DE Die Abluft muss mit dem optionalen Abluftschlauch (A) direkt aus einem Unterschranksystem
heraus geführt werden, wenn bestehende Abluftöffnungen nicht den folgenden Abbildungen (B, C)
entsprechen.
EN The exhaust air must be allowed to escape directly from the cupboard by means of the optional-
ly available exhaust air duct (A) if the existing opening vents do not correspond to the following
pictures (B, C).
FR L‘air rejeté doit être évacué directement de l‘armoire par moyen de la conduite d‘évacuation d‘air
(A) disponible en option, si les ouvertures existantes ne correspondent pas aux images (B, C)
suivantes.
IT L‘aria di scarico deve essre convogliata all‘esterno direttamente dall‘armadio tramite lo scarico
aria (A) disponibile opzionalmente, se le aperture esistenti non corrispondono alle immagini (B, C)
seguenti.
ES El aire de escape debe extraerse con la manguera opcional para el aire (A) de escape directa-
mente de un sistema de armario en caso de que las aperturas existentes para el aire de escape no
se correspondan con las imágenes siguientes (B, C).
PT O ar da exaustão deve ser direcionado diretamente para fora do gabinete através do duto ex-
austor opcional (A) disponível, caso as aberturas existente não correspondam com as seguintes
imagens (B, C).
TR
RU
PL -
ZH 如果现有的通风口跟下图(B, C)不对应,那废气就必须借柜子里可选用的排气管(A)直接排出。
JA もし、既存の排気開口部が以下の図と違う場合 (B, C)、オプションの排気ホース(A)を使用して、キャビ
ネットシステムから直接排気をする必要があります。
KO 현재 열린 환기구가 (B, C)다음 그림과 같이 되어 있지 않을 경우 배기 공기를 배기 덕트를 이용해 벽장에서
바로 배출할(A) 수 있도록 해야 합니다.
AR

A

B
max. 25 mm
max. 1 inch
min. 100 mm
min. 4 inch
Wand / wall / mural / parete / pared / стене
min. 250 x 120 mm
min. 10 x 5 inch

C
Wand / wall / mural / parete / pared / стене
min. 50 mm
min. 2 inch

EN
TRANSLATION OF THE ORIGINAL INSTRUCTIONS FOR USE
Made in Germany
silent eC2
21-6813 30032017

EN
Contents
1 Introduction�����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������3
1�1 Symbols �����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������3
2 Safety�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������3
2�1 Intended Use������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������3
2�2 Improper Use�����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������3
2�3 Ambient Conditions for Safe Operation�����������������������������������������������������������������������������������������������������������������������������������������������������������������������������4
2�4 Ambient Conditions for Storage and Transport���������������������������������������������������������������������������������������������������������������������������������������������������������4
2�5 Hazard and Warning Information���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������4
2�5�1 General Information ���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������4
2.5.2 SpecicInformation����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������5
2�6 Authorized Persons�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������5
2�7 Disclaimer�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������5
3 Product Description������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������6
3�1 General Description������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������6
3�2 Component Groups and Functional Elements ������������������������������������������������������������������������������������������������������������������������������������������������������6
3�3 Delivery��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������7
3�4 Accessories���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������7
4 Initial Operation��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������8
4�1 Unpacking�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������8
4�2 Setting-up��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������8
4�3 Electrical Connection �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������8
4�4 Compressed Air Connection���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������8
4�5 Connection to a Suction Point �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������8
4�6 Connecting the Electrical Devices ���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������9
4�7 External Exhaust Air Duct���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������9
5 Operation������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������9
5�1 Switching On ���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������9
5�1�1 Standby����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������9
5�2 Operation����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 10
5�2�1 Suction Power �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 10
5�3 Filter Cleaning ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 10
5�3�1 Automatic Filter Cleaning�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������11
5�3�2 Manual Filter Cleaning�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������11
5�4 Setting the Parameter ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������11
5�4�1 Acoustic Signal����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������11
5�4�2 Time Interval for “Full” Display Dust Drawer���������������������������������������������������������������������������������������������������������������������������������������������������������������������� 12
5�4�3 Swtich-on Theshold for Automatic Operation�������������������������������������������������������������������������������������������������������������������������������������������������������������������� 12
5�4�4 After-run Time of the Suction Turbine ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 12
6 Cleaning / Maintenance����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 13
6�1 Cleaning�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 13
6�2 Empty Dust Drawer ������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������ 13
6�3 Change Fine Filter ���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 14
6�4 Self-diagnosis������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������ 14
6�5 Clean Compressed Air Filter ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 14
6�6 Fuses��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 15
6�7 Spare Parts �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 15
6�8 Factory Settings������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������ 15
7 Troubleshooting��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 15
8 Technical Data ������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������ 17
9 Warranty����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 18
10 Disposal Information���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 18
10�1 Disposing of Consumables�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 18
10�2 Disposing of the Unit������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������ 18
10�2�1Disposal Instructions for countries in the EU��������������������������������������������������������������������������������������������������������������������������������������������������������������������� 18

