Redx RX- 0050 User manual

Lithium Iron Phosphate
Battery System
User Manual
Document Version: 1.1
Issued Date: 2023-03-29
RX- 0050


About This Document
Purpose
Intended Audience
Symbol Conventions
This document describes the RX-0050 Lithium iron phosphate battery system in terms of its
features, performance, working principles, appearance as well as instructions for installation, and
operation and maintenance (O&M).
This document is intended for:
Sales engineers
Technical support engineers
System engineers
Hardware installation engineers
Commissioning engineers
Maintenance engineers
The symbols that may be found in this document are defined as follows.
Indicates a hazard with a high level of risk which, if not avoided, will result in
death or serious injury.
Indicates a hazard with a medium level of risk which, if not avoided, could
result in death or serious injury.
Indicates a hazard with a low level of risk which, if not avoided, could result
in minor or moderate injury.
Indicates a potentially hazardous situation which, if not avoided, could result
in equipment damage, data loss, performance deterioration, or unanticipated
results.
NOTICE is used to address practices not related to personal injury.
Supplements the important information in the main text. NOTE is used to
address information not related to personal injury, equipment damage, and
environment deterioration.
Symbol Description
DANGER
WARNING
CAUTION
NOTICE
NOTICE
Document Version: 1.1
Issued Date: 2023-03-29

REVISION LOG
Version Num. Date Purpose of Revision
2020/12/14 This issue is the first official release.V1.0
Document Version: V1.1
Issued Date: 2023-03-29
2023/03/29 Clarified packaging and cable connections.V1.1

Contents
1 Safety Information....................................................................................1
1.1 General Safety...................................................................................1
1.2 Personnel Requirements...................................................................4
1.3 Electrical Safety.................................................................................5
1.4 Installation Environment Requirements.............................................6
1.5 Mechanical Safety..............................................................................6
1.6 Battery Safety....................................................................................8
1.7 Others................................................................................................11
2 Overview....................................................................................................12
2.1 Product Introduction..........................................................................12
2.1.1 Appearance....................................................................................12
2.1.2 Product Structure........................................................................... 13
2.2 Battery System Specification.............................................................14
2.2.1 Cell Parameters..............................................................................14
2.2.2 Battery Module Parameters............................................................14
2.2.3 Protection Parameters....................................................................15
3 Operations.................................................................................................16
3.2Communication..................................................................................17
3.3Installation..........................................................................................17
4 Routine maintenance...............................................................................19
4.1 Monthly Maintenance........................................................................19
5 Terms.........................................................................................................21
Document Version: V1.1
Issued Date: 2023-03-29
3.1 Storage..............................................................................................16
3.4Powering on.......................................................................................19

1.1 General Safety
Statement
Before installing, operating, and maintaining the equipment, read this document and observe all the
safety instructions on the equipment and in this document.
The "NOTICE", "WARNING", and "DANGER" statements in this document do not cover all the safety
instructions. They are only supplements to the safety instructions. Redx will not be liable for any
consequence caused by the violation of general safety requirements or design, production, and usage
safety standards.
Ensure that the equipment is used in environments that meet its design specifications. Otherwise,
the equipment may become faulty, and the resulting equipment malfunction, component damage,
personal injuries, or property damage are not covered under the warranty.
Follow local laws and regulations when installing, operating, or maintaining the equipment. The
safety instructions in this document are only supplements to local laws and regulations.
1 Safety Information
RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 1
Redx will not be liable for any consequences of the following circumstances:
Operation beyond the conditions specified in this document
Installation or use in environments which are not specified in relevant international or national
standards
Unauthorized modifications to the product or software code or removal of the product
Failure to follow the operation instructions and safety precautions on the product and in this
document
Equipment damage due to force majeure, such as earthquakes, fire, and storms
Damage caused during transportation by the customer
Storage conditions that do not meet the requirements specified in this document

General Requirements
Do not install, use, or operate outdoor equipment and cables (including but not limited to moving
equipment, operating equipment and cables, inserting connectors to or removing connectors from
signal ports connected to outdoor facilities, working at heights, and performing outdoor installation)
in harsh weather conditions such as lightning, rain, snow, and level 6 or stronger wind.
Before installing, operating, or maintaining the equipment, remove any conductive objects such as
watches or metal jewelry like bracelets, bangles, and rings to avoid electric shock.
When installing, operating, or maintaining the equipment, wear dedicated protective gear such as
insulation gloves, goggles, and safety clothing, helmet, and shoes, as shown in the following figure.
Follow the specified procedures for installation, operation, and maintenance.
Before handling a conductor surface or terminal, measure the contact point voltage and ensure
that there is no risk of electric shock.
RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 2

