Rinnai RSK-500 User manual

User’s manual
GAS SOUP KETTLE
RSK-500
Read t his manual before using t he product so t hat any pot ent ial risk can be prevent ed in advance.
Keep t his manual at any place where it can be easily found.
Features and Functions
Thank you very much for choosing our product . This manual is designed t o
prevent physical damage or loss caused by careless use. Please read t his guidebook
and enj oy your t ime wit h our product .
Piezoelect ric t ype of aut omat ic ignit ion for convenience
At t achment of e t inguishment safet y device for safet y
Wit h t he use of aluminum ket t le, product is light weight and cooking t ime is
short ened.
Wit h enamel-coat ed body, product is corrosion resist ing and splendid e t erior
design.
Folding t ype of ket t le lid for convenience
Cooking capacit y(130 ~180 ) is engraved in ket t le for easy use
Wit h 360 rot at ion available, it is convenient t o use and clean.
Wit h Ket t le leg made of st ainless st eel, it has e cellent durabilit y.
Ignit ion checking window is equipped for convenience.
If you only use wat er, ket t le might be decolorized but it is no harm for you t o
use product .
Assemble “ Ket t le Lid Knob”
It is acked inside of kettle along with user’s manual. For assembling, lease
refer to age 10 in the user’s guide before using.

Safety Warning
-This is designed t o help you prevent any accident s caused by mishandling of product . And enable t o
use product more convenient ly wit h easily underst andable illust rat ions. Please keep in mind marks
below and underst and before you read user’s manual
If you ignore t his mark and misuse, you can die or get severe
If you ignore t his mark and misuse, you can get severe inj ury
If you ignore this mark and misuse, you can get harmed and get physical damages
Keep in mind marks below and underst and before you read user’s manual
General danger,
warning and caution
General
rohibition
Wire must be
grounded
Inflammabl
Danger
If gas leakage is det ect ed…
Do not turn on the light, and do not touch switch control late or ower cord to electric
a liances. Also, do not use tele hone. They can cause inflammable ex losion.
Measures 1) Sto using immediately, and close intermediate valve
2) O en the window and ventilate air
3) Call for after sales service center. Do not use nearby hone or
mobile hone but use outside tele hone.
Thiol is included in su ly gas, you can detect gas leakage right away in the resence
of 1/ 1000 ratio of thiol in the air.(Similar to garlic, rotten egg smell)

Warning
Do designated gas
-Make sure su ly gas is the same as the gas ty e stated
in roduct data late. If it isn’t consistent, it could
cause gas oisoning and ex losion due to incom lete
combustion. In addition, ignition might not take lace.
-Data late is on the right side of roduct.
(if you don’t know su ly gas ty e, call for service center) Must do
Do not absolutely using middle-low middle
ressure.
- It is designated the low ressure. If not, there is a
danger of breakdown and fire
Gas connection must be done by an authorized gas su ly
agency or gas i e installer.
-Gas related tools using for gas combustion have to have acquired KS mark or
assed ins ection by Korea Gas Safety Cor oration. Also check validity
eriod -When you connect gas hose, ush it to red line in gas connector
and tighten using a fastener Do designated gas
-Do connect to the rubber hose( 9.5mm), there is a danger of incom lete combustion.
Don’t close to your face at control anel.
When you control anel.
-It will be burn a skin by a hot steam and ex losion
combustion.
-When you check the statue of fire through control anel,
kee a distance 50cm over the control anel.

