Redbusbar SS10LNAN User manual

SmokeSight SS10LNAN V0.5
Page 1
SmokeSight Residential Smoke Alarm
By Redbusbar
Part Number: SS10LNAN
Description: 10 Year Lithium Battery Power Photoelectric Smoke Alarm with Option Card
PLEASE LEAVE THESE INSTRUCTIONS WITH THE OCCUPANT, TO BE RETAINED FOR THE LIFE OF THE ALARM.
Read all Instructions before Installation and Operation
Regular testing of this smoke alarm is necessary to ensure the unit is functional and that the battery is in good
condition. It is recommended that the smoke alarm be replaced after 10 years of normal service. The only user-
serviceable parts are the Option Card batteries. Refer to ‘Replacing the Backup Batteries’.
EQUIPMENT INSTALLATION HAZARD
• This product must only be used for the purpose described in these instructions and must be installed in accordance
with the local regulations.
• Ensure that the product has been correctly installed and tested for safe operation.
• Smoke Test each interlinked alarm. Check to ensure every interlinked alarm, alarms correctly. If any unit fails to
alarm, refer to ‘Troubleshooting’
Failure to follow these instructions may result in equipment damage or injury.
Smoke Alarm –Top View
Smoke Alarm –Bottom View
1. Option Card
(White) LED
2. Alarm (Red)
LED
3. Smoke Alarm
Power Switch
4. Option Card
Battery Holder
5. Option Card
Configuration
Switches
Mounting Base –Top View
Mounting Base –Bottom View
6. Locking Tab
7. Tamper Clip
1
2
7
6
7
7
7
6
4
3
5

SmokeSight SS10LNAN V0.5
Page 2
Specifications
Smoke Alarm
Application
Residential Smoke Alarm for domestic
dwellings
Installation
Ceiling or wall mounted
Power Supply
10 Year Lithium Battery
Sensing Type
Photoelectric. The smoke alarm contains
NO radioactive material
Environment
Altitude: 0m to 2,000m
Temperature: 0°C to 40°C
Humidity: 5% to 95%
Visual Indication
Alarm: Red LED
Audible
Indication
Alarm: 85dBA at 3m, ISO 8201
Battery Low: Chirp
Compliance
AS 3786:2014, AS/NZS 60065,
AS/NZS 60950.1, IEC 62599.2
Option Card
Application
Radio Interlink, Auto
Test, Escape Lighting,
Clap Silence
Power Supply
2 x AA Batteries
Interlink
Radio: 24 alarms over
150 metres free air
maximum
Visual Indication
Status, Alert, Escape:
White LED
Audible Indication
Alert: 50dBA at 3m
Battery Low: Chirp
Locations
This smoke alarm can be used in all residential homes and apartments and positioned in accordance with building
regulations and state legislation. Refer to figure below when deciding the number of and location of smoke alarms.
Avoid dead air space positions. Install smoke alarms along exit paths from bedrooms. Locate alarms in stairways as
stairways act as chimneys for smoke and heat. Locate a smoke alarm in any area where a smoker sleeps or where
electrical appliances are used in bedrooms. Smoke, heat and other combustion materials rise to the ceiling and
spread horizontally. In a residential dwelling, mount the smoke alarm in the centre of the ceiling. In mobile homes,
wall mount the smoke alarm on an inside partition to avoid the thermal barrier that may form under the ceiling.

SmokeSight SS10LNAN V0.5
Page 3
Locations to Avoid
Within 1 metre of air conditioner ducts, ceiling fans
and other high air flow areas. Smoke may be blown
away or diffused in these areas.
In areas where the temperature may fall below 0°C
or rise above 45°C. Failure to alarm, improper alarms
or nuisance alarms may result.
In damp or very humid areas such as bathrooms or
laundries, where the normal humidity may rise
above 95% or fall below 5% relative humidity. False
alarms and unstable operation may result.
In areas where particles of combustion are normally
present, such as garages or kitchens, as this can
cause false alarms.