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 3
After installing the equipment, remove idle packing materials such as cartons, foam, plastics, and cable
ties from the equipment area.
In the case of a fire, immediately leave the building or the equipment area, and turn on the fire alarm bell
or make an emergency call. Do not enter the building on fire in any case.
Do not stop using protective devices. Pay attention to the warnings, cautions, and related precautionary
measures in this document and on the equipment. Promptly replace warning labels that have worn out.
Keep irrelevant people away from the equipment. Only operators are allowed to access the equipment.
Use insulated tools or tools with insulated handles, as shown in the following figure.
Do not scratch, damage, or block any warning label on the equipment.
Tighten the screws using tools when installing the equipment.
Do not work with power on during installation.
Repaint any paint scratches caused during equipment transportation or installation in a timely manner.
Equipment with scratches cannot be exposed to an outdoor environment for a long period of time.
Before operations, ensure that the equipment is firmly secured to the floor or other solid objects, such
as a wall or an installation rack.
Do not use water to clean electrical components inside or outside of a cabinet.
Do not change the structure or installation sequence of equipment without permission.

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 4
1.2 Personnel Requirements
Personal Safety
If there is a probability of personal injury or equipment damage during operations on the equipment,
immediately stop the operations, report the case to the supervisor, and take feasible protective measures.
To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telecommunication
network voltage (TNV) circuits.
Do not power on the equipment before it is installed or confirmed by professionals.
Personnel who plan to install or maintain Redx equipment must receive thorough training,
understand all necessary safety precautions, and be able to correctly perform all operations.
Only qualified professionals or trained personnel are allowed to install, operate, and maintain the
equipment.
Only qualified professionals are allowed to remove safety facilities and inspect the equipment.
Personnel who will operate the equipment, including operators, trained personnel, and professionals,
should possess the local national required qualifications in special operations such as high-voltage
operations, working at heights, and operations of special equipment.
Professionals: personnel who are trained or experienced in equipment operations and are clear of
the sources and degree of various potential hazards in equipment installation, operation, maintenance
Trained personnel: personnel who are technically trained, have required experience, are aware of
possible hazards on themselves in certain operations, and are able to take protective measures to
minimize the hazards on themselves and other people.
Operators: operation personnel who may come in contact with the equipment, except trained
personnel and professionals.
Only professionals or authorized personnel are allowed to replace the equipment or components
(including software).

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 5
1.3 Electrical Safety
Grounding
AC and DC Power
ESD
For the equipment that needs to be grounded, install the ground cable first when installing the
equipment and remove the ground cable last when removing the equipment.
Do not damage the ground conductor.
Do not operate the equipment in the absence of a properly installed ground conductor.
Ensure that the equipment is connected permanently to the protective ground. Before operating the
equipment, check its electrical connection to ensure that it is securely grounded.
DANGER
Do not connect or disconnect power cables with the power on. Transient contact between the
core of the power cable and the conductor will generate electric arcs or sparks, which may
cause fire or personal injury.
Before installing or removing a power cable, turn off the power switch.
Before connecting a power cable, check that the label on the power cable is correct.
If the equipment has multiple inputs, disconnect all the inputs before working with the
equipment.
A damaged power cable must be replaced by the manufacturer, service agent, or professionals
to avoid risks.
High voltage operations and installation of AC-powered facilities must be performed by qualified
personnel.
Wear ESD gloves or a well-grounded ESD wrist strap when touching the device or handling boards
or application-specific integrated circuits (ASICs).
When holding a board, hold its edge without touching any components. Do not touch the components
with your bare hands.
Package boards with ESD packaging materials before storing or transporting them.
NOTICE
The static electricity generated by human bodies may damage the electrostatic-sensitive
components on boards, for example, the large-scale integrated (LSI) circuits.

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 6
1.4 Installation Environment Requirements
1.5 Mechanical Safety
Using Ladders
Figure 1-1 wearing an ESD wrist strap
If any liquid is detected inside the equipment, immediately disconnect the power supply and
contact the vendor.
Do not expose the equipment to flammable or explosive gas or smoke. Do not perform any
operation on the equipment in such environments.
The environmental temperature must be between 0 °C and +50 °C, and the relative humidity.
Between 0% and 90% (without condensation).
Install on a sturdy supported surface. Indoor installation only.
Use wooden or fiberglass ladders when you need to perform live working at heights.
When a step ladder is used, ensure that the pull ropes are secured and the ladder is held firm.
Before using a ladder, check that it is intact and confirm its load bearing capacity. Do not
overload it.
Ensure that the ladder is securely positioned. The recommended angle for a ladder against
the floor is 75 degrees, as shown in the following figure. An angle rule can be used to measure
the angle. Ensure that the wider end of the ladder is at the bottom, or protective measures have
been taken at the bottom to prevent the ladder from sliding.

