manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Raynor
  6. •
  7. Garage Door Opener
  8. •
  9. Raynor 545RGD Safety Signal User manual

Raynor 545RGD Safety Signal User manual

To prevent possible SERIOUS INJURY or DEATH from electrocution:
• Be sure power is NOT connected BEFORE installing the receiver.
To prevent possible SERIOUS INJURY or DEATH from a moving gate
or garage door:
• ALWAYS keep remote controls out of reach of children. NEVER
permit children to operate or play with remote controls.
• Activate gate or door ONLY when it can be seen clearly, is properly
adjusted and there are no obstructions to door travel.
• ALWAYS keep gate or garage door in sight until completely closed.
NEVER permit anyone to cross path of moving gate or door.
WARNING
CAUTION
WARNING
WARNING
NOTICE TO U.S. CONSUMERS:
Some states prohibit the service or repair of garage door openers which
cannot be made to comply with the safety standards contained in UL 325
(1988 revision). In order to comply with both the letter and the spirit of
these laws, this universal radio control should not be used with any
LiftMaster®, Chamberlain®, or Sears Craftsman®garage door opener
manufactured prior to April 1, 1982. To find out if your
Chamberlain-made garage door opener was manufactured prior to or
after April 1, 1982, please call 1-800-528-9131 before installing this
universal radio control.
MOUNTING RECEIVER
• Unplug the opener before proceeding.
• Fully extend antenna wire below bottom of case as shown.
• The receiver can be mounted directly on the door opener with
the clips provided (Figure 1).
OR
• Attached to a ceiling/inside wall of the garage with connecting
bell wire (not provided). Fasten the receiver to the ceiling or
inside garage wall with dry wall screws provided (Figure 2).
NOTE: Transformer Model 85 or 95 is required if your residential
garage door opener is a LiftMaster, Chamberlain or Sears.
INSTALLATION USING CLIPS
Loosen the three terminal screws on the receiver (labeled 1, 2
and 3) (Figure 1). Insert one end of a mounting clip under each
terminal. Do not retighten at this time.
Loosen the three terminal screws on the opener used for push
button controls and radio power.
Leaving the push button bell wire in place, insert the other ends
of the mounting clips under the opener terminal screws.
NOTE: If the number sequence of opener terminals does not
match the receiver, turn the receiver around (so back is facing
out) and complete the connection.
Retighten the terminal screws on opener and receiver.
Reconnect power to the opener. The receiver push bar should
light. If it does not, use Transformer Model 85 or 95.
INSTALLATION USING BELL WIRE
Attach one end of 3-strand bell wire (not provided) to receiver
terminals 1, 2 and 3. Connect the other end to the three opener
terminals used for push button controls and radio power. Use
insulated staples to secure bell wire between receiver and opener
(Figure 2).
Reconnect power to the opener. The receiver push bar should
light. If it does not, use Transformer Model 85 or 95.
INSTALLATION WITH TRANSFORMER
With the transformer, use a 2-wire connection only. Attach wire to
receiver terminals 1 and 2 and to the opener terminals used for
push button control. Plug the transformer into receiver and 120
Volt outlet (Figure 3).
Antenna Wire Fully Extended
Radio Power
Push Button
Common
Opener
Terminals
Opener Terminals
1
2
3
Transformer 321
Antenna Wire
Fully Extended
Radio Power
Push Button
Common
123
Opener
Terminals
Figure 1
Figure 2
Figure 3
NOTE: Transformer Model 85 or 95 is required if your residential
garage door opener is a LiftMaster, Chamberlain or Sears.
Universal Radio Control
OWNER’S MANUAL
Model 545RGD Safety Signal™Receiver Only
Model 545-1RGD Safety Signal™
(With 1 Remote Control)
Model 545-2RGD Safety Signal™
(With 2 Remote Controls)
©2006 The Chamberlain Group, Inc.
114A2201C All Rights Reserved
PROGRAMMING THE REMOTE TO THE
RECEIVER
With Safety Signal™, the code between the remote control and
the receiver changes with each use, accessing over 100 billion
new codes.
You can activate your opener with up to 8 Safety Signal™
remote controls and one Safety Signal™ Keyless Entry.
1. Pry open the front panel of receiver case with a coin or a
screwdriver (Figure 4). Re-connect power to opener.
2. Press and release the “SMART” button on the receiver. The
“SMART” indicator light will glow steadily for 30 seconds
(Figure 5).
3. Within 30 seconds, press and hold the button on the
hand-held remote that you wish to operate your garage door
(Figure 6).
The opener will now operate when the push button on either the
receiver or the remote control is pressed.
Repeat Steps 2 and 3 for each remote control that will be used
to operate the garage door opener.
TO ERASE ALL REMOTE CONTROL CODES
Press and hold the “SMART” button on the receiver panel until
the indicator light turns off (about 6 seconds). All remote control
codes are now erased. Then follow the steps above to reprogram
each remote control.
REPLACING THE REMOTE
CONTROL BATTERY
The lithium battery should produce power
for up to 5 years. To replace battery, pry
open case with visor clip or screwdriver,
as shown. Insert battery positive side up.
Dispose of old battery properly.
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
WARNING
CAUTION WARNING
WARNING
3
2
1
Indicator
Light
“SMART”
Button
SPECIFICATIONS
Output Rating......................................5 Amps 28VAC or DC Max.
Power ....................................................18V - 30V ~, 30mA, 60Hz
18 - 30V , 30mA
RF Frequency....................................................................390MHz
If the power is other than shown in specifications, Accessory
Transformer Model 85 or 95 is required.
Accessory Remote Controls — Series 900.
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of
this receiver and/or remote control are prohibited, except for changing the code setting or
replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
Figure 5
Figure 6
Figure 4