In dusty or dirty areas, as an accumulation of dust
and dirt in the sensing chamber may block the
openings and prevent an alarm, or may cause false
alarms.
Where bugs or insects are present as they may block
the openings and prevent an alarm, or may cause
false alarms.
Within 1 metre of electrical noise sources, e.g.
fluorescent lights, LED lights and fan motors.
Electrical noise may cause nuisance alarms.
Installation
1. If tamper prevention is required (prevents alarm removal without the use of a tool), remove the Tamper Clip
from the mounting base by twisting it back and forth until it breaks loose.
2. Screw the mounting base onto the ceiling or wall using appropriate fasteners. Screw diameter 8gauge/4mm.
3. If the Radio Interlink feature is required, refer to Option Card - Radio Interlinked Smoke Alarms –Initial Setup.
4. If the Auto Test feature is required, refer to Option Card - Auto Test –Initial Setup.
5. If neither the Radio Interlinked nor Auto Test feature was setup then apply
option card power by installing 2xAA batteries into the into the top battery
bay of the smoke alarm
6. Engage and slide the smoke alarm along the mounting base until it is fully
home and it ‘clicks’. The smoke alarm power switch will be turned on
automatically when the smoke alarm is fully home and it ‘clicks’.
Slide
Ready to slide
Engages with a ‘click’
7. Check that the Red and White LEDs function. The Red LED will flash every 5mins and 45secs and White LED will
flash every 5mins to indicate correct operation.
8. Press the Test+Hush button to check that the alarm sounds.
9. If tamper prevention is required, slide the Tamper Clip between the ceiling and the mounting base, locking tab.
The Tamper Clip can be removed by gripping it with pliers and pulling the clip away from the smoke alarm.
Installation is not complete until the red and white LEDs are functioning correctly and the alarm has been checked
for correct operation.

SmokeSight SS10LNAN V0.5
Page 4
Loose Tamper Clip
Tamper Clip Installation
Tamper Clip Installed
Option Card
This section relates to option card operation only. For smoke alarm operation, refer below to the smoke alarm
section.
Operation
This smoke alarm incorporates an option card that supports the following features:
Auto Test –Automatic alarm, scheduled self-testing
Clap Silence - Hush a false smoke alarm with a hand clap
Escape Lighting –Escape path visibility during an alarm
Radio Interlink –Allows one smoke alarm to activate all smoke alarms wirelessly
During normal operations the white LED flashes once every 5mins to indicate that the option card and battery
backup is functional. The option card functions in two modes. In operation mode the option card displays option
card alerts as well as accepts and responds to status requests. In the various configuration modes the option card
functions can be configured. Option card status requests and configuration commands are made using sequential
quick taps on the Test+Hush button. Responses from the option card include status, white LED flashes and beeps.
Configuration command success is reported by one long flash/beep while command failure is reported by two long
flashes/beeps. The current configuration mode (menu) is reported every 10secs if no command is received. If no
command is received for a period of 2mins while the alarm is in a configuration mode, the option card returns to the
operation mode. The modes are navigated as follows:
Detailed information regarding the mode options follows:
1 Tap
3 Tap
Operation
(1 flash every 5m)
Configuration
(2 flash, 2 beep)
Radio Interlink Configuration
(3 flash, 3 beep)
Auto Test Configuration
(4 flash, 4 beep)
4 Tap
1 Tap
2 Tap
4 Tap
4 Tap
4 Tap
2 Tap
Radio
Interlink
Node
Type +
Built
Node
Count
Auto
Test,
Time
from
Now
Add Radio Node / Build Radio Network
(5 flash, 5 beep)
1 Tap
4 Tap
Initiate
Silence
+ Alert
Status

SmokeSight SS10LNAN V0.5
Page 5
Operation Mode
Command
(Taps)
Description
Response
