbus 2023
5300 CA Zaltbommel
Nederland
Phone: +31 (0)418-515220
Fax: +31 (0)418-515320
Internet: www.ravas.com
Changes reserved
READ
CAREFULLY
min -10°C
15°F
00
max 40°C
105°F

USER MANUAL – RVL RF 5
3
2
1
S13
1.
2.
S5
3.
System setup
3.1 Installing the indicator
Find a suitable position for the indicator:
1. at the cabin’s roof.
2. on the right side of the cabin, mounted onto a side-rail.
3. on the dashboard.
Installation of the indicator bracket & support
The indicator should be easy
to reach and read out!

USER MANUAL – RVL RF 6
3.2 Placing the battery pack in the RVL RF
1. Release the locking clip on the battery holder.
2. Click the battery pack into the battery holder.
3. Push the locking clip up to secure the battery pack.
3.3 Switching on the RVL RF
2. The blue LED on the
RVL RF will start blinking
automatically.
1. Switch on the RVL by pressing
the blue button on the
battery pack holder.

USER MANUAL – RVL RF 7
3.4 Switching on the indicator
3.5 Switching off the system
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
Start up the
indicator. Press
the on/off key.
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
5 sec.
1
Switch off the
indicator by
pressing the
on/off key for 3
seconds.
1
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
2
Weigh!

USER MANUAL – RVL RF 8
4
. Changing battery
4.1 Low battery indication RVL RF
Exchangeable battery pack supplies power to the RVL RF .
When the voltage level of the battery pack is running low, the low bat indicator will light up and “F1” will
start blinking in the display.
The blue LED on the bluetooth module will start blinking very slowly (twice every 10 sec). The RVL RF
will switch off automatically after 10 minutes.
4.2 Charge the rechargeable battery pack (option)
The system is equipped with a rechargeable battery pack and a smart charger. Charge the battery for
8 hours. This will prevent loss of battery capacity.
First position the battery pack inside the charger module, then plug the adaptor into the mains voltage.
Smart charger: When the battery is being charged, the red LED on the charger is lit. After at least 8
hours charging, the charger shuts off and the the batterypacks are completely full. The red LED turns
off and the green LED will illuminate.
FUNCTIONALITY BLUE LED
DURING POWERING ON ON for 5 sec.
FULL BATTERY Blink time interval
Working mode Once every 1,5 sec.
Sleep mode Once every 4 sec.
LOW BATTERY
Working mode Twice every 10 sec.
Sleep mode Twice every 10 sec.
Charger unit

USER MANUAL – RVL RF 9
Remove the battery cover of the indicator
housing by tightening the
screw counter-clockwise.
4.3 Changing the batteries of the indicator
The indicator is equipped with 4 AA batteries.
Remove the battery holder
and remove the empty batteries.
Place new batteries in
the battery holder and
place the battery holder
in the housing.
Close the battery cover of the
indicator housing and lock by partly
unscrew clockwise.
Replace batteries as soon as the
low bat indicator starts blinking.
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
Be sure the batteries are positioned
correctly. Watch for the polarity!
1.
2.
1. 2.
1.
2.
1.
2.
4 x AA
2 1
3 4
5

USER MANUAL – RVL RF 10
5. Use
5.1 Use (accurate weighing)
OK
0
max 40°C
105°F
min -10°C
15°F
0
M1
M1
3 - 5 min.
After 3 to 5 minutes the load cells have reached the
operational temperature. Don’t lift loads before the
zero-point correction has been executed.

USER MANUAL – RVL RF 11
a
OK
F2e2e1 e3 F1
Check the zero reading
before each weighing!
Before each weighing it is necessary
to check whether the system is
unloaded and free.
If the indicator does not determine
the zero point automatically, it must
be done manually using the >0< key.
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
5.1.1 Check the zero reading before each weighing
5.2 Level correction
NTEP: OK if α = +/- 5% ( 3˚)
OIML: OK if α = +/- 2˚
Legal for trade:
OK
> α

USER MANUAL – RVL RF 12
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
5.3 Establish Bluetooth communication and weigh!
Before each weighing: check the zero point!
Before each weighing it is necessary to check
whether the system is unloaded and free.
If the indicator does not determine the zero point
automatically, it must be done manually using the
>0< key.
Switch on the RVL RF:
press the blue button on the battery pack. Start up the indicator:
press the on/off key.
1000
2
3 4
1
5
System is ready to weigh.
6
5 sec.
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
Before the next weighing,
check the zero point again.

