manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ROBINHOOD
  6. •
  7. Ventilation Hood
  8. •
  9. ROBINHOOD CR Plus 600 User manual

ROBINHOOD CR Plus 600 User manual

This manual suits for next models

1

Other ROBINHOOD Ventilation Hood manuals

ROBINHOOD Brimstone 60 User manual

ROBINHOOD

ROBINHOOD Brimstone 60 User manual

ROBINHOOD RIWC9PLUS User manual

ROBINHOOD

ROBINHOOD RIWC9PLUS User manual

ROBINHOOD Rangehood User manual

ROBINHOOD

ROBINHOOD Rangehood User manual

ROBINHOOD RPD3CL6BK User manual

ROBINHOOD

ROBINHOOD RPD3CL6BK User manual

ROBINHOOD RTA3CI6WH User manual

ROBINHOOD

ROBINHOOD RTA3CI6WH User manual

ROBINHOOD RHCI9SS - IMPRESA User manual

ROBINHOOD

ROBINHOOD RHCI9SS - IMPRESA User manual

ROBINHOOD RWH3CH6SS User manual

ROBINHOOD

ROBINHOOD RWH3CH6SS User manual

ROBINHOOD Argus 90 User manual

ROBINHOOD

ROBINHOOD Argus 90 User manual

ROBINHOOD RCT600SS User manual

ROBINHOOD

ROBINHOOD RCT600SS User manual

ROBINHOOD RWC60XCOM User manual

ROBINHOOD

ROBINHOOD RWC60XCOM User manual

ROBINHOOD RO Series User manual

ROBINHOOD

ROBINHOOD RO Series User manual

ROBINHOOD RICDW9 User manual

ROBINHOOD

ROBINHOOD RICDW9 User manual

ROBINHOOD RWK3CL6G User manual

ROBINHOOD

ROBINHOOD RWK3CL6G User manual

ROBINHOOD RHCP9G User manual

ROBINHOOD

ROBINHOOD RHCP9G User manual

ROBINHOOD RWD3CL6SSDC User manual

ROBINHOOD

ROBINHOOD RWD3CL6SSDC User manual

ROBINHOOD RWE3CL6SS User manual

ROBINHOOD

ROBINHOOD RWE3CL6SS User manual

ROBINHOOD RCB2AH6WH User manual

ROBINHOOD

ROBINHOOD RCB2AH6WH User manual

ROBINHOOD RWA3CL9SS User manual

ROBINHOOD

ROBINHOOD RWA3CL9SS User manual

ROBINHOOD RIIC9G User manual

ROBINHOOD

ROBINHOOD RIIC9G User manual

ROBINHOOD RCR1201 User manual

ROBINHOOD

ROBINHOOD RCR1201 User manual

ROBINHOOD RWC3CH6SS User manual

ROBINHOOD

ROBINHOOD RWC3CH6SS User manual

ROBINHOOD RWD3CL75DXDC User manual

ROBINHOOD

ROBINHOOD RWD3CL75DXDC User manual

ROBINHOOD RIWC9PLUS Service manual

ROBINHOOD

ROBINHOOD RIWC9PLUS Service manual

ROBINHOOD RSOF60XCOM User manual

ROBINHOOD

ROBINHOOD RSOF60XCOM User manual

Popular Ventilation Hood manuals by other brands

Haier CXW-219-D67 null

Haier

Haier CXW-219-D67 null

emmeti RECUPA MED A-140 Installation and use manual

emmeti

emmeti RECUPA MED A-140 Installation and use manual

Nibe F135 user manual

Nibe

Nibe F135 user manual

Zephyr Spruce AK9834BS Use, care and installation guide

Zephyr

Zephyr Spruce AK9834BS Use, care and installation guide

Kuppersberg INTRO 60 Technical Passport

Kuppersberg

Kuppersberg INTRO 60 Technical Passport

Hisense MH6INBG manual

Hisense

Hisense MH6INBG manual

Miele DA 1255 Operating and installation instructions

Miele

Miele DA 1255 Operating and installation instructions

Broan 46000 Specification sheet

Broan

Broan 46000 Specification sheet

GE Profile PV977 Owner's Manual & Installation Instructions

GE

GE Profile PV977 Owner's Manual & Installation Instructions

FALMEC FFRIA24W5FS Instruction booklet

FALMEC

FALMEC FFRIA24W5FS Instruction booklet

Whirlpool RH2600XL-1 SERIES installation instructions

Whirlpool

Whirlpool RH2600XL-1 SERIES installation instructions

ETNA AV360RVS Instructions for use

ETNA

ETNA AV360RVS Instructions for use

JUNO JDF603E6 installation manual

JUNO

JUNO JDF603E6 installation manual

Miele DA 6708 D Operating and installation instructions

Miele

Miele DA 6708 D Operating and installation instructions

Tricity Bendix LE 150 Installation & operating instructions

Tricity Bendix

Tricity Bendix LE 150 Installation & operating instructions

AEG X68163BV1 user manual

AEG

AEG X68163BV1 user manual

AEG 125 D operating instructions

AEG

AEG 125 D operating instructions

Smeg KSEV97X instruction manual

Smeg

Smeg KSEV97X instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

104598 Issue F
ECN: 06 180
INSTALLATION INSTRUCTION
CANOPY RANGEHOOD
All dimensions are in millimeters
PRODUCT DIMENSIONS
225
Min 555
Max 885
170
500
597 (600 Model)
897 (900 Model)
1216 (1201 Model)
230-250
Note: Generic model is shown.
Actual product may differ.
CANOPY OPERATION
INSTALLATION OF UNIT
