MAIN FEATURES
The RWX73M is a 2-way supervised transmitter that
combines the Magnetic/Door Contact (against opening doors
and windows) with an additional universal input or shutter.
The RWX73M operates with RISCO’s 2-way wireless
systems.
NORMALLY CLOSED
INPUT CONFIGURATION NORMALLY OPEN INPUT
CONFIGURATION
Step 2: Input Wiring
Use the following diagrams for appropriate input
termination wiring. For DEOL termination connect
two 10 K Ohm resistors (supplied) illustrated as follows:
ALARM
DETECTOR
ALARM
DETECTOR
INSTALLATION
ƔCommunication: Bi-directional
ƔRange: up to 300 m (1,000 ft.) range line of sight
ƔSupervision: Up to 255 minutes
ƔSelective input termination : NO, NC, DEOL, shutter
ƔSelective input response: 10 / 500 ms
ƔTamper protection: back + cover
Step 1: Transmitter-to-Receiver Communication Setup
The RWX73M must identify itself to the system's receiver
by writing its coded message into the receiver's address
memory.
This registration is performed either by entering the
RWX73M’s 11-digit serial code number or by performing
the following RF allocation steps:
1. Remove the front cover (Fig 1)
2. Set the main unit to Learn mode.
3. Remove the battery from the insulation material and
reinsert it into the transmitter, paying attention to the
polarity (Fig. 2).
4. Send a write message by pressing the front tamper
switch (without detaching the back bracket) for at least
3 seconds until panel recognition is displayed (Fig. 2).
NOTE: Wait at least 1 minute before closing the front cover.
DOUBLE END OF LINE INPUT CONFIGURATION
10k
ALARM TAMPER
10k
DETECTOR
Step 3: Selecting the Mounting Location
1. Select a location best suited for communication quality
and near the intended wired detector. It is recommended
to place the unit at the highest possible position.
2. Temporarily attach the unit to this point using two-sided
adhesive tape.
3. Generate an alarm signal (by momentarily opening or
closing the input terminals) and verify that the receiver
has received the signal. If the alarm signal is not
detected, reposition the transmitter and try again.
Step 4: Mounting (Fig. 3 -- Fig. 6)
1. Detach the back of the transmitter from the back bracket
(Fig. 3A). At mounting location note the alignment marks
for both components (Fig. 3B), and then install accordingly
2. Detach magnet casing (Fig. 4A) and install with mounting
Notes:
3. The mark on the magnet's case must be aligned with
the mark on the transmitter's case (Fig. 5).
4. For installations on wood or alloy, the maximum distance
for normal operation is 10 mm (1 cm), while for metal
ferromagnetic materials (such as iron) it is 5 mm (Fig. 5).
TAMPER SW1
LED BATTERY
ANTENNA
+-
C RISCO
IN2
T.B
Step 5: De¿ning Parameters
The following parameters can be de¿ned for RWX73M:
Parameter Option
Supervision Yes/No
LED Enable Yes/No
Magnet Enable/Disable
Alarm Hold On/Off
Termination IN2: NO/NC/DEOL/Shutter
TECHNICAL SPECIFICATIONS
ELECTRICAL
Battery Type: CR123 3V Lithium Battery
Current Consumption: 11A standby
Frequency: RWX73M86800B 868.65 MHz
RWX73M43300B 433.92 MHz
Dead Time (HOLD ON): 2.5 minutes
Supervision Transmission: 0-255 minutes
Modulation Type: ASK
Battery Life: 3 years typical
Contact Size: 32 x 35 x 72 mm (1.3 x 1.4 x 2.8 in.)
Magnet Size: 16 x 11 x 72 mm (0.6 x 0.44 x 2.8 in.)
ENVIRONMENTAL
RF immunity: According to EN 50130-4
Operating temperature: -10° C to 55° C (14° F to 131° F)
Storage temperature: -20° C to 60° C (-4° F to 140° F)
Speci¿cations are subject to change without prior notice.
Should any questions arise please contact your supplier.
LED INDICATION
ƔUpon successful learning: short Àash sequence
ƔNormal operation: brief light upon transmission
ƔLow battery: short Àash sequence during transmission