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 7
DANGER
When removing a heavy or unstable component from a cabinet, be aware of unstable or heavy
objects on the cabinet.
NOTICE
Do not drill holes into the equipment. Doing so may affect the electromagnetic shielding of the
equipment and damage components or cables inside. Metal shavings from drilling may
short-circuit boards inside the equipment.
Drilling Holes
Moving Heavy Objects
Obtain the consent from the customer, subcontractor, and Redx before drilling.
Wear goggles and protective gloves when drilling holes.
When drilling holes, protect the equipment from shavings. After drilling, clean up any shavings that
have accumulated inside or outside the equipment.
When climbing a ladder, take the following precautions to reduce risks and ensure safety:
Keep your body steady.
Do not climb higher than the fourth rung of the ladder from the top.
Ensure that your body's center of gravity does not shift outside the legs of the ladder.
When drilling holes into a wall or floor, observe the following safety precautions:

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 8
1.6 Battery Safety
DANGER
Do not expose batteries at high temperatures or around heat-generating devices, such as
sunlight, fire sources, transformers, and heaters. Excessive heat exposure may cause the
batteries to explode.
Do not burn batteries. Otherwise, the batteries may explode.
To avoid leakage, overheating, fire, or explosions, do not disassemble, alter, or damage
batteries, for example, insert sundries into batteries or immerse batteries in water or other
liquids.
Basic Requirements
Be cautious to avoid injury when moving heavy objects.
When moving the equipment by hand, wear protective gloves to prevent injuries.
Move or lift the equipment by holding its handles or lower edges. Do not hold the handles of modules
(such as power supply units, fans, and boards) that are installed in the equipment because they
cannot support the weight of the equipment.
Avoid scratching the case surface or damaging case components and cables during equipment
transportation.
When transporting the equipment using a forklift truck, ensure that the forks are properly positioned to
ensure that the equipment does not topple. Before moving the equipment, secure it to the forklift truck
using ropes. When moving the equipment, assign dedicated personnel to take care of it.
Choose railways, sea, or a road with good condition for transportation to ensure equipment safety.
Avoid tilt or jolt during transportation.
Move a cabinet with caution. Any bumping or falling may damage the equipment.
Before operating batteries, carefully read the safety precautions for battery handling and master the
correct battery connection methods.

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 9
To ensure battery safety and battery management accuracy, use batteries provided with the
UPS by Redx. Redx is not responsible for any battery faults caused by batteries not provided
by Redx.
NOTICE
Wear goggles, rubber gloves, and protective clothing to prevent skin contact with electrolyte in the
case of electrolyte overflow. If a battery leaks, protect the skin or eyes from the leaking liquid. If the
skin or eyes come in contact with the leaking liquid, wash it immediately with clean water and go to
the hospital for medical treatment.
Use dedicated insulated tools.
Move batteries in the required direction. Do not place a battery upside down or tilt it.
Keep the battery loop disconnected during installation and maintenance.
Use batteries of specified models. Using batteries of other models may damage the batteries.
Dispose of waste batteries in accordance with local laws and regulations. Do not dispose of batteries
as household waste. If a battery is disposed of improperly, it may explode.
The site must be equipped with qualified fire extinguishing facilities, such as firefighting sands and
powder fire extinguishers.
Before installing batteries, observe the following safety precautions:
Install batteries in a well-ventilated, dry, and cool environment that is far away from heat sources,
flammable materials, moisture, extensive infrared radiation, organic solvents, and corrosive gases.
Take fire prevention measures.
Place and secure batteries horizontally.
Note the polarities when installing batteries. Do not short-circuit the positive and negative poles of
the same battery or battery string. Otherwise, the battery may be short-circuited.
Check battery connections periodically, ensuring that all bolts are securely tightened.
When installing batteries, do not place installation tools on the batteries.
Battery Installation

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 10
WARNING
Battery Short Circuit
Lithium Battery
DANGER
Battery short circuits can generate high instantaneous current and release a great amount
of energy, which may cause equipment damage or personal injury.
To avoid battery short-circuit, do not maintain batteries with the power on.
The safety precautions for lithium batteries are similar to those for lead-acid batteries except that you
also need to note the precautions described in this section.
Battery short circuits can generate high instantaneous current and release a great amount
of energy, which may cause equipment damage or personal injury.
There is a risk of explosion if a battery is replaced with an incorrect model.
A battery can be replaced only with a battery of the same or similar model recommended by the
manufacturer.
When handling a lithium battery, do not place it upside down, tilt it, or bump it with other objects.
Keep the lithium battery loop disconnected during installation and maintenance.
Do not charge a battery when the ambient temperature is below the lower limit of the operating
temperature (charging is forbidden at 0°C). Low-temperature charging may cause crystallization,
which will result in a short circuit inside the battery.
Use batteries within the allowed temperature range; otherwise, the battery performance and safety
will be compromised.
Do not throw a lithium battery in fire.
When maintenance is complete, return the waste lithium battery to the maintenance office.