USER MANUAL – RVL RF 13
20 sec.
2 min.
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
5.4 Auto shut-off indicator
5
4
2 1
no action ! Countdown starts:
Press any key during
countdown to cancel
auto-shut-off and go
back to the weighing
mode.
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
Indicator off
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
3
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR

USER MANUAL – RVL RF 14
5.5 Indicator functions
Display Functions
the weighing system (including load) is stable
the weight shown is negative
ZERO the weight shown is within the zero range
NET the display is showing the net weight
e1 displayed weight is in range 1 (option multi range)
e2 displayed weight is in range 2 (option multi range)
e2 displayed weight is in range 3 (option multi range)
F1 Fork 1 / setpoint 1 is activated (option relay output)
kg displayed weight is in kilograms
lb displayed weight is in pounds
pcs number displayed represent number of pieces on the scale
low bat indicator
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
pcs
lb
kg

USER MANUAL – RVL RF 15
Key functions
Each key has 2 operational and one entry function.
Standard function Key Special function Value entering
(Short key press) (long key press) function (entry mode)
zero setting code entry
enter
automatic tare pre-set tare
decrease the value
of the digit flashing
print weight and add to check subtotal and print total
the total
increase the value of
the digit flashing
sampling a piece weight enter a piece weight
shift to the next digit
on the left
On switch Off switch
And change to lb and kg
clear entry
Important
Operation of a key is not accepted unless the weighing system is stable (and the “load stable” pointer
lights up). This means that the indicator only executes commands with a stable load.
For a detailed description of the function CODE ENTRY check our operational manual Indicator 3200 at
www.MyRAVAS.com.
ID CODE
PT
TOTAL
PCS
KG/LB
CLR

USER MANUAL – RVL RF 16
5.6 Error messages
ERRORMESSAGES
Display Meaning Outoferrormode
Err01 Loadcellsignalisunstable Automatic
Err02 Overloadonfullscale Automaticafterremovingweight
Err03 Grossnegative.Thisactionisnotallowed Automatic
Err04 Outofzerorange Pressanykey
Err05 Samplingaccuracytoolow Pressanykey
Err06 Inputsignaltoohigh Automaticaftercorrectinginput
Err08 Calibrationoutofrange(negative) Automatic
Err09 Calibrationoutofrange(signaltoolow) Automatic
Err10 Calibrationcount2nd(3rd)pointlowerthancount
1st(2nd)point
Automatic
Err14 Setpointvalue2<setpointvalue1.Thisisnotallowed Automatic
Err97
Err98
Legalfortradeversion:notallowedaction
Calibrationpointmustbehigherthanpreviousone
Whenactionisintended,installjumperJP1
(attention:afterthisactionacomplete
newcalibrationandstampingofthe
systemisnecessary)
Automatic
Err99
ErrF1
ErrF2
‐‐‐‐
L‐_
ErrCS
+F1
Actiononlyallowedinstart‐upunits
Problemwithfork1(nocommunication)
Problemwithfork2(nocommunication)
Loadcellsignalnegative
Forksareoutoflevel(onlylegal‐for‐tradeversion)
Problemwithcorrectionsensor
Batteryofindicatorisempty
Batteryoffork1isempty
Automatic
Restartindicator.Restartforks&indicator
Restartindicator.Restartforks&indicator
Liftuptheforksfromtheground
Puttheforksintohorizontalposition
ContacttheRAVASServicedepartment
Replacethe4AAbatteries
ReplacetheD‐cellsinbothbatterypacksor
chargebothbatterypacks
DISPLAYMESSAGES
Display Meaning
BltF1 SuccessfulBluetoothlinkwithfork1 Noerror

USER MANUAL – RVL RF 17
5.7 Net / Tare / Gross weight
EXPLANATION: Net(1) + Tare(2) = Gross(3)
5.7.1 Net weighing: automatic tare
2 1
3 4
The indicator is set to zero.
The “NET” pointer shows that
the tare weight is activated.
1 2 3
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR

USER MANUAL – RVL RF 18
5
7 8
9
The display shows the net value
of the weighed load.
The gross weight is displayed
again.
1000
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
6
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
1000
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR

USER MANUAL – RVL RF 19
3 sec.
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
5.7.2 Net weighing: manual tare (PT)
2 1
6
3 4
5
Press the
PT key for 3
seconds
Press the up
or down key
until the
desired
value is
reached.
5x
Press the up
or down key
until the
desired
value is
reached.
1x
1000
25
e1 e2 e3 F1 F2
NET
ID CODE PT TOT AL PCS KG/LB
CLR
Press ENTER
to activate the
tare weight.
2x

USER MANUAL – RVL RF 20
8 7
12
9 10
11
The “NET”pointer lights up
When the RVL RF are
completely unloaded, the
tare value is displayed
negatively.
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR 1000
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
e1 e2 e3 F1 F2
NET
ID CODE PT TOTAL PCS KG/LB
CLR
1000
Table of contents
Popular Tractor Accessories manuals by other brands

Wallenstein
Wallenstein LXG400 Series Operator's manual

Femco
Femco WEATHER-BRAKE 2145 instructions

McConnel
McConnel ECON Operations & parts manual

TOP DOG ATTACHMENTS
TOP DOG ATTACHMENTS SUMMIT TRACTORS ATTACHMENTS GX54 quick start guide

Howard
Howard HK32 Operating instructions & parts list

Duncan
Duncan Renovator AS3000 owner's manual

Avantco
Avantco A35870 Operator's manual for Attachment

Avantco
Avantco A453046 Operator's manual

Avantco
Avantco A446413 Operator's manual

Avantco
Avantco Collecting Broom 1500 Operator's manual for Attachment

Avantco
Avantco Backhoe 260 Operator's manual for Attachment

Avantco
Avantco A410224 Operator's manual for Attachment