EN 50131-2-6 Grade 2 Environmental Class II
2-Way Wireless
Magnetic Door/Window Contact
with Shutter
(Model RWX73M)
© RISCO Group 10/2014 5IN2255 B
Response 10 ms / 500 ms
The RWX73M reports events from IN2 and from the magnetic
the input or magnet are triggered. When restored, it transmits
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and af¿liates ("Seller") warrants its
products to be free from defects in materials and workmanship under
normal use for 24 months from the date of production. Because Seller
does not install or connect the product and because the product may
be used in conjunction with products not manufactured by the Seller,
Seller cannot guarantee the performance of the security system
which uses this product. Seller's obligation and liability under this
warranty is expressly limited to repairing and replacing, at Seller's
option, within a reasonable time after the date of delivery, any product
not meeting the speci¿cations. Seller makes no other warranty,
expressed or implied, and makes no warranty of merchantability or of
¿tness for any particular purpose. In no case shall seller be liable for
any consequential or incidental damages for breach of this or any
other warranty, expressed or implied, or upon any other basis of
liability whatsoever.
Seller'sobligationunderthiswarrantyshallnotincludeanytransporta-
tion charges or costs of installation or any liability for direct, indirect,
or consequential damages or delay. Seller does not represent that its
product may not be compromised or circumvented; that the product
will prevent any personal injury or property loss by burglary, robbery,
¿re or otherwise; or that the product will in all cases provide adequate
warning or protection.
Seller, in no event shall be liable for any direct or indirect damages or
any other losses occurred due to any type of tampering, whether
intentional or unintentional such as masking, painting or spraying on
the lenses, mirrors or any other part of the detector.
Buyer understands that a properly installed and maintained alarm
may only reduce the risk of burglary, robbery or ¿re without warning,
but is not insurance or a guaranty that such event will not occur or that
there will be no personal injury or property loss as a result thereof.
Consequently seller shall have no liability for any personal injury,
property damage or loss based on a claim that the product fails to
give warning. However, if seller is held liable, whether directly or
indirectly, for any loss or damage arising under this limited warranty
or otherwise, regardless of cause or origin, seller's maximum liability
shall not exceed the purchase price of the product, which shall be
complete and exclusive remedy against seller.
No employee or representative of Seller is authorized to change this
warranty in any way or grant any other warranty.
WARNING: This product should be tested at least once a week.
CAUTION: risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteriess according to local regulations.
Hahoma 14, Rishon Lezion, ISRAEL
Contacting RISCO Group
UK
Tel: +44-(0)-161-655-5500
E-mail: [email protected]
ITALY
Tel: +39-02-66590054
E-mail: [email protected]
SPAIN
Tel: +34-91-490-2133
E-mail: [email protected]
FRANCE
Tel: +33-164-73-28-50
E-mail: [email protected]
BELGIUM
Tel: +32-2522-7622
E-mail: [email protected]
U.S.A
Tel: +1-631-719-4400
E-mail: [email protected]
BRAZIL
Tel: +55-11-3661-8767
E-mail: [email protected]
CHINA
(Hu) Tel: +86-21-52390066
E-mail: [email protected]
CHINA
(SZ) Tel: +86-755-82789285
E-mail: [email protected]
POLAND
Tel: +48-22-500-28-40
E-mail: [email protected]
ISRAEL
Tel: +972-3-963-7777
E-mail: [email protected]
GENERAL DESCRIPTION
