3
1. Changing P1 setting: flow temperature of water in central heating system
LT.NL.W6H.000.070
Reduce the flow temperature as follows:
• Press ‘Enter’- key until codes p[and [1are displayed alternately.
• Press ‘Enter’- key again; set value for maximum flow temperature is displayed:
75°C (factory setting).
• Press [+] or [-] -key to change this value, for example to 70°C.
• Press ‘Enter’- key to confirm value; codes p[and [1are displayed
alternately.
• Press ‘Reset’- key to switch boiler to operating mode.
2. Changing P2 setting: domestic hot water temperature
LT.NL.W6H.000.071
Increase the domestic hot water temperature as follows:
• Press ‘Enter’- key until codes p[and [1are displayed alternately.
• Press ‘[+]- key until codes p[and [2are displayed alternately.
• Press ‘Enter’- key; set value for domestic hot water temperature is displayed:
55°C (= factory setting).
• Press [+] or [-]- key to change this value, for example to 65°C.
• Press ‘Enter’- key to confirm value; codes p[and [2are displayed
alternately.
• Press ‘Reset’- key to switch boiler to operating mode.
3. Changing P3 setting: boiler regulation
(domestic hot water and central heating mode)
0= CH off / DHW off
1= CH on / DHW on (factory setting)
2= CH on / DHW off
3= CH off / DHW on
Change the boiler regulation as follows:
4. Changing P4 setting: Eco or comfort mode
No hot water
Beware; the system boiler in combination with an external calorifier will not warm
up the calorifier in the Eco-mode.
So, if the calorifier is empty, the tap water will be cold.
0= Comfort mode
1 = Eco mode
2= regulated by controller (= factory setting)
Change the mode as follows:
LT.NL.W6H.000.073
P6 setting: display on/off
Change the display setting as follows:
LT.NL.W6H.000.075
The boiler must be disabled before any maintenance or repairs are carried out. If the
central heating system is not used for a long time (during the holidays, for instance,
or periods of milder weather) it is advisable to disable the boiler.
1. Disable boiler with frost protection, during longer periods of non-use
LT.AL.W7H.000.217 + LT.AL.W7H.000.218
• Set the room thermostat to a low temperature, e.g. 10°C,
• Switch setting p4 to 1 (Eco mode), this will switch off the heat retention function.
Now the boiler will only start working to protect itself against freezing.
With an external frost protection connected, the boiler can also prevent the central
heating system from freezing.
LT.NL.W6H.000.072
• Press ‘Enter’- key until codes p[and [1are displayed alternately.
• Press [+]- key 3x until codes p[and [4are displayed alternately.
• Press ‘Enter’- key; setting of ‘eco or heat retention’ mode is displayed
(mode 2= heat retention and regulator-dependent, factory setting).
• Press [-]- key to change this mode, for example mode 1(=eco mode).
• Press ‘Enter’- key to confirm this mode; codes p[and [4are displayed
alternately.
• Press ‘Reset’- key to switch boiler to operating mode.
• Press ‘Enter’- key until codes p[and [1are displayed alternately.
• Press [+]- key 5x until codes p[and [6are displayed alternately.
• Press ‘Enter’- key; you will see mode 2( = ‘Display automatically off’, factory
setting).
• Press [-]- key to change this mode to mode 1(= ‘Display remains on’).
• Press ‘Enter’- key to confirm this mode; codes p[and [6are displayed
alternately.
• Press ‘Reset’- key to switch boiler to operating mode.
• Press ‘Enter’- key until codes p[and [1are displayed alternately.
• Press [+]- key 2x until codes p[and [3are displayed alternately.
• Press ‘Enter’-key: central heating and domestic hot water mode setting is
displayed.
• Press [-] or [+]- key to change this mode, e.g. level 3(= central heating OFF
and domestic hot water ON).
• Press ‘Enter’- key to confirm this mode; codes p[and [3are displayed
alternately.
• Press ‘Reset’- key to switch boiler to operating mode.
Broag Remeha is a licensed member of the Benchmark Scheme which aims to improve the
standards of installation and commissioning of domestic heating and hot water systems in the
UK and to encourage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council.
For more information visit www.centralheating.co.uk
Pre and After Sales Service
Our dedicated pre-and-after-sales teams are
ready te give you the support you need.
It’s an integral part of the quality package that
Broag offers as standard with all
products.
For all your queries just call the Avanta team
on: 0118 978 3434
Contact Information
Sales: 0118 9743060
After Sales: 0118 9743070
Literature: 0118 9743043
Training: 0118 9743020
Technical: 0118 9743070
Spares: 0118 9743070
www.avantarange.com