manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Rean
  6. •
  7. Cables And Connectors
  8. •
  9. Rean RCAC3M-X-000 User manual

Rean RCAC3M-X-000 User manual

|
R
B
D
A
R
Page 1
A
.
Insert cable into the bushing and housing.
Note:“Apply cable pulling
lubricant to cable jacket.”
BSeperate the housing from the bushing
(cable remain in bushing)
CPlace chuck over the cable.
C
DPrepare cable as shown.
VDE (EN 60320-1/EN60320-2-2) UL (UL 60320-1/CSA C22.2 NO.60320-1)
20mm [0.787"]
P 23 mmE [0.9"]
8 mm
[0.32"]
20mm [0.787"]
P 23 mmE [0.9"]
8 mm
[0.32"]
RCAC3M-X-000
ASSEMBLY INSTRUCTION
40-50 mm
A.
Power Cable Connector
ASSEMBLY INSTRUCTION
G
VDE ULWiring
blackL brown
whiteN blue
green/yellow green
E
F
Draft. Nr.: NCN 026 Update: 2022-04-26
I
www.rean-connectors.com
Neutrik AG LI T: +423 / 237 24 24 F: +423 / 232 53 93
( )
Neutrik UK Ltd. UK T: +44 1983 / 811 441 F: +44 1983 / 811 439
Neutrik Vertriebs GmbH DE / NL / AT/DK T: +49 8131 / 280 890 F: +49 8131 / 280 830
Neutrik USA Inc. USA T: +1 704 / 972 3050 F: +1 704 / 438 9202
Data subject to change without prior notice. 2021 REAN . is registered trademark of Neutrik AG. ALL RIGHTS RESERVED.
® ®
© REAN
Neutrik France FR T: +33 1 / 4131 6750 F: +33 1 / 4131 0511
Neutrik Tokyo Ltd. JP T: +81 3 / 3663 4733 F: +81 3 / 3663 4796
Neutrik Hong Kong Ltd. HK T: +852 / 2687 6055 F: +852 / 2687 6052
Page 2
R
R
ASSEMBLY INSTRUCTION
|
Torque Value 0.7 Nm
Slide the cable into the contacts and clamp
with the screw with Torx size T8.
Torx size T8
E
3.
1.
2.
Important
Push and turn simultaneously.
Important:Align the chuck by positioning the nose
into keyway.
Slide chuck onto insert (1) and then both into
housing (2).
F
4.
Torque Value 2.0NM
5.
Slide the cable clamp (3) bushing up the cable and
tighten it.
Important: Black O-ring to hide to achieve IP
protection (6)
G
Turn bushing 360
Press with screw driver to unlock
Repat step + until bushing is unscrewed.
FOR DISASSEMBLY - OPEN TWIST LOCK!
1.
2.
3. 1. 2.
1.
2.
category,do not expose the
connection to bending forces
(e.g. do not attach loads to
the cable,no free-dangling
cable windings etc.).
CAUTION
To ensure protection
XLR Cable Connectors:
Find more details on
www.rean-connectors.com
FORCE
Power Cable Connector
Draft. Nr.: NCN 026 Update: 2022-04-26
I
www.rean-connectors.com
Neutrik USA Inc. USA T: +1 704 / 972 3050 F: +1 704 / 438 9202
( )
Neutrik UK Ltd. UK T: +44 1983 / 811 441 F: +44 1983 / 811 439
Neutrik Vertriebs GmbH DE / NL / AT/DK T: +49 8131 / 280 890 F: +49 8131 / 280 830
Neutrik AG LI T: +423 / 237 24 24 F: +423 / 232 53 93
Data subject to change without prior notice. 2021 REAN . is registered trademark of Neutrik AG. ALL RIGHTS RESERVED.
® ®
© REAN
Neutrik Hong Kong Ltd. HK T: +852 / 2687 6055 F: +852 / 2687 6052
Neutrik Tokyo Ltd. JP T: +81 3 / 3663 4733 F: +81 3 / 3663 4796
Neutrik France FR T: +33 1 / 4131 6750 F: +33 1 / 4131 0511
Page 3
R
R
ASSEMBLY INSTRUCTION
|
RRAC3M-X-000 RRAC3F-X-000
RCAC3M-X-000
(Plug connector)
B.
2
RCAC3F-X-000
It serves to supply power to an appliance and from an appliance to other equipment.
The power con system is certified as a connector with breaking capacity according to IEC60320,VDE
0625.It is intended for use as an appliance coupler and interconnect coupler.
Application:
To be installed by qualified person only.
CONNECTOR ASSIGNMENT
Power IN
(Connector)
APPLIANCE INLET APPLIANCE OUTLET
Power OUT
Approval based:
Rating:
Cable Type:
VDE
IEC 60320-1/EN 60320-1
250V ac/16A
HV05V-F3G 1.0mm ,Length max. 2m
HV05V-F3G 1.5mm-2.5mm
2
Strain Relief:
Cable O.D.:
White chuck
6.0 - 12.0 mm
UL
UL 60320-1/CSA C22.2 NO.60320-1
250V ac/20A
SJTOW,SJOOW 3X12 AWG
6.0 - 12.0 mm
White chuck
UL50E environmental rating
Enclosure Type when mated with attachment plug RRAC3M-X-000 with Sealing Cover RA-X-001 and
RRAC3F-X-000 with sealing cover RA-X-003.
H07RN-F3G 1.5mm2
Power Cable Connector
ASSEMBLY INSTRUCTION

Other Rean Cables And Connectors manuals

Rean RCAC3F-X-000 User manual

Rean

Rean RCAC3F-X-000 User manual

Rean NSB Series Installation guide

Rean

Rean NSB Series Installation guide

Rean RT*FC-B Installation guide

Rean

Rean RT*FC-B Installation guide

Popular Cables And Connectors manuals by other brands

Digitus DS-43304 manual

Digitus

Digitus DS-43304 manual

Raychem Gardian W51 installation instructions

Raychem

Raychem Gardian W51 installation instructions

Show MICRO 3 Service manual

Show

Show MICRO 3 Service manual

Nidec SI-Interbus 500 kBd user guide

Nidec

Nidec SI-Interbus 500 kBd user guide

Blonder tongue ASI-4 instruction manual

Blonder tongue

Blonder tongue ASI-4 instruction manual

Sennheiser ASA 214 quick guide

Sennheiser

Sennheiser ASA 214 quick guide

DeDietrich JA8 Assembly instructions

DeDietrich

DeDietrich JA8 Assembly instructions

Philips SWV2817W Specifications

Philips

Philips SWV2817W Specifications

Goobay 81292 user manual

Goobay

Goobay 81292 user manual

Stihl AP instruction manual

Stihl

Stihl AP instruction manual

Pentair Raychem CCON25-100 Installation and operating instructions

Pentair

Pentair Raychem CCON25-100 Installation and operating instructions

HP Xw4600 - Workstation - 2 GB RAM Installation guidelines

HP

HP Xw4600 - Workstation - 2 GB RAM Installation guidelines

Delphi Delphi Assembly manual

Delphi

Delphi Delphi Assembly manual

Digitus DS-45328 Quick installation guide

Digitus

Digitus DS-45328 Quick installation guide

VOLTCRAFT DO-55 operating instructions

VOLTCRAFT

VOLTCRAFT DO-55 operating instructions

SpeakerCraft PTJ-40 instructions

SpeakerCraft

SpeakerCraft PTJ-40 instructions

Nordost VALHALLA 2 instruction manual

Nordost

Nordost VALHALLA 2 instruction manual

Vention VWS-B05 user guide

Vention

Vention VWS-B05 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.