Warning
On combustion, Check the quantity of inside
materials.
-On using, inside material was eva orated. The cattle
become a em ty. So, it caused breakdown and fire.
Do not combustion when the kettle was em ty.
-When the kettle was combustion with em ty, it will
cause breakdown and fire. Therefore, do not
combustion when the kettle was em ty.
Must do
General
rohibition
Do not kee inflammables close.
- Do not use inflammable gas such as s ray nearby.
-Do not kee any inflammables such as curtain,
s ray, gasoline and benzene around roduct. It
could cause fire
Do not go away while switch is on
-If roduct is overheated, it could cause a
breakdown or fire. In articular, if you leave
roduct for a while, fire may take lace.
Must do
Don’t sto the ventilation
If you sto the ventilation hole by tower, it will cause
a breakdown or fire by a incom lete combustion
General
rohibition Caution for unusual case
- When you detected the strange noisy,
incom lete combustion, smell, lease, sto
the intermediate valve immediately
General
rohibition Must do

Warning
Do not dismantle, re air or modify
roduct exce t authorized rofessional .
- This could damage roduct safety. When you
think roduct is in trouble, refer to user’s
manual or contact our service center .
Do not touch roduct during the use of
roduct or sometime after using it.
-Gill art and to late of roduct is very hot.
You could get burned
General
rohibition
No Touch
Kee roduct out of children’ reach.
-Do not allow children get closer, they could get
burned.
Do not touch roduct during the use of
roduct or sometime after using it.
-Gill art and to late of roduct is very hot.
You could get burned
Must do General
rohibition
Consult with gas su lier or installer for gas
connection and roduct installation.
-We are irres onsible for any accidents caused by
wrong gas connection or roduct installation
Be careful not to get burned, right aft er
o eration or during o eration.
-Kettle is very hot and filled with a high tem erature of steam
during o eration or right after o eration. You could get burned
on your hands or face etc.
-Do not touch kettle when you o en the lid. Kee away your face
from the roduct as much as you can and hold “kettle lid knob”
then o en the lid slowly by letting inside stem outside.
Must do Must do

Warning
During combustion, do not
rotate the kettle.
-After extinguishing a fire, rotate the kettle. If
it were rotate during combustion, it could
cause breakdown and fire.
Do not use roduct in a lace
where materials could fall down .
-It could damage roduct or cause fire
General
rohibition
Must do
Always fixed handle, exce t the
kettle was rotated
- If you don’t fix the handle, the kettle would
rotate without notice. Therefore, handle
fixed knob always was ull back fully.
If you ut your hand into a gear box , it will be
hurt your hand. Please, kee in mind .
-Gear box, located back handle, is rolling lace which
connected rotary that it is a dangerous when you ut into
your hand,
Close
(Fixed Statue)
Handle fixed knob
Open
Must do
Handle
Do installed that the ground must be
flatted no obstacle.
- Do not install on the flammable materials or rough
ground. Do not installed & located unstable lace just like
vehicle and shi . If not, it will cause breakdown and fire
by incom lete combustion .
No touch
Check the fire and extinguish
- In using, check the normal fire through the
front anel. And after using, check the
extinguish fire and close the intermediate
valve. Close the intermediate valve when you
go out & go slee ing
General
rohibition
Must do

Do not let broth overflowed during
o eration.
-There are marks inside the kettle at a 10 interval. Its
ca acity varies from 130 to 180 .
- In case of broth, be careful not to be overflowed
because its volume increases during o eration.
Warning
Do not use roduct in a lace
where materials could fall down .
-It could damage roduct or cause fire
General
rohibition
Must do
Kee the water and sou from
entering the inside roducts.
- If the water is into control anel, exhaust duct, it
will be roblem to ignition
’
Caution for ignition.
-When you ignite re eatedly, the gas that gathered
inside combustion will ex lode it. If you not fail to
ignition, get rid of ex osure gas. (After 4~5 seconds)
-In rainy season and high humidity day and the
roducts hasn’t been used for a long time, the ignition
has a trouble to ignite.
Must do Must do
Do not install in a windy area.
- Don’t install in a windy area. It will cause the
ignition failure and damage of inside roducts
by wind such as facing a window or a door
leading to the outside.
Don’t ut materials on kettle.
- Do not leave any materials in
front of roduct while using it.
General
rohibition
Must do