EN
1 Introduction
1.1 Symbols
Intheinstructionsforuseandontheunititselfyouwillndthesesymbolswiththe
following meanings:
Danger
This indicates a direct risk of injury. Consult accompanying documents!
Electrical current
This indicates a risk of hazard due to an electrical current.
Attention
Disregarding this warning may result in damage to equipment.
Note
This provides the operator with useful information to improve and ease use.
The device complies with the requirements of the applicable EU directives.
The device is subject to the EU directive 2002/96/EG (WEEE directive).
►List, particular attention should be paid
• List
- List
⇒Instructions / appropriate action / input / operational sequence:
Youwillbeaskedtocarryouttheactioninaspeciedorder.
♦Result of an action / reaction of the device / reaction of the program:
Theunitorprogramreactsasaresultofyouractionsorwhenaspecicincidentoccurs.
Other symbols are explained as they occur�
2 Safety
2.1 Intended Use
This device is designed to extract dry, non-explosive dust�
The unit is intended solely for use in a commercial dental laboratory and dental practice�
Theintendedusealsoincludescompliancewiththeinstructionsspeciedbythemanufacturerconcerning
operation, servicing and maintenance�
2.2 Improper Use
Fire-promoting,easilyammable,red-hot,burningorexplosivematerialsmustnotbesuctionedintothe
device�
It is not permitted to suction liquids�
This device is not intended for private, household use�
Anyuseotherthanspeciedintheseinstructionsisdeemedimproperandconstitutesamisuseofthe
device�
The manufacturer shall not be liable for damages caused by improper use�
Only spare parts and accessories supplied or authorized by Renfert GmbH may be used with this prod-
uct� If other spare parts or accessories are used, this could have a detrimental effect on the safety of the
device, increase the risk of serious injury and lead to damage to the environment or the device itself�
- 3 -

EN
2.3 Ambient Conditions for Safe Operation
The device may only be operated:
• Indoors
• Up to an altitude of 2,000 m above sea level,
• At an ambient temperature of between 5 - 40 ºC [41 - 104 ºF] *),
• At a maximum relative humidity of 80 % at 31 ºC [87�8 ºF], dropping to a linear of up to 50 % relative
humidity at 40 ºC [104 ºF] *),
• Withmainspowerwherethevoltageuctuationsdonotexceed10%ofthenominalvalue,
• Under contamination level 2 conditions,
• Under over-voltage category II conditions�
*) Between 5 - 30 ºC [41 - 86 ºF] the device can be operated at a relative humidity of up to 80 %� At temperatures
between 31 - 40 ºC [87�8 - 104 ºF] the humidity must decrease proportionally in order to ensure operational readi-
ness (e�g� at 35 ºC [95 ºF] = 65 % humidity, at 40 ºC [104 ºF] = 50 % humidity)� The device may not be operated at
temperatures above 40 ºC [104 ºF]�
2.4 Ambient Conditions for Storage and Transport
Forstorageandtransportthefollowingspecicationstoambientconditionsapply:
• Ambient temperature - 20 – + 60 ºC [- 4 – + 140 ºF]�
• Maximum relative humidity 80 %�
2.5 Hazard and Warning Information
2.5.1 General Information
►If the device is not used in compliance with the supplied instructions, the safety of the device can
no longer be guaranteed.
► The device may only be operated using a mains cable with the country-specic plug system. Any
necessary alterations must be carried out by a qualied electrician.
► The device may only be operated if the information on the identication plate conforms to the
specications of your local mains power supply.
After removing the Dust Drawer, you can nd the identication plate below, inside the device on
the left side.
►The device may only be plugged into outlets which are connected to the protective conductor
system.
►The mains plug must be easily accessible.
►Disconnect the device from the mains before carrying out work on the electrical parts.
►Check connection cables (such as power supply cords), tubes and housing (i.e. the key-pad)
regularly for damage (i.e. kinks, cracks and porosity) or signs of ageing. Devices with damaged
connection cables, tubes or housing parts or other defects must not be operated!
►Defective devices must be put out of service immediately. Remove the mains plug and ensure the
device is not used. Send the device for repair!
►Only operate the device under supervision.
►Please observe the national accident prevention regulations!
►It is the responsibility of the operator that national regulations during operation and regarding a
repeated safety inspection of electrical equipment are complied with. For Germany these are the
regulation 3 by DGUV (German Statutory Accident Insurance) in relation with VDE (Association for
Electrical & Electronic Technology) 0701-0702.
- 4 -

