www.altronics.com.au
User manual revision number: 1.0 11/11/2014
Operating Manual
A 4581 Alert/Evac/Chime/Cancel Remote Plate
Redback® Proudly Made In Australia
Overview
The A 4581 wall plate allows remote triggering of the Alert, Evacuation and Chime tones and the cancel function of the
A 4575A Alert/Evacuation Controller. The switches are momentary operation and must be pressed for up to 3 seconds to
activate. The Alert and Evac switches have protective “ip up” covers to prevent accidental operation.
Connections
There are two RJ45 ports on the rear of the A 4581 wall plate, either of which can be used to connect to the A 4575A via
standard Cat5e cabling as shown in Fig 2. If the A 4581 has a connection problem with the A 4575A main unit the LED on
the wall plate will ash.
Remote triggering is only available when the A 4575A is in “Auto” mode which is selected by the key switch on the front
of the A 4575A. If the Alert, Evac and Chime switches on the A 4581 plate are pressed when the A 4575A main unit is in
“Manual” or “Isolate” mode, nothing will happen. The LED on the wall plate will illuminate when the A 4575A main unit
is in “Manual” or “Isolate” mode to alert the user that the wall plate is inactive.
If the Alert and Evac switches are pressed on the A 4575A while the unit is in “Manual” mode the corresponding Alert,
Evac and Chime switches on the A 4581 wall plate will illuminate.
Cascading the A 4581 plates
If more than one remote wall plate is required then the A 4581
wall plates can be cascaded together with only one connection
back to the A 4575A required as shown in Fig 2.
A Maximum of 16 plates is recommended, (If more than 16 wall
plates are required contact Altronics for conguration details).
There are two RJ45 ports on the rear of the A 4575A, either of
which can be used for connection to the wall plates.
The A 4575A also supports connection of the A 4578 wall plate
which is the same as the A 4581 but without the “Chime”
button. Both the A 4578 and A 4581 plates can be
connected to the A 4575A at the same time and in any
combination. Figure 3 illustrates one example.
Every wall plate must have a unique ID which is set by the DIP
switches which are accessed on the rear of the plate. A
maximum of 63 ID’s are available. Remove power before
changing DIP switch settings. The new settings will take effect
when power is returned.
Fig 1 Illustrates the DIP switch ID settings.
DIP Switches 7-8 are not used.
DIP Switch Settings
ID 12 3
ON OFF OFF
1
45 6
OFFOFF OFF
OFF ON OFF
2OFFOFF OFF
ON ON OFF
3OFFOFF OFF
OFF OFF ON
4OFFOFF OFF
ON OFF ON
5OFFOFF OFF
OFF ON ON
6OFFOFF OFF
ON ON ON
7OFFOFF OFF
OFF OFF OFF
8OFFON OFF
ON OFF OFF
9OFFON OFF
OFF ON OFF
10 OFFON OFF
ON ON OFF
11 OFFON OFF
OFF OFF ON
12 OFFON OFF
ON OFF ON
13 OFFON OFF
OFF ON ON
14 OFFON OFF
ON ON ON
15 OFFON OFF
OFF OFF OFF
16 ONOFF OFF
ON OFF OFF
17 ONOFF OFF
OFF ON OFF
18 ONOFF OFF
ON ON OFF
19 ONOFF OFF
OFF OFF ON
20 ONOFF OFF
ON OFF ON
21 ONOFF OFF
OFF ON ON
22 ONOFF OFF
ON ON ON
23 ONOFF OFF
OFF OFF OFF
24 ONON OFF
ON OFF OFF
25 ONON OFF
DIP Switch Settings
ID 12 3
33
45 6
ON
34 ON
35 ON
36 ON
37 ON
38 ON
39 ON
40 ON
41 ON
42 ON
43 ON
44 ON
45 ON
46 ON
47 ON
48 ON
49 ON
50 ON
51 ON
52 ON
53 ON
54 ON
55 ON
56 ON
57 ON
OFF ON OFF
26 ONON OFF
ON ON OFF
27 ONON OFF
OFF OFF ON
28 ONON OFF
ON OFF ON
29 ONON OFF
OFF ON ON
30 ONON OFF
ON ON ON
31 ONON OFF
OFF OFF OFF
32 OFFOFF ON
58 ON
59 ON
60 ON
61 ON
62 ON
63 ON
ON OFF OFF OFFOFF
OFF ON OFF OFFOFF
ON ON OFF OFFOFF
OFF OFF ON OFFOFF
ON OFF ON OFFOFF
OFF ON ON OFFOFF
ON ON ON OFFOFF
OFF OFF OFF OFFON
ON OFF OFF OFFON
OFF ON OFF OFFON
ON ON OFF OFFON
OFF OFF ON OFFON
ON OFF ON OFFON
OFF ON ON OFFON
ON ON ON OFFON
OFF OFF OFF ONOFF
ON OFF OFF ONOFF
OFF ON OFF ONOFF
ON ON OFF ONOFF
OFF OFF ON ONOFF
ON OFF ON ONOFF
OFF ON ON ONOFF
ON ON ON ONOFF
OFF OFF OFF ONON
ON OFF OFF ONON
OFF ON OFF ONON
ON ON OFF ONON
OFF OFF ON ONON
ON OFF ON ONON
OFF ON ON ONON
ON ON ON ONON
Fig 1
www.altronics.com.auRedback® Proudly Made In Australia2
N/O
DC FUSE
(1A M205)
24V DC
IN
N/C
+_
240V AC Fuse M205 500mA
Volume
Chime Tones BGM
Cancel
Contacts
Evac
Contacts
Alert
Contacts
Bell
Contacts
DIP Switches
Interface 1
1 2 3 4 5 6 7 8
Switched
24V Out
N/O
N/C
Bell
24V Out
N/O
N/C
Evac
24V Out
N/O
N/C
Alert
24V Out
Interface 2
1 2 3 4 5 6 7 8
A 4575A ALERT/EVAC CONTROLLER
CAT5e cable
(Max 300 Metres)
A 4578 Remote
Wall Plate
Evac CancelAlert
Master unit in manual mode (Plate Inactive)
Evac CancelAlert
Master unit in manual mode (Plate Inactive)
Up to a maximum 16 wall plates can be
cascaded together. (*)
Both RJ45 ports from the A 4575A can be utilised.
Any combination of A 4578 or A 4581 plates can
be used together.
* (If more than 16 wall plates are required contact
Altronics for conguration details).
CAT5e cable
(Max 300 Metres)
Evac CancelAlert
Master unit in manual mode (Plate Inactive)
Evac CancelAlert
Master unit in manual mode (Plate Inactive)
Evac CancelAlert
Master unit in manual mode (Plate Inactive)
Evac CancelAlert
Master unit in manual mode (Plate Inactive)
A 4578 Remote
Wall Plate
Evac
Alert
Chime Cancel
Master unit
in manual
mode.
(Plate
Inactive)
Evac
Alert
Chime Cancel
Master unit
in manual
mode.
(Plate
Inactive)
A 4578 Remote
Wall Plate
A 4581 Remote
Wall Plate
A 4581 Remote
Wall Plate
A 4578 Remote
Wall Plate
A 4578 Remote
Wall Plate
A 4578 Remote
Wall Plate
If any of the A 4578 or A 4581 plates has a connection problem
with the A 4575A main unit the LED on the wall plate will ash.
Fig 2
Fig 3
N/O
DC FUSE
(1A M205)
24V DC
IN
N/C
+_
240V AC Fuse M205 500mA
Volume
Chime Tones BGM
Cancel
Contacts
Evac
Contacts
Alert
Contacts
Bell
Contacts
DIP Switches
Interface 1
1 2 3 4 5 6 7 8
Switched
24V Out
N/O
N/C
Bell
24V Out
N/O
N/C
Evac
24V Out
N/O
N/C
Alert
24V Out
Interface 2
1 2 3 4 5 6 7 8
A 4575A ALERT/EVAC CONTROLLER
CAT5e cable
(Max 300 Metres)
A 4581 Remote
Wall Plate
Up to 16 A 4581 wall plates can be cascaded
together from a single RJ45 port of the A 4575A .
* (If more than 16 wall plates are required contact
Altronics for conguration details).
CAT5e cable
(Max 300 Metres)
CAT5e cable
(Max 300 Metres)
CAT5e cable
(Max 300 Metres)
To next wall plate
Evac
Alert
Chime Cancel
Master unit
in manual
mode.
(Plate
Inactive)
Evac
Alert
Chime Cancel
Master unit
in manual
mode.
(Plate
Inactive)
Evac
Alert
Chime Cancel
Master unit
in manual
mode.
(Plate
Inactive)
Evac
Alert
Chime Cancel
Master unit
in manual
mode.
(Plate
Inactive)
Either of the RJ45 ports
of the A 4575A can be used.
If any of the A 4581 plates has a connection problem
with the A 4575A main unit the LED on the wall plate will ash.

