Ridder LogicLink RLL400 User manual

265340EN - 2019.12 - V04
Original product-manual
Ridder LogicLink RLL400
Product Manual
Lorentzstraat 32
3846 AX Harderwijk
PO Box 360
3840 AJ Harderwijk
the Netherlands
T+31 (0)341 416 854
F+31 (0)341 416 611
Iridder.com
Einfo@ridder.com
Ridder Drive Systems B.V.

TABLE OF CONTENTS
1. GUIDELINES, STANDARDS AND CONDITIONS
1.1 Applicable guidelines and standards 3
1.2 Approved personnel 3
1.3 Warning about discouraged use 3
1.4 Warranty provisions 3
2. SAFETY, PRECAUTIONS AND SYMBOLS
2.1 Signal words, instrucons and warnings 4
2.2 Precauons and safety instrucons 4
2.3 Residual risks 6
2.4 Symbols and abbreviaons 6
3. PRODUCT DETAILS
3.1 Idencaon 7
3.2 Descripon 8
3.3 Applicaon 8
3.4 Dimensions 9
3.5 Technical specicaons 10
4. INSTALL INSTRUCTIONS
4.1 Special tools and equipment 12
4.2 Installaon 13
5. CONNECT INSTRUCTIONS
5.1 Electrical material 13
5.2 Protecon - Condions and starng points 14
5.3 Overview and funcon diagram 15
5.4 Wiring diagram: Control board (RCB) 15
5.5 3-phase electric motor (208-600 VAC) 16
5.6 1-phase 3-wire electric motor (115-230 VAC) 17
5.7 1-phase 5-wire electric motor (115-230 VAC) 17
5.8 Automac control (ACS) (24 V AC/DC) 18
5.9 OPTIONAL - Manual control (MC) 18
5.10 OPTIONAL - Posion Feedback (RPU) 19
5.11 OPTIONAL - Alarm (AL) 20
6. USER INSTRUCTIONS
6.1 Usage - Condions and starng points 21
6.2 Status LEDs 21
6.3 Operaon 22
6.4 Alarm 23
6.5 Safety funcons and stop funcons 23
7. COMMISSIONING INSTRUCTIONS
7.1 Commissioning - Condions and starng points 24
7.2 Check: Control direcon of the Automac Control (ACS) 25
7.3 Check: Control direcon of the Manual Control (MC) 26
8. MAINTENANCE INSTRUCTIONS
8.1 Maintenance 27
9. SERVICE
9.1 Troubleshoong 27
9.2 Blink codes 28
9.3 Technical support 29
10. ENVIRONMENT
10.1 Decommissioning and removal 30
10.2 Waste disposal 31
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
2

1. GUIDELINES, STANDARDS AND CONDITIONS
1.1 Applicable guidelines and standards
This product complies with the provisions of the European guidelines that follow:
Machinery Direcve 2006/42/EC | Low Voltage Direcve 2006/95/EC | EMC Direcve 2004/108/EC
The harmonized standards (or parts of these standards) that follow are applicable:
NEN-EN-ISO 12100:2010 | NEN-EN-IEC 60204-1 |
NEN 82079-1 (62079: 2001) | NEN5509 | ISO 3864-2
Make sure that this product is only put into operaon if the system (in which it will be installed)
complies with the provisions of the applicable standards and guidelines.
1.2 Approved personnel
This product manual contains important informaon for installers about the installaon and
commissioning of a Ridder LogicLink RLL400 control-unit. Read this product manual and instrucons
rst before the work starts. Approved mechanical and/or electrical installers, with professional
competence, must do all work safe and responsible.
TARGET GROUP FOR EACH CHAPTER CHAPTER (refer to Table of Contents)
TARGET GROUP 1 2 3 4 5 6 7 8 9 10
User (operator) • • • • (•)
Installer / Approved personnel • • • • • • • • • •
(•) = Not fully applicable
Keep this product manual with the product during the lifespan. Make sure it is available for users
(operators), installers and approved personnel.
1.3 Warning about discouraged use
The condions that follow are applicable:
• Do not change (the construcon of) the LogicLink RLL400 control-unit.
• It is not permied to use the RLL400 control-unit to li or move people.
• Do not let the torque of the motor gearbox be more than its maximum.
• Do not let the duty cycle of the motor gearbox be more than its maximum.
Refer to §3.3 for a descripon of the intended use.
1.4 Warranty provisions
For the warranty period and condions refer to the ‘Condions’ secon on our website at ridder.
com, or in the Ridder catalogue.
Regulatory Conformity
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
3

