8. Position the Integra on a at counter
surface near the sink. With the spout
pointing into the sink, turn on COLD
water and divert the water through the
lter by turning the diverter valve handle
clockwise 90° (Figure 7).
9. Check for any leaks. To stop the
ow through the lter, turn off the faucet
or turn the diverter valve handle in the
opposite direction.
10. Resume owing cold water through
the lter for approximately ve minutes
to expel excess air and any loose
particles. For best results, always
allow water to ow through lter for
5-7 seconds before using water. After
sitting overnight or after several hours
of non-usage, run water through the
lter for 15 seconds before using.
MAINTENANCE
Clean the exterior of your lter using a
damp cloth and mild, non-abrasive dish
washing soap. Rinse off with warm
water and towel dry.
Cleaning the Double Action Cartridge
1. To prolong the life of your lter, clean
the cartridge whenever the water-
ow falls below an acceptable rate.
Note: Take sanitary precautions when
handling the soiled components of your
lter. We suggest using thin, waterproof
gloves.
2. Over the sink, unscrew the cartridge
from the base housing by holding the
base and turning the black plastic
screw knob in a counter-clockwise
direction. Pull out the cartridge. Drain
water out of the base housing and set
aside.
3. Dampen and then scrub the cartridge
with a nylon or plastic scouring pad
until the cartridge returns to its original
white color (Figure 8). Rinse thoroughly
in cold water. Discard or save the
scouring pad for the next cleaning of
the cartridge. Due to contamination do
not re-use for anything else.
Note: Never use soap or detergents
when cleaning the cartridge!
4. Reassemble the lter.
TROUBLESHOOTING
1. Water is not coming out of the
spout...
• Check to see that the diverter valve
is in the open position (Figure 7).
• Be sure the tubing is smooth and
straight without any kinks.
• Inspect the cartridge to see if
it has become dirty preventing
water from owing properly. If this
is the case, clean the cartridge.
(See “Cleaning the Double Action
Cartridge” in the Maintenance
section of this manual).
2. Water leaks from the base
housing...
• Hand-tighten the cartridge until
water stops leaking.
3. Water leaks from the tubing...
• Check the tubing for cuts or nicks.
If a portion of the tubing is leaking,
it must be replaced.
Figure 7
Figure 9
Figure 8
Lubricating the Diverter Valve
Over time, a diverter valve may lose its
lubrication and become more difcult
to operate. To improve the operation,
place a small drop of silicone lubricating
gel or petroleum jelly, e.g. Vaseline® at
the points shown (Figure 9). Turn the
valve handle back and forth several
times to spread the lubricant to all
moving parts.
Only use genuine Rena Ware
replacement parts. Contact
your Rena Ware Representative,
or the Rena Ware Customer
Service Center near you, to order
replacement parts for your Integra
water lter.
Visit our website at
www.renaware.com to locate
the Rena Ware Customer Service
Center nearest you.
Replacing the Double
Action Cartridge
After 10,000 – 15,000 liters or between
31 and 47 months of usage (depending
on the water quality in your area) or
if you notice tastes and odors in the
ltered water, you will need to replace
the cartridge assembly.
1. Remove the spout from the top of
the water lter and set aside.
2. Over the sink, unscrew the cartridge
from the base housing as indicated
in step 2 under “Maintenance”.
Discard the entire cartridge.
3. Install a new cartridge following
step 3 under “Setup”.
4. Insert the saved spout into the hole
on top of the black plastic screw
knob (see Figure 3 under Setup).
5. Continue with steps 8, 9, and 10
under Setup.