EN
2.5.2 Specic Information
► The mains socket on the device is only designed for purposes specied in the operating instruc-
tions. Connecting other devices may cause material damage.
►Please observe the national regulations and permitted exposure to dust in a working environment.
Please ask the “National Institute for Occupational Safety and Health” or other responsible au-
thority.
►Always refer to the relevant safety data sheets, when extracting hazardous materials.
►Always wear protective gear, when extracting hazardous materials.
►It is necessary to wear suitable personal protective equipment when emptying the dust drawer or
cleaning, depending on the type of extracted material.
► When disposing of the extracted material or used lter, please observe the local specications
and accident prevention regulations!
►Make sure the dust drawer is fully closed during operation.
►Do not operate without a suction hose.
► Do not extract ammable or explosive gasses, fumes or dust.
►Do not extract hot materials.
►Do not extract liquids.
►If the dust extractor is employed to extract hazardous materials, appropriate personal protective
gear must be worn and steps must be taken to ensure that the exhaust air is properly ventilated.
Please refer to the associated safety data sheets for specic requirements.
►Dispose of extracted material according to local statutory regulations.
2.6 Authorized Persons
Operationandmaintenanceofthedevicemayonlybeperformedbyqualiedpersonnel.
Minors and pregnant women may only operate and service the device if they are wearing appropriate
protective gear, in particular if the device is being used to extract hazardous materials�
Anyrepairsnotspecicallydescribedintheseoperatinginstructionsmayonlybecarriedoutbyaquali-
edelectrician.
2.7 Disclaimer
Renfert GmbH shall be absolved from all claims for damages or warranty if:
► The product is employed for any purposes other than those specied in the operating instruc-
tions.
►The product is altered in any way other than those alterations described in the operating instruc-
tions.
►The product is not repaired by an authorized facility or if non-original Renfert parts are implemented.
►The product continues to be used despite obvious safety faults or damage.
►The product is subjected to mechanical impacts or is dropped.
►The product continues to be used despite obvious safety faults or damage.
►The product is subjected to mechanical impacts or is dropped.
- 5 -

EN
3 Product Description
3.1 General Description
This is a workplace and appliance suction unit for extracting dust in dental laboratories�
The extraction unit comprises two suction channels, one suction point can be connect-ed to each chan-
nel�
The extraction unit can be operated both manually and automatically, depending on the connected, elec-
trical, dust-generating equipment�
3.2 Component Groups and Functional Elements
Fig. 1
2
3 13
6B
11
9
13
4A
4
1
5
8A
7
14
10
6A
8B
12
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
3029
20 21 22 23 24 25 26 27
333231
3
Fig. 2
2834
1 SILENT EC2
2 Control panel
3 On / Off switch
4 Dust drawer
4A Clamp fastener
5 Finelters
6A Suction port channel A
6B Suction port channel B
7 Velcro® strip
8A Device socket A
8B Device socket B
9 Mains cable
10 Protective device switch (2 x)
11 Exhaustairlter/Exhaustairoutlet
12 Suction hose and End bushings
13 Compressed air connection tube
(incl.compressedairlter)
14 Connection set
- 6 -