English
Max.
1cm
Figure 1
AUSTRALIA
Tel: +1800-991-542
E-mail: [email protected]
T
Shutter pulse 01 - 16*
B
A
Figure 3
A
Back bracket Back side of
transmitter
B
Figure 2
T
C
Figure 4 Figure 5
using 2 mounting screws and back tamper screw (Fig 3C).
2. Spacers are purchased separately (see table above).
*If de¿ned
OPERATION MODE
A
Spacer Part No. Description
RAX73XS0000A Transmitter spacers x 10, white (5 x 4mm + 5 x 2mm)
RAX73XSB000A Transmitter spacers x 10, brown (5 x 4mm + 5 x 2mm)
RAX73MS0000A Magnet spacers x 10, white (5 x 4mm + 5 x 2mm)
RAX73MSB000A Magnet spacers x 10, brown (5 x 4mm + 5 x 2mm)
1. It’s best to mount the transmitter on the non-moving part
(door/window frame), and the magnet on the moving part.
B
reed switch. In normal operation mode, an alarm is sent when
a restoral message.
screws (Fig 4B).
3. Optionally, mount spacer(s) for transmitter and/or magnet
as required (Fig. 6), positioned between the back bracket
and the mounting surface.
Figure 6
Magnet spacers (10-piece sets): Transmitter spacers (10-piece sets):
p/n: RAX73MS0000A (white)
p/n: RAX73MSB000A (brown) p/n: RAX73XS0000A (white)
p/n: RAX73XSB000A (brown)
5 X 4mm
5 X 2mm
5 X 4mm
5 X 2mm
[Optional] [Optional]
© RISCO Group 10/2014
5IN2255 B
SW1
LED PILE
ANTENNE
+-
C RISCO
IN2
T.B
DESCRIPTION GENERALE PRINCIPALES CARACTERISTIQUES
Etape 2: Câblage de Entrées
Utilisez les schémas ci-dessous pour le câblage
de terminaison d'entrée approprié. Pour la
terminaison DEOL, veuillez connecter deux résis-
tances 10K ohms (fournies) comme illustré ci-dessous:
INSTALLATION
Etape 1: Etablissement de la communication
Transmetteur/ Récepteur
Le transmetteur RWX73M doit s'identi¿er auprès du
récepteur du système en inscrivant ses messages codés
dans le registre d'adresses du récepteur.
Cet enregistrement se fera soit en entrant le numéro de
série à 11 chiffres du RWX73M ou en au moyen des
étapes suivantes par allocation RF:
1. Retirez le couvercle frontal comme l'indique le
schéma en ¿g.1
2. Réglez le récepteur en mode écriture (suivez pour
cela les instructions correspondantes).
3. Retirez la pile de sa protection isolante et insérez-la
dans le transmetteur en respectant la polarité
indiquée (cf. ¿g. 2).
4. Envoyez un message d'écriture en appuyant sur le
ressort d'autoprotection avant (sans détacher le support
de ¿xation arrière) pendant au moins 3 secondes, jusqu'à
ce que la centrale con¿rme la reconnaissance (Fig. 2).
NORMALLY OPEN INPUT
CONFIGURATION
ALARM
DETECTOR
NORMALLY CLOSED
INPUT CONFIGURATION
ALARM
DETECTOR
DOUBLE END OF LINE
INPUT CONFIGURATION
10k
ALARM TAMPER
10k
DETECTOR
SPECIFICATIONS TECHNIQUES
ELECTRIQUES
Type de Pile: Pile Lithium 3V CR123
Consommation électrique: 11ȝA au repos, 40 mA max.
Fréquence: RWX73M86800B 868.65 MHz
RWX73M43300B 433.92 MHz
Temps mort (Attente): 2.5 minutes
Supervision Transmission: 0-255 minutes
Type de Modulation: ASK
Durée de vie de la pile: 3 ans (selon usage)
Taille Contact: 32 x 35 x 72 mm
Taille Aimant: 16 X 11 X 72 mm
ENVIRONMENTALES
Immunité RF: Conforme à EN50130-4
Température de fonctionnement: -10°C--55°C
Température de stockage: -20°C--60°C
Ces spéci¿cations sont susceptibles d'être modi¿ées sans
avis préalable.
Pour tout renseignement, veuillez contacter votre revendeur.
Hahoma 14, Rishon Lezion, ISRAEL
Contacter RISCO Group
Grande-Bretagne
Tel: +44-(0)-161-655-5500
E-mail: [email protected]
Italie Tel: +39-02-66590054
E-mail: [email protected]
Espagne Tel: +34-91-490-2133
E-mail: [email protected]
France Tel: +33-164-73-28-50
E-mail: [email protected]
Belgique Tel: +32-2522-7622
E-mail: [email protected] Etas-Unis Tel: +1-631-719-4400
E-mail: [email protected]
Brésil Tel: +55-11-3661-8767
E-mail: [email protected]