Thank you for purchasing a quality stainless steel canopy rangehood. We have a
high standard of quality control and each rangehood is tested and approved before
it leaves the factory.
IMPORTANT: Please read prior to installation or operation
•
Always switch power off prior to installing, servicing or cleaning the appliance.
•
Never use the appliance without filters.
• Please read the notes on general cleaning, especially the filters.
• Exhaust air must not be discharged into a heating flue or wall cavity, unless the
cavity is designed for that purpose.
• Areas where the rangehood is installed that also have gas, oil or coal fired
heaters, must be well ventilated to prevent a partial vacuum in the room. This
includes gas hobs. (A partial vacuum in the room could result in too high a
concentration of gas in the atmosphere).
• The appliance is supplied with an approved power cable which must not be
changed. If the supply cord of this equipment is damaged, it must only be
replaced by the manufacturer or its service agent or similarly qualified person in
order to avoid hazard.
The unit is designed for 2.4 to 2.7 metre high ceiling. The decorative chimney cover
is telescopic and is designed for 550 to 850mm adjustment.
Note: Ducting accessories are not supplied. Please refer to the optional ducting kits.
The air outlet from the motor requires 150mm round ducting which requires 160mm
diameter round hole in the ceiling. This hole will be covered by the decorative
chimney. Care should be taken to align canopy with decorative chimney allowing
sufficient clearance to accommodate the ducting.
Before starting assembly, read the instructions carefully and remove the filters from
canopy to allow access to wall mounting holes. To remove the filters, pull the
relative catch and tilting it downwards until it disengages from the supports.
Reverse these instructions when refitting the filters.
NOTE: Stainless steel is very easily damaged during installation if abraded or knocked
by tools.
MAINTENANCE
Particular care must be taken with grease filters which must be periodically cleaned
(at least every two months). Remove the grease filters and wash them either by
hand or in the dishwasher using mild detergent. CAUTION: Never use products
containing abrasives (e.g. scouring pads, steel wool, abrasive liquid cleaner etc.)
Use lukewarm water and mild detergent to clean stainless steel components. In high
humidity and coastal environments, cleaning should be carried out frequently.
Care and attention should always be taken when cooking with oils, alcohol, etc;
which give off flammable vapours.
Pre-used oil is especially dangerous in this respect. Do not use uncovered electrical
grill.
To avoid possible risks of fire always comply with the maintenance instruction below.
ATTENTION: This appliance must be earthed
When making the electrical connection, check that the socket has an earth
connection and that the voltage values correspond to those indicated on the rating
plate inside the appliance. The power socket connection is to be easily accessible
after installation.
CONTROL PANEL
Left Push Button (01) = Fan On/Off Speed 1
Second Push Button (2) = Fan Speed 2
Third Push Button (3) = Fan Speed 3
Fourth Push Button (T) = Fan/Light Timer - 5 Mins
Fifth Push Button (L) = Light On/Off
PLEASE READ THE ENTIRE INSTRUCTION BEFORE INSTALLING THE CANOPY
01 2 3 T L
104598 Issue F
ECN: 06 180
SCREW
CUP-WASHER
DECORATIVE
SCREW COVER
(4 PLACES)
8
7
9
9
9
INSTALLATION OF THE UNIT
WARNING: The distance between the hob and the mounting holes of the canopy
must be at least 880mm for 600&900 model and 900mm for 1201 model to ensure
that the fully installed canopy has the recommended clearance of 700mm between
the lower part of the hood and the cooking hob. Before drilling any holes check the
wall and ceiling are clear of any electrical cables, pipes etc. Fixing to a solid stud is
recommended.
Fix the mounting washers in position shown in diagrams. 1 Check with a spirit level
across the washers to ensure they are level.
INSTALLING DUCTING
NOTE: All ducting must comply with local requirements and building codes.
