Reference TX40 User manual

Operation manual
TX40 and CX40

Product features.............................page 4
Installation, operation & maintenance ........page 6
Product specics ............................page 8
Troubleshooting.............................page 9
Certication ................................page 10
page 2 Operation manual TX40/CX40

Introduction
Congratulations on your choice of hand torch! The TX40 is the
most sophisticated Ex certied torch solution on the market
page 3
Reference Ex Torch and Charger
- designed for hazardous areas
The Reference solution is a multi-
purpose lighting solution that
reduces the need for additional
equipment. The TX40 torch serves
your purpose whether you need
a hand held torch, a separately
positioned light source, or a
permanently installed emergency
light.
Reliable
The patented induction technology
for wireless power transfer eliminates
the conductivity problems
commonly experienced with
saltwater, oil spill and mud exposure.
The technology furthermore allows
the TX40 to be recharged within Zone
1 gas hazardous environments, and
operate under Zone 0 conditions.
Maintenance Free
Intelligent routines regularly perform
tests on both torch and charger to
monitor the system´s condition.
Charging routines are performed at
scheduled intervals to ensure optimal
battery capacity, and maintain long
term durability.
Safe
The REFERENCE torch and charger
solution should be an important part
of your safety program. The equipment
may be sealed with a securing wire
on location, focusing its application
towards emergency lighting. In the
event of a power outage the torch will
automatically turn on to illuminate its
location.

Innovative belt clip
– Improved belt clip functionality allows
torch to be placed upright at various
angles, giving operator both hands free.
Operation Zone 0
– Certied for operation under Zone 0,
1, and 2 conditions, simplifying use in
gas hazardous environments!
3mm hardened glass
– 3mm hardened scratch resistant
glass protects optical components,
maintaining light intensity and beam
conformity.
Product features
Latest LED technology combined with 4°
lens
– 3rd generation LED and the embedded
4º lens optimize battery utilization while
producing a bright and uniform beam of
light on any targeted surface.
Low battery indication
– The built-in low battery procedure
reduces light intensity to 30%, indicating
that recharge is needed and ensuring
ecient utilization.
Intelligent battery routines
– Scheduled charging routines and battery
monitoring ensure optimal capacity and
long term durability.
Textured rubber for extra grip
– Main body shaft is covered with textured
rubber, providing a rm and comfortable
grip under slippery conditions such as rain,
oil, mud etc.
6
12
7
5
4
3
1
2
3
4
5
6
7
page 4 Operation manual TX40/CX40
Operation

Permanent maintenance free battery
solution
– With the sealed and self-maintained
rechargeable battery feature, general
maintenancecostisreducedwhileeliminating
the need for spare parts.
Low voltage shutdown
– A low voltage shutdown procedure is
automatically performed in the event of deep
discharge, preventing permanent damage to
internal batteries.
Seal point for emergency use
– Optional safety feature allows torch and
charger to be sealed together with a securing
wire,enablingapplicationtowardsemergency
lighting equipment.
Emergency light activation
– Embedded safety routine automatically
activates torch in the event of a power outage
to illuminate its location.
Torch and charger condition
indicator
– Intelligent routines regularly perform
specictestsonbothtorchandchargerto
monitorthesystemsconditionandreport
any irregularities.
Zone 1 certied weatherproof
charging system
–Galvanic powertransferallowscharging
withoutanymetallicconnection,enabling
torch to be recharged within Zone 1
conditions,whileeliminatingcorrosionand
otherconductivityissues due to water,oil,
mud etc.
Attach point for safety wire
– Firm attach point for safety wire, giving
the option of securing the torch against
accidental free fall while mobile.
123
4
5
76
1
2
3
4
5
6
7
page 5
Maintenance & Safety

• Connect supplied cable to power source.
• Connect grounding cable where applicable.
• Termination of the power cord must be in an ATEX
certied junction box and as shown in illustration.
1
2
3
4
• Condition LED will start ashing green after
approximately 5 seconds when charging process has
been initialized.
• Continuous green LED indicates a fully recharged and
operational torch.
Condition LED
Torch insertion
Power connection
Carger mount
Installation, operation & maintenance
• Fasten charger with 4xM5 screws or
stud bolts using a torque of 1-2 Nm.
• Insert torch into charger as illustrated. The at surface
of the torch must face towards the charger.
page 6
Note:
Avoid installation causing continuous exposure to direct
sunlight preventing visual inspection of condition LED.
Note:
Placingmetalobjectsbetweentorchandcharger
surface may obstruct the charging process.

