ReptiZoo THC16 User manual

THC16
EZ THERMOSTAT TIMER CONTROLLER
INSTRUCTION MANUAL
Thanks for choosing REPTIZOO EZ thermostat timer controller. In order to use this EZ
thermostat timer controller properly and ensure its service life, please read the instructions
manual carefully before using it.

WARNING
1.
2.
3.
Check the power cable for damage, compression deformation
and other defects before use; in case any defect is identied,
do not use the power cable, but send it to the manufacturer or
replace it by its service agent or related professionals to avoid
danger.
The main engine and power adapter of this product shall be
protected from liquid and shall not be immersed in liquid.
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
-Children shall not play with the appliance.
-Cleaning and user maintenance shall not be made by children
without supervision.
PRODUCT OVERVIEW
THC16 EZ Thermostat Timer Controller is an intelligent product developed under the theoretical instructions
of numerous reptile experts around the world and based on the feeding experience of reptile professionals
over the years. It can realize day and night time-period temperature control and multi-time period timing
control (a maximum of four periods). It provides power control for heating, cooling, timing devices in reptile
pet and aquarium pet feeding, garden building, etc. It is an excellent intelligent management product in
reptile pet feeding industry.
Thank you for choosing the products of REPTIZOO. Please read this Manual carefully and follow the
instructions before operation.
PRODUCT FEATURES
1.
2.
3.
4.
5.
The integrated design adopting multiple control in temperature and timing can meet the needs of reptile
pets for temperature, lighting and other environmental conditions.
Thanks to the “One Click” setting function, it can quickly switch to Tropical Mode or Desert Mode.
With separate day and night temperature control design, it can adequately simulate the diurnal
temperature variations of reptile pets.
The temperature sensor connectors employ quick-plug design, which can realize fast storage and
replacement, and simple and practical product maintenance to a certain extent.
The cooling delay protection function can prevent the cold air compressor from being damaged due to
frequent start-up and signicantly prolong the service life of the cooling device.
PRODUCT LIST
1. Temperature and timing control box (control box): 1
2. Power output box: 1
3. Temperature sensor: 1
4. Velcro: 1 pair
5. Instruction Manual: 1
1

1Tropical mode key
2Desert mode key
3Day temperature control setting key
4Night temperature control setting key
5Time setting key
6Period 1 timer control setting key
7Period 2 timer control setting key
8Period 3 timer control setting key
9Period 4 timer control setting key
10 Increase
11 Decrease
12 Day temperature control indicator light
13 Night temperature control indicator light
14 Timing control indicator light
Day/night starting time
Current time
Period timing setting
Current temperature
Night temperature control
setting value
Day temperature control
setting value
DESCRIPTION OF THE OPERATION INTERFACE OF THE CONTROL BOX AND POWER OUTPUT
BOX
1. Description of the control box panel.
2. Description of controller panel and LCD
6.
7.
8.
The over-temperature alarm function can intuitively show the discomforts of pets arising from the
temperature being too high or too low thus to better protect your pet.
Relying on the power failure memory function, the parameters that have been set can be memorized
in case of power off or sudden power failure so that the control box doesn’t need to be reset in such a
circumstance.
The overload protection function of power output box can eliminate the unsafe hazards caused by
excessive load power or short circuit.
1
6
2
7
3
8
4
95
10
11
13
14
12
2

1Temperature sensor
2Memory battery slot
3Default reset button
4Backlight switch
1Temperature control socket
2Timer socket
3Power cord
4Fuse reset button
5A max. of 400W for each socket
1 2
3
4
5
Female bus Male bus Temperature sensor
3. Back of the control box.
4. Power output box interface.
5. Mounting of waterproof quick-plug bus of temperature sensor.
• "T SENSOR" indicates the temperature sensor. It can be mounted by aligning the male and female bus
to the slots and pressing hardly.
TECHNICAL PARAMETERS AND DESCRIPTION
1. Description of the major parameters:
• Control box size: 160x50x23 mm.
• Power output box size: 195x77x50 mm.
• Working voltage: 120V~ 60Hz.
• Temperature control range: 32-122°F.
• Temperature measurement range: -4~122°F .
• Temperature difference setting range: 2-28°F
• Over-temperature alarm value: ±6°F outside the setting range.
• Time is in 24-hour system.
TSENSOR
CR2032
Reset
1
2
3
4
Temperature Timer Alawys ON
3

