Reach Technology SLCD+ User manual

SLCD+ Controller Manual V1.1
August 14, 2009
For SLCD+ Hardware Revision A, RoHS Compliant
© Copyright Reach Technology Inc. 2003-2009
All Rights Reserved
Note: the software included with this product is subject to a license agreement as described in
this Manual.
Reach Technology, Inc.
www.reachtech.com
(510) 770-1417
SLCD+ Controller Manual V1.1 8/14/2009 Page 1

Table of Contents
0. HARDWARE LIMITED WARRANTY AND SOFTWARE LICENSE
AGREEMENT................................................................................................................ 5
0.1. HARDWARE LIMITED WARRANTY.................................................................................... 5
0.2. RETURNS AND REPAIR POLICY ......................................................................................... 5
0.3. SOFTWARE LICENSE AGREEMENT .................................................................................... 6
1. INTRODUCTION .......................................................................................................... 8
1.1. OVERVIEW ........................................................................................................................ 8
1.2. FEATURES ......................................................................................................................... 8
1.3. DIMENSIONS -REV GBOARD............................................................................................ 9
1.4. ELECTRICAL CHARACTERISTICS..................................................................................... 10
1.5. ENVIRONMENTAL............................................................................................................ 10
1.6. PANEL SUPPORT .............................................................................................................. 10
1.7. UPGRADE OPTIONS.......................................................................................................... 10
2. CONFIGURATION GUIDE ....................................................................................... 11
2.1. POWER ............................................................................................................................ 11
2.2. SERIAL ............................................................................................................................ 11
2.3. TFT PANEL ORIENTATION.............................................................................................. 11
2.4. GROUNDING.................................................................................................................... 11
3. CONNECTORS AND JUMPERS............................................................................... 12
3.1. J6 -POWER AND COM0 (RS232 COMMUNICATIONS MODE) .......................................... 12
3.2. J4 –COM2 RS232 PORT ................................................................................................. 13
3.3. J5 –POWER AND COM3 3.3V /5V PORT........................................................................ 13
3.4. J12 -4WIRE TOUCH ....................................................................................................... 14
3.5. J11 -4WIRE TOUCH ....................................................................................................... 14
3.6. J2A -4WIRE TOUCH*..................................................................................................... 14
3.7. J7 -20 PIN 0.5MM FLAT FLEX LCD CONNECTOR ........................................................... 15
3.8. J8 -16 PIN 1MM FLAT FLEX LCD CONNECTOR .............................................................. 15
3.9. J9 -33 PIN 0.5MM FLAT FLEX LCD CONNECTOR ........................................................... 15
3.10. J10 -BACKLIGHT /INVERTER CONTROL ..................................................................... 16
3.11. JP1 –COM1 /PROGRAMMING HEADER..................................................................... 16
4. SYSTEM OVERVIEW ................................................................................................ 17
4.1. GENERAL SLCD+ CONTROLLER .................................................................................... 17
4.2. OVERVIEW -SLCD+ EVALUATION KITS........................................................................ 17
4.2.1. GETTING STARTED ...................................................................................................... 17
4.2.2. CONNECTING THE KIT TO A PC.................................................................................... 17
4.2.3. DEVELOPING THE APPLICATION GUI WITH AN EMBEDDED CONTROLLER AS HOST.... 18
4.3. POWERCOM4BOARD...................................................................................................... 19
4.4. POWERCOM4SCHEMATIC .............................................................................................. 20
4.5. KIT /POWERCOM4OPERATIONAL NOTES...................................................................... 21
4.6. COMMUNICATIONS INTERFACE....................................................................................... 22
General........................................................................................................................... 22
4.7. LED INDICATORS............................................................................................................ 22
5. SOFTWARE COMMAND REFERENCE................................................................. 23
SLCD+ Controller Manual V1.1 8/14/2009 Page 2