Warning
On using, don’t extinguish for using
intermediate valve.
- There is a eril of fire by gas leakage with o ening not-
equi ed the safety valve
Do not using another usage
- This is an only for usage that boiled the
sou . If not, it will cause breakdown and
fire.
General
rohibition
General
rohibition
The revention is more im ortant.
-Please, confirm fasten oint state of i e connection
or something. If you are sus icious of connection
status, lease a ly the soa y water to the
intermediate valve. A ly the soa y water to the
intermediate valve to see if there is a gas leak
Don’t sto the ventilation
Must do Must do
Don’t sto the ventilation
If you sto the ventilation hole by tower, it will cause a breakdown or fire by a incom lete
combustion
In case of change user, read the user
Must do

Kettle
Gear box
Kettle knob
Inside i nition knob
Data Plate
Outside i nition knob
Handle fixed knob
Inside i nition knob
Control Panel Le
Must do
I nition check Window
Handle Knob
“Kettle knob” is ackage with instruction manual.
After assemble U er Picture, using it.

Installation
Check su ly gas ty e.
MUST DO
-You must use designat ed gas st at ed in dat a plat e on product .
This product is for low pressure.
-If your supply gas is not clear and it is not consist ent wit h st at ed gas t ype,
cont act t he purchasing agent for consult at ion.
MUST DO
Floor must be even and fixing is firm.
Fix kettle leg using 4 cs of anchor bolts(M10).
MUST DO
For inst allat ion, t here is a hole wit h it s radius 12 mm in each ket t le leg.
Bolt(M10)
Anchor
Using at t achment ,
push t he anchor t o
t he end.
Assemble the anchor
in the product t hen
fasten t he bolt .
M
t h
ake a hole on
e floor.
Put an anchor
in the hole.
Connection for gas i e
-When you connect product , it has t o be done by gas inst allat ion license acquired
WARNING
MUST DO
gas supply agent .
-Inst all int ermediat e valve
If gas pipe is rupt ured by out side physical impact , fire could t ake place or
product might be damaged due t o leakage.

Heavy pipe connect ion could cause abnormal combust ion, e plosion or
fire by leakage could appear.
If you do not fix kettle legs, roduct might be shaken when kettle is being
WARNING
rotated. That could lead food such as broth overflowed causing a burning.
Pi e connection would be under a lot of ressure so that roduct could be
damaged causing fire, or ex losion by leakage.
Page 12
When you install roduct, distance from inflammables.
-If surrounded walls are composed of inflammables, have enough space as t he followings.
Dist ance from sidewall t o product : more t han 50cm
Dist ance from rear wall t o product : more t han 60cm
Dist ance from t he ceiling t o product : more t han 150cm
Also, it is a must t o inst all noninflmmables such as e haust hood for vent ilat ion.
-If product and wall is t oo close, fire could happen. Also, if you at t ach st ainless st eel plat e, general
plat e on t he wall composed of inflammables, fire could t ake place or wall might be damaged due t o
heat t ransmission.
-When you inst all t he heat -resist ant plat e, you should have a dist ance more t han 3cm from t he heat -
resist ant plat e t o t he inflammable wall.
Material Thickness Warning
St ainless st eel plat e More t han 0.3mm
St eel plat e More t han 0.3mm
More t han 3cm from t he inflammable wall
Reinforcement is needy t o prevent deformat ion.
The inst allat ion/ product ion of heat -resist ant plat e should be implement ed according t o t he
const ruct ion of t he kit chen. And Rinnai is not responsible for t he cost .
Do not at t ach supplement s around t he product aft er inst allat ion. It could cause fire.
The distance from the floor to the ceiling must be at least more than 150cm.
MUST DO
In order t o open ket t le lid, t he space must be obt ained minimum 150cm.
Remove surrounding inflammables.
MUST DO
It might cause fire.
When you install more than 2 roducts, kee a distance of 30cm above
between roducts.
MUST DO
This is for prevent ing overheat ing and appropriat e operat ion of product s.

