RB-3SS
Cut-Out Hole Size
Features
Specification
1. The tempered glass and stainless top plate is beautiful and stylish.
2.The enamel pan supports are durable and will not deform, making it stable for your cooking vessels.
3. The automatic continuous ignition device will ensure a 100% ignition rate.
4. Each built-in hob is equipped with a safety valve which will cut off the gas supply automatically if
the flame is accidentally extinguished (For SV model only).
3. Do not release the control knob for 2-5 seconds after the sparks have ignited the burner to activate the
safety device. Otherwise, the ignition will fail.
4. In the event of the burner flames being accidentally extinguished, turn off the burner control and do
not attempt to re-ignite the burner for at least 1 min.
The device shall not be operated for more than 15 seconds. If the burner has not lit up after 15
seconds, stop operating the built-in hob and open the compartment door and/or wait for at least 1
minute before attempting to ignite the burner again.
5. The flame can be controlled between “MAX” “MED”and “MIN” position, please adjust the flame
slowly.
6. For H burner, flame can be controlled with four combination, as shown by Fig. 4:
How to Handle Safety Device and Change Battery
- 5 -
7. Do not clean the top of the sensor with a hard brush, as it may damage the sensor.
1. After use, turn the control knob right to the “OFF” position, and the flame will be extinguished.
2. Make sure that the control knob is fully turned to the “OFF”position, less there would be a danger of
gas leakage.
3. After extinguishing the flame, do not touch the conductive parts of the hobs as they remain at very
high temperatures.
4. There may be a slight hissing sound after the flames is extinguished.
5. If the built-in-hob is not in use, turn off the main gas supply to avoid gas leakage or unnecessary
accidents.
Flame Extinguishing
Fig. 5
- 2 -
Gas Inlet
Front Side
”C” Size Battery
(1.5Vx1)
1. If the flame is extinguished during operation, the Flame Failure Safety Device will automatically cut
off the gas within second.
If you notice that the flame has been extinguished, please turn the knob to “OFF” position.
2. The Safety Sensor is delicate, please do not use stiff brushes or rough cleaning pads when cleaning.
•Aeration is preset at factory during assembly; please do not attempt to adjust it.
•Battery Box is located at bottom of right front (Size C, 1.5V x 1) (Fig.5).
Open the cabinet door, and change the battery.
out side flame
inside flame
: Max
: Max
: Off
out side flame
inside flame : Max
: Off
out side flame
inside flame : Min
out side flame
inside flame
: Medium
: Medium
Fig. 4
R0 ~ R110
725~840
65
435~480
550
Gas Type
Gas Consumption per hour
Respective gas consumption (kW)
Main
RHS / LHS (kW) Gas Connecting Tube
3.60
2.70
3.90
1.35
L.P.G (30 mbar)
Nozzle/injector size
4.20
0.95
Ø9.5 mm gas specific
rubber hose
½ In Thread (male)
Ø9.5 mm gas specific
rubber hose
Simmer
1.00
1.35
0.80
0.65
0.50
0.36
T.G. (8 mbar)
Nozzle/injector size
N.G. (25 mbar)
Nozzle/injector size
Main
Center
2.10
1.90
2.30
0.73
2.20
0.73
Product
Net Weight
Model
Automatic
Continuous Ignitions
Overall
Dimension
Cut out size
Built-in Hob
RB-3SS
17 Kg
21 Kg
435~480 mm x 725~840 mm
R0 mm ~ R110 mm
“C” Size Battery (1.5V x 1)
RB-3SS (S)
RB-3SS (GB)
RB-3SS (S)
RB-3SS (GB)
Diameters of pan which may be used on hob
* Use only flat bottom pan except for wok burner
Burners
280 mm
Max
Main
Min
120 mm
870 mm x 510 mm x 131 mm
880 mm x 520 mm x 131 mm