2.Original parameters / TROPICAL parameters / DESERT parameters and description:
• Day and night temperature and temperature control modes are set and controlled separately.
•When the temperature exceed the measurement upper limit, the LCD will display HH and make an alarm
sound.
• When the temperature exceed the measurement lower limit, the LCD will display LL and make an alarm
sound.
•
LCD area, and the power output will be automatically cut off with an alarm sound.
• In the setting state, the device will automatically save the parameters and return to the working state if
no button is pressed within 30 seconds.
• The starting point for daytime must be lower than that for night.
• When the set timing time of two or more adjacent points is the same, the system only executes the setting
time of the next point.
• When setting the value, long press “▲” or “▼” button to increase or decrease the number quickly.
• With overload protection function.
• With power failure memory function.
• The sensor detection frequency is once per every 5 seconds.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Day on
Night on
Day temperature on
Day temperature off
Night temperature on
Night temperature off
T Timer 1 ON
T Timer 1 OFF
T Timer 2 ON
T Timer 2 OFF
T Timer 3 ON
T Timer 3 OFF
T Timer 4 ON
T Timer 4 OFF
Starting time of day
Starting time of night
Power-on day temperature
Power-off day temperature
Power-on night temperature
Power-off night temperature
Timer 1 turn-on time
Timer 1 turn-off time
Timer 2 turn-on time
Timer 2 turn-off time
Timer 3 turn-on time
Timer 3 turn-off time
Timer 4 turn-on time
Timer 4 turn-off time
8:00
18:00
86°F
91°F
73°F
77°F
08:00:00
18:00:00
23:59:59
23:59:59
23:59:59
23:59:59
23:59:59
23:59:59
8:00
18:00
82°F
86°F
75°F
79°F
08:00:00
18:00:00
23:59:59
23:59:59
23:59:59
23:59:59
23:59:59
23:59:59
8:00
18:00
86°F
91°F
73°F
77°F
08:00:00
18:00:00
23:59:59
23:59:59
23:59:59
23:59:59
23:59:59
23:59:59
No. Mode Function Description Default Value TROPICAL Original
Set Value
DESERT Original
Set Value
4

A. Heating lamp
B. UV lamp
3. Operation diagram:
4. Operation description:
• This product can turn on and off the devices on two-way power supplies by controlling two-way power
outputs. As shown in the diagram above, control the heating lamp and UV lamp respectively at two ways.
• Operation description of the device at way A (heating lamp):
First, set the current time based on which we can determine whether to enable the day temperature
controller or the night temperature controller, and then set the power-on temperature and power-off
temperature with the day temperature controller or the night temperature controller. If the current
temperature is ≤ the power-on temperature, start way A power output and the heating lamp will start
working. Conversely, if the temperature is ≥ the power-off temperature, stop way A power output and the
heating lamp will stop working.
• Operation description of the device at way B (UV lamp):
Set the time by timer. A maximum of 4 time periods can be set (four power-on time and four power-off
time). If the current time reaches the power-on time value, start way B power output and the UV lamp will
start working. Conversely, if the current time reaches the power-off output value, stop way B power
output and the UV lamp will stop working.
Alawys ON
5