APPENDIX A - PANELS COMPATIBLE WITH THE SLCD+ CONTROLLER .............. 24
A.1 HITACHI SX14Q001[-ZZA] AND SX14Q004[-ZZA] ..................................................... 24
A.2 HITACHI TX14D11VM1CAA-1 (CBA W/O TOUCH)...................................................... 24
A.3 COLOR 5.7" CSTN KYOCERA KCG057QV1DC-G50 .................................................... 24
A.4 COLOR 5.7" TFT KYOCERA TCG057QV1AB-G00 OR TCG057QV1AA-G00 .............. 24
A.5 COLOR 5.5" TFT NEC NL3224BC35-20........................................................................ 24
A.6 COLOR 5.7" CSTN OPTREX F-51900NFU-FW-AC........................................................ 24
A.7 COLOR 5.7" TFT SHARP LQ057Q3DC02....................................................................... 25
A.8 COLOR TFT SHARP SMALL ............................................................................................. 25
APPENDIX B - PARTS AND SUPPLIERS FOR SLCD+ CONTROLLER CONNECTIONS
........................................................................................................................................ 26
B.1 CONNECTORS AND CABLES FOR J6, J10.......................................................................... 26
B.2 CABLES FOR J7, J9 .......................................................................................................... 26
B.3 DISCRETE WIRE CABLE VENDORS ................................................................................... 26
APPENDIX C - ORDERING INFORMATION....................................................................... 27
C.1 CONTACT REACH DIRECTLY FOR ORDERING INFORMATION........................................... 27
APPENDIX D - TROUBLESHOOTING.................................................................................. 28
D.1 TOUCH UNRELIABLE OR NON-OPERATIVE....................................................................... 28
D.2 COLOR STN (PASSIVE)DISPLAY LOOKS TOO DARK,TEXT IS BLUE INSTEAD OF BLACK.28
APPENDIX E – USING COM0 / J6 FOR 3.3V CMOS INTERFACE................................... 29
COM0 Logic Level Mode: ............................................................................................. 29
SLCD+ Controller Manual V1.1 8/14/2009 Page 3

Figures
FIGURE 1: REV GBOARD PHYSICAL DIMENSIONS (INCHES)............................................................................ 9
FIGURE 2: CONNECTORS AND JUMPERS (J11 NOT INSTALLED) ...................................................................... 12
SLCD+ Controller Manual V1.1 8/14/2009 Page 4

0. Hardware Limited Warranty and Software License
Agreement
0.1. Hardware Limited Warranty
REACH TECHNOLOGY, Inc. warrants its hardware products to be free from
manufacturing defects in materials and workmanship under normal use for a period of one
(1) year from the date of purchase from REACH. This warranty extends to products
purchased directly from REACH or an authorized REACH distributor. Purchasers should
inquire of the distributor regarding the nature and extent of the distributor's warranty, if
any. REACH shall not be liable to honor the terms of this warranty if the product has been
used in any application other than that for which it was intended, or if it has been subjected
to misuse, accidental damage, modification, or improper installation procedures.
Furthermore, this warranty does not cover any product that has had the serial number
altered, defaced, or removed. This warranty shall be the sole and exclusive remedy to the
original purchaser. In no event shall REACH be liable for incidental or consequential
damages of any kind (property or economic damages inclusive) arising from the sale or use
of this equipment. REACH is not liable for any claim made by a third party or made by the
purchaser for a third party. REACH shall, at its option, repair or replace any product found
defective, without charge for parts or labor. Repaired or replaced equipment and parts
supplied under this warranty shall be covered only by the unexpired portion of the
warranty. Except as expressly set forth in this warranty, REACH makes no other
warranties, expressed or implied, nor authorizes any other party to offer any warranty,
including any implied warranties of merchantability or fitness for a particular purpose. Any
implied warranties that may be imposed by law are limited to the terms of this limited
warranty. This warranty statement supercedes all previous warranties, and covers only the
Reach hardware. The unit's software is covered by a separate license agreement.
0.2. Returns and Repair Policy
No merchandise may be returned for credit, exchange, or service without prior
authorization from REACH. To obtain warranty service, contact the factory and request an
RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of
the problem, name and phone number of contact person, RMA number, and return address.
Authorized returns must be shipped freight prepaid to Reach Technology Inc. 4575
Cushing Parkway, Fremont, California 94538 with the RMA number clearly marked on the
outside of all cartons. Shipments arriving freight collect or without an RMA number shall
be subject to refusal. REACH reserves the right in its sole and absolute discretion to charge
a 15% restocking fee, plus shipping costs, on any products returned with an RMA.
Return freight charges following repair of items under warranty shall be paid by REACH,
shipping by standard ground carrier. In the event repairs are found to be non-warranty,
return freight costs shall be paid by the purchaser.
SLCD+ Controller Manual V1.1 8/14/2009 Page 5