2. SAFETY, PRECAUTIONS AND SYMBOLS
2.1 Signal words, instrucons and warnings
Signal words (ISO 3864-2)
This product manual contains safety instrucons with dierent signal words. The list that follows
gives the risk levels and possible eects of each signal word.
Instrucons and warnings on the product
Read the product manual to fully know all product properes,
before it is used or work starts!
Ê
It is not permied to use high-pressure cleaners (and related
cleaning agents)! Use a so brush with a small quanty of water
without cleaning agents.
Warning - Electrical voltage
Aer installaon interchange the plug in the highest posion
with the vent plug! Refer to the permied mounng posions in
the product manual.*
* Not applicable to the RW45 motor gearbox!
2.2 Precauons and safety instrucons
Precauons
GENERAL
A system can be dangerous. Safety precauons and instrucons are important.
• If these precauons cannot be obeyed, then use warnings.
Suggeson to perform an operaon more eecve.
May result in damage or problems if an acon is performed
incorrectly.
May result in minor injury if the hazard is not avoided.
Signicant injury, possible death, if the hazard is not avoided.
Severe injury and possible death if the hazard is not avoided.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
4

• The responsibility for precauons and warnings lies with the installer of the system. Refer to the,
local or naonal, laws and regulaons of the country if a cercaon (mark) is necessary.
• Parts of the electrical or electronic installaons are connected to dangerous electrical voltages.
Work without professional competence or not obeyed warning instrucons could cause injury
and/or material damage.
• Ridder is not responsible for injury, material damage or consequenal damage if accessories are
used that Ridder did not make.
TRANSPORT, STORAGE AND PACKAGING
The condions and instrucons that follow are applicable.
• Ambient temperature: -15 to +60 °C (+5 to +140 °F).
• Ambient: A not-condensed relave humidity is necessary.
• Do a check for transport damage and missing parts immediately on incoming goods.
• Tell damages and missing parts immediately to the transport company and to your local Aer
Sales contact person.
• Do not use damaged products and if necessary do not start the work.
• Send the product to the installaon site before it is removed from the (sealed) packaging. This
prevents damage (from mechanical shocks) to the product.
• Use applicable means-of-transport with dimensions which are sucient. Use (if necessary) the
correct work equipment and accessories. Refer to “Dimensions” and “Technical specicaons”.
Make sure that the working condions comply with the, local or naonal, laws and regulaons.
• Make sure that storage areas and the areas in the means-of-transport are dry and the airow is
sucient.
• Make sure that the products do not touch the (moist) boom surface of storage areas and of the
means-of-transport (use pallets or such). The boom surfaces must be smooth.
• Make sure that the products are protected from dust, dirt and direct sunlight.
• Apply an applicable corrosion-prevenve agent to surfaces that are not painted.
• Aer installaon discard the packaging and obey the applicable naonal and/or local regulaons.
Safety instrucons
• Use (if applicable) personal protecve-equipment for protecon which agrees with the dierent
types of work.
• Do not let persons and not approved personnel be near controls and systems in operaon.
• Damaged systems must be stopped immediately unl they are repaired.
• Use safety barriers, for system parts that move, to a height of 2.5 m from the ground.
• The safety distance to the danger zone (if applicable) must agree with ISO 13857:2008.
• Do not operate systems when persons are in the danger zone and can touch the system.
• Monitor the danger zone when you work with or near the system.
• Stop and de-energize systems during maintenance and cleaning work on or near the system.
• Make sure that there is sucient space between parts that move and adjacent objects.
• Stay away from or safety areas where there is a risk to become caught in a system that moves.
• The torque and the duty cycle of the system must be in the range of the motor gearbox
parameters. Refer to the product manual of the used Ridder motor-gearbox at ridder.com.
If you do not obey the safety instrucons that follow it can be
dangerous and cause injury.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
5

