Regada DMS3 Manual

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
1
Setup ofparameters
using buttons controlunit
MenuLED
Register errorsandwarnings
Appendix
74 105302

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
2
1. Table ofcontents
1. TABLEOF CONTENTS................................................................................................................................2
2. PARAMETERSSETUP.................................................................................................................................3
3. SETUPOFPARAMETERSUSINGBUTTONSCONTROL UNIT........................................................................4
3.1. USEDSYMBOLSFOR LEDINDICATION...............................................................................................................5
3.2. MENULED-ENTERTHE MENUAVAILABLEWITHOUTPASSWORD .......................................................................5
3.3. MENULED-ENTERTHE MENUPROTECTEDPASSWORD....................................................................................5
3.4. MENULED-OPTION MENUAND PARAMETERS ..............................................................................................6
3.5. MENULED-CHANGEAND RECORD OFPARAMETERS.........................................................................................7
3.6. MENULED–INACCESSIBLEPARAMETER.........................................................................................................8
3.7. MENULED–TEMPORARYINACCESSIBLEPARAMETER........................................................................................8
3.8. MENULED-MENUEXIT............................................................................................................................8
3.9. PARTICULARPARAMETERSSETUP.....................................................................................................................9
3.9.1. Limit position Csetup......................................................................................................................9
3.9.2. Limit position “O” setup..................................................................................................................9
3.10. REGULATOR CALIBRATION........................................................................................................................10
3.11. MENU................................................................................................................................................11
3.11.1. MENU1–Torque..........................................................................................................................11
3.11.1.1. MENU 1 –Torque C...............................................................................................................................11
3.11.1.2. MENU 1 –Torque O..............................................................................................................................12
3.11.2. MENU2–End position..................................................................................................................13
3.11.3. MENU3–Torque blockage...........................................................................................................14
3.11.3.1. MENU 3 –Timesetup fortorqueblockage...........................................................................................14
3.11.3.2. MENU 3 –Setup positionfortorque Oblockage..................................................................................15
3.11.3.3. MENU 3 –Setup positionfortorque C blockage...................................................................................15
3.11.4. MENU4–RelayREADY.................................................................................................................16
3.11.5. MENU5–Relay1.. 5....................................................................................................................17
3.11.5.1. MENU 5 –Relay 1..5..............................................................................................................................17
3.11.5.2. MENU 5 –PositionRelay 1..5................................................................................................................18
3.11.6. MENU6–CPT...............................................................................................................................19
3.11.7. MENU7-Regulation, Analog controlsignal.................................................................................20
3.11.7.1. MENU 7 –Regulation............................................................................................................................20
3.11.7.2. MENU 7 –Analogcontrolsignal............................................................................................................21
3.11.8. MENU8–Dead zone.....................................................................................................................22
3.11.9. MENU9–Failure..........................................................................................................................23
3.11.9.1. MENU 9 - Failurereaction.....................................................................................................................23
3.11.9.2. MENU 9 –Safeposition.........................................................................................................................24
4. REGISTERERRORSANDWARNINGS........................................................................................................25
5. SYSTEMDMS3-ELECTRONIC CONTROL SYSTEMFOR CONTROLLINGTHE ELECTRIC ACTUATORS(NEXT
EA)-THEBASICFEATURESANDOPTIONS......................................................................................................28