0.3. Software License Agreement
PLEASE READ THIS SOFTWARE LICENSE AGREEMENT CAREFULLY BEFORE
DOWNLOADING OR USING THE SOFTWARE .
This License Agreement (“Agreement”) is a legal contract between you (either an individual or a
single business entity) and Reach Technology Inc. (“Reach”) for software referenced in this
guide, which includes computer software and, as applicable, associated media, printed materials,
and “online” or electronic documentation (the “Software”).
BY INSTALLING, COPYING, OR OTHERWISE USING THE SOFTWARE, YOU AGREE
TO BE BOUND BY THE TERMS OF THIS AGREEMENT. IF YOU DO NOT AGREE TO
THE TERMS OF THIS AGREEMENT, DO NOT INSTALL OR USE THE SOFTWARE. IF
YOU HAVE PAID A FEE FOR THIS LICENSE AND DO NOT ACCEPT THE TERMS OF
THIS AGREEMENT, REACH WILL REFUND THE FEE TO YOU PROVIDED YOU (1) DO
NOT INSTALL THE SOFTWARE AND (2) RETURN ALL SOFTWARE, MEDIA AND
OTHER DOCUMENTATION AND MATERIALS PROVIDED WITH THE SOFTWARE TO
REACH TECHNOLOGY INC AT: REACH TECHNOLOGY INC., 4575 CUSHING
PARKWAY, FREMONT, CALIFORNIA 94538.
Reach Technology Inc. ("Reach") and its suppliers grant to Customer ("Customer") a
nonexclusive and nontransferable license to use the Reach software ("Software") in object code
form on one or more central processing units owned or leased by Customer or otherwise
embedded in equipment provided by Reach.
EXCEPT AS EXPRESSLY AUTHORIZED ABOVE, CUSTOMER SHALL NOT: COPY, IN
WHOLE OR IN PART, SOFTWARE OR DOCUMENTATION; MODIFY THE SOFTWARE;
REVERSE COMPILE OR REVERSE ASSEMBLE ALL OR ANY PORTION OF THE
SOFTWARE; OR RENT, LEASE, DISTRIBUTE, SELL, OR CREATE DERIVATIVE WORKS
OF THE SOFTWARE.
Customer agrees that aspects of the licensed materials, including the specific design and structure
of individual programs, constitute trade secrets and/or copyrighted material of Reach. Customer
agrees not to disclose, provide, or otherwise make available such trade secrets or copyrighted
material in any form to any third party without the prior written consent of Reach. Customer
agrees to implement reasonable security measures to protect such trade secrets and copyrighted
material. Title to Software and documentation shall remain solely with Reach.
SOFTWARE LIMITED WARRANTY. Reach warrants that for a period of ninety (90) days from
the date of shipment from Reach: (i) the media on which the Software is furnished will be free of
defects in materials and workmanship under normal use; and (ii) the Software substantially
conforms to its published specifications. Except for the foregoing, the Software is provided AS
IS. This limited warranty extends only to Customer as the original licensee. Customer's exclusive
remedy and the entire liability of Reach and its suppliers under this limited warranty will be, at
Reach's option, repair, replacement, or refund of the Software. In no event does Reach warrant
that the Software is error free or that Customer will be able to operate the Software without
problems or interruptions.
SLCD+ Controller Manual V1.1 8/14/2009 Page 6