Chine (Hu) Tel: +86-21-52390066
E-mail: [email protected]
Chine (SZ) Tel: +86-755-82789285
E-mail: [email protected]
Pologne
Tel: +48-22-500-28-40
E-mail: [email protected]
Israël
Tel: +972-3-963-7777
E-mail: [email protected]
Etape 3: Choix de l'emplacement de l'installation
1. Choisissez l'emplacement le mieux adapté pour assurer
la qualité de la communication, tout en restant au plus
près du détecteur ¿laire prévu. Risco recommande de
placer l’unité en position la plus haute possible.
2. Fixez provisoirement l'appareil à ce point à l'aide d'un
ruban adhésif double face.
3. Générez un signal d'alarme (en ouvrant ou en fermant
momentanément les bornes d'entrée) et véri¿ez que le
récepteur a bien reçu le signal. Si le signal d'alarme
n'est pas détecté, replacez le transmetteur et essayez
à nouveau.
Notes:
1. Il est préférable de monter le transmetteur sur une partie qui ne
bouge pas (cadre de fenêtre/porte), et l'aimant sur la partie qui
bouge.
2. Les entretoises sont commandées séparément (voir tableau).
3. La marque du boîtier de l'aimant doit être alignée à la marque
du boîtier du transmetteur.
4. Pour les installations sur bois, la distance maximum est de
10mm (1cm), et sur matériaux en métal (comme le fer), elle est
de 5mm (Fig.5).
Etape 5: Dé¿nition des paramètres
Les paramètres suivants peuvent être dé¿nis pour le
RWX73M:
Paramètres Option
Supervision Oui/Non
LED validée Oui/Non
Magnétique Activé/Désactivé
Alarme Mémorisée On/Off
Terminaison IN2: NO/NC/DEOL, Obturateur
Réponse 10ms/500ms
Le RWX73M est un transmetteur bidirectionnel
supervisé combinant un contact magnétique de
portes/fenêtres et une entrée additionnelle ou obturateur.
Le RWX73M fonctionne avec les récepteurs sans
¿l bidirectionnels du Groupe RISCO.
ƔCommunication: Bidirectionnelle
ƔPortée de fonctionnement jusqu'à 300 m
(1000 ft) (en extérieur)
ƔSupervision: jusqu’à 255 minutes
ƔTerminaison de zone sélective: NO, NC, DEOL, obturateur
ƔTemps de réponse de zone sélectif: 10/500ms
ƔProtection anti-sabotage: Arrière + Couvercle
Contact Magnétique
Porte/Fenêtre (Obturateur)
sans-¿l bidirectionnel
(Model RWX73M)
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and af¿liates ("Seller") warrants its
products to be free from defects in materials and workmanship under
normal use for 24 months from the date of production. Because Seller
does not install or connect the product and because the product may
be used in conjunction with products not manufactured by the Seller,
Seller cannot guarantee the performance of the security system which
uses this product. Seller's obligation and liability under this warranty is
expressly limited to repairing and replacing, at Seller's option, within a
reasonable time after the date of delivery, any product not meeting the
speci¿cations. Seller makes no other warranty, expressed or implied,
and makes no warranty of merchantability or of ¿tness for any
particular purpose. In no case shall seller be liable for any consequen-
tial or incidental damages for breach of this or any other warranty,
expressed or implied, or upon any other basis of liability whatsoever.
Seller's obligation under this warranty shall not include any transporta-
tion charges or costs of installation or any liability for direct, indirect, or
consequential damages or delay. Seller does not represent that its
product may not be compromised or circumvented; that the product
will prevent any personal injury or property loss by burglary, robbery,
¿re or otherwise; or that the product will in all cases provide adequate
warning or protection.
Seller, in no event shall be liable for any direct or indirect damages or
any other losses occurred due to any type of tampering, whether