2.3 Residual risks
Automac controls
The Ridder drive-units are usually used in automac controlled systems. Persons who do work or
stay near the system must know about that. If persons or their clothes touch the system during
operaon, it can be dangerous.
Forces
Because of the forces in the systems (in which the drive unit is installed), Ridder cannot be sure that
there will be no injury to persons or damage to the system.
2.4 Symbols and abbreviaons
This secon tells about used symbols and abbreviaons in this manual. The table that follows gives
the descripons.
Symbol Description Symbol Description
1L1 Power IN (A2) MC Manual Control (external)
3L2 Power IN (A2) MPCB Motor-Protecon Circuit-Breaker
5L3 Power IN (A2) N Neutral wire
2T1 Power OUT (EM) PE Protecve earth
4T2 Power OUT (EM) PTC PTC thermistor
6T3 Power OUT (EM) RCB Ridder control-board
ACS Automac control-system RLL Ridder LogicLink
AL Alarm (circuit) RLS Limit-switch system
A1 RLL400 housing RPU Digital posioning-meter
A2 Control board RSU Limit-switch system
D1 Status LED - Green RW Motor gearbox
D2 Status LED - Red X1 Power input (RCB)
D3 Status LED - Red X2 Power output (EM)
D4 Status LED - Red X3 Transformer
EM, M Electric motor, Motor X4 PTC input
ES11,ES12 Duty switch RSU/RLS X5 Fault-contact output
ES21,ES22 Safety switch RSU/RLS X6 Automac-control input
GND Return wire of control signal (ACS) X7 RPU reference-input
ICurrent in Amperes (A) X8 Manual-control input
L1, L2, L3 Voltage source X9 Limit-switch input
Persons can be in danger of life if they touch a system that is in
operaon.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
6

3. PRODUCT DETAILS
3.1 Idencaon
EXAMPLE
Ê
This product manual is only applicable to:
• Ridder LogicLink RLL400 control-unit
• Serial numbers from 200.900.000
• Item numbers from 500000.
Idencaon is possible from the scker on the locaon shown.
Refer to the explanaon that follows on how to read the informaon.
For more informaon on item numbers and models refer to the
Ridder catalogue or website at ridder.com.
RW1400: RW1000 /1400, RW1200/1600S or RW2000S.
1-5D: 1~ mains voltage, 5-wire electric motor.
Alternatives
1-3: - 1~ mains voltage, 3-wire electric motor.
- 3~ mains voltage.
3: 3~ mains voltage.
Alternatives
115-400: Mains voltage 115 V/230 V (1~) or 208 V/400 V (3~).
RLL400: General designaon Ridder RLL400 control units.
1~ = 1-phase
= No symbol in idencaon. RW45, RW200, RW240/400/600 or RW800 motor gearbox.
( - ): RW45, RW200, RW240/400/600 or RW800.
3~ = 3-phase
400: Mains voltage 400 V (3~).
440-600: Mains voltage 440 V, 480 V or 600 V (3~).
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
7

3.2 Descripon
The RLL400 is a control unit to control a Ridder RW motor-gearbox. The
control unit is part of drive units with motor gearboxes type RW45,
RW200, RW240/400/600, RW800, RW1000 /1400, RW1200/1600S or
RW2000S.
The control unit is applicable to:
• Dierent supply voltages
• Dierent mains frequencies
• 3-phase and 1-phase voltages.
The control unit has a control board with a microprocessor and a semiconductor relay.
The control board has connecons for:
• The supply voltage
• The power supply for the electric motor (EM)
• An automac control signal (24 V AC/DC) from an automac control-system (ACS)
• A manual control (MC)
• A fault contact (NC) that can be part of an alarm circuit
• The PTC thermistor in the electric motor (EM) (if applicable) for thermal protecon
• A digital posioning-meter (RPU).
The limit-switch system is also connected to the control board of the control unit.
The RLL400 control-unit transmits control signals from the automac control-system (ACS) or
manual control (MC) and monitors if these are processed without malfuncons. The control unit has
rotaonal-eld detecon and phase detecon of the supply voltage.
The 24 V AC/DC control input is protected from:
• Control in two direcons at the same me
• Sudden changes of direcon.
The control unit has status LEDs to show error messages of the system.
The RLL400 control-unit has plug connectors and terminal strips to connect the cables. To pull the
cables through, out of the housing, the control unit also has cable glands. The protecon rang of
the RLL400 housing is IP54.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
8

