Red Arrow SHC-RC User manual

Smoke Alarm Controller
Product Codes: SHCRC
Box Contents -
1 x SHC- RC Smoke Alarm Controller
Dimensions: Ø: 60mm x D: 13.2mm
Power: Cr2450 replaceable battery
Product Life: 3 Years
Modulation: FSK
Operating Temp: 0 - 40°C
Operating Humidity: 15% - 95% (Non Condensing)
INSTALLATION INSTRUCTIONS
PAGE 1 (FRONT PAGE)
13.2mm
60mm
SILENCE
LOW BATTERY
INDICATOR
ALARM
INDICATOR
LOCATE
TEST
3
YRS
GUARANTEE
Thank you for purchasing
the SHC-RC smoke alarm
controller. Please take a few
minutes to thoroughly read
the user guide and familiarize
yourself and your family with
its operation and save for
future reference.
Specication
DESCRIPTION:
This smoke alarm controller is a device that wireless interconnection with all the smoke
alarms in family. It helps to test smoke alarm, silence smoke alarm and locate to nd out
source smoke alarm easily in daily life.
Safety Warning
• The installation should be carried out
by a competent person.
• Follow the provided installation
instructions, using the xings supplied
or recommended.
• Keep out of reach of children.
Ver: 1.0
Alarm Controller Functionality
Test Press the ”TEST” button with red LED ashes once, all
interlinked smoke alarms will beep for 7 seconds.
Locate Press the ”LOCATE”button with red LED ashes once,
silence all smoke alarms except the one sensing re.
Silence Press the ”SILENCE”button with red LED ashes once, all
smoke alarms will be silenced for 8 minutes.
Fire Indicator When the smoke alarm alarming, the red LED will ash
twice a second.
Low Battery Indicator When the smoke alarm controller is in low battery
mode, the yellow LED will ash once every 8 seconds.
Silence Button
Test Button
Locate Button
Yellow LED Light Red LED Light
The Smoke Alarm Controller is suggested to be installed on the wall 1.4m+/-0.2m
from oor level, which will provide the best wireless transmission distance.
Installation
Press silence button and hold it for about 5 seconds until the red and yellow light
at the same time, which means the device is activated. Then release the button.
CAUTION: This device is only need to be activated the rst time you use it.
Activation

INS/ELEC/0008/SHC-RC/V1
T: 0800 195 0006
sales@redarrowelectrical.co.uk
Red Arrow Electrical Ltd
Cortonwood Drive, Brampton,
Barnsley, S73 0UF redarrowelectrical.co.uk
Method A:
1. Press the “TEST“ button of the wireless smoke alarm three times
within 2 seconds, until the Red LED ashes quickly, now the smoke
alarm is the MASTER unit. The controller and the other Smoke Alarms
are the SLAVE units.
2. Press the ”SILENCE” button of the controller three times within 2
seconds, the controller will enter to learning mode with Red led light
ash once 1 seconds, after learning the signal and complete the
pairing from MASTER unit successfully, the Red Led light will be o.
Method B:
1. Press the“SILENCE“ button of the controller three times within 2
seconds, the red LED will ash quickly for 30 seconds, it means the
smoke alarm controller is in sending pairing mode. Then the controller
is the MASTER unit. And the other Smoke Alarms are the SLAVE units.
2. Press the “TEST” button on the SLAVE three times within 2 seconds.
the SLAVE units lean this singal and completes the pairing after a
“beep“ sound and a light ashed once.
Wireless Interconnection Function
Press ”TEST” button and ”LOCATE” button at the same time, and hold them for
10 seconds until the red LED ashes once, then release the buttons.
Clear Wireless Connection Function
This product is guaranteed for a period of 3 years from the date of purchase.
The guarantee is invalid in the case of improper use, tampering, removal of the
Q.C. date label, or installation in an improper working environment. Should
this product fail during the guarantee period it will be replaced free of charge,
subject to correct installation and return of the faulty unit. We do not accept
responsibility for any installation costs associated with the replacement of this
product. Your statutory rights are not aected. We reserve the right to alter
specications without prior notice.
Guarantee
Trouble Shooting
PROBLEM GENERAL
SITUATION
METHOD OF
JUDGEMENT
METHOD OF
DISPOSAL
No reat when
press test button
Press test button
whithout red LED
ashing
Check the battery
installation
Install the battery
correctly
Press the test button,
the red led ashes but
no alarming
Check the
inerconnection between
alarm and alarm
controler
Interconnect again
Check alarms working
status Maintain the alarm
Check whether the alarm
is within the control
range of alarm controller,
or whether there are
metal parts, wires and
other interference
around
Change the
position of alarm
Yellow LED
ashes
Yellow LED ashes
once every 8 secounds
Please change the
battery
1. Press the “Test” button once with the red LED
ashes once on the smoke alarm controller,
indicating the smoke alarm controller is in testing
mode. the smoke alarm controller will send signal
for 7 secounds to all interlinking smoke alarms.
2. All interlinked smoke alarms will recived the
signals, then the smoke alarms will beep about 7
secounds within 7 secounds.
3. Press the“SILENCE” button once with red LED
ashes once to turn o the controller from
“TESTING”mode.
4. If not, Repeat Step 1.
Testing Mode
1. Press the“SILENCE” button once with the red
LED ashes once onthe smoke alarm controller.
2. After 3 secounds, all interlinked smoke alarms
will stop alarming for 8 minuetes
3. If not, Repeat Step 1.
Silence Mode
1. When all interlinked smoke alarms alarming,
pressing the ”LOCATE” once with red LED
ashes once on the smoke alarm controller.
2. After 5 seconds, the controller will silence all
smoke alarms except the one sensing re.
3. 3. If not, repeat Step 1.
Locate Mode
When the smoke alarm alarming, the red LED will
ash once a second.
Fire Indicator Mode
When the smoke alarm controller’s battery below
the threshold, the yellow LED will ash every 8
seconds.
Low Battery Mode
1. Remove the back of the controller by removing x2 screws.
2. Remove the battery.
3. Replace with a CR2450 battery.
4. Return the back cover and tighten the x2 screws securely.
5. Safely dispose of the old battery.
Battery Replacement - 1 x CR2450
.
This product contains a replaceable (coin/button) battery which poses a risk to
children and can cause injury.
If the smoke alarm controller is damaged, or the battery compartment (back
cover) dose not close securely, dispose of the defective smoke alarm controller and
replace with a new one.
If it is suspected a button/coin battery has been swallowed or otherwise placed
inside any part of the body, a person should contact your local poison center
immediately for 24/7 fast, expert advice.
Do not ingest battery, chemical Burn Hazard. If the coin/button cell battery is
swallowed , it can cause severe internal burns in just 2 hours and can lead to death.
Keep New and Used Batteries Away From Children.
WARNING
KEEP OUT OF REACH OF CHILDREN
Swallowing can lead to chemical burns,
perforation of soft tissue, and death.
Severe burns can occur within 2 hours
of ingestion. Seek medical attention
immedialely.