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
3
2. Parameterssetup
Blink
Menu Parameter Button
PAR
SEL
Parameters value
PositionC
C
SetuptheactualpositionastheClimit position
PositionO
O
SetuptheactualpositionastheOlimit positio
n
Calibrationcontroller
P
Start thecalibrationcontroller
C
1
Torque C
O
2
Torque O
1 Torque
P
5
-
10
50
-
100 %(by 10 %),(50 and 60%depend onpar. Torque min.)
1
Torque O+Torque C
2
Torque C +PositionO
3
PositionC +Torque O
2 End position P
4
PositionO+PositionC
C
Setuptheactualpositionfortorque C blockage
O
Setuptheactualpositionfortorque Oblockage
P
0
-
20
Timeset
-
upforTorque blockage
3 Torque blockage
C+O
Default setupof timean
dpositionblockage
1
Errors
2
Errors orwarning
3
Errors ornot remotecontrol
4 Relay ready P
4
Errors orwarning ornot remotecontrol
C,O
1
-
5
Relay1
-
5 selection,setup theactualposition
inparameter position Relyay
1..5
C+O
Default setupof Relay 1
-
5 functions and positions
1
Disabled
2
PositionO
3
PositionC
4
Torque O
5
Torque C
6
Torque OorTorque C
7
Torque OorPositionO
8
Torque C orPositionC
9
Open
10
Close
11
Move
12
Move
–
blink / Move
-
twinkler
13
To position
14
From position
15
Warning
16
Control
–
remote
17
Control
–
local
5 Relay 1 - 5
P
18
Control
–
off
1
4
-
20 mA
6 CPTtransmitter P
2
20
-
4 mA
C
1
Control
1
1
2P
2
1
3P
P
3
1
3P/2PI2
O
2
Analogcontrolsignal
1
2
4
-
20 mA
2
-
10 V
2
2
20
-
4 mA
10
-
2 V
3
2
0
-
20 mA
0
-
10 V
4
2
20
-
0 mA
10
-
0 V
5
2
4...12 mA
-
6
2
12...20 mA
-
7
2
20...12 mA
-
7 Control,Analog
controlsignal
P
8
2
12...4 mA
-
8
Deadzone
P
1 %to10 %(by 1 %)
C,O
Setuptheactualposition(Open,Close)
1
Open
2
Close
3
Stop
9 Failure reaction P
4
Safeposition

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
4
3. Setupofparameters usingbuttonscontrolunit
MENULED
oMenu will prevent EAnormaloperation.
oIfany buttonisnotpressedduring4minutes and communication throughthe
seriallineisabsent, themenuisautomatically terminatedand thesystem returnsto normal
operation.
oMenu canbemadeprotectedby thepassword(parameter Password)-accessto the
menu isprotectedby thepassword.
oThemenu ismodifiedby current configuration ofthesystem; some parametersare
temporarily unavailable-inaccessibleparameter.
Entry ofparameterscanbelimitedby theaccess permission(parameter Access), parametersareunavailable-
temporarily unavailableparameters.
LED
§ERR - errorssignaling
§OPEN,MENU
oOPEN -activesignalontheinput OPEN
oMENU-option inMENULED
§CLOSE, PAR
oCLOSE-activesignalontheinput CLOSE
oPAR -activesignalontheinput I1
§I1,SEL
oI1 -activesignalontheinput I1
oSEL-option inMENULED
§I2 -activesignalontheinput I2
§PWR -enabledpowersupply +5V
Controlunitwithsetupbuttons
BUTTON
MENU
SETTINGBUTTONP
SETTINGBUTTONC
SETTINGBUTTON
O
LED
ERROR
LEDOPEN
LEDMENU
LEDCLOSE
LEDPAR
LEDI1
LEDSEL
LEDI2
LEDPOWER
COMMUNICATIONCONNECTOR
red ERR
green
red CLOSE
yellow I1
OPEN
yellow I2
MENU
PAR
SEL
green PWR

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
5
3.1. Used symbolsforLEDindication
3.2. MENULED-enter theMENUavailable without password
Pressand hold
MENUbutton. MessageMENUappears
and LEDERR and MENU
lights.
Release thebutton.
MENU P O C
3.3. MENULED-enter theMENUprotected password
Pressand holdMENUbutton.
DisplayedwritingBLOC.
Currency isprotects
passwordisaccesibleonly
throughPCorLCD.
Release thebutton.
MENU P O C
Message1M appears.ERR
LEDlightsand MENULED
blinks1x.
ERR LEDlights
throughpresencein
theMENU.

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
6
3.4. MENULED-optionMENUandparameters
Repeatedly press the
buttonMENUinthe
short intervals
GreenLEDmenu increasesblinkingor
messages aredisplayedwithanother
numbers
By the somemenu Shortly
press thebuttonOorC
and chosenparameter
.....
Choose parameterare
indicated LED SEL and by
decimalpoints.
Parametervalueis
expressedby RedLEDRAR -
numberofblinksorby
messageshowedondisplay

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
7
3.5. MENULED-changeandrecordofparameters
Repeatedly press the
buttonPintheshort
intervals.
MENULED MENU (green)blinksa menu
numberand LEDPAR (red)blinks
parametersvalueormessagewith
parametervalueisappeared.
Recorda new valueby
pressingand holding
Pbutton.
.....
Holdthebuttonuntil the
PAR LEDs(red)ordecimal
pointslighting.
Release thebutton. Recordedvalueisdisplayed.
MENU P O C