This warranty does not apply if the software (a) has been altered, except by Reach, (b) has not
been installed, operated, repaired, or maintained in accordance with instructions supplied by
Reach, (c) has been subjected to abnormal physical or electrical stress, misuse, negligence, or
accident, or (d) is used in ultrahazardous activities.
DISCLAIMER. EXCEPT AS SPECIFIED IN THIS WARRANTY, ALL EXPRESS OR
IMPLIED CONDITIONS, REPRESENTATIONS, AND WARRANTIES INCLUDING,
WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, NONINFRINGEMENT OR ARISING FROM A
COURSE OF DEALING, USAGE, OR TRADE PRACTICE, ARE HEREBY EXCLUDED TO
THE EXTENT ALLOWED BY APPLICABLE LAW.
IN NO EVENT WILL REACH OR ITS SUPPLIERS BE LIABLE FOR ANY LOST
REVENUE, ROFIT, OR DATA, OR FOR SPECIAL, INDIRECT, CONSEQUENTIAL,
INCIDENTAL, OR PUNITIVE DAMAGES HOWEVER CAUSED AND REGARDLESS OF
THE THEORY OF LIABILITY ARISING OUT OF THE USE OF OR INABILITY TO USE
THE SOFTWARE EVEN IF REACH OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES.
In no event shall Reach's or its suppliers' liability to Customer, whether in contract, tort
(including negligence), or otherwise, exceed the price paid by Customer. The foregoing
limitations shall apply even if the above-stated warranty fails of its essential purpose. SOME
STATES DO NOT ALLOW LIMITATION OR EXCLUSION OF LIABILITY FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES.
The above warranty DOES NOT apply to any beta software, any software made available for
testing or demonstration purposes, any temporary software modules or any software for which
Reach does not receive a license fee. All such software products are provided AS IS without any
warranty whatsoever.
This License is effective until terminated. Customer may terminate this License at any time by
destroying all copies of Software including any documentation. This License will terminate
immediately without notice from Reach if Customer fails to comply with any provision of this
License. Upon termination, Customer must destroy all copies of Software.
Software, including technical data, is subject to U.S. export control laws, including the U.S.
Export Administration Act and its associated regulations, and may be subject to export or import
regulations in other countries. Customer agrees to comply strictly with all such regulations and
acknowledges that it has the responsibility to obtain licenses to export, re-export, or import
Software.
This License shall be governed by and construed in accordance with the laws of the State of
California, United States of America, as if performed wholly within the state and without giving
effect to the principles of conflict of law. If any portion hereof is found to be void or
unenforceable, the remaining provisions of this License shall remain in full force and effect. This
License constitutes the entire License between the parties with respect to the use of the Software.
SLCD+ Controller Manual V1.1 8/14/2009 Page 7

1. Introduction
1.1. Overview
The SLCD+ controller provides complete Graphical User Interface for embedded systems
using QVGA or smaller LCD panels. Using the SLCD is simply the quickest way to
generate a user interface without a lot of graphical programming. It has a small size to fit in
space-constrained applications.
1.2. Features
Drives either active (TFT) and passive (STN) displays
Touch controller (4 wire resistive) on board
Beeper for audible touch feedback and alarms
3" by 4.5" size, only 0.2" thick
Low power (40mA typical at 5V)
RS232 or TTL level interface up to 115200 baud
User downloadable bitmaps with RLE compression (4MB of flash memory)
Backlight enable and brightness control
Reasonable cost
Supports either landscape or portrait mode display (firmware option)
Can be modified for specific OEM requirements
RoHS Compliant as of Jan 1, 2007
SLCD+ Controller Manual V1.1 8/14/2009 Page 8