Other manuals for 545RGD Safety Signal

1

This manual suits for next models

2

Other Raynor Garage Door Opener manuals

Raynor 3595RGD 3/4 HP User manual

Raynor

Raynor 3595RGD 3/4 HP User manual

Raynor Pilot 1265RGD User manual

Raynor

Raynor Pilot 1265RGD User manual

Raynor MJ5011UCHB User manual

Raynor

Raynor MJ5011UCHB User manual

Raynor Airman II 8155RGD User manual

Raynor

Raynor Airman II 8155RGD User manual

Raynor Safety signal 3220RGD User manual

Raynor

Raynor Safety signal 3220RGD User manual

Raynor 8165RGD CONTRACTOR Series Corporal II User manual

Raynor

Raynor 8165RGD CONTRACTOR Series Corporal II User manual

Raynor 3255RGD User manual

Raynor

Raynor 3255RGD User manual

Raynor 545RGD Safety Signal User manual

Raynor

Raynor 545RGD Safety Signal User manual

Raynor Navigator 2245RGD User manual

Raynor

Raynor Navigator 2245RGD User manual

Raynor MT5011UCHB User manual

Raynor

Raynor MT5011UCHB User manual

Raynor 3265RGDM 1/2 HP User manual

Raynor

Raynor 3265RGDM 1/2 HP User manual

Raynor Navigator 1245RGD User manual

Raynor

Raynor Navigator 1245RGD User manual

Raynor Aviator II PREMIUM Series Use and care manual

Raynor

Raynor Aviator II PREMIUM Series Use and care manual

Raynor 8550WRGD Admiral II User manual

Raynor

Raynor 8550WRGD Admiral II User manual

Raynor Sergeant II STANDARD Series User manual

Raynor

Raynor Sergeant II STANDARD Series User manual

Raynor Sergeant II Standard 8160WRGD User manual

Raynor

Raynor Sergeant II Standard 8160WRGD User manual

Raynor Safety Signal 3800RGD User manual

Raynor

Raynor Safety Signal 3800RGD User manual

Raynor 3280RGDM User manual

Raynor

Raynor 3280RGDM User manual

Raynor 87504RGD-267 User manual

Raynor

Raynor 87504RGD-267 User manual

Raynor COMMANDER 2000RGD User manual

Raynor

Raynor COMMANDER 2000RGD User manual

Raynor SENTINEL III 84505RRGD User manual

Raynor

Raynor SENTINEL III 84505RRGD User manual

Raynor 1280RGD User manual

Raynor

Raynor 1280RGD User manual

Raynor RapidCoil RC300 Series User manual

Raynor

Raynor RapidCoil RC300 Series User manual

Raynor CORPORAL II STANDARD Series User manual

Raynor

Raynor CORPORAL II STANDARD Series User manual

Popular Garage Door Opener manuals by other brands

Chamberlain B980 owner's manual

Chamberlain

Chamberlain B980 owner's manual

B&D Panelift B&D Storm-Shield PFI installation instructions

B&D

B&D Panelift B&D Storm-Shield PFI installation instructions

Automatic Technology NeoSlider TrioCode 128 NES-500 manual

Automatic Technology

Automatic Technology NeoSlider TrioCode 128 NES-500 manual

Lamp FD25SP installation manual

Lamp

Lamp FD25SP installation manual

CAME VLR01DX installation manual

CAME

CAME VLR01DX installation manual

Automatic Technology ATS Series instruction manual

Automatic Technology

Automatic Technology ATS Series instruction manual

FIRMADOOR Remote Control Operator installation instructions

FIRMADOOR

FIRMADOOR Remote Control Operator installation instructions

Seip TS Akku II Installation instruction

Seip

Seip TS Akku II Installation instruction

MyQ LiftMaster 84501 user guide

MyQ

MyQ LiftMaster 84501 user guide

FAAC 560 Series quick start guide

FAAC

FAAC 560 Series quick start guide

RIB AA33694 manual

RIB

RIB AA33694 manual

Chamberlain LM50 Assembly and operating instructions

Chamberlain

Chamberlain LM50 Assembly and operating instructions

Beninca DU.45E operating instructions

Beninca

Beninca DU.45E operating instructions

PPA GIRO user manual

PPA

PPA GIRO user manual

Johnson Controls HomeLink OHHL3 user manual

Johnson Controls

Johnson Controls HomeLink OHHL3 user manual

Centurion D2 Turbo Pocket installation guide

Centurion

Centurion D2 Turbo Pocket installation guide

Novoferm K8 Series Installation, operating and maintenance instructions

Novoferm

Novoferm K8 Series Installation, operating and maintenance instructions

IsoMatic 500 Instructions for fitting, operating and maintenance

IsoMatic

IsoMatic 500 Instructions for fitting, operating and maintenance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.