RGB Technology ZAS10-L PoE User manual

OPERATION AND MAINTENANCE MANUAL
ZAS10-L PoE CLOCKS
Product code:
301-D3-53
*Explanatory figure

2 DTR_301-D3-XX-001_EN_a
Table of content
1 Manufacturer .....................................................................................................................................................................3
2 Specifications......................................................................................................................................................................3
3 Transport and storage ........................................................................................................................................................3
4 Device construction............................................................................................................................................................3
4.1 Dimensions of the ZAS10-L PoE device......................................................................................................................4
4.1.1 Mounting the ZAS10-L PoE device ....................................................................................................................4
5 Installation of the device ....................................................................................................................................................4
5.1 ZAS10-L PoE application ............................................................................................................................................5
5.2 ZAS10-L PoE configuration.........................................................................................................................................5
5.2.1 Configuration of the device through the embedded website - Web panel ......................................................5
5.2.2 Configuration of the device through the IR remote..........................................................................................5
6 Accuracy .............................................................................................................................................................................6
7 DHCP...................................................................................................................................................................................6
8 Automatic brightness control of the device .......................................................................................................................6
9 Additional options ..............................................................................................................................................................6
9.1 Cooperation between clocks .....................................................................................................................................6
10 Initial start-up .....................................................................................................................................................................7
11 Disposal and recycling ........................................................................................................................................................7
11.1 Recycling of the package ...........................................................................................................................................7
11.2 Disposal of the device................................................................................................................................................7
12 Most common installation errors.......................................................................................................................................7

DTR_301-D3-XX-001_EN_a 3
1Manufacturer
RGB Technology Sp. z o. o.
76-
POLAND
2Specifications
ZAS10-L PoE
Dimensions of the device (WxHxD):
350mm x 170mm x 44mm / 13.8in x 6.7in x 1.7in
Display format:
HH:MM
Digit height:
101,6mm / 4in
Weight of the device:
1.7kg / 3.75lbs
Casing tightness rating1IP:
4X
Power supply:
IEEE 802.3af(PoE), IEEE 802.3at (PoE+)
Average power consumption of the device:
3,5W
Device operation temperature (ambient):
- / -13F 113F
Device operation temperature (device surface)
- / -13F 140F
3Transport and storage
Care should be taken to properly protect the devices so as to eliminate any damage during transport. It is forbidden to
transport the devices in a collective package without adequate amortisation - each device must be packed
separately and cannot have freedom of movement during transportation.
Due to the protective packing the module should be stored in the temperature not lower than -25
4Device construction
ZAS10-L PoE is cased in a powder-coated steel housing. The properly installed device meets the IP4X tightness
requirements.
The figure shows ZAS10-L PoE clock2.
det. A - case; det. B - AM/PM indicator; det. C - synchronization error indicator; det. D - lighting sensor; det. E - lR sensor;
det. F - cable outlet; det. G - Ethernet connector
fig. 1
1Specified on the basis of EN 60529.
2Explanatory figure.

4 DTR_301-D3-XX-001_EN_a
4.1 Dimensions of the ZAS10-L PoE device
All the dimensions shown in the drawings are given in [mm].
fig. 2
4.1.1 Mounting the ZAS10-L PoE device
fig. 3
5Installation of the device
Proper installation consists in mounting the device in one of ways proposed by Producer. Only the correct
installation of the device ensures its proper operation and maintaining the device parameters. The housing, due
to its construction, does not protect the device against water ingress and water impact. Therefore, avoid placing
it the areas where there is a risk of flooding.
NOTICE!
Before any installation or maintenance operations refer to the manual supplied by the manufacturer. Improper
connection to the mains power supply, incautious device installation, or improper use may cause the property
damage, loss of health or death from electrical shock! In addition, any failure to follow the manufacturer's
instructions may void your warranty.
NOTICE!
It is forbidden to make any additional mounting points or any holes in the device assembly components.
In standard way the device is mounted on flat surface using the factory mounting holes on the back of the
device.