1.3. Dimensions - Rev G board
Figure 1: SLCD+ Rev A Board Physical Dimensions (inches)
SLCD+ Controller Manual V1.1 8/14/2009 Page 9

1.4. Electrical Characteristics
The SLCD+ board takes in two voltages. One is simply passed though to the backlight
inverter, and is typically either 5V or 12V. The SLCD+ itself requires 5V. For other
hardware options, contact Reach Technology Inc.
The SLCD+ is designed for panels with VCC of 3.3V and built-in DC-DC converters and
therefore do not need high positive or negative voltages. A list of compatible panels in
provided in Appendix A.
Typical current draw is as follows:
State mA
No panel attached, beeper quiet 40
No panel attached, beeper active 80
In general, the panel backlight power requirements dominate the power budget.
1.5. Environmental
The standard SLCD+ controller is rated for commercial temperature operation of 0 to 70ºC.
An industrial grade -40 to 85ºC version is available as a special order. Note that most LCD
panels have a limited operating temperature range of -20 to 70ºC.
1.6. Panel support
The SLCD+ is factory programmed with panel configuration-specific firmware that
includes panel type, orientation (landscape / portrait), backlight inverter control polarity,
and touch panel orientation. Panel types include passive color (CSTN), or active matrix
(TFT). Different commands and connection options may not apply depending on the
firmware programmed on a given board. For example, there is contrast adjustment for
passive panels but not for TFT panels. Please note that both landscape and portrait display
modes cannot be supported by the same firmware; that is, the panel orientation cannot be
changed “on-the-fly”. The firmware is in-system-upgradable to support different
requirements and version upgrades.
1.7. Upgrade options
Reach has an upgrade to the SLCD+ that can provide more performance and supports
larger panels. To provide for such an upgrade, the four mounting holes that are symmetric
with respect to the board outline are recommended for use.
SLCD+ Controller Manual V1.1 8/14/2009 Page 10

2. Configuration Guide
2.1. Power
Note: The standard configuration is for 5V power input and 3.3V panel power. For other
configurations, please contact Reach.
2.2. Serial
The SLCD+ has four serial ports. Any can be used to send commands to the board. The
ports and their characteristics are as follows:
Port Description
COM0 Typically RS-232; remove a resistor for 3.3V CMOS logic level
COM1 3.3V CMOS logic only. Control signal (RTS) for RS485 driver enable
COM2 RS232 only
COM4 3.3V or 5V logic level I/O (on-board voltage translator)
COM0 is primarily used for RS232 communication, while COM1 supports 3.3V CMOS
level signaling with RTS handshaking for an external transceiver such as RS485.
By default, serial communications is 115200 baud, 8 data bits, no parity, with 1 stop bit,
with receive flow control via XON / XOFF. This can be changed by using a “power-on
macro” which is described in the companion manual SLCDx Software Reference.
2.3. TFT Panel Orientation
The SLCD+ can support QVGA TFT panels with standard 33 pin flat flex pinouts. Some
panels also have signals for display orientation, called Right/Left and Up/Down. These
signals are controlled via the firmware using the “*orient” command. Refer to the SLCDx
Software Reference.
2.4. Grounding
In order for the touch screen to work properly with a panel that has a CCFL backlight, the
panel metal frame must be grounded to the SLCD+ ground. All SLCD+ mounting holes are
connected to SLCD+ ground.
SLCD+ Controller Manual V1.1 8/14/2009 Page 11