09:30:08 08 18 82 86 75
08:00:00
79
18:00:00
83 f
09:30:08 08 18 89 91 73
08:00:00
77
18:00:00
90 f
09:30:08 08 18 89 91 73
08:00:00
77
18:00:00
90 f
00:00:00 08 18
00:00:00 08 18 00:00:00 08 18 00:00:00 08 18 00:00:00 08 18
OPERATION METHOD
Before using for the rst time, make sure the power is plugged in and get familiar with the setting
method according to the instructions below. (The diagram is for reference only)
1. Beginner (default setting)
• Tropical mode: Long press " Tropical " for 3 seconds to directly call the preset temperature values in the
Tropical mode.
(Please refer to Chapter IV: Technical parameters and description, clause 2 "Original parameters /
TROPICAL parameters / DESERT parameters and description")
2. Advanced user (user dening)
• Settings of current time, day and night starting time:
Press the " Time " button in sequence, and the corresponding hours, minutes corresponding to current
time, day starting time and night starting time will ash on the LCD in sequence. When the number is
ashing, you can adjust it by pressing "▲" or "▼", increasing or decreasing by 1 each time. Long press
to increase or decrease the value quickly.
• Desert mode: Long press “Desert” for 3 seconds to directly call the preset temperature values in the
Desert mode.
(Please refer to Chapter IV: Technical parameters and description, clause 2 "Original parameters /
TROPICAL parameters / DESERT parameters and description")
• After selecting the above two default modes, if you want to set the current time, please refer to the
corresponding setting method for the advanced user as follows.
6

09:30:08 08 18 82 86 75
08:00:00
79
18:00:00
83 f
82 ﹤ 86
Heating Mode
82 86 82 86
When the rst value is greater than the second value under the symbol " ", it means
cooling mode.
The cooling mode is started with 3 min. delay every time to prevent the compression pump of the cooling
device from being damaged due to frequent startup in a short time.
When the rst value is less than the second value under the symbols " " and
" ", it means heating mode.
• Day and night temperature setting:
Press the " " and " " in sequence. The corresponding day temperature and night temperature will
ash in sequence on the LCD. When the number is ashing, you can adjust it by pressing "▲" or "▼",
increasing or decreasing by 1 each time. Long press to increase or decrease the value quickly.
82 86 70 77
82 86 82 86 82 86 82 86
89 86 89 86
89 ﹥ 86
Cooling Mode
7

09:30:08 08 18 82 86 75
08:00:00
79
18:00:00
83 f
T3 T4 T5 T6 T7 T8
T1 T2
00:00:00 23:59:59
• Power-on and power-off time values for four time periods:
Power-on and power-off time values for time period 1:
Press the " " button in turn, and the hours, minutes, and seconds of the power-on and power-off time of
pressing "▲" or "▼", increasing or decreasing by 1 each time. Long press to increase or decrease the
value quickly.
Notes:
A total of 8 time points should be set for the power-on and power-off time of four time periods. If the power-
on time of time period 1 is set to T1, the power-off time of time period 1 will be T2; the power-on time of time
period 2 will be T3, the power-off time of time period 2 will be T4; the power-on time of time period 3 will
be T5, the power-off time of time period 3 will be T6; the power-on time of time period 4 will be T7, and the
power-off time of time period 4 will be T8.
Then, when we set the values, we must make sure that T1≤ T2≤ T3≤ T4≤ T5≤ T6≤ T7≤ T8.
The setting method of power-on and power-off time of time period 2, 3 and 4 is the same as above.
00:00:00 23:59:59
00:00:00 00:00:00 00:00:00 00:00:00 00:00:0000:00:00
00:00:00 23:59:59 00:00:00 23:59:59
• Description of over-temperature alarm function:
Over-temperature alarm:
For example, if the preset upper temperature limit is 95°F the over-temperature alarm will be
made at 100.6°F. You can press any key to turn off the alarm sound, and set other values after
turning off the audible alarm.
Ultralow temperature alarm:
For example, if the preset temperature is 86°F, the ultralow temperature alarm will be made at
80.4°F. You can press any key to turn off the alarm sound, and set other values after turning
off the audible alarm.
8