intentional or unintentional such as masking, painting or spraying on
the lenses, mirrors or any other part of the detector.
Buyer understands that a properly installed and maintained alarm may
only reduce the risk of burglary, robbery or ¿re without warning, but is
not insurance or a guaranty that such event will not occur or that there
will be no personal injury or property loss as a result thereof.
Consequently seller shall have no liability for any personal injury,
property damage or loss based on a claim that the product fails to give
warning. However, if seller is held liable, whether directly or indirectly,
for any loss or damage arising under this limited warranty or
otherwise, regardless of cause or origin, seller's maximum liability
shall not exceed the purchase price of the product, which shall be
complete and exclusive remedy against seller.
No employee or representative of Seller is authorized to change this
warranty in any way or grant any other warranty.
WARNING: This product should be tested at least once a week.
CAUTION: risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteriess according to local regulations.
Mode Opérationnel
Le RWX73M rapporte les événements de l’entrée IN2 et de l’interrupteur magnétique (ILS). En mode normal de
fonctionnement l'alarme est envoyée lorsque l’entrée ou l’aimant sont déclenchés. Lors d'une restauration, il transmet un
message de rétablissement.
Français
Max.
1cm
Fig. 1
T
B
A
Fig.3
A
Support de Fixation Partie arrière du
transmetteur
B
Fig. 2
T
C
Fig. 4 Fig.5
AB
Fig. 6
Entretoises aimant (par 10) : Entretoises transmetteur (par 10) :
Réf: RAX73MS0000A (blanc)
Réf: RAX73MSB000A (marron) Réf: RAX73XS0000A (blanc)
Réf: RAX73XSB000A (marron)
5 X 4mm
5 X 2mm
5 X 4mm
5 X 2mm
[En option] [En option]
NOTE: Attendez au moins 1 minute avant de fermer le
couvercle frontal. Impulsion obturateur 01--16*
*Si dé¿ni
AustralieTel: +1800-991-542
E-mail: [email protected]
Etape 4: Montage (Fig. 3 - Fig. 6)
1. Détachez la partie arrière du transmetteur du support de
¿xation (Fig. 3A). A l'emplacement de ¿xation, notez
l'alignement des marques des 2 parties (Fig. 3B) et ¿xez
en utilisant 2 vis de ¿xation, et une vis pour
l'autoprotection (Fig. 3C).
2.Ouvrez l'aimant (Fig. 4A) et installez-le avec des vis
de ¿xation (Fig. 4B).
La tolérance de measure est de +/- 20%
Ouverture Fermeture Ouverture Fermeture
Bois Fer doux
X 50mm 44mm 23mm 21mm
Y 85mm 75mm 55mm 45mm
Z 27mm 25mm 23mm 18mm
Y
Contact Almant
Z
X
Batterie Basse 2.6V
3.En option, montez les entretoises du transmetteur et/ou de
l'aimant si nécessaire (Fig. 6), positionnés entre le support
de ¿xation et la surface de montage.
INDICATEUR LED
ƔLors de la réussite de l'apprentissage: séquence de
clignotement courte
ƔFonctionnement normal: bref allumage lors de la
transmission
ƔPile faible: clignotement court lors de la transmission
Déclaration de conformité
Par la présente, RISCO Group déclare que le détecteur RWX73M
a été conçue conformément aux normes:
RTC 50131-2-6, EN50131-2-6 Grade 2 Class II,
Environmental Class II ,IP31 IK 04
Organisme de certi¿cation
AFNOR CERTIFICATION: 11 rue Francis de Pressensé
93571 LA PLAINE SAINT-DENIS Cedex, http://www.marque-nf.com
CNPP Cert: BP 2265, 27950 ST MARCEL, http://www.cnpp.com
certi¿cate number: 2122000013B0
Déclaration de Conformité RTTE
Par la présente, RISCO Group déclare que cet accessoire est en
conformité avec les conditions essentielles et à d’autres dispositions
appropriées de la directive 1999/5/EC. Pour obtenir la copie complète
de conformité, référez-vous à notre site web : www.riscogroup.com
Ce produit répond aux exigences du référentiel de certi¿cation
NF324-H58 pour la classi¿cation 2 boucliers, et de la
RTC 50131-2-6.