3. Connectors and Jumpers
Figure 2: Connectors and Jumpers
3.1. J6 - Power and COM0 (RS232 communications mode)
J6 8 Pin Molex 53261-0871 for Power and Communications
Pin RS232 Mode – R24 installed on board
1 do not connect
2 do not connect
3 RS232 input *
4 RS232 output
5 Backlight voltage (typ. 5V or 12V)
6 3.3V out (reference only)
7 5V Input
8 GND (power and communications)
* RS232 input valid only if R24 installed as zero ohms.
This is the factory default.
SLCD+ Controller Manual V1.1 8/14/2009 Page 12

Typical connection from a PC is as follows:
3.2. J4 – COM2 RS232 port
J4 3 Pin Molex 53261-0371 or equivalent
Pin RS232 Mode – R24 installed on board
1 RS232 output
2 RS232 input
3 GND
3.3. J5 – Power and COM3 3.3V / 5V port
J6 8 Pin Molex 53261-0871 for Power and Communications
Pin RS232 Mode – R24 installed on board
1 TxD (out)
2 RxD (in)
3 (Not connected)
4 R6 installed (default): 3.3V
R6 removed: external I/O voltage 3.3V or 5V
5 Backlight voltage (typ. 5V or 12V)
6 3.3V out (reference only)*
7 5V Input
8 GND (power and communications)
Can be set to GND via jumper if needed – check with Reach
GND
P1
AMP 747844-4
5
9
4
8
3
7
2
6
1
PC serial compatible
pinout DB9 Female
J6
Molex 53261-0890
1
2
3
4
5
6
7
8
PC DATA OUT
PC DATA IN
5V in
GND
Backlight Voltage
SLCD WITH
R24 INSTALLED
SLCD+ Controller Manual V1.1 8/14/2009 Page 13

3.4. J12 - 4 Wire Touch
J12 4 Pin Molex 52271-0469 or equivalent 1mm pitch bottom
contact Zero-Insertion-Force Connector
Pin Signal
1 X1 (left / right / up / down)*
2 Y1 (up / down / left / right )*
3 X2 (right / left / down / up )*
4 Y2 (down / up / right / left )*
* The sense of X and Y and up / down / right / left is determined by
the touch calibration procedure – see “tc” command in the SLCDx
Software Reference Manual.
3.5. J11 - 4 Wire Touch
J11 4 Pin Molex 39-51-3043 or equivalent 1.25mm pitch top
contact Zero-Insertion-Force Connector
Pin Signal
1 X1 (left / right / up / down)*
2 Y1 (up / down / left / right )*
3 X2 (right / left / down / up )*
4 Y2 (down / up / right / left )*
* The sense of X and Y and up / down / right / left is determined by
the touch calibration procedure – see “tc” command in the SLCDx
Software Reference Manual.
3.6. J2A - 4 Wire Touch*
J12 4 Pin Molex 22-05-3041 or equivalent 0.1" pitch 0.025" square post
right angle friction latch Connector
Pin Signal
1 X1 (left / right / up / down)*
2 Y1 (up / down / left / right )*
3 X2 (right / left / down / up )*
4 Y2 (down / up / right / left )*
* Normally not provided.
SLCD+ Controller Manual V1.1 8/14/2009 Page 14

