D HOW TO SET THE PARAMETER:
Step 1: Press the“Set” key for 3 seconds, the display will show the function code.
Step 2: Choosing the setting by Up and Down keys, after having chosen the indicated item, press the Set key and enter the setting of
this function. The second digit will be shown on the right of the display, indicating the related function(please refer below chart for
details). Using the Up and the Down Keys to choose the setting function and press the Set key to save.
“OP”: The system is in normal operation To
program, press SET button for 3 seconds,
when the LED display change from OP to 1,
press UP or DOWN to change function
settings (1 to P). Then press SET to enter the
sub function within each group, press UP or
Down to select sub functions and press SET
for confirmation.
E PROGRAMMABLE FUNCTION SETTINGS
LED
Definition
Function
Value
Description
1 Operation Direction 11
Open to the left (Default)
12
Open to the right
1.The function can adjust the direction of gate opening.
2.The default setting is "11".
11
12
Gate Closed
Open to the left
Gate Closed
Open to the right
2 Auto-Closing
3 Safety Device Function
Mode
4 opening operation speed
5 closing operation speed
6 Deceleration point
7 Deceleration speed
20
No auto close (Default)
21
5 seconds
22
15 seconds
23
30 seconds
24
45 seconds
25
60 seconds
26
80 seconds
27
120 seconds
28
180 seconds
31
Mode 1 (Default)
32
Mode 2
33
Mode 3
41
50% operating speed, 50% learning speed
42
70% operating speed, 50% learning speed
43
85% operating speed, 50% learning speed
44
100% operating speed, 50% learning speed (Default)
51
50% operating speed, 50% learning speed
52
70% operating speed, 50% learning speed
53
85% operating speed, 50% learning speed
54
100% operating speed, 50% learning speed (Default)
61 75%
62 80%
63 85%
64
90% (Default)
65
95%
71 20%
72 30%
73
40% (Default)
74
50%
1.Thefunction canbeusedtoclose the gate
automatically after the paused time.
2. Thedefault settingis"20”: No auto closing time.
3. Auto-closing function can be deactivated by long pressing
“F.F feature (please refer to the last parameter setup)” key for
two sec.
The gate will slide to fully open position and all the operations
will be locked until long press the “F.F feature” key for 2 sec
again to re-activate the auto-closing function again.
1. Please do the function setting after H & J
2. The default setting is “31”.
3. Please refer to F3 function settings at page 9
1.The function can adjust the running speed of motor.
2.The default setting is "44".
Motor operationfrom deceleration zone: the motor will followthe
learning speed until it touch the limit switch
Motor operation from other zone: The motor willcost 1 sec from
stop to full speed and it will stop till it approaches the limit switch.
1. The function can adjust the running speed of motor.
2. The default setting is "54".
Motor operationfrom deceleration zone: the motorwill follow the
learning speed until it touch the limit switch
Motor operation from other zone: The motor willcost 1 sec from
stop to full speed and it will stop till it approaches the limit switch.
1. The default setting is “64”
1. The default setting is “73”
7