(White LED Flashes, Beeps)
0
Operation Mode Active
1flash every 300sec
0
Option Card Alert, Refer to Option Card Trouble Shooting
flash + beep every 60sec
2
Radio Interlink, Node Type (master = 1 Beep/Flash for 3secs or slave =
1 Beep/Flash for 1sec) + Built Node Count (node count = number of
Beeps/Flashes). If no network 2 long Beep/Flash
Node Type + Built Node Count
3
Auto Test, Time from Now
Days, Hours
4
Configuration Mode
-
Configuration Mode
Command
(Taps)
Description
Response
(White LED Flashes, Beeps)
0
Configuration Mode Active
2flash + 2beep every 10sec
1
Radio Interlink, Configuration Mode –Requires Radio Interlink Switch
= ON
-
2
Auto Test, Configuration Mode - Requires Auto Test Switch = ON
-
3
Spare
-
4
Return to Operation Mode
-
5,5
Return to Factory Defaults
-
Radio Interlink Configuration Mode
Command
(Taps)
Description
Response
(White LED Flashes, Beeps)
0
Radio Interlink, Configuration Mode Active
3flash + 3beep every 10sec
1
Add Radio Node / Build Radio Network Mode
-
2,2
Remove Slave Radio Node (not for removal of this node)
-
3,3
Delete Radio Network
-
4
Return to Operation Mode
-
Add Radio Node / Build Radio Network Mode
Command
(Taps)
Description
Response
(White LED Flashes, Beeps)
0
Add Radio Node / Build Radio Network Mode Active
5flash + 5beep every 10sec
4
Return to Operation Mode
-
Auto Test Configuration Mode
Command
(Taps)
Description
Response
(White LED Flashes, Beeps)
0
Radio Interlink, Configuration Mode Active
4flash + 4beep every 10sec
1
Weekly Frequency –Following 1 long flash beep, Tap 1,2,3
-
2
Days from Today –Following 1 long flash beep, Tap 1 to 7
-
3
Hours from Now –Following 1 long flash beep, Tap 1 to 24
-
4
Return to Operation Mode
-

SmokeSight SS10LNAN V0.5
Page 6
Enable Switches
Some functions require activation using enable
switches accessible through the base of the smoke
alarm. Following activation of each function using the
enable switches, configuration of the function is
performed using the Test+Hush button and white LED
to navigate the applicable configuration mode.
Changing of any switch will require removing power to
the option card for 1min before repowering.
Switch Assignment
Switch
Function
1
Radio
Interlink
2
Auto Test
3
Spare
4
Spare
Troubleshooting
If the option card is unresponsive to a tap of the Test+Hush button ie no white LED flash or beep then install/replace
the option card batteries. An active alert is reported every 5mins in operation mode. Also, 1 Tap of the Test+Hush
button will report the active alert. Following a 1 tap, 1 long LED flash/beep followed by the active alert is reported
and beeps are silenced for 8 hours. Another 1 tap during this silence period will report the active alert again and
restart the 8 hour silence period. The 8 hour silence period is not terminated if the active alert clears.
ALERT
CAUSE
REMEDY / ACTION
1 White LED
Flash/Beep
Low battery
warning.
Replace the 2xAA 1.5VDC batteries. Press the Test+Hush button to silence the
low battery chirp for up to 8 hours.
2 White LED
Flashes/Beeps
Radio Interlink
Loss (Slave Lost)
–After < 30mins
Where N = number of Radio Interlinked nodes, if:
N-1 nodes report 3 White LED Flashes/Beeps = Perform a ‘Return to Factory
Defaults’ on all alarms and remove their option card batteries. Then, rebuild
the radio interlink network using the ‘Initial Setup’ process.
Less than N-1 nodes report 3 White LED Flashes/Beeps = Perform a ‘Return
to Factory Defaults’ on the lost slave alarm(s) (2 White LED Flashes/Beeps)
and remove their option card batteries. Then re-add them to the network
using the ‘Add Radio Node’ process.
If unsuccessful, relocate the alarms closer to each other and repeat the process.
3 White LED
Flashes/Beeps
Radio Interlink
Loss (Master or
Network Lost) –
After < 10mins
4 White LED
Flashes/Beeps
Auto Test Fail
Replace the smoke alarm. Alternatively, press the Test+Hush button and if the
smoke alarm sounds, disable Auto Test and perform manual tests for the
remaining life of the alarm.