3.7. J7 - 20 pin 0.5mm Flat Flex LCD Connector
J7 20 Pin Omron XF2M-2015-1A or equivalent 0.5mm pitch Zero-Insertion-Force Connector
Pin Signal Pin Signal
1 LCD Frame Pulse 11 LCD Data 4
2 LCD Line Pulse 12 LCD Data 3
3 LCD Clock 13 LCD Data 2
4 LCD Display On (DISPOFF-) 14 LCD Data 1
5 LCD VCC 15 LCD Data 0
6 GND 16 Contrast Control
7 Contrast Voltage 17 LCD VCC
8 LCD Data 7 18 LCD VCC
9 LCD Data 6 19 GND
10 LCD Data 5 20 GND
3.8. J8 - 16 pin 1mm Flat Flex LCD Connector
J8 16 Pin 52207-1685 or equivalent 1mm top contact Zero-Insertion-Force Connector
Pin Signal Pin Signal
1 LCD Frame Pulse 9 LCD Data 1
2 LCD Line Pulse 10 LCD Data 2
3 LCD Clock 11 LCD Data 3
4 LCD Display On (DISPOFF-) 12 LCD Data 4
5 LCD VCC 13 LCD Data 5
6 GND 14 LCD Data 6
7 Contrast Voltage 15 LCD Data 7
8 LCD Data 0 16 GND
3.9. J9 - 33 pin 0.5mm Flat Flex LCD Connector
J9 33 Pin Omron XF2H-3315-1LW or equivalent 0.5mm pitch Zero-Insertion-Force Connector
Pin Signal Pin Signal
1 GND 18 Green 5
2 LCD Clock 19 GND
3 LCD Line Pulse 20 Blue 0 (= Blue 4)
4 LCD Frame Pulse 21 Blue 1 (= Blue 5)
5 GND 22 Blue 2
6 Red 0 (= Red 4) 23 Blue 3
7 Red 1 (= Red 5) 24 Blue 4
8 Red 2 25 Blue 5
9 Red 3 26 GND
10 Red 4 27 LCD DE
11 Red 5 28 LCD VCC
12 GND 29 LCD VCC
13 Green 0 (= Green 4) 30 R/L (controlled by *orient cmd)
14 Green 1 (= Green 5) 31 U/D (controlled by *orient cmd)
15 Green 2 32 GND
16 Green 3 33 GND
17 Green 4
.
SLCD+ Controller Manual V1.1 8/14/2009 Page 15

SLCD+ Controller Manual V1.1 8/14/2009 Page 16
3.10. J10 - Backlight / Inverter Control
J10 4 Pin Molex 53261-0471
Pin Signal
1 Backlight power (connected to J6 pin 5)
2 Ground
3 Backlight on/off control; can also be used as PWM for dimming
4 Backlight brightness control
This connector is used to power and control the panel backlight. The sense of the on/off
control (active high or low) is set in the firmware. The sense and range of the brightness
voltage output is also set by the board firmware.
3.11. JP1 – COM1 / Programming Header
This connector is used for communicating using the COM1 serial port. It has a driver
enable for use with RS485 transceivers. It also has a hardware reset signal for the SLCD+
processor.
JP1 10 Pin Molex 53261-1071
Pin Signal
1 VCC (typ. 3.3V) – can be used to power external transceiver
2 DE (active high) – use if needed to enable external 422 / 485 driver
3 Do not use
4 RxD1 – Com1 input
5 Do not use
6 Do not use
7 GND
8 RESET- input; drive low to hardware reset the SLCD+ processor
9 Do not use
10 TxD1 – Com1 output
TxD1, RxD1, DE, RESET- electrical specifications:
Input voltage -0.3 / VCC+.03 Absolute Min / Max
Input voltage 0.8xVCC High min
Input voltage 0.2xVCC Low max
Output current High 1mA Min, Vout = 0.9xVCC
Output current Low -1mA Min, Vout = 0.1xVCC