3.3 Applicaon
The LogicLink RLL400 control-unit is installed, as part of a drive unit, on dierent RW motor-
gearboxes. The control-unit is used to control the motor gearboxes in two direcons-of-rotaon.
The RLL400 control-unit (on dierent RW motor-gearboxes) is applicable to:
• Venlaon systems
• Screen systems.
For other (dierent) applicaons, approval from Ridder Drive Systems is necessary.
3.4 Dimensions
Note: The dimensions and illustraons are approximate. In this product manual shown illustraons
can be dierent than the components and/or systems.
M16(4x)
200
90
64
90
70
490 182
268.5
M20(3x)
Example:
M16(4x)
200
64
90
70
490 182
268.5
M20(3x)
Example:
M20(1x)
503.5
117
83
78
150
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
9

3.5 Technical specicaons
Mechanical
Dimensions (WxHxD) RW45 - RW800: 490 mm x 90 mm x 200 mm
RW1000 - RW2000: 503.5 mm x 117 mm x 200 mm
Weight 3.1 - 5.4 kg
Ambient
Protecon rang IP54
Ambient temperature 0 to +60 °C (+32 to +140 °F)
Maximum relave humidity 95%
The three types of control boards (RCB) that follow
are available for the RLL400 control-unit.
RCB-A (Type A):
50/60 Hz AC
1~ 115V-230 V, 12FLA, 72 LRA
3~ 208-400 V, 12 FLA, 72 LRA
RCB-B (Type B):
50/60 Hz AC
3~ 400 V, 10 FLA, 60 LRA
RCB-C (Type C):
50/60 Hz AC
3~ 440-600 V, 10 FLA, 60 LRA
Refer to the table that follows for abbreviaons,
technical specicaons and descripons of all
connecons.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
10

Electrical
Supply voltage
X1 Power supply Type 1-phase (1~) 3-phase (3~) Current
1L1
3L2
5L3
N*
RCB (A2)
RCB (A2)
RCB (A2)
RCB (A2)
Input
Input
Input
Input
RCB-A
1x 115 VAC
1x 230 VAC
RCB-A
-
-
3x 208 VAC
3x 400 VAC
RCB-B
3x 400 VAC
RCB-C
3x 440-480 VAC
3x 600 VAC
Max 12 A
X2 Power supply Type
2T1
4T2
6T3
N*
Electric motor (EM)
Electric motor (EM)
Electric motor (EM)
Electric motor (EM)
Output
Output
Output
Output
*N is only there on RCB-A.
X3
RCB-A
Transformer Supply voltage
1 2 3 4 5 Type 1-phase (1~) 3-phase (3~) Current
1~ Loop connecon 1x 115 VAC N.A. ~16 mA
1~ Loop connecon 1x 230 VAC N.A. ~10 mA
3~ Loop connecon N.A. 3x 208 VAC ~10 mA
3~ Loop connecon N.A. 3x 400 VAC ~ 4 mA
(X3)
RCB-B
Transformer Supply voltage
1 2 3 4 5 Type 3-phase (3~) Current
3~ N.A. N.A. N.A. 3x 400 VAC
X3
RCB-C
Transformer Supply voltage
1 2 3 Type 3-phase (3~) Current
3~ Loop connecon N.A. 3x 440-480 VAC
3~ Loop connecon N.A. 3x 600 VAC
X4 PTC IN Type Supply voltage Current
1PTC Input 0.25 V DC 1 mA
2PTC’ Power supply 0.25 V DC 1 mA
X5 Fault contact OUT Type Supply voltage Current
1 Not connected Loop-connecon pin Max 350 V Max 50 mA
2Fault OUT Switching contact Max 350 V Max 50 mA
3Fault OUT’ Switching contact Max 350 V Max 50 mA
X6 ACS Type Supply voltage Current
1Direcon B Input 24 V AC/DC 10.5/10 mA
2Common Ground Ground 10.5/10 mA
3Direcon A Input 24 V AC/DC 10.5/10 mA
X7 RPU Type Supply voltage Current
1+24V Power supply 24 V DC 50 mA
2RPU CALIBRATION A Output 24 V DC 0.5/1 mA
3RPU CALIBRATION B Output 24 V DC 0.5/1 mA
4 Neutral wire Power supply
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
11