MUST DO
Dist ance from t he ceiling:
More than 150cm
Dist ance from t he side wall:
More than 50cm
Dist ance f rom
t he rear wall:
More than 60cm
Vent ilat ion hood
Dist ance from the heat-resist ant plat e
t o the wall: More than 3cm
Heat -resist ant plate
A dist ance from gas connect or:
More than 60cm
A dist ance from gas connect or:
More than 20cm

Install ventilation equi ments.
This product generat es some combust ion gas, t herefore vent ilat ion equipment should be adequat ely
inst alled.
Before o eration
Check supply gas t ype.
Check if t here are any inflammables
such as papers, plast ics, oil et c.
Check whet her ignit ion knob is in t he
MUST DO
ignit ion posit ion.
Keep t he ket t le’s horizont al and fi t he handle.
Com osition of ignition knob(Valve)
The burner is composed of out side burner and out side
burner.
Inside burner is connect ed t o “ Inside burner ignit ion
knob(Valve)” and out side burner is connect ed t o t wo
“ out side ignit ion knob(Valve)
The heat ing power of “ out side burner ignit ion knob(Val-
ve)” is st ronger t han t hat of “ inside burner ignit ion knob
(Valve)” and t he heat ing power of t wo “ out side burner
ignit ion knob(Valve)” is same.
1. O en intermediate valve.
Before opening valve, check whet her ignit ion knob is in
t he e t inguishment posit ion. Then open int ermediat e valve
slowly.
2. Ignition
Turn ignit ion knob t o “ ignit ion” posit ion slowly as pressing it
unt il you hear a sound of “ click” . Then you must check flames
t hrough “ ignit ion check window” .
If you t urn t he ignit ion knob wit hout pressing it , t he knob
could be broken and also if you t urn it t oo fast , ignit ion might
MUST DO
MUST DO
MUST DO
Click
Int ermediate
valve is closed.
Inside Burne r
Ignit ion Knob
Out side Burner
Ignit ion Knob
Out side Burner
Ignit ion Knob
not t ake place appropriat ely.
When you ignit e for t he first t ime, due t o t he air in t he pipe, ignit ion might not happen. Repeat
ignit ion procedure during t he first ignit ion unt il t he air comes out complet ely.

Air adjustment
The adj ust ment of air on each burner is properly set . No addit ional adj ust ment is needed.
3. Adjustment of heating ower
Heat ing power can be adj ust ed by t he
combinat ion of ignit ion and e t inguishment of
t hree knobs.
Warning
Do not place ignit ion knob bet ween ignit ion and
e t inguishment . Each ignit ion knob is not able t o
cont rol heat ing power, t herefore if you use product
leaving ignit ion knob bet ween ignit ion and e t inguish-
ment posit ion, t here might be black dirt due t o incomplet e
St rong
Heat ing
power
Medium
Heat ing
power
Weak
Heat ing
power
combust ion and product breakdown.
3. Extinguishment
Prohibit ive
MUST DO
Turn t he ignit ion knob t o t he “ e t inguishment ” posit ion.
MUST DO
Int ermediate
valve is closed
Close int ermediat e valve.