SAFETY AND MAINTENANCE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Check if there is any damage, deformation or other defects of the device and sensor cables. If yes, it
is suggested not to use, but report to the manufacturer or its service agent or relevant professional for
detection and maintenance to avoid danger.
Do not install or store the device in an environment exposed to the sun, rain or freezing temperatures
(indoor use only).
Conrm whether the voltage conditions meet the requirements before connecting the device.
Before operating the device, make sure that the temperature sensor of the controller have been properly
installed and the electrical devices on the power output box have been securely connected as required.
If the electrical devices on the power output box are turned on or off frequently, the service life of the
lamps, e.g. lamp bulb or spot light will be shortened when using the temperature controller.
To further protect your device, it is recommended to choose G.F.C.I (ground fault circuit interrupter) and
surge protectors.
Carefully inspect the device after the installation. If there is any water observed on the product, do not
power on (special attention should be paid when using aquatic products). It is recommended to use the
products in a dry environment.
Protect the device from moisture or splashed water during use.
If any extension cord is used, the extension cord should be of appropriate rating (current and weather
rating).
Place the wires with care to avoid being torn or pulled.
When toggling the power switch and plugging the power cord from the socket, make sure your hands are
dry. Do not pull the cable out of the socket forcibly.
When the product is not in use, unplug the product from the power socket.
To avoid accidents, please check the temperature and humidity settings regularly to eliminate the adverse
effects caused by control system failures as far as possible.
This product is not suitable to be used alone by persons who lack normal behavior ability including
children, or persons who are mentally disturbed or lacking in experience or relevant knowledge. The
persons above can only use this product under the supervision and direction of an experienced adult to
ensure safety. Children must be closely monitored to ensure that they are not playing with the device.
All accessories of this product are not recommended for other purposes, which may cause unsafe factors.
If you have any questions about the electrical installation or safety of this product, please consult a
qualied electrician. Please see the warranty conditions in the warranty card attached to this Manual. All
electrical products are equipped with a special plug. The plugs may not be modied or removed in any
way otherwise they are not covered by the warranty service.
9

TROUBLE SHOOTING
1. The LCD does not display the time after the battery insulating strip is removed:
• Check whether the battery (CR2032) is properly placed in the slot.
• If it still does not work, try replacing the battery (CR2032).
2. The LCD fails to display normally after inserting the power (only display the time at the upper left corner):
• Check if the plug is properly plugged in.
• Check if the power socket is properly powered.
• Check if the fuse reset button pops up. If yes, press to reset.
• Reset to factory settings (The fth point below is how to set factory settings).
• If all attempts fail, replace the entire device.
3. The temperature and temperature values are displayed as "-":
• Check if there is any breakage, damage, or severe indentation on the sensor cable. If yes, please replace
the sensor.
4. Time powered battery:
• It is recommended to replace the battery every six months (CR2032).
5. Reset to factory settings:
• Press the "▲" and "▼" buttons simultaneously, and then use an ejector pin to press the RESET button on
the back of the control box to reset, After the data reset display, release the "▲" and "▼" keys to complete
the factory settings.
10

A0
No.59,Liantang Road,Sanzhongcun,Qingxi Town,
Dongguan,Guangdong,China,523651
Tel: 86- 769- 87841199
Tmall: reptizoo.tmall.com
Overseas Sales: [email protected]
China Sales: [email protected]
www.repti-zoo.com
Dongguan ETAN Pet Supplies Co.,Ltd.
Table of contents
Popular Controllers manuals by other brands

Quickie
Quickie R-net user manual

EUTECH INSTRUMENTS
EUTECH INSTRUMENTS ALPHA CON 200 CONDUCTIVITY... instruction manual

MYTORQ
MYTORQ MYPC40-500 Operation and maintenance manual

Froling
Froling Lambdatronic H 3200 T4 operating instructions

Siemens
Siemens PXC Modular Series installation instructions

Honeywell
Honeywell AutoRAE 2 user manual