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
8
3.6. MENULED–inaccessible parameter
§Unlessareinthemenu ondisplay displayed2dash, parameterit's no useforactualsystem
configuration, istemporary inaccessible
3.7. MENULED–temporaryinaccessible parameter
§Unlessarethey by therecordparametersinthemenu ondisplay displayed2dash, parameteris
inaccessibleto record
§Accessingparameterispossibleto changeparameteraccessby programEHLExplorerwith
correspondinglegitimate(HWkey).
3.8. MENULED-MENUexit
Pressand hold
MENUbutton.
Recordisconfirmedby
MENULED(green)or
followingmessage.
Release thebutton.
MENU P O C

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
9
3.9. Particular parameterssetup
3.9.1. LimitpositionCsetup
Setup a new position manually
orby localcontrol. Recorda new valueby
pressingand holding
Cbutton.
Holdthebuttonuntil the
MENUand PAR LEDslight
orfollowingmessage
appeared.
MENU P O C
2 sec.
Release thebutton. Position Cisset up.
MENU P O C
Auto calibration couldbe
required-error17
3.9.2. Limitposition“O”setup
Setup a new position manually
orby localcontrol. Recorda new valueby
pressingand holding
Obutton.
Holdthebuttonuntillsthe
MENUand PAR LEDslight
orfollowingmessage
appeared.
Release thebutton. Position Oisset up.
Calibration couldberequired-error17
MENU P O C

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
10
3.10. Regulator calibration
§Duringcalibration regulatorarriveto nearturningactuatorat two directions.
§Beneededprovideconditionsforfreeturningactuator.
Pressand holdPbutton. Holdthebuttonuntil
the LED ERR, LED MENU,
LEDPAR ordecimal
pointslight.
Release thebutton.
MENU P O C
Wait!
Theactuatorismovingwhen
theregulation isturnedon.
Thesuccessful
calibration isconfirmed
by followingmessage.
Signalization 3sec.
Position and errorsdisplay.
Faulty calibration is
Indicatedby following
message.Signalization
3sec.
7 5
6
12
11
10
8 4
2
1
9 3
CE(calibration error)
34=errornumber
ERR PARSEL
?
MENU
E17 =calibration error
!!! Notice: Explanation foreachmistakeismentionedincaption Registererrors.

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
11
3.11. MENU
3.11.1. MENU1– Torque
3.11.1.1. MENU1– Torque C
Display showsMENU1. Select Torque“C” by
pressingCbutton. Min.Valueofthetorque
“C” isdisplayed.
MENU P O C
5=50%
6=60%
7=70%
8=80%
9=90%
10=100%
(Selection 50 and 60 %
depend onmin.Torque
parameter.)
ChangetheTorquevalue
by pressingPbutton. New valueisdisplayed. Recorda new valueby
pressingand holdingP
button.
Recordisconfirmedby
PAR LED(red)ordecimal
pointslighting.
Release thebutton. Recordedvalueis
displayed.
MENU P O C

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
12
3.11.1.2. MENU1– Torque O
Display showsMENU1. Select Torque“O” by
pressingObutton. Min.valueoftheTorque“O” is
displayed.
5=50%
6=60%
7=70%
8=80%
9=90%
10=100%
(Selection 50 and 60 %dependon
min.Torqueparameter.)
ChangetheTorquevalue
by pressingPbutton. New valueisdisplayed. Recorda new valueby
pressingand holdingP
button.
Recordisconfirmedby
PAR LED(red)ordecimal
pointslighting.
Release thebutton. Recordedvalueis
displayed.
MENU P O C

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
13
3.11.2. MENU2– Endposition
Display showsMENU2. ChangeShut-offvalueby
pressingPbutton. New valueisdisplayed.
1= TorqueO + TorqueC
2= TorqueC + Position O
3= Position C + TorqueO
4= Position O + PositionC
MENU PAR
2 2
Recorda new valueby
pressingand holdingP
button.
Recordisconfirmedby
PAR LED(red)ordecimal
pointslighting.
Release thebutton.
MENU PAR
2
MENU P O C
Recordedvalueis
displayed.

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
14
3.11.3. MENU3– Torque blockage
3.11.3.1. MENU3– Time setup fortorque blockage
Display showsMENU3. Changetimeofblockage
by pressingPbutton. New valueisdisplayed.
Time0...20s
3=time 3s; max =20s
0=blockingshut off
MENU PAR
3 3
Recorda new valueby
pressingand holding
Pbutton.
Recordisconfirmedby
PAR LED(red)or
decimalpointslighting.
Release thebutton.
MENU PAR
3
MENU P O C
Recordedvalueis
displayed.

