Gi33LE Gas Insert | 7
Gas Connection
Vertical Venting
THE APPLIANCE MUST NOT BE CONNECTED TO A
CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to attach to 3" (76 mm) and 4" (102 mm)
co-linear aluminum ex running the full length of the chimney. The ue
length must be a minimum of 10' (3.05 m) and a maximum of 35' (10.7 m)
long. See the chart below for minimum distances from the roof. Periodically
check that the vent is unrestricted.
Masonry chimneys may take various contours which the exible liner will
accommodate. However, keep the exible liner as straight as possible
(avoid unnecessary bending).
Attach both the exhaust and intake ue liners to both the termination cap
& ue collar at the appliance with a minimum of three self-tapping screws.
Use Mil-Pac sealant to seal the pipes.
The air intake pipe must be attached to the inlet air collar of the termination
cap.
1. If the appliance is installed into an existing chimney system, thoroughly
clean the masonry or factory-built replace.
2. The appliance has an opening on the left side of the control compartment.
A 3/8” NPT gas supply pipe must be brought near the opening.
3. Locate the centre point where the vent will pass through the chimney,
above the appliance. Move the appliance to the installation location.
Ensure that the insert is level.
4. Do not cut any sheet metal parts of the replace into which the gas
insert will be installed.
5. If the factory-built replace has no gas access hole(s), drill one of 1-1/2"
(37-1/2 mm) or less through the lower sides or bottom of the rebox.
The access hole must be plugged with non-combustible insulation after
the gas supply line is installed.
C
L
Gas
Inlet
Electrical Connections
Part # Description
948-305 3" Flex - 35 ft.
948-336 4" Flex - 35 ft. (exhaust)
946-588 Co-linear DV Vertical Termination Cap
This appliance was tested and certied as a complete
system with the noted termination caps and ex liner.
Only the listed termination caps/ex liner noted below
can be used. Use of termination caps or ex liners not
listed in this manual will void the warranty and cer-
tication of this appliance. It is also important not to
enclose the termination cap inside a masonry chimney
rain cap, or similar. The termination must be exposed
on all four sides and above to exhaust and draw air
into the rebox.
IMPORTANT
Only people licensed to work with gas piping may
make the gas connections to this appliance.
WARNING
NOTE: Flashing should be securely
fastened to the chimney.
For Alternate Approved Vertical Termination Caps, see next page.