Radio Interlinked Smoke Alarms
Interlinking smoke alarms ensures that if one alarm senses smoke, all of the alarms connected to the radio network
will operate (alarm). The smoke alarm, radio interlink is a separate network that the smoke alarms establish. A
problem with a Wi-Fi network, for instance, will not affect operation of the radio interlink. The radio interlink,
enable switch is required to be switched ON to allow network configuration and operation of each alarm that will be
connected to the radio link network. Once the radio interlink network has been configured, it is saved internally such
that replacing option card batteries will not result in loss of the configuration. Access to Radio Interlink,
Configuration Mode is only possible if the Radio Interlink switch is switched to ON. The radio interlink network
comprises one master node and one or more slave nodes. The node type (master = 1 Beep/Flash for 3secs, slave = 1
Beep/Flash for 1sec) followed by built node count (node count = number of Beeps/Flashes) can be determined in the
operation mode. Failure of any node will not prevent alarm transmission as the network is self-healing.
Initial Setup
1. Switch on/Confirm that the Radio Interlink switch is set to ON. Refer to Configuration Switches for details.
Enable Switches

SmokeSight SS10LNAN V0.5
Page 7
2. Before powering any smoke alarm, place all smoke alarms and their two AA option card batteries on a table in
readiness for radio interlink, network setup.
3. Apply option card power to the first smoke alarm by inserting its
batteries into the top battery bay of the smoke alarm. The alarm will
listen for a network that is in ‘Add Radio Node / Build Radio Network
Mode’ for 30secs during which the white LED will flash every 2secs.
If a network is not detected, this alarm will allocate a unique Home
ID to this network and assign itself as the master node. It will then 1
Beep/Flash for 3secs confirming that it has established a network as
the master and enter ‘Add Radio Node / Build Radio Network Mode’
indicated by 5flash + 5beep every 10secs.
4. Apply option card power to the second smoke alarm by inserting its option card batteries into the top battery
bay of the smoke alarm within 2mins of the previous node being established. This slave node will then 1
Beep/Flash for 1sec confirming that it has joined the network as a slave and enter ‘Add Radio Node / Build Radio
Network Mode’ indicated by 5flash + 5beep every 10secs.
5. Repeat step 4 above on the next alarm, and each subsequent alarm, on your network taking care to only apply
power to each alarm following confirmation that the previously powered alarm has joined the network as a
slave.
6. Once all alarms have been configured they will all be placed into ‘Operation Mode’ 2mins after the last alarm has
joined the network as a slave or by 4Tap of any node’s Test+Hush button to exit ‘Add Radio Node / Build Radio
Network Mode’. On any network alarm confirm that the built node count reported in ‘Operation Mode’ agrees
with your expected node count.
Configuration after Initial Setup
Build Radio Network
If you are powering up your smoke alarm and setting up the radio interlink network for the first time use the ‘Initial
Setup’ above procedure. Use this procedure if your network is not functioning correctly and it is not convenient to
perform individual ‘Return to Factory Defaults’ on each smoke alarm eg the smoke alarms are mounted on a high
ceiling. ‘Return to Factory Defaults’ would allow the ‘Initial Setup’ procedure to be repeated. It is assumed that the
Radio Interlink switch is set to ON for the smoke alarm(s) requiring this function.
1. Confirm that either no or only one network exists by proceeding to each smoke alarm and securing its node type
+ built node count. From ‘Operation Mode’ this can be achieved by 2Tap of the Test+Hush button. Any alarm
reporting a node count less than another alarm’s node count should have its network deleted using ‘Delete
Radio Network’. Alarms reporting only one node do not belong to a network so they don’t need to be deleted.