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
15
3.11.3.2. MENU3– Setup positionfortorque Oblockage
Display showsMENU3. Setup a new position manually
orby localcontrol. Recorda new valueby
pressingand holdingO
button.
Recordisconfirmedby
PAR LED(red)or
decimalpointslighting.
Release thebutton. Recordedvalueis
displayed.
MENU PAR
3
MENU P O C
3.11.3.3. MENU3– Setup positionfortorque Cblockage
Display showsMENU3. Setup a new position manually
orby localcontrol. Recorda new position by
pressingand holdingC
button.
MENU P O C
2 sec.
Recordisconfirmedby
PAR LED(red)or
decimalpointslighting.
Release thebutton. Recordedvalueis
displayed.
MENU PAR
3
MENU P O C

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
16
3.11.4. MENU4– Relay READY
Display showsMENU4. ChangeRelay READY
function by pressing
Pbutton.
New valueisdisplayed.
1= Errors
2= Errorsor warning
3= Errorsornotremote
4= Errorsor warning
or not remote
MENU PAR
4 2
Recorda new valueby
pressingand holdingP
button.
Recordisconfirmedby
PAR LEDordecimalpoints
lighting.
Release thebutton.
MENU PAR
2
MENU P O C
Recordedvalueisdisplayed.
MENU PAR
4 2

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
17
3.11.5. MENU5– Relay 1.. 5
3.11.5.1. MENU5– Relay 1..5
Display showsMENU5. Select Relay 1by pressing
Cbutton.
MENU P O C
Adecimalpoint indicates
relay beingset.Counted
fromleft.Whenno
decimalpointslight, than
relay 5will beset.
Relay 1example.
ChangeRelay 1..5 function
by pressingPbutton.
Relay 1
Relay 2
Relay 5
1= OFF
2= Position O
3= Position C
4= TorqueO
5= TorqueC
6= TorqueOor TorqueC
7= TorqueOor PositionO
8= TorqueCor Position C
9= Open
10= Close
11= Move
12= Move-blink
13= Toposition
14= Fromposition
15= Warning
16= Control –remote
17= Control –local
18= Control –off
New valueisdisplayed.
(examplerelay 1) Recorda new valueby
pressingand holdingP
button.
Recordisconfirmedby PAR
LEDordecimalpoints
lighting.

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
18
3.11.5.2. MENU5– PositionRelay 1..5
Relay 1.. 5position couldbeset only whentheappropriaterelay function isequalto Toposition (13) or From
position (14).
Setup a new position manually
orby localcontrol. Recorda new position by
pressingand holding
CorObutton.
Recordisconfirmedby
PAR LED(red)or
decimalpointslighting.
(ExampleRelay 1)
MENU P O C
2 sec.
Release thebutton. Recordedvalueis
displayed.
(Examplerelay 1)
MENU P O C

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
19
3.11.6. MENU6– CPT
Display showsMENU6. ChangeCPTsettingsby
pressingPbutton. New valueisdisplayed.
1=4-20mA
2=20-4mA
MENU P O C
2 sec.
Recorda new valueby
pressingand holdingP
button.
Recordisconfirmedby
PAR LED(red)ordecimal
pointslighting.
Release thebutton.
MENU P O C
Recordedvalueis
displayed.

DMS3 RJ_a_17.06.2013 version 1.3 74 1053 02
20
3.11.7. MENU7-Regulation,Analog controlsignal
3.11.7.1. MENU7– Regulation
Display shows
MENU7. By pressingCbutton
choose settingsof
regulation.
Valueisdisplayed.
MENU P O C
Changetypeof
regulation by pressingP
button.
New valueisdisplayed. Recorda new valueby
pressingand holdingP
button.
1=2P
2=3P
3=3P/2PI2
Recordisconfirmedby
PAR LEDordecimalpoints
lighting.
Release thebutton. Recordedvalueis
displayed.
Other manuals for DMS3
2
Table of contents
Other Regada Control Unit manuals
Popular Control Unit manuals by other brands

Bender
Bender LINETRAXX MRCDB423 manual

V2
V2 KIT EASY LUX instruction manual

ProSoft Technology
ProSoft Technology ILX34-MBS485 user manual

INOXPA
INOXPA 74700 Installation, service and maintenance instructions

Mankenberg
Mankenberg M-XTRA RP 824 Original operating manual

S.& A.S.
S.& A.S. MicroZed V3.5 user manual