EN
3 On / off switch
20 Menu key
21 Symbol self-diagnosis
22 Symbol acoustic signal
23 Symbol dust drawer full
24 Set the switch-on threshold
25 Set the after-run time
26 7-segment display
3 Product Description
3.1 General Description
This is a workplace and appliance suction unit for extracting dust in dental laboratories�
The extraction unit comprises two suction channels, one suction point can be connect-ed to each chan-
nel�
The extraction unit can be operated both manually and automatically, depending on the connected, elec-
trical, dust-generating equipment�
3.2 Component Groups and Functional Elements
Fig. 1
2
3 13
6B
11
9
13
4A
4
1
5
8A
7
14
10
6A
8B
12
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
3029
20 21 22 23 24 25 26 27
333231
3
Fig. 2
2834
27 Display of the suction levels
28 Suction channel indicator
29 Suction channel keys
30 Enter key, save input / display enter key
31 [-] key / display function of the [-] key
32 Display Factory setting
33 [+] key / display function of the [+] key
34 Cover (do not remove, service interface)
3.3 Delivery
1 SILENT EC2
1 Quick Start Guide
1 Compressedairhose(xed)
1 Connection set
2 Pinch valve with suction supports (already installed)
1 Suction hose, 4 m
4 End bushings
3.4 Accessories
2934 0014 Disposal bag (25 pcs�)
2934 0015 Disposal bag, starter-kit
2921 0003 Set of end bushings, 2 pieces
90003 4240 Suction hose, 3 m, incl� 2 end bushings
90003 4826 Suction hose antistatic, 3 m, incl� 2 end bushings
90115 0823 Suction hose, 6 m
90215 0823 Suction hose, 9 m
90003 4305 Suction hose adapter
90003 4430 Universal suction hose adapter
90003 4314 Y adapter
2925 0000 Extractor clamp (without glass screen)
2925 1000 Glass screen with holder (for the extractor clamp)
2926 0000 Suction switch, incl� 4 bushings (without hose)
2937 0002 External exhaust air
2934 0007 90° angled connector Silent
For more details or further accessories, please see www.renfert.com
- 7 -

EN
4 Initial Operation
4.1 Unpacking
⇒Remove the device and accessories from the package�
⇒Check the delivery for completeness (compare the list included in delivery)�
4.2 Setting-up
The suction unit is a standing device which must not be operated in a horizontal position�
Place the suction unit so that:
• the exhaust air outlet (11, Fig� 1) is not blocked�
• the front side is easily accessible for removing the dust drawer�
If the suction unit is placed in a closed cabinet, the warm exhaust air must be transported out of
the cabinet using one of the measures shown in Figs. A, B, C at the start of this manual.
• External exhaust air duct (A) (see chapter 4�7)�
• Opening in the cabinet wall (B), min� 250 x 120 mm, directly opposite the exhaust air outlet (11, Fig�1)�
- Distance of the cabinet back side to the wall: min� 100 mm�
- Distance of the suction unit to the cabinet back side: max� 25 mm�
• Remove the back side of the cabinet (C), distance from the back of the cabinet to the wall min� 50 mm�
If the warm exhaust air is transported out through the openings to the rear, it is essential that the air can
escape unhindered from there�
4.3 Electrical Connection
Before connecting to electricity, ensure that the voltage on the type plate conforms to the local
voltage supply.
Ensure that the layout of live parts (socket, plug and coupling) and extension cables are arranged
so that the protection class is maintained.
⇒Switch the device off at the on / off switch (3, Fig� 2)�
⇒Unroll the mains cable (9, Fig�1) and insert the plug into the building’s electrical socket�
4.4 Compressed Air Connection
The suction channels are opened and closed by means of pneumatic pinch valves� Compressed air is
required for this� The compressed air tube is securely connected to the side of the device�
For connection to the compressed air network:
⇒Select the appropriate tube coupling from the supplied connection set (14, Fig� 1) and attach it to the
end of the tube�
⇒Connect to the compressed air network
Observe the minimum / maximum connection pressure, see technical data!
The compressed air must be clean and dry (no condensation). Moist compressed air can cause
damage to the device!
4.5 Connection to a Suction Point
Warning risk of injury!
When shortening the suction tube, please be sure to cut the
integrated wire as straight as possible.
Long suction tubes, tight bends and kinks greatly reduce the
suction power at the suction point.
When there are different tube lengths, the suction capacity at
the suction points with longer tubes is lower.
Ensure that the suction tubes are the same length and diame-
ter. Excess length should be shortened or tubes must be laid
in large circles.
⇒Shorten the suction tubes to the required length for both suction
points�
⇒Screw the end bushings onto the suction tubes (left turn thread)�
6B
Fig. 3
6A
- 8 -