Electrical
X8 MC Type Supply voltage Current
1+24V Power supply 24 V DC Max 15.7 mA
2Direcon A Input 24 V DC 2.1 mA
3 Auto Input 24 V DC 2.1 mA
4Direcon B Input 24 V DC 2.1 mA
5 LED Output 24 V DC 4.7 mA
6 LED Output 24 V DC 4.7 mA
X9 Limit switch IN Type Supply voltage Current
1Common Power supply 7 V DC 3.3 mA
2Direcon B Input 7 V DC 1.1 mA
3Direcon A Input 7 V DC 1.1 mA
4Safety Input 7 V DC 1.1 mA
D1-D4 LED
D1 Green
D2 Red
D3 Red (RPU)
D4 Red (RPU)
4. INSTALL INSTRUCTIONS
Installaon is only permied to approved personnel. The RLL400 control-unit is available, as part of
a drive unit, on a RW motor gearbox.
Do a check of the supplied parts in the table that follows.
Parts list *
580000-RLL400 control unit 1x 500000P-RW motor gearbox (RLL type)** 1x
* Minimum parts list: Drive unit without oponal parts and accessories.
** Motor gearboxes have spring washers and bolts M10x20 (2x), M10x25 (3x/4x) or M12x25 (4x).
NOTE: Bolts M12 (4x), spring washers and nuts are accessories for RW1000 thru RW2000 motor gearboxes.
4.1 Special tools and equipment
No special tools or equipment are necessary to install, to connect or for commissioning.
Make sure that the correct equipment and tools are used.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
12

4.2 Installaon
The condions and starng points that follow are applicable for installaon. Make sure that the
working condions comply with the, local or naonal, laws and regulaons.
• Do not remove the product from the packaging unl a short me before the installaon.
• Use the correct work equipment and accessories (belts, chains, pallets or such) if it is not
permied or possible to put the product manually in posion.
• Ridder installed the RLL400 control-unit on a RW motor gearbox.
• Only use a permied mounng posion when you install the RW motor gearbox with control-
unit. Refer to the product manual of the used RW motor-gearbox at ridder.com.
• The RLL400 gives informaon about the system with LEDs on the control board. Thus, easy access
and a sasfactory view is recommended for the locaon of the RLL400.
5. CONNECT INSTRUCTIONS
Only to approved personnel it is permied to do the connect instrucons.
Removal cover
• Remove the bolts (8x) and the cover temporarily to do all necessary work. The gasket usually
stays in its posion.
• Make sure that no damage is caused to the gasket and that it does not become dirty. To prevent
this remove the gasket (carefully) if necessary.
• Install the cover again aer the work! Refer to the end of chapter 7.
5.1 Electrical material
A minimum conductor diameter of 1.5 mm² is applicable to the cables in the wiring diagrams. For
the used components, electrical material and cable lengths the necessary conductor diameter can
be dierent.
Make sure that the drive unit is installed in a stable condion. The
structure must have sucient strength for the applied forces.
Make sure that easy access to the cover of the RLL400 control-unit is
possible for all work.
HEX 4 mm (8x)
Use only applicable components and electrical material.
Always refer to the related informaon and manuals.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
13

