2 3
EN EN
ENEN
DC12V OR 24V TO AC220V~240V INSTRUCTION MANUAL TROUBLESHOOTING
USEFUL APPLICATIONS
RUN NOTEBOOK COMPUTERS, RADIOS, TVs, VCRs,
LAMPS, FANS, FAX, DRILL, . . . . . . ETC.
SPECIFICATION
INPUT VOLTAGE RANGE : DC 10~15V (12V) // DC 20~30V (24V)
INPUT FULL LOAD CURRENT : 60A (12V) // 30A (24V)
NORMAL STANDBY INPUT CURRENT : <0.6A (12V) // <0.4A (24V)
EuP MODE STANDBY INPUT CURRENT : 0.03A~0.15A
EuP MODE AC OUTPUT : DETECTING AC OUTPUT EVERY 4 SECOND
USB PORT : OUTPUT 5VDC (500mA MAX.)
OUTPUT VOLTAGE (AC) : 230V
OUTPUT WAVEFORM : MODIFY SINEWAVE
OUTPUT FREQUENCY : 50Hz or 60Hz
CONTINUE OUTPUT POWER : 600W
PEAK OUTPUT POWER : 1500W
EFFICIENCY : 85~90%
BATTERY LOW PRE-ALARM : 10.5 ± 0.5V (12V) // 21 ± 0.5V (24V)
BATTERY LOW SHUTDOWN : 10 ± 0.5V (12V) // 20 ± 0.5V (24V)
THERMAL PROTECT : 60 ± 5oC (MICROCONTROLLER )
OVERLOAD PROTECT : YES (MICROCONTROLLER )
OUTPUT SHORT PROTECT : YES ( MICROCONTROLLER )
BATTERY EX. 12V / 24V PROTECT : YES ( MICROCONTROLLER )
BATTERY POLARITY PROTECT : YES (BY FUSE )
FUSE : 25A*3PCS (12V) // 15A*3PCS (24V)
DIMENSION ( L*W*H) mm : 190*113*62
WEIGHT : 1500g
IF THE INVERTER DOES NOT APPEAR TO BE FUNCTIONING PROPERLY, THERE ARE SEVERAL REASONS WHY
THE INVERTER MAY NOT BE RESPONDING.
1) POOR CONTACT
*CLEAN CONTACT PARTS THOROUGHLY
2) RECEPTACLE HAS NO POWER
*CHECK CAR FUSE, REPLACE DAMAGED FUSE
*CHECK RECEPTACLE WIRING. REPAIR IF NECESSARY
3) FUSE IS BLOWN
*THE FUSE IS LOCATED INSIDE THE P.C.B. REPLACE FUSE WITH A FUSE OF EQUIVALENT VALUE
4) OVERLOAD CAUSED AC OUTPUT TO REDUCE
*REDUCE THE WATTAGE OF YOUR LOAD TO LOWER THAN 600 WATTS
5) THERMAL CAUSED AC OUTPUT TO REDUCE
*UNDER HEAVY LOADS FOR EXTENDED PERIODS. THE AC INVERTER WILL REDUCE OUTPUT TO
PREVENT DAMAGE TO EXCESS HEAT. IF THIS HAPPENS, PLEASE PROCEED AS BELOW:
(A) SWITCH OFF THE POWER SWITCH OF THIS INVERTER
(B) DECREASE LOAD OF THIS MACHINE I. E. DISCONNECT SOME OF THE APPLIANCES OR WAIT UNTIL
THIS INVERTER BECOME COOL.
(C) SWITCH ON THE POWER SWITCH OF THIS INVERTER.
6) LOW-BATTERY SHUTDOWN
*RECHARGE YOUR BATTERY AND RESUME OPERATION.
Please read the user manual before use.
CAUTION
ALWAYS PLACE THE INVERTER IN AN ENVIRONMENT WHICH IS:
(A) WELL VENTILATED
(B) NOT EXPOSED TO DIRECT SUNLIGHT OR HEAT SOURCE
(C) OUT OF REACH FROM CHILDREN
(D) AWAY FROM WATER/MOISTURE,OIL OR GREASE
(E) AWAY FROM ANY FLAMMABLE SUBSTANCE