EN
⇒Place the suction tube onto the suction port (6A / 6B)�
Observe the allocation of the device sockets (A, B) – suction channel (A, B)�
⇒Connect the suction tube to the correct suction point�
If the diameter is not suitable, use an adapter (see accessories), to avoid loss of suction.
Avoid steep sloping and “sagging” of the tubes.
4.6 Connecting the Electrical Devices
⇒Connect the electrical equipment to the device sockets (8A / 8B)
on the back�
Observe the allocation of the device sockets (A, B) – suction
channel (A, B)�
When connecting the electrical equipment to the suction unit,
ensure that the sum of the electrical power from the connect-
ed electrical appliances does not exceed the maximum per-
missible total power (see chapter 8 “Tech. Data”).
4.7 External Exhaust Air Duct
The exhaust air can be transported out of the laboratory via an external exhaust air duct (see accesso-
ries)�
The installation instructions are included in the external exhaust air duct�
When using suction devices in conjunction with an external exhaust air duct, a large amount of
air is extracted from the room per hour.
This can lead to a negative pressure, whereby, when using air-dependent replaces with gas,
liquid or solid fuels, poisonous gases (e.g. carbon monoxide) will be sucked into the (working)
space.
Depending on the structural situation, it is therefore essential to ensure there is an addition-
al air supply or negative pressure monitoring which is checked by the appropriate institutions
(e.g. chimney sweep or heating engineer).
5 Operation
The suction is controlled by the keys on the control panel (Fig� 2)�
5.1 Switching On
The suction unit is switched on and off via the on / off switch (3)�
After activation:
♦ Thesuctionunitperformsanautomaticltercleaning(seechapter5.3).
Then the unit is in standby mode�
From the standby mode the unit can be changed to:
• operation, with one or both suction channels (see chapter 5�2);
• programming (see chapter 5�4);
• standby mode (see chapter 5�1�1)�
5.1.1 Standby
In the standby mode the display is dark�
⇒For the duration of 2 minutes, no key pressed and no suction channel opened�
♦Change to standby mode�
⇒Press any key�
or
⇒Switch on an electrical appliance connected to the suction point� In this case, the suction channel is
opened immediately and the suction turbine is switched on�
♦Standby mode is exited�
Fig. 4
8A 8B
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
3
Fig. 5
- 9 -

EN
5.2 Operation
After switching on, the suction unit is in standby mode�
If a suction channel is activated, the suction turbine switches on with the last set suction power level and
the associated pinch valve is opened�
If the second suction channel is then activated, the second pinch valve opens�
The opening / closing of the suction channels takes place:
• Automatically:
An electrical appliance connected to a device socket (8A / 8B, Fig� 1) is
switched on / off�
• Manually:
By pressing a suction channel key (29)�
The letters of the opened suction channels (28) are shown in the display�
If a connected device is switched on, the corresponding suction channel can NOT be closed manually
with the suction channel key, but only by switching off the electrical device�
If the suction to a connected electrical appliance does not react as required (e.g. does not acti-
vate, even though a connected device is in operation) then the switch-on threshold for automatic
operation has to be adjusted (see chapter 5.4.3).
5.2.1 Suction Power
The suction power for the suction unit can be set in 3 levels�
The current level is shown in the display (27)�
Change the suction power:
⇒Press the [-] key (31)
♦Reduce suction
⇒Press the [+] key (33)
♦Increase suction
The suction always starts with the last used suction level�
Adjustment of suction power:
The set suction level applies to all suction channels� Therefore, the power of the suction turbine is auto-
matically readjusted when a further suction channel is opened or closed, in order to reach the adjusted
suction power at the opened suction channels�
To disable the adjustment of the suction power:
In standby mode:
⇒Press the [+] / [-] keys (33 / 31) at the same time for a duration of 3 sec�
♦By pressing the [-] key (31), the display shows “OFF”�
The deactivated adjustment of the suction power is permanently indicated by the
“OFF” indicator above the [-] key (31)�
To activate the adjustment of suction power:
In standby mode:
⇒Press the [+] / [-] keys (33 / 31) at the same time for 3 sec�
♦ Thedisplaywilldelete“OFF”inthedisplayeldabovethe[-]key(31).
If the suction performance is deactivated, the suction power at a suction channel can drop notice-
ably when the second suction channel is activated.
When suction level “3” and both suction channels are opened, only a reduced suction capacity is
available at the suction channels, since the performance of the suction turbine cannot be further
increased.
5.3 Filter Cleaning
Inordertoensuremaximumsuctionperformance,thesuctionunithasadeviceforcleaningthenelter
unit� The cleaning takes approx� 8 sec�
The cleaning is carried out:
• Automatically:
- After the unit is switched on;
- Withinsufcientsuctionpower(owvelocityfallsbelowaninternallimitvalue);
- If the unit has been operated for more than 8 hours (turbine running time) without switching it off;
• Manually, e�g� before removing the dust drawer to empty it (see chapter 6�2)�
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
Fig. 6
29
28
27
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
31 Fig. 7
33
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
Fig. 8
31 33
- 10 -