2. At any smoke alarm select ‘Add Radio Node / Build Radio Network Mode’. From ‘Operation Mode’ this can be
achieved by 4Tap, 1Tap, 1Tap of the Test+Hush button. The alarm will listen for a network that is in ‘Add Radio
Node / Build Radio Network Mode’ for 30secs during which the white LED will flash every 2secs. If a network is
not detected, this alarm will allocate a unique Home ID to this network and assign itself as the master node. It
will then 1 Beep/Flash for 3secs confirming that it has established a network as the master and enter ‘Add Radio
Node / Build Radio Network Mode’ indicated by 5flash + 5beep every 10secs. If a network is detected but this
alarm is not a member, this slave node will then 1 Beep/Flash for 1sec confirming that it has joined the network
as a slave and enter ‘Add Radio Node / Build Radio Network Mode’ indicated by 5flash + 5beep every 10secs. If
this alarm is already part of the network it will simply enter ‘Add Radio Node / Build Radio Network Mode’
indicated by 5flash + 5beep every 10secs.
3. Proceed to the next alarm that is not indicating it is active in ‘Add Radio Node / Build Radio Network Mode’
indicated by 5flash + 5beep every 10secs and select ‘Add Radio Node / Build Radio Network Mode’. From
‘Operation Mode’ this can be achieved by 4Tap, 1Tap, 1Tap of the Test+Hush button within 2mins of the

SmokeSight SS10LNAN V0.5
Page 8
previous node being established. This slave node will then 1 Beep/Flash for 1sec confirming that it has joined
the network as a slave and enter ‘Add Radio Node / Build Radio Network Mode’ indicated by 5flash + 5beep
every 10secs.
4. Repeat step 3 above on the next alarm, and each subsequent alarm, on your network taking care to only add
each alarm following confirmation that the previously powered alarm has joined the network as a slave.
5. Once all alarms have been configured they will all be placed into ‘Operation Mode’ 2mins after the last alarm has
joined the network as a slave or by 4Tap of any node’s Test+Hush button to exit ‘Add Radio Node / Build Radio
Network Mode’.On any network alarm confirm that the built node count reported in ‘Operation Mode’ agrees
with your expected node count.
Add Radio Node
This function adds a new alarm node to an existing network. Refer to ‘Initial Setup’ or ‘Build Radio Network’ if you
are setting up an entire network.
1. Before powering the smoke alarm that you wish to add, select ‘Add Radio Node / Build Radio Network Mode’ on
any networked alarm. From ‘Operation Mode’ this can be achieved by 4Tap, 1Tap, 1Tap of the Test+Hush
button. All alarms on the network will enter ‘Add Radio Node / Build Radio Network Mode’ indicated by 5flash +
5beep every 10secs.
2. Apply option card power to the new smoke alarm by inserting its option card batteries into the top battery bay
of the smoke alarm within 2mins of all network alarms entering ‘Add Radio Node / Build Radio Network Mode’.
This new slave node will then 1 Beep/Flash for 1sec confirming that it has joined the network as a slave and
enter ‘Add Radio Node / Build Radio Network Mode’ indicated by 5flash + 5beep every 10secs.
3. Repeat step 2 above on the next alarm, and each subsequent alarm, on your network taking care to only apply
power to each alarm following confirmation that the previously powered alarm has joined the network as a
slave.
4. Once all alarms have been configured they will all be placed into ‘Operation Mode’ 2mins after the last alarm has
joined the network as a slave or by 4Tap of any node’s Test+Hush button to exit ‘Add Radio Node / Build Radio
Network Mode’.On any network alarm confirm that the built node count reported in ‘Operation Mode’ agrees
with your expected node count.
Remove Slave Radio Node
This function removes an existing alarm node from an existing network. First check the Node Type (master or slave)
of all of the nodes that you wish to remove. From ‘Operation Mode’ this can be achieved by 2Tap of the Test+Hush
button. If one of the nodes you wish to remove is the master you will need to perform ‘Delete Radio Network’.
1. If the existing alarm or alarms that you wish to remove are functional perform a ‘Return to Factory Defaults’ on
those alarms only. From Operation Mode this can be achieved by 4Tap, 5Tap, 5Tap of the Test+Hush button on
those alarms to be removed only.