If you want to rotate kettle sou ..
First , all valve must be e t inguished.
If it rot at es while burner flame is on, product could
be damaged and fire might occur.
Second, open ket t le lid complet ely.
Be careful not t o get burned by st eam or ket t le lid.
Third, undo t he handle fi ing knob by pulling it up.
When you t urn t he handle knob t o t he left , t he ket t le
soup rot at es backward, and when you t urn t he handle
knob t o t he right , t he ket t le soup rot at es forward.
Be careful not t o get burned when product rot at es. Foods could be
Handle Knob
MUST DO
Handle fi ing knob is open.
overflowed as being shaken.
Time to take boiling 180 water
Under t he st rong heat ing power condit ion, it t akes about 65 min. t o boil 15 of 180 wat er up t o a
t emperat ure of 100 .
Maintenance
WARNING
Prohibit ive
Do not dismantle, re air or modify.
Product must not be disassembled/ repaired/ modified by anyone ot her t han
our service engineers. Ot herwise, you may be inj ured by abnormal combust ion
or malfunct ion.
Prohibit ive
Do not s ry water.
Do not spray wat er. Ot herwise, t here might be ignit ion failure or damage on
product .
Prohibit ive
Do not use any inflammable cleaning materials like thinner, benzene
etc.
If you use such inflammable subst ances like t hinner and benzene for
cleaning, fire could occur due t o ignit ion.

CAUTION
Close intermediate valve and wear gloves.
-Ot herwise, fire, elect ric shock may occur. And you could get inj uries.
Make sure there is no hardware left inside of roduct after
maintenance.
-Otherwise, roduct could break down, and there could be fire or
hysical damage.
Prohibit ive
TROUBLESHOOTING
In case t here is any problem in product , check t he followings before
calling for A/ S.
Problem Cause Act ion t o be t aken
No Ignit ion ◊There is no gas
◊Malfunct ion of ignit ion safet y device,
valve and sparker et c.
◊Open int ermediat e valve complet ely.
◊Gas check-up(in case of LPG, check up
remaining gas)
◊Call for repair
St range sound
of “ Boog-Boog”
during ignit ion
or operat ion
◊Product backfires. ◊Turn off and ignit e lat er.
◊Make product ’s horizont al.
◊If you st ill have a problem, call for
repair.
Gas leakage
◊Bad connect ion
◊Incomplet e combust ion
◊Gas leakage is suspect ed in product .
◊Close main valve t hen call for service
cent er.
Black dirt ◊Incomplet e combust ion ◊Call for repair
◊Make product ’s horizont al.
Ket t le does not
rot at e.
◊Ket t le lid is close.
◊Handle is locked
◊Gear is broken.
◊Open ket t le lid
◊Unlock handle
◊Call for repair
If ot her problems are found, call for our A/ S cent er.

SPECIFICATIONS
UNIT : mm
KETTLE SOUP PRODUCT NAME
MODEL NAME RSK-500
1,516
WIDTH
SPECIFICATIONS LENGTH 1,000
HEIGHT 955 (THE HIGHEST HEIGHT WITH OPEN: 1,490)
114Kg (PACKING: 138 Kg)
WEIGHT
3/ 4” (20A)
CONNECTION OF GAS HOSE
SAFTY DEVICE FIRE EXTINGUISH SAFTY DEVICE
2.25 Kg/ h
LARGE BURBNER
0.92 Kg/ h
LP GAS
GAS SMALL BURNER
3.17 Kg/ h
TOTAL CONSUMPTION
27,000 Kcal/ h
LARGE BURBNER
LNP GAS 27,000 Kcal/ h 12,000 Kcal/ h
SMALL BURNER
39,000 Kcal/ h
TOTAL CONSUMPTION
180 ( MAXIMUM CAPACITY : 240 )
KETTLE AVAILABLE CAPACITY
PART LISTS USER’ S GUIDE BOOK(1EA), KETTLE LID(2EA)
IT COULD BE CHANGE FOR THE BETTER PRODUCTS WITHOUT NOTICE
Table of contents
Popular Kettle manuals by other brands

Hamilton Beach
Hamilton Beach Electric Kettle Instuctions

Daewoo
Daewoo SDA1577 user manual

Brita
Brita Acclario Instructions for use

TZS First AUSTRIA
TZS First AUSTRIA Road Star FA-5425-2 Series instruction manual

Scarlett
Scarlett SC-EK21S86 instruction manual

Morphy Richards
Morphy Richards Stainless steel kettle instructions