Other manuals for RWX73M

3

Other Risco Accessories manuals

Risco RWX73M User manual

Risco

Risco RWX73M User manual

Risco iWISE 815DTG3 User manual

Risco

Risco iWISE 815DTG3 User manual

Risco WL X312 User manual

Risco

Risco WL X312 User manual

Risco watchout 312PR User manual

Risco

Risco watchout 312PR User manual

Risco WL T312 User manual

Risco

Risco WL T312 User manual

Risco RWT74 Programming manual

Risco

Risco RWT74 Programming manual

Risco RWX73F User manual

Risco

Risco RWX73F User manual

Risco iWISE QUAD AM Grade 3 User manual

Risco

Risco iWISE QUAD AM Grade 3 User manual

Popular Accessories manuals by other brands

Orion 6001 instruction manual

Orion

Orion 6001 instruction manual

VIEWEG 504250 operating manual

VIEWEG

VIEWEG 504250 operating manual

Exped MegaMat Duo 10 instructions

Exped

Exped MegaMat Duo 10 instructions

iOptron SmartStarMiniTower instruction manual

iOptron

iOptron SmartStarMiniTower instruction manual

Panasonic EQ-34 instruction manual

Panasonic

Panasonic EQ-34 instruction manual

ABB Ability installation guide

ABB

ABB Ability installation guide

Radiant SA7005 owner's manual

Radiant

Radiant SA7005 owner's manual

EUTECH INSTRUMENTS ECFP21A1A1 DIFFERENTIAL PH SENSOR - REV instruction manual

EUTECH INSTRUMENTS

EUTECH INSTRUMENTS ECFP21A1A1 DIFFERENTIAL PH SENSOR - REV instruction manual

Way Elio Use and maintenance manual

Way

Way Elio Use and maintenance manual

EVERSPRING ST815 manual

EVERSPRING

EVERSPRING ST815 manual

Lenoxx PR4423 user manual

Lenoxx

Lenoxx PR4423 user manual

Gilead 7120-70 instruction manual

Gilead

Gilead 7120-70 instruction manual

YOKOGAWA DO71 manual

YOKOGAWA

YOKOGAWA DO71 manual

LEGRAND 0 942 78 manual

LEGRAND

LEGRAND 0 942 78 manual

Teledyne UFO-130 manual 

Teledyne

Teledyne UFO-130 manual 

ROSE DISPLAYS ANOQUICK ROUND WITH MULTICLIPS instruction sheet

ROSE DISPLAYS

ROSE DISPLAYS ANOQUICK ROUND WITH MULTICLIPS instruction sheet

Panasonic WX-LA20 Using

Panasonic

Panasonic WX-LA20 Using

Futek USB200 Series troubleshooting guide

Futek

Futek USB200 Series troubleshooting guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.