DTR_301-D3-XX-001_EN_a 5
5.1 ZAS10-L PoE application
The ZAS10-L PoE device is designed to display time and date. Additionally the clock could be used as a time
standard for other devices. For the proper operation of the device, it should be correctly configured.
5.2 ZAS10-L PoE configuration
The configuration process consists in personalising the device by a user. In standard the device is configured
using LAN interface and optionally it could be done using IR remote sold separately.
5.2.1 Configuration of the device through the embedded website - Web panel
To connect with the clock, first you should configure the network card of the computer to which it is connected.
The proper configuration of the network card can be downloaded from http://rgbtechnology.pl/soft/. Having
configured the network connection correctly, you can, through a Web browser, connect with the embedded
website (Web panel), where you can personalise the device. On the embedded clock website, you may use the
following tabs:
TIME -> tab allowing you to configure the parameters connected with time;
DISPLAY -> tab allowing you to configure the parameters connected with the device display;
ADVANCED -> tab allowing you to configure the advanced parameters of the device;
STATUS -> tab allowing you to read the device status.
The detailed description of the tabs is available in the device operation manual instr_hardware_037.
5.2.2 Configuration of the device through the IR remote
The basic configuration method is by means of the remote control through the user menu. fig. 4 shows the
remote control, along with the explanation of the function of each button. You enter the user menu using the
MENU button. You navigate and modify the respective parameters using the buttons ↑,↓,←and →.
det. A Change the parameter (VALUE PLUS/VALUE MINUS) det. B move to the next position (PREVIOUS/NEXT);
det. C
fig. 4
Main menu structure:
Menu position
Function description
F1
Manual setting of the time and the date
F2
Configuration of the presented parameters
F3
Configuration of the time and date format, time colon behavior
F4
Configuration of the time synchronization
F5
Configuration of the display brightness
F6
Unavailable
F7
Configuration of the ECO mode
F8
Unavailable
F9
Restoring the default settings
F10
Unavailable
F11
Configuration of display synchronization
F12
Unavailable
F13
Regional settings, such as location, time zones, daylight saving time/standard time
F14
Stopwatch function / timer counting up / timer counting down

6 DTR_301-D3-XX-001_EN_a
6Accuracy
In standard the accuracy of the device is based on the built-in RTC quartz crystal oscillator. Declared accuracy
- 1 minute per month.
To eliminate the RTC clock aberration (loss or gain) and increase accuracy, the device can be synchronized with
the alternative time standard. Declared in Table 1 aberration in regard to the time standard is non-recurring and
non-cumulative.
Time standard
Communication method
Aberration in regard to the time standard
NTP time server
LAN
depends on server, maximum: +/- 20 ms
Master clock
LAN
depends on accuracy of the master clock
Table 1
Notice! During the first time synchronization or resume (e.g. after signal loss), the device recovers full accuracy
after 40 to 80s.
7DHCP
The device has a DHCP client function. Thanks to this, it can automatically obtain configuration data such as
IP address, gateway IP address and subnet mask from a DHCP server (e.g. router).
8Automatic brightness control of the device
In the standard version, a lighting sensor is included. The device, in response to the ambient lighting conditions,
adjusts the brightness of the clock display.
9Additional options
9.1 Cooperation between clocks
The device with LAN support has an option to cooperate with other clocks through the network. In this system
the Master clock is a time standard for Slave clocks. Also it controls the displayed information. Thanks to that all
the clocks show exactly the same time and type of information e.g. display the temperature simultaneously. The
cooperation is possible between different models of RGB Technology clocks.

DTR_301-D3-XX-001_EN_a 7
10 Initial start-up
Step 1: Connect the device to the IEEE 802.3at compliant power supply,
Step 2: Properly connected system should display pre-set (current) time and date.
11 Disposal and recycling
11.1Recycling of the package
The packaging materials must be segregated , then recycled in accordance with local regulations for
waste disposal regulations.
11.2Disposal of the device
The device can not be disposed with regular household waste!
According to Directive 2002 / 96 / EC ( WEEE ) , when repair is not economically reasonable, user is
obligated to hand over damaged or destroyed device to an appropriate disposal facility .
12 Most common installation errors
1. Device installed contrary to the instructions,
2. Drilling additional holes in the casing.
Due to the fact that the product is constantly being developed, the data presented are subject to change
without notice.
This manual suits for next models
1
Table of contents
Other RGB Technology Clock manuals