EN
5.3.1 Automatic Filter Cleaning
♦Suction turbine is stopped�
♦The symbol “dust drawer” blinks�
♦“CLEAn” is shown in the display�
♦An acoustic signal indicates the cleaning is about to commence�
♦The cleaning is carried out�
♦Suction turbine starts again�
5.3.2 Manual Filter Cleaning
⇒Press the Enter key (30) and keep pressed for 2 sec�
♦ Theltercleaningisperformed.
5.4 Setting the Parameter
On delivery, there are parameters set, which in most cases, make it possible to work with the suction unit
without problems� Only in individual cases, if this is not possible, the parameters can be changed�
The setting of various parameters and the execution of a self-diagnosis are carried out in the program-
ming mode�
The display indicates which parameters are set:
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
Perform self-diagnosis (see chapter� 6�4)
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
/
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
Acoustic signal (buzzer) on / off
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
Time interval for full display (full) in the dust drawer
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
Set switch-on interval for automatic (calibration)
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
Set after-run (time) for the suction turbine
To set the different parameters, press the Menu key (20, Fig� 2)� The settings
areconrmedandsavedwiththeEnterkey(30,Fig.2).Successfulsavingis
acknowledged with an acoustic signal�
If a change is not accepted, pressing the Menu key (20) will abort the program-
ming�
If the word “Default” (32) appears in the display, you can reset the value to the
factory setting (see chapter 6�8) by pressing the [-] and [+] keys at the same time�
5.4.1 Acoustic Signal
Various settings and warnings are confirmed or indicated by an acoustic signal�
This beep can be switched on and off� The acoustic signal symbol (22) indicates
whether is on or off�
To change:
⇒Press the Menu key (20) 2x�
♦The symbol acoustic signal (22) blinks�
⇒Switch the acoustic signal on or off with the [+] / [-] keys�
⇒Press the Enter key (30)�
♦Save changes, exit programming mode�
Fig. 9
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
31 33
32
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
22 3020
Fig. 10
- 11 -