Popular Remote Control manuals by other brands

Calimet CM9-864 instruction manual

Calimet

Calimet CM9-864 instruction manual

Sony RM-AV2000 Operating Instructions  (primary... operating instructions

Sony

Sony RM-AV2000 Operating Instructions (primary... operating instructions

ADC HiGain HRU-402 Quick installation

ADC

ADC HiGain HRU-402 Quick installation

Ramsey Electronics ICI16 Assembly and instruction manual

Ramsey Electronics

Ramsey Electronics ICI16 Assembly and instruction manual

Daikin BRC1D61 operating manual

Daikin

Daikin BRC1D61 operating manual

sunair RCU-9310B Operation and maintenance manual

sunair

sunair RCU-9310B Operation and maintenance manual

THOMSON ROC 6411 operating instructions

THOMSON

THOMSON ROC 6411 operating instructions

RadioLink RC4GS V2 instruction manual

RadioLink

RadioLink RC4GS V2 instruction manual

Hy-Ko O-GM909F Programming instructions

Hy-Ko

Hy-Ko O-GM909F Programming instructions

Denon RC-F400S operating instructions

Denon

Denon RC-F400S operating instructions

Cavius SMART manual

Cavius

Cavius SMART manual

Genius Gate Systems DMG1 66 Telecommander Setup instructions

Genius Gate Systems

Genius Gate Systems DMG1 66 Telecommander Setup instructions

Hunter ROAM XL Owners manual and programming instructions

Hunter

Hunter ROAM XL Owners manual and programming instructions

FUTABA FP-3FN instruction manual

FUTABA

FUTABA FP-3FN instruction manual

FRIEDLAND HIS5A Quick installation guide

FRIEDLAND

FRIEDLAND HIS5A Quick installation guide

Universal Electronics URC2068BC2 user guide

Universal Electronics

Universal Electronics URC2068BC2 user guide

BenQ TRY01 user manual

BenQ

BenQ TRY01 user manual

Samsung VG-TM2360E user manual

Samsung

Samsung VG-TM2360E user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.