Mark the position of decorative cover at ceiling and wall, cut cornice moulding away
if necessary to enable panels to fit flat against the wall and ceiling. 2 Mark and cut
the hole in the ceiling to fit the ducting (155-160mm dia). 3 This is positioned
centrally with the canopy and 80mm from the wall.
INSTALLING CEILING BRACKET
Using the supplied screws, fix the ceiling bracket 4 to the wall, checking that it is
aligned with the hood.
CUT SCOTIA
TO CLEAR COVER IF PREFERRED
160mm
DIA HOLE
FIX TO SOLID
FRAMING
CEILING
BRACKET
FIX SAFETY
SCREWS (FOUR)
AFTER MOUNTING
KEYHOLES
IN REAR OF
CANOPY
(SHOWN DOTTED)
3
2
1
4
5
6
34
RECIRCULATING
OPTION
DUCTING
OPTION
200 mm
for
1201
Model
1
700mm
UNDERSIDE OF HOOD
TO COOKING SURFACE
1
2.4 TO 2.7 METRE HIGH CEILING TOP
GUIDE
RECIRCULATING
DUCTING
(600/900) 260mm
(1201) 340mm
880mm (600/900)
900mm (1201)
170 mm
for
600&900
Model
FOR SERVICE OR ADVICE CONTACT:
WARNING
•This appliance is not intended for use by young children or infirm
persons without supervision.
•Young children should be supervised to ensure that they do not play
with the appliance.
•There shall be adequate ventilation of the room when the rangehood is
used at the same time as appliances burning gas or other fuels.
•You must read the details concerning the method and frequency of cleaning.
•There is a fire risk if cleaning is not carried out in accordance with the
instructions.
•Do not flambé under the rangehood.
•Exhaust air must not be discharged into an existing flue which is used
for exhausting fumes from appliances burning gas or other fuels.
• The minimum distance between the hob surface and the lowest part of
the rangehood is 600mm. This distance shall be at least 650mm if the
rangehood is installed over a gas hob. (We recommend 700mm).
•Attention should be given to ensure that any applicable regulations
concerning the discharge of exhaust air is fulfilled.
•If the supply cord of this equipment is damaged, it must only be
replaced by the manufacturer or its service agent or similarl qualified
person in order to avoid a hazard.
RECOMMENDED UNIDUCT DUCTING
SYSTEMS FOR RANGEHOODS
MANUFACTURED IN NEW ZEALAND BY:
ROBINHOOD LIMITED
P.O. BOX 51 201, PAKURANGA,AUCKLAND, N.Z.
TEL: +64 9 272 5129 • FAX: +64 9 272 5148
ISO9001 Certified
in Thailand
Verasu Limited Partnership
Tel (662) 254 8100, Fax (662) 253 1574
in Singapore
Multico Building Products Pte Ltd
Tel 65 283 8888, Fax 65 283 8138
in Australia
Robinhood Australia Pty Ltd A.C.N. 104298062
Tel 1800 648 556, Fax 1800 628 577, Email [email protected]
in New Zealand
Robinhood Ltd
Tel 0800 760 667, Fax 0800 276 246, Email [email protected]
FINAL ASSEMBLY
Remove proctective plastic covering from all parts
including filters. Now fit the canopy on the fixed
mounting washers. 5 Plug in power cord to power
supply. Check function of rangehood lights and
motor, before continuing assembly. Level the hood
and fix with safety screws 6 . Connect 150mm
ducting to top of motor flange and secure 7 .
Assemble the telescopic ducting covers 8 to
accurately suit the dimension required 9 and secure
with screws plastic cup washers and plastic caps to
the top and bottom of the chimney in 4 places.
Lamp Replacement
DUCTED
Use Manufacturer Product code: 1688
For optimal efficiency, use smooth ducting for reduced noise and increased
airflow. Flexible ducting should only be used as a last resort.
For other Accessories, Parts or Service, please contact your local supplier or
approved service agent.
INSTALLATION OPTION ACCESSORIES
FOR HALOGEN LIGHT
a) SWITCH OFF THE POWER TO THE RANGEHOOD
b) USE A SMALL BLADE SCREWDRIVER TO PRISE
OFF THE LIGHT COVER (NOTE SLOT)
c) USE A CLOTH TO REMOVE THE BULB. DO NOT TOUCH
d) REPLACE WITH A NEW BULB AND “SNAP” THE
COVER BACK IN PLACE
e) HALOGEN BULB 12Volt/20Watt BULB
RECIRCULATED
Use Manufacturer Product code:
1742 (for 600mm unit)
1743 (for 900mm unit)
1742 & 2519 (for 1216mm unit)
Extra lengths or bends may be required
depending on the length required &
whether there is any structural material
in the run, eg rafters.
CR9SSPLUS / RCR1201
Electrical Rating:
406W (1.70A)
Max. at 230-240V 50Hz
CR6SSPLUS
Electrical Rating:
387W (1.61A)
Max. at 230-240V 50Hz