ROBLON FL 2002-2B User manual

FL 2002 - 2 B
Halogen light generator
for Fibre optic lighting systems User Manual
These mounting instructions describes mounting and installation of the following products:
Item no.: 0121 0100 FL 2002-2 B Ø28 100W 230V
0121 0101 FL 2002-2 B Ø9/Ø28 75W 230V
0121 0110 FL 2002-2 B Ø28 100W 120V
0121 0111 FL 2002-2 B Ø9/Ø28 75W 120V
+99082054 21.01.2013

2
1. Introduction
This manual serves you as a guideline to how the system is operated in the safest way.
Following the recommendations in this guideline all contributes to:
·Enhanced functionality
·Extended lifetime of components
·Uninterrupted illumination
Your Roblon halogen light generator, type FL 2002-2 B is intended for indoor use in fibre optic
lighting systems using either glass and PMMA fibres. This light generator is prepared for use in
cabinets or showcases, either closed or semi closed compartments.
Contents
1. INTRODUCTION ................................................................................................................. 2
2. PRODUCT OVERVIEW AND PACKING LIST .................................................................................. 3
3. TECHNICAL INFO................................................................................................................ 3
4. INSTALLING THE LIGHT GENERATOR ....................................................................................... 4
5. FIXATING THE LIGHT GENERATOR TO THE SURFACE ................................................................... 4
6. MOUNTING OF OPTIONAL COLOUR FILTERS. ............................................................................. 5
7. TROUBLE SHOOTING ........................................................................................................... 5
8. SPARE PARTS .................................................................................................................... 7
9. ACCESSORIES .................................................................................................................... 7

3
2. Product overview and packing list
Contents of this box:
- FL 2002-2 B
- Adaptor kit Ø28 -> Ø9
(including allen key)
- User manual
3. Technical info
Light port size: Ø28 mm. Ø9 focus with the supplied adapter
Fibre type: PMMA/Glass
Supply voltage: 230-240 V / 50-60 Hz or 120 V / 60 Hz
Lamps: 75W Philips type 14515, 3000K.
100W Philips type 6839/25H. 3400K.
Power consumption: 75 W 69 VA
100 W 96 VA
Power cord: Power cord
Dimming: Leading or trailing edge.
Ballast: Electronic
Thermal protection: Yes, w/ auto reset.
Cooling system: 12 VDC axial fan (60x60mm)
Fan noise level: 29 db(A)
Ambient temperature: 0 - 40°C
Lamp type: Halogen
Lamp life time: 75W 6000 hours
100W 2500 hours
Lamp colour temp: 75W 3000K
100W 3400K
Material: Anodised aluminium.
Dimensions: (L x H x W) 195 x 85 x 70mm.
Weight: 600 g.
Safety approvals: CE
CB
cULus

4
4. Installing the Light generator
1. Mount the Ø9/Ø28 adapter on the harness common end.
2. Secure the set screw with the supplied allen key.
3. Insert the harness' common end fully into the light port on the light generator.
4. Tighten the finger screw at the light port.
5. Close the lid and tighten the finger screw.
6. Se to that the requirements of installation and ventilation are met.
7. Connect the supply cord to the main power supply.
(If you are using a Ø28 harness, please disregard 1 and 2.)
5. Fixating the light generator to the surface
1. Loosen the finger screw at the top of the light generator to open the lid.
2. Be careful not to damage the lamp. Remove it if necessary.
3. Mount the light generator with one or two screws (not included)
through the holes beside the lamp.
4. Refit the lamp and close the lid again.

6. Mounting of optional colour filters.
(not included).
1. Loosen the finger screw and open the lid.
2. Mount the Colour filter.
3. Close the lid again and secure the finger screw.
7. Trouble shooting
Symptom Cause Solution
No light
Is the power ON? Turn ON the power.
Is the power cord properly
connected? Reinsert the power cord.
Is the light generator too hot?
Check with the installation
instructions. Cool off for 10
minutes and try again.
No light, but fan is running
Is the lamp blown? Replace lamp with new one.
Light switches ON and OFF
Is the light generator too hot
while operating?
Check with installation
instructions.
Is the fan blocked? Clear the airways.
Is the fan broken?
Replace the fan with a new
one.
The light output has
diminished
Is the lamp old?
Replace the lamp with a new
one.
Are the filters dirty?
Clean the filters with a damp
cloth. Finish by wiping off
with a dry lint-free cloth.
Is the fibre harness common end
dirty?
Clean the harness common
end with a damp cloth. Finish
by wiping off with a dry lint-
free cloth.

6
When Installing one or more light generators in a closed compartment
The light generator need to breathe to keep cool.
Ventilation holes must be made in the compartment corresponding to min. 29 cm² of air
intake and min. 29 cm² of exhaust air.
When using this installation method, the air intake and exhaust of the light generator must be
separated.
Use ventilation hose adapter, +78000510, for standard Ø60 mm flexible ventilation hose, to
Guide the exhaust air out of the compartment.
When doing so, it is possible to install the light generator in very small compartments.
Mounting of ventilation hose adapter.
(not included)

7
8. Spare parts
Description Roblon item no.:
Model designation Image
Lamp
+65127595 14515 from Philips (for 75W units)
+65129905 6834/25H FO from Philips (for 100W units)
Fan
+64060122 KDE-1206PTV2 MS.A.GN from Sunon
Heat filter
+54001000
KG-2
Transformer
+68105020 HTM105 from Osram (for 100W European
units)
+68105042 LET-151R from Lightech (for US units)
9. Accessories
Description Roblon part no.: Model designation Image
Colour filter
+78000190 Colour Filter, FL 150-3/FL2002-2B, yellow
+78000191 Colour Filter, FL 150-3/FL2002-2B, green
+78000192 Colour Filter, FL 150-3/FL2002-2B, blue
+78000193 Colour Filter, FL 150-3/FL2002-2B, red
CTC filter
+78000197 CTC Filter, FL 150-3/FL2002-2 B, -500K
+78000198 CTC Filter, FL 150-3/FL2002-2 B, -1200K
+78000199 CTC Filter, FL 150-3/FL2002-2 B, -900K
Ventilation
hose adapter +78000510 For connecting light generator to Ø60 mm
flexible ventilation hose.

8
Roblon Lighting Tel: +45 9620 3300
Nordhavnsvej 1 Fax: +45 9620 3399
9900 Frederikshavn info@roblon.com
Denmark www.roblon.com
Roblon accepts no responsibility
for
possible errors in printed an
d
electronic material. Roblon reserves the right to alter or discontinue products without notice.
©2012, Roblon A/S
Table of contents
Other ROBLON Portable Generator manuals