2. Remove power to the existing alarm or alarms that you wish to remove from the network.
3. On any remaining smoke alarm select ‘Remove Slave Radio Node’. From ‘Operation Mode’ this can be achieved
by 4Tap, 1Tap, 2Tap, pause, 2Tap of the Test+Hush button. The network will then check to see which alarm
nodes are active and will remove any inactive alarm nodes from the network. This alarm only will remain in
‘Radio Interlink Configuration Mode’ as indicated by 3flash + 3beep every 10secs.
4. This smoke alarm will be placed into ‘Operation Mode’ 2mins after the last tap of the Test+Hush button or by
4Tap of the Test+Hush button. On any network alarm confirm that the built node count reported in ‘Operation
Mode’ agrees with your expected node count.
Delete Radio Network
This function deletes an existing radio interlink network.

SmokeSight SS10LNAN V0.5
Page 9
1. Select ‘Delete Radio Network’ on any networked alarm. From ‘Operation Mode’ this can be achieved by 4Tap,
1Tap, 3Tap, pause, 3Tap of the Test+Hush button. The master node will then remove all alarm nodes, including
itself from the network. All alarms will remain in ‘Radio Interlink Configuration Mode’ as indicated by 3flash +
3beep every 10secs.
2. All smoke alarms will be placed into ‘Operation Mode’ 1hr after the last tap of the Test+Hush button or by 4Tap
of the Test+Hush button. On any network alarm confirm that the built node count reported in ‘Operation Mode’
agrees with your expected node count.
Auto Test
The Auto Test function provides scheduled, automatic testing of the smoke alarm. Testing consists of momentarily
simulating smoke internal to the smoke alarm which activates the smoke alarm’s siren. The option card listens for
the correct smoke alarm tone and reports an option card alarm if the test failed. The test establishes, on a regular
basis, that the smoke alarm’s smoke sensor, controller and siren are functional. Test duration is 5secs and can be
configured to be performed at a convenient time. The Auto Test establishes that only the local smoke alarm, on
which the test is performed, is functional. While interlinked alarms may also sound, Auto Test does not confirm
operation of interlinked smoke alarms. Access to Auto Test, Configuration Mode is only possible if the Auto Test
switch is switched to ON.
Setup
1. Switch on/Confirm that the Auto Test switch is set to ON. Refer to Configuration Switches for details. The
factory default, test settings are every two weeks from the day and time that the option card is first supplied
with power. Continue with the following steps only if you wish to change Auto Test times.
2. Select ‘Auto Test Configuration Mode’ - From Operation Mode this can be achieved by 4Tap, 2Tap of the
Test+Hush button. Confirmation of this mode is reported by 4flash+4beep.
3. If you wish to alter the test ‘Frequency’ 1Tap, followed by 1Tap for every week, 2Tap for every two weeks, 3Tap
for every four weeks.
4. If you wish to alter the test day ‘Days from Now’ 2Tap, followed by 1Tap for tomorrow, 2Tap for two days time
up to 7Tap for the current day ie 0 days from now.
5. If you wish to alter the test hour ‘Hours from Now’ 3Tap, followed by 1Tap for 1 hour from now, 2Tap for two
hours from now up to 24Tap for the current hour ie 0 hours from now.
6. The smoke alarm will be placed into ‘Operation Mode’ 2mins after the last tap of the Test+Hush button or by
4Tap of the Test+Hush button. Confirm that the Auto Test Time from Now reported in ‘Operation Mode’ agrees
with your expected test time.
Example
Now: 8am, Tuesday
Desired Auto Test Time: 12 Noon, Friday, Fortnightly
Configuration: Frequency = 2Tap (Fortnightly)
Days from Now = 3Tap (Tuesday to Friday = 3 days)
Hours from Now = 4Tap (8am to 12 Noon = 4 hours)
Confirmation: 3 beep/flash, 4 beep/flash (3 days from today, 4 hours from now)
Clap Silence
If the smoke alarm is in alarm state, two loud hand claps in quick succession immediately below the alarm is
equivalent to pressing the Test+Hush button on that alarm. An alarm in alarm state is evidenced by its red LED
flashing rapidly. As clap volume and timing may vary, you may need to repeat clap silence more than once. The
alarm must incorporate an option card for clap silence to function.