EN
5.4.2 Time Interval for “Full” Display Dust Drawer
After reaching a set time interval, a request appears to empty the dust drawer�
You can select between 5 times (factory setting 50 hrs)�
Time interval / hrs Value in display (24, Fig. 2)
2 1
5 2
10 3
50 4
100 5
To change:
⇒Press the Menu key (20) 3 x�
♦The symbol dust drawer full (23) blinks�
♦A number is shown in the display (see table)�
⇒Use the [+] / [-] keys to increase / decrease the value�
⇒Press the Enter key (30)�
♦Save changes, exit programming mode�
In devices which generate large amounts of dust (e.g. sandblasting units) the time interval for the
full display of the dust drawer should be set to 5 hours, if necessary, 10 hours.
5.4.3 Swtich-on Theshold for Automatic Operation
⇒On delivery, the switch-on thresholds are provided for the two suction channels, which enable trou-
ble-free operation with most handpieces�
⇒If the suction function does not react correctly to a connected handpiece, the switch-on threshold can
be set individually for each suction channel�
⇒Press the Menu key (20) 4 x�
♦The symbol - set switch-on threshold - (24) blinks�
♦The letters A and B blink�
⇒Press the suction key (29) of the suction channel which is to be set�
♦The letter of the selected suction channel is displayed�
♦The display shows “OFF”�
⇒Switch this off in an electrical device without standby mode
⇒In an electrical device with a standby mode (e�g� handpieces), switch to standby mode (e�g� with a
handpiece, switch only the control unit on without activating the handpiece)�
⇒Press the Enter key (30)�
♦The display shows “ON”�
⇒Switch this on in an electrical device without standby mode
⇒For handpieces, operate this at the speed at which the suction is to be started and run for approx�
3-5seconds(sothatoverowduringstart-upisnotdetected).
⇒Press the Enter key (30) (whilst the handpiece is still running)�
♦The setting is saved�
⇒Select the next suction channel to be set or exit with the Menu key (20)�
For devices with standby mode, these should be switched on approx. 5 minutes before setting to
avoid incorrect measurements.
If an error occurs during the setting of the switch-on threshold, the display will show “Cal” and an
acoustic signal will sound 2 x. Set the changes again.
5.4.4 After-run Time of the Suction Turbine
After-run time = The period of time between switching a connected device off and the closing of the corre-
sponding suction channel (= pinch valve)�
A distinction is made between three after-run times, which can be set independently of one another:
• After-run time suction channel A only suction channel A is open:
Time, until the pinch valve of suction channel A closes and the suction turbine switches off�
• After-run time suction channel B only suction channel B is open:
Time, until the pinch valve of suction channel B closes and the suction turbine switches off�
• After-run time suction channel A and B both suction channels, A AND B, are open:
Time, until the pinch valve of a suction channel closes and the suction performance for the other suction
channel is adjusted�
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
23 3020
Fig. 11
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
29 30
20 24
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
Fig. 12
- 12 -

EN
In order to prevent the suction from being switched on / off too often, or the suction performance
to be adjusted too frequently in the case of short interruptions (for example when working with
the handpiece), a higher time value should be selected.
To change:
⇒Press the Menu key (20) 5 x�
♦The symbol - after-run time - (25) blinks�
Setting after-run time suction channel A:
♦The letter A is shown�
♦In the display, the currently set after-run time for suction chan-
nel A is shown in seconds�
⇒Set the required after-run time via the [+] / [-] keys�
⇒Press the Enter key (30)�
Setting the after-run time suction channel B:
♦The letter B is shown�
♦In the display, the currently set after-run time for suction channel B is shown in seconds�
⇒Set the required after-run time via the [+] / [-] keys�
⇒Press the Enter key (30)
Setting the after-run time suction channel A and B:
♦The letters A and B are shown�
♦In the display, the currently set after-run time is shown in seconds�
⇒Set the required after-run time via the [+] / [-] keys�
⇒Press the Enter key (30)�
The setting after-run time can be exited at any time before or after saving the entered value via the Menu
key (20)�
6 Cleaning / Maintenance
The device does not contain any parts that require maintenance.
Opening the device other than described in the instructions is not permitted!
6.1 Cleaning
To clean the device wipe only with a damp cloth�
Do not use and solvent-based or abrasive cleaning agents�
6.2 Empty Dust Drawer
After reaching the set time interval (see chapter 5�4�2), the dust drawer is requested to be emptied:
♦An acoustic signal sounds 3 x�
♦The symbol “dust drawer full” is shown�
♦In the display “FULL” is shown�
Beforeremovingthedustdrawer,altercleaningfunctionshould
be performed:
⇒Press Enter key (30) for 2 seconds�
♦ Theltercleaningfunctionisperformed.
Aftertheltercleaninghasnished:
⇒Unlock the dust drawer with the clamp fastener (4A)�
⇒Pull the dust drawer (4) forward and empty�
⇒Replace the dust drawer again until it locks into place�
⇒Close the clamp fastener (4A)�
⇒Press the Enter key (30) (counter for recording the time interval
is reset)�
♦Acoustic signal acknowledges the information�
♦Dust drawer display (23) is deleted�
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
29 30
20 25
MENU
A
B
OFF
ON
AB
OFF ON
resetdefault
Fig. 13
4A
4
Fig. 14
- 13 -

