MSIP-CRM-RSN-FT400
Thank you for purchasing the FT400 remote control
FT400 is a remote control for automatic door by using 2.4GHz frequency.
Please read this manual carefully for the safe and accurate use of this product.
is product.
1 . Product compositions and specifications
2 . How to use
You can select one of the following two methods to register a transmitter / receiver (pairing).
3 . Registering the FT400 with R24 receiver
Ø2.3 x 8 Round head Screw
Battery 1.5V Size AAA
FT400 remote control (Transmitter) FT400
User manual
Power supply
Transmitting frequency 1.5V *1 (Size AAA Battery)
2.4GHz
Transmitting distance
Power consumption Up to10m (When installed in steel structures : Up to 2m )
100mA under
Operating temp -20℃~ 50℃
1 EA
1 EA
1 EA
1 EA
Dimensions 36 x 79 x 16 (mm)
FT400 (Transmitter)
FM type remote control
You can use “Hold open” and “Lock” Function. Please refer to below.
Dip Switch
Button A :
Open
Button C :
Lock
Button B :
Hold open
Button D :
Unlock
※ When Locked, only works with FT400 until it is unlocked.
※ In case of power failure when locked, lock condition will be kept.
※ If you press the lock button while the door is hold open mode, the door will be closed and locked.
Components Specifications
Dip Switch
②Method 2: Registration using push buttons
1. How to register
- Connect the power to the R24 receiver.
- Press the button A on FT400 while pressing the registerⅠ
button on R24 receiver.
2. How to delete
- Connect power to the R24 receiver.
- Press the button B on FT400 while pressing the delete
button on R24 receiver.
- The green LED will flash and deletion will be completed.
- The red LED will flash and registration will be completed.
3. How to delete all
- Press the register
button and delete
button on R24 receiver for 5 seconds at the same time.
- The green LED will flash three times when all registered transmitters have been deleted.
Dip Switch
※
Registration using push buttons should be done when the dip switches
of both FT400 and R24 are in OFF position.
※ Up to 10 FT400 transmitters can be registered with one R24 receiver using this method.
LED
In case of using Lock Function.
Automatic door controller
Connector
Yellow ⅹ 2 (Output contact)
White x 2 (Input contact)
Power (AC/DC12V~24V) Gray ⅹ 2
Register Button
Delete Button DIP switch for channel setting
Connection
Point
①Method 1: Registration using dip switches
※ Pairing cannot be done if all DIP switches of both FT400 and R24 are in OFF position.
※ An unlimited number of FT400 transmitters can be registered with one R24 receiver.
Set the dip switches in the same sequence while power is not connected.