5
• Activate torch by moving switch knob
forward as shown in illustration.
6
Certication tag
Sample: Torch TX40 Sample: Charger CX40
7
8
General maintenance
Bracket option
Torch activation
page 7
Note:
DuetotheReferencetorchilluminationintensity,
direct exposure to eyes is not recommended.
Warning:
Do not open or disassemble torch within a gas
hazardous environment. Any disassembling of
Reference products will aect warranty.
• Place support bracket within the illustrated
angles to enable xed upright lighting.
• As required maintenance, inspect torch and charger regularly for physical damage. When
cleaning Reference products, wipe torch and charger with soap and a clean cloth.

Product specics
page 8 Operation manual TX40/CX40
Model name
Torch TX40
Charger CX40
Weight
Torch 600g
Charger 600g
Measurements
(mm)
Torch 230x70x70
Charger 185x65x60
Power cable lenght 2 m
Charger input voltage 100-250VAC 50/60Hz 1.0A max
Certication code
Torch II 1 G Ex ia IIC T3
Charger II 2 G Ex mb II T4
Area classication
(gas)
Torch Zones 0, 1 & 2 - Gas groups IIA, IIB, IIC
Charger Zones 1 & 2 - Gas group II
Ambient temperature -40/60ºC
Ingress protection (IP) 67
Light type, eect High eciency LED, 3 watts
Lens Polycarbonate with 4° spread
Performance (1m) 200 lm
Operation time Approx 5 hours
Recharge time Approx 3 hours (80% in 2 hours)
Operating life More than 1000 recharge cycles

Troubleshooting
No light produced when torch
is turned on
The torch may be completely discharged. Insert torch into
charger to initiate recharge process.
Torch automatically lights up
when inserted into charger
Charger may not receive current from its power source
which results in torch activating emergency mode. Check
power source, connectors, and cable for damage.
Green LED ashes when torch
is placed in charger
Flashinggreenlightindicatesthatbatteriesarecurrentlybeing
recharged. LED will stop ashing and turn continuous green
when batteries are fully recharged.
Red LED ashes when torched
is placed in charger
Flashing red light indicates that the torch does not receive
correct voltage from the charger. Check that the torch has
been correctly inserted into charger, and that there is no
signicant buildup of mud or dirt obstructing the charging
process.
Red LED is activated when
torch is placed in charger
Continuousredlightindicatesanautomaticmaintenancetest
has failed.Try reinserting torch into charger.Torch should be
replaced if problem persists.
In the event of any problems still present after closely reviewing the above table, or other
irregularitiesoccuringduringoperationandhandling,pleasecontactReferencehelpdeskforsupport.
P.O. Box 791 Stoa,
NO-4809 Arendal,
Norway
Phone: +47 37 06 37 00
Email: reference@hernis.no
www.reference.no
page 9

page 10 Operation manual TX40/CX40
Notes

page 11

P.O. Box 791 Stoa,
NO-4809 Arendal,
Norway
Phone: +47 37 06 37 00
Email: referenc[email protected]
www.reference.no
This manual suits for next models
1
Table of contents
Popular Flashlight manuals by other brands

Celestron
Celestron POWER TANK 18774 quick guide

AccuLux
AccuLux HL10 EX operating instructions

Abicor Binzel
Abicor Binzel MB ERGO 14 operating instructions

Weather X
Weather X WF382R user guide

Carson
Carson RedSight LightProT SL-33 quick start guide

Lincoln Electric
Lincoln Electric CALIBER K4843-18 Operator's manual