5.2 Protecon - Condions and starng points
The condions that follow are applicable to the wiring diagrams.
• The installer makes sure that necessary and not shown protecons are used and included in the
wiring diagrams.
• Make sure that you can see the operated system from all control units and control systems. Put
control units and control systems at a height of more than 1.5 m.
• Protect the electric connecons from moist condions.
Inducon
Problems with inducon must be prevented. Inducon can cause an interference with the
electronics.
Inducon can have many causes such as:
• Cable lengths
• External sources
• Too many cables together.
Electrical connecons are only permied to an electrical installer or
an electrician.
For installaon and maintenance work the system must be de-
energized.
Always make sure that the protecons comply with the, local or
naonal, laws and regulaons of the country.
Separaon of cables is necessary. This prevents problems with
inducon.
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
14

5.3 Overview and funcon diagram
The diagram that follows shows the RLL400 control-unit in a system. Ridder Drive Systems connects
the components (if applicable) in the framework A1.
5.4 Wiring diagram: Control board (RCB)
The diagrams that follow show:
• The RLL400 housing (A1) and the RCB control-board (A2)
• The standard connecons and oponal connecons with related connectors
• The related secons with the wiring diagrams and informaon.
Ridder connected X2, X3, X4, X7* and X9 (if applicable).
* X7 is parally connected. Refer to §5.10 and complete the connecons.
RLL400 housing:
Automac Control Alarm Manual Control
Control Board
Supply Voltage
Temperature
Limit Switch
Power supply 24 V DC
Supply Voltage
24 V AC/DC Control
Fault Contact
OPTIONAL OPTIONAL
Reference Monitoring
Posion Feedback
OPTIONAL
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
15

RLL400 control-board (RCB):
5.5 3-phase electric motor (208-600 VAC)
• Make sure that the conguraon (RCB-A or C) on X3 (TRANSFORMER) agrees with the supply
voltage!
• Ridder Drive Systems connects X2 (MOTOR) and X4 (PTC).
• Connect the supply voltage to X1 (MAINS) and PE (protecve earth).
Alarm
§5.11 OPTIONAL
§5.9 OPTIONAL §5.10 OPTIONAL
§5.5/ §5.6/ §5.7
CONTROL BOARD A2 (RCB)
Manual control Posion feedback
Power In
* X3 is not there on RCB-B
Automac Control Transformer configuration Power Out
§5.8
Limit Switch Thermal Protection
Control board A2
A1
(in) (out) (in)
4 x 1.5 mm²
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
16

5.6 1-phase 3-wire electric motor (115-230 VAC)
• Make sure that the conguraon (RCB-A) on X3 (TRANSFORMER) agrees with the supply voltage!
• Ridder Drive Systems connects X2 (MOTOR) and X4 (PTC).
• Connect the supply voltage to X1 (MAINS) and PE (protecve earth).
5.7 1-phase 5-wire electric motor (115-230 VAC)
• Make sure that the conguraon (RCB-A) on X3 (TRANSFORMER) agrees with the supply voltage!
• Ridder Drive Systems connects X2 (MOTOR) and X4 (PTC).
• Connect the supply voltage to X1 (MAINS) and PE (protecve earth).
Control board A2
A1
(in) (out) (in)
3 x 1.5 mm²
Control board A2
A1
(in) (out) (in)
3 x 1.5 mm²
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
17

5.8 Automac control (ACS) (24 V AC/DC)
You can connect the RLL400 control-unit to an automac control system (ACS). Refer to the diagram
that follows and connect the ACS. Also refer to the product manual of the ACS that is used.
Notes:
• When the two inputs of the digital control (pin 1 and 3) receive a control signal at the same me,
the control unit will not process them. The electric motor does not move.
• The external power supply can be 24 V AC/DC.
• Refer to §3.5 for the technical specicaons of the external power supply of connector X6.
Connector X6 of the control board (A2) can be connected to
automac control systems (ACS) that have a “switched ground” or a
“switched posive”.
5.9 OPTIONAL - Manual control (MC)
You can connect the RLL400 control-unit to a manual control (MC) such as the Ridder MC Module
Compact (277950).
• Remove the jumper from connecon 1 and 3 of X8.
• Connect the manual control (MC). Refer to the diagram that follows.
Refer to the related manual when you connect a dierent manual control (MC).
Control board A2
Control board A2
YES NO
MC
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
18