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 11
1.7 Others Transport & Long term Storage
Warning & Tips
For long-term storage, a charge-discharge cycle is required every 3 months according to the method
specified in the specification.
When loading and unloading the battery during transportation, please be careful not to drop it, do
not stack more than 6 layers, turn it over, and ensure that the front is facing up.
Please dispose of used batteries in accordance with local laws and regulations, or let the qualified
organization recycle,and do not dispose of batteries as household garbage.
Before using the battery, please read the specification and the warning signs on the surface of the
battery box. Improper use of the battery may cause damage to the battery due to overheating.
Guang Dong Redx Electrical Technology Limited will not be responsible for any accidents caused
by operation not in accordance with the specification. Responsibility, in order to ensure the safe
use and disposal of the battery, please read the operating instructions carefully before use.

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 12
2.1 Product Introduction
2.1.1 Appearance
Figure 2-1 appearance
Battery system
2 Overview

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 13
2.1.2 Product Structure
1. Power port 2.Breaker 3. Start& Status display 4. Communications ports

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 14
2.2 Battery System Specification
2.2.1 Cell Parameters
2.2.2 Battery Module Parameters
Items Parameters
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
10
11
12
Cell type
Nominal voltage
Rated capacity
Rated energy
Internal resistance
Allowed MAX charging current
Recommended charging current
Allowed MAX discharging current
Maximum pulse discharging current
Product name
Model
Rating
Input
Output
Charging Temperature Range
Discharging Temperature Range
Internal resistance
Rated charge voltage
Allowed MAX charging current
Recommended charging current
Allowed MAX discharging current
Weight
IP Class
About:56kg
IP55
14
15
LiFePO4 Battery System
RX-0050
51.2V,100Ah,5.12Kwh
Max 56.8V d.c., 60A
43.2 ~ 56.8V d.c., Max 60A
0°C ~ 45°C
-10°C ~ 55°C
≤20mΩ @1kHz AC
58.4V
60A @ 25±5℃
≤50A
60A @ 25±5℃
Prismatic
3.2V
100AH
320WH
≤0.4mΩ@25℃1kHz AC
1C
≤0.5C
1C @25±5℃,SOC>20%
2C@25±5℃,10s,SOC≥20%
No.
Items ParametersNo.
W:400±2mm
D:620±2mm
H:145±2mm
Dimensions13

RX-0050
Lithium iron phosphate battery system User Manual
Document Version: V1.1
Issued Date: 2023-03-29 15
2.2.3 Protection Parameters
The battery contains a lithium battery protection board, which can monitor the battery operating
status in real time, provide protections such as overcharge, over discharge, overcurrent, and over
temperature when necessary, and cut off the input and output of the power battery for protection
when necessary.
No Items Content Parameters
Over charge1
2
3
4
Over-charge protection for each cell 3.65V
3.45V
Under the release voltage
2.50V
3.15V
Over the release voltage
Discharge or auto release
after 3min
70A,delay time15s
(1string)
Charge or auto release
after 3min
Break protection
Protect@65℃;
Release@55℃;
Protect@-20℃;
Release@-10℃
60A,delay time 15s
(1string)
Over-charge release for each cell
Over-charge release method
Over-discharge protection each cell
Over-discharge release for each cell
Over-discharge release method
Charge over current protection
Charge over current release
Discharge over current protection
Discharge over current release
Short circuit protection
Discharge over temperature protection
Discharge under temperature protection
Over discharge
Over current
Temperature
Table of contents
Other Redx Camera Accessories manuals
Popular Camera Accessories manuals by other brands

ORION TELESCOPES & BINOCULARS
ORION TELESCOPES & BINOCULARS Solar StarSeeker 10382 instruction manual

Panasonic
Panasonic DMW-DCC14 operating instructions

Leica
Leica Digiscoping-Adapter instructions

PhaseOne
PhaseOne H 101 Getting started

uniqball
uniqball UBH Series user manual

Cartoni
Cartoni MAGNUM user manual