EN
If the dust drawer is not emptied, the “Dust drawer full” and “FULL” symbols are still shown in the
display. After switching the device off and on again, a 3 x acoustic signal is used to indicate the
emptying of the dust drawer.
6.3 Change Fine Filter
Theeffectivenessoftheltercleaningisdeterminedbymonitoringtheowrate(internalpressuresen-
sor)�
Ifaltercleaningisrequiredseveraltimesinsuccessionafterlessthan2hours,thismeansthatthene
lterissohighlycloggedthattheltercleaningdoesnotshowsufcienteffectandthenelterhastobe
changed�
This is indicated as follows:
♦The display shows “FILt”
♦For a period of 15 min�, 2 long beeps are sounded for 3 min at a time�
The error message can be switched off by switching off the suction�
If requested to change the ne lter or the suction performance does not improve substantially or
only for a short period, the ne lter must be changed soon.
Further operation can lead to damage to the device.
Whenreplacingthenelter,payattentiontothecorrectt,otherwiseleakswilloccur.Pleaserefertothe
assemblyinstructionsattheendofthemanual,whicharealsoincludedwiththenewneler.
6.4 Self-diagnosis
With the help of the self-diagnosis, the control system checks the function of the turbine and pinch valves
as well as parts of the electronics�
Self-diagnosis can be started manually�
Ifnofaultisdetected,thesuctionisreadyforoperationaftertheself-diagnosishasnished.
If an error is detected, an indication is shown in the display�
Perform self-diagnosis:
⇒Press Menu key (20) 1 x�
♦The symbol - self-diagnosis - (21) blinks�
⇒Press Enter key (30)�
♦Self-diagnosis starts�
♦The self-diagnosis symbol is shown in the display and a dash flashes over the screen�
♦The suction turbine runs at different suction levels and the pinch valves open and close in various
combinations�
No error:
♦Suction is in standby mode�
Error occurred
♦The error is shown in the display�
⇒Solve error (see chapter 7)�
⇒Press Enter key (30)�
- 14 -

EN
6.5 Clean Compressed Air Filter
Thecompressedairlterisintegratedinthecompressedaircon-
nection tube�
Acloggedcompressedairlteraffectsthesafefunctionofthe
pinch valves, since these are no longer reliably closed� This can
lead to reduced suction performance at the suction channel in use
or acknowledged as leakage by the control�
To clean:
⇒Detach from compressed air connection�
⇒Roll the rubber ring (40) back�
⇒Unscrewthelterhousing(screwdriverSW13mm),usingthe
suppliedspecialscrewdriveronthelterhousing.
⇒Screw out the sleeve (41) with an Allen key�
⇒Removesieve(42)andlterliner(43).
⇒Replacewithanewlterlinerandsieve,payattentiontothe
correct sequence�
⇒Screw in the sleeve and tighten by hand�
⇒Screwthelterhousingclosed.
⇒Replace the rubber ring�
6.6 Fuses
The fuse is protected by two device protection switches (10, Fig� 1)�
A triggered device protection switch is reset by depressing the button�
Repeated triggering of a device protector will result in a defect in the device.
Send the device in for repair!
6.7 Spare Parts
Youcanndcomponentssubjecttowearandthesparepartsonthesparepartlist
in the internet at www.renfert.com/p918�
Enter the following item number: 29370000�
The components excluded from the warranty (such as consumables or parts subject
to wear and tear) are marked on the spare part list�
Serial number and date of manufacturing are shown on the type plate of the unit�
6.8 Factory Settings
⇒Switch device off (3, Fig� 1)�
⇒Press the [-] key (31) and [+] key (33) at the same time�
⇒Switch device on and press the keys for 3 seconds�
♦“rES” is shown in the display�
♦All values are reset to the factory settings�
♦ Anacousticsignalconrmsthereset
Factory settings:
Function / Characteristic Setting range Factory setting
Operating mode Automatic mode /
Permanent operation Automatic mode
Suction level 1 - 3 1
Time interval 2 - 100 hrs 50 hrs
After-run time 0 – 30 sec� 3 sec�
Switch-on threshold
(automatic mode) 1 - 100 W 8 W
Fig. 15
41
42
43
40
- 15 -
Table of contents
Popular Computer Hardware manuals by other brands

Thermaltake
Thermaltake Pacific TOUGH C240 DDC installation guide

Motorola
Motorola MC68030 user manual

FSP Technology
FSP Technology AURUM PT 1000W user manual

Link electronics
Link electronics Analog Pulse Generator 812-OP/H Specification sheet

SDR-Kits
SDR-Kits DG8SAQ VNWA 3 manual

Crestron
Crestron CNX-PAD8A Operation guide