5.10 OPTIONAL - Posion Feedback (RPU)
You can connect a digital posioning-meter (RPU) and an automac control system (ACS) to the
RLL400 control-unit.
Ridder Drive Systems connected the wires that follow:
• The power supply (connecon 1 and 2) to connector X7 (connecon 1 and 4).
• The reference input (connecon 5) to connector X7 (connecon 2).
Complete the RPU connecons. Obey the diagram ① and the check procedure ②. Also refer to
the manual of the ACS.
① Connecng - Feedback (4-20 mA)
• Make sure that the power supply is 24 V DC from an external source.
• Connect the posion feedback (connecon 3 and 4) to the ACS.
② Check - Reference-input RPU
• Do the reference-input check (connecon 5) that follows when you want to use reference
monitoring and to set the reference again. Obey the check procedure to connect the RPU
connector X7 correctly.
uDescripon
1Select which duty switch (ES11 or ES12) you want to use as switch for the RPU reference-
monitoring. Let the motor turn in the direcon of this duty switch unl it disconnects.
To prevent damage or injury, do not go across the limit posions of
the operated system!
2LED D3 or D4 will come on on control board (A2). Obey the instrucons in 3-A or 3-B.
3-A
Blink code is 2.1. The LED D4 (RPU CAL. A) comes on. Refer to §6.2 and §9.2.
Go to step 4-A.
3-B
Blink code is 2.2. The LED D3 (RPU CAL. B) comes on. Refer to §6.2 and §9.2.
Go to step 4-B.
Control board A2
24 V DC4-20 mA
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
19

4-A
The reference-input connecon (connecon 2 of X7) is CORRECT. Go to step 5.
Control board A2
4-B
The reference-input connecon (connecon 2 of X7) is NOT CORRECT.
Interchange the connecons 2 and 3. Go to step 5.
Control board A2
5The RPU is prepared to set the end posions.
Refer to the RPU product manual at ridder.com.
5.11 OPTIONAL - Alarm (AL)
The RLL400 control-board (A2) has an output for a fault contact (X5) that opens when a random
fault occurs. You can include this fault contact in an alarm circuit.
You can connect one or more control units to an alarm circuit.
Connecng - One RLL400 control-unit
Obey the diagram that follows to connect one control unit.
Connecng - Two or more RLL400 control-units
Obey the diagram that follows to connect the fault contacts (X5) to two or more control units.
It is only permied to connect the RPU reference-input to X7 of the
control board (A2). Do NOT connect it to the RSU/RLS.
Refer to §3.5 (Technical specicaons) of X7 and X9.
Control board A2
Alarm
AL
Control board A2 Control board A2 Control board A2
Alarm (AL)
Ridder Drive Systems B.V.
T+31 (0)341 416 854 - F+31 (0)341 416 611 - Iridder.com
20
Table of contents
Other Ridder Control Unit manuals
Popular Control Unit manuals by other brands

Motorline professional
Motorline professional MC41SP User& installer's manual

LEGRAND
LEGRAND DRD5 v2 installation instructions

Siemens
Siemens SIMATIC ET 200SP Equipment manual

ADTRAN
ADTRAN Job Aid+ 1442704PG2 manual

LOVATO ELECTRIC
LOVATO ELECTRIC EXP10 15 instruction manual

SAFE TRON
SAFE TRON CU2 instruction manual

GEM
GEM 653 Installation, operating and maintenance instructions

Kohler
Kohler K-10668 Homeowner's guide

Lenze
Lenze EMF2192IB Mounting instructions

syscomtec
syscomtec SCT-IPKVM-CX user manual

PDi
PDi PD196-244R12 Installation and operating instructions

Challenger
Challenger RSGV Installation & operation manual