4. System Overview
4.1. General SLCD+ Controller
The SCLD acts as a "smart terminal" and is generally connected to a host processor that
implements the desired Graphical User Interface (GUI) by issuing commands to the
SLCD+ and processing button press responses from the SLCD+. In this manual, the term
"host" is used to describe the device connected to the SLCD+.
Please refer to the SLCDx Software Reference Manual for more detail.
4.2. Overview - SLCD+ Evaluation Kits
The SCLD+ is available in an evaluation kit form, and also as a complete enclosed unit. In
the kit or enclosure, it comes pre-loaded with bitmaps and macros that implement a demo
if the unit is powered on with the communications port looped back transmit to receive.
This loopback is via external plug in the case of the enclosed unit, or via a jumper on the
"PowerCom" board in the case of the unenclosed kit.
The SLCD+ evaluation kit comes with hardware and firmware options loaded for the
specific panel supported by the kit. It also includes a two-port DB9 interface board that
makes it easier to connect to external host systems. One port can be used to download
bitmaps from a PC while the other connects to the "host" computer.
4.2.1. Getting Started
The SLCD+ kit as shipped contains a demo that allows you to verify its functionality. Plug
the supplied power supply into the barrel connector on the triangular shaped PowerCom 4
board. The display should light up and lead you through various touch-activated screens.
4.2.2. Connecting the kit to a PC
The kit should be connected to a PC so that the serial command interface can be
experimented with. This is a preliminary step before the unit is connected to the embedded
system that will control the display in the embedded system..PLEASE NOTE: In order
to communicate over the serial port, the Demo jumper JP1 on the triangular
PowerCom4 board must be removed. This jumper loops back transmit to receive on the
serial port and this is what tells the SLCD+ to run the demo.
SLCD+ Controller Manual V1.1 8/14/2009 Page 17

As shipped, the serial port is set to 115,200 baud, 8 bit, 1 start, 1 stop, no parity. There are
two DB9 connectors on the "PowerCom 4" board. Connect the PC using a straight through
cable to the DB9 marked "MAIN" (P1). A USB-to-serial adapter cable can also be used
and plugged directly into this connector. Note: the Belkin USB-serial adapter has
software compatibility issues and is not recommended; Reach recommends either
Prolific or FTDI chip based adapters.
Once connected, use RealTerm (preferred), HyperTerminal, or similar terminal emulator to
send and receive commands from the kit. HyperTerminal has limitations that can cause
problems; specifically, some versions cannot send the "escape" character. We recommend
RealTerm (shareware – Google “realterm” to download).
4.2.3. Developing the application GUI with an embedded controller as host
To develop the actual application, determine whether the host will interface via 3.3V or 5V
CMOS levels or RS232 levels. Then connect the host accordingly to either J6 (232) or J5
(CMOS levels). Then connect the PC to either J6 or J4 whichever is not used. This way
either the host or the PC can drive the SLCD+. Typically the PC is used to experiment and
determine what command is needed for a graphical interface, and to download new
bitmaps and macros without having to disconnect the embedded system.
How this dual port connection works is this: the SLCD+ has a non-volatile memory which
remembers which port is the “main” control port. This is selected via the *com0main or
*com1main command. The other port is then the aux port. When the aux port receives
three <return> characters in a row, it switches to become the main port. This way, the PC
can take control of the SLCD+ communications channel and send commands or download
new bitmaps. Use the reset button to simulate a power-on event which restores the main
port as the default control port, or use the *prevCons command.
SLCD+ Controller Manual V1.1 8/14/2009 Page 18

4.3. PowerCom4 Board
PowerCom4 Board
SLCD+ Controller Manual V1.1 8/14/2009 Page 19

4.4. PowerCom4 Schematic
SLCD+ Controller Manual V1.1 8/14/2009 Page 20
Table of contents
Popular Controllers manuals by other brands

TimeTec Security
TimeTec Security BLE-16 installation guide

Enterasys
Enterasys C4110 quick reference

Kutai electronics
Kutai electronics ADVR-250 Operation manual

Lippert Components
Lippert Components OneControl HVAC Control 2.0 OEM INSTALLATION MANUAL

Leetro
Leetro MPC6575 Manufacturer's manual

Masibus
Masibus 85XX+ Quick user guide

ENDA
ENDA ELC-286RT user manual

Triple Plus
Triple Plus CLM-IRAMAP-1-02 quick start guide

Pioneer
Pioneer DDJ-SP1 operating instructions

Kutai electronics
Kutai electronics EA05A Operation manual

National Instruments
National Instruments PXI NI PXI-8105 user manual

KINSHOFER
KINSHOFER PROLEC PME300 user manual