SmokeSight SS10LNAN V0.5
Page 10
Escape Lighting
If the smoke alarm is in alarm state or receives an interlink signal from a smoke alarm that is in alarm state, the
option card, white LED flashes in high intensity mode. This feature assists evacuation by illuminating the escape path
or could be used to better signal an alarm to a hearing impaired resident.
Replacing the Option Card Batteries
The power to the smoke alarm option card is supplied by two AA 1.5VDC alkaline
batteries, located in the top battery bay of the smoke alarm. The batteries should
last a minimum of 5 years under normal operating conditions. If you experience
white LED flash/beep refer to Troubleshooting above. It is recommended to
replace the batteries on a memorable day eg 1st April, April Fool’s Day.
RECOMMENDED BATTERIES: Energizer E91, Duracell MN1500, Fujitsu LR6
TEST THE OPERATION OF THE SMOKE ALARM BY PRESSING THE TEST+HUSH
BUTTON AFTER BATTERY REPLACEMENT
Smoke Alarm
This section relates to smoke alarm operation only. For option card operation, refer above to the option card
section.
Operation
Once power is supplied, the smoke alarm is operational. If smoke is detected the alarm will sound and the red LED
will flash rapidly. This will continue until the air is cleared of smoke. During normal operations the red LED flashes
once every 5mins and 45secs to indicate that the smoke alarm and battery backup is functional.
When the Alarm Sounds
1. Alert small children in the home.
2. Leave immediately by your plan of escape. Don’t waste time getting dressed or picking up valuables.
3. When leaving, don’t open any inside door without first feeling its surface. If hot, or if you see smoke seeping
through cracks, don’t open that door! Instead, use your alternate exit. If inside the door is cool, place your
shoulder against it, open it slightly and be ready to slam it shut if heat and smoke rush in.
4. Stay close to the floor if air is smoky. Breathe shallowly through a wet cloth if possible.
5. Once outside, go to your selected meeting place and make sure everyone is there.
6. Call the Fire Brigade from your neighbour’s home - not from yours!
7. Don’t return to your home until officials say that it is safe to do so.
For further information on fire safety contact your local Fire Brigade.
Testing
TEST THE SMOKE ALARM ONCE PER MONTH TO ENSURE CORRECT OPERATION. Test by pushing the Test+Hush
button on the smoke alarm until the alarm sounds. The alarm will sound if all electronic circuitry, siren and battery
are functional. Any Interlinked alarms will also sound. If no alarm sounds, remove the smoke alarm from its base and
confirm that the Smoke Alarm Power Switch is ON indicated by the symbol ‘I’. If the Smoke Alarm Power Switch is
ON and the alarm still doesn’t sound, replace the smoke alarm. If the smoke alarm is installed in a mobile home, test
weekly and after every journey. After the Test+Hush button has been pressed, wait 10mins before any additional
testing is conducted to avoid any false alarm responses as the alarm is in reduced sensitivity mode during this
period. Refer to ‘Hush‘.

SmokeSight SS10LNAN V0.5
Page 11
IMPORTANT: If premises are unoccupied for a period of time (more than a few days) then a battery test should be
undertaken upon return. If the low battery warning sounds, test and replace the battery if necessary.
Never use an open flame of any type to test your alarm. Check that all interlinked smoke alarms operate during
the test.
Hush
This smoke alarm has a built-in Hush feature incorporated into the Test button. If cooking or other non-hazardous
sources cause the alarm to sound, it can be temporarily silenced by pressing the Test+Hush button. The alarm then
enters a low sensitivity period for 9mins. If the smoke density increases during this period from a smoke or fire
event, the unit will go into alarm mode.
Before using the alarm HUSH feature, identify the source of smoke and be certain that a safe condition exists.
Troubleshooting
CONDITION
CAUSE
REMEDY / ACTION
ALARMS & HUSH
Alarm sounds and the red
LED is blinking rapidly.
Smoke has activated the smoke
alarm
If the cause is unknown, vacate the
building immediately and call the Fire and
Emergency Services.
If the cause is known to be a false alarm,
see “False Alarm” section below.
Alarm sounds but the red
LED if OFF.
Smoke has activated an interlinked
alarm, located somewhere else in
the dwelling.
Smoke alarm is sounding, it
does not stop when
Test+Hush is pressed.
Smoke density is too high, even in
low sensitivity mode, for the Hush
feature to activate.
Smoke alarm is sounding, it
stops when Test+Hush is
pressed.
Low sensitivity mode has been
activated for 9mins
Make sure you are safe and have
eliminated the source of the smoke. See
“False Alarm” section below.
While the Test+Hush
button is pressed the alarm
sounds
The smoke alarm is indicating that
all electronic circuitry, siren and
battery are functional.
Normal test condition. Test regularly to
ensure proper operation
While the Test+Hush
button is pressed the alarm
does not sound
The smoke alarm may not be
operating correctly.
Check that the green LED is ON and the
red LED flashes once every 5mins. If
problem persists contact an electrician for
replacement.
CHIRP
One audible chirp every 40
to 50secs
Low battery warning.
Replace the 2xAA 1.5VDC batteries. Press
the Test+Hush button to silence the low
battery chirp for up to 8 hours.
Three audible chirps every
40 to 50secs
The smoke alarm may not be
operating correctly.
Clean smoke alarm according to
“Maintenance, Repairs and Service”
section. If problem persists contact an
electrician for replacement.
LED
Green LED ON.
240VAC mains supply ON.
Normal operating condition
Green LED OFF.
240VAC mains supply OFF.
Check that mains power is ON. Main
circuit breaker may have tripped. Wiring
could be incorrect.
Red LED flashes every
5mins.
The smoke alarm is functioning
correctly.
Normal operating condition.
Red LED flashes every 8 to
12secs.
The smoke alarm is in low
sensitivity mode. Test+Hush
Wait 10mins to return to normal operating
mode.

SmokeSight SS10LNAN V0.5
Page 12
CONDITION
CAUSE
REMEDY / ACTION
button has been pressed.
OTHER
Smoke alarm will not slide
along the base until it
clicks.
Battery or batteries missing
Install missing battery or batteries
False Alarm
In the event of a false alarm (alarms are sounding without any smoke present):
1. Identify which smoke alarm/s are in alarm state –Look for the alarm/s sounding and with red LED fast flashing.
2. On each smoke alarm in alarm state press the Test+Hush button to silence the alarm
3. Disconnect all smoke alarms in the alarm state by removing them from their base.
4. Clean smoke alarms in accordance with the “Maintenance, Repairs and Service”section.
5. Re-install and test all the smoke alarms.
IMPORTANT: If the above process fails, contact a licenced electrician to investigate.
Maintenance, Repairs and Service
It is recommended that the smoke alarm is inspected monthly to ensure it is free from dirt, dust and insects. The
alarm can be vacuumed or brushed with a soft brush to remove dust, dirt or kitchen grease that has accumulated.
ALWAYS TEST THE SMOKE ALARM AFTER CLEANING.
If the smoke alarm is defective in any way, do not tamper with the smoke alarm. The smoke alarm does not contain
any user-serviceable parts. As the smoke alarm does not contain any radioactive material, disposal with domestic
rubbish is permitted in Australia and New Zealand.
Warranty
Redbusbar Pty Ltd, warrants this product to be free from defects in materials and workmanship for a period of 5
(five) years from the date of installation. Refer to the Redbusbar terms of sale for full warranty conditions
http://www.redbusbar.com/Terms-and-Conditions.html
Redbusbar reserves the right to change specifications, modify designs and discontinue items without incurring
obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this
document are correct, no warranty is given in respect thereof and the company shall not be liable for any error
therein. © Redbusbar 2018. Redbusbar acknowledges that the Activfire Certified logo is a trademark of CSIRO.
Other manuals for SS10LNAN
1
This manual suits for next models
1
Table of contents