HIGH POWERED LED
FLOOD LIGHT
RLEDF30W-24, RLEDF50W-24
RLEDF30W-24
100-240V~50/60Hz
30W
2000lm
3000K
70
85º
> 0.9
-15ºC <Ta < 40ºC
65
Class I
134mm
204mm
225mm
2.1Kg
3 years
15 - 20m
18 x 10m
2.5 - 6m
RLEDF50W-24
100-240V~50/60Hz
50W
3500lm
4500K
70
85º
> 0.9
15ºC <Ta < 40ºC
65
Class I
143mm
234mm
284mm
2.9Kg
3 years
20 - 25m
25 x 10m
4 - 8m
Model No.
Voltage:
Power:
Lumen:
CCT:
CRI:
Beam Angle:
PF:
Ta:
IP Rating:
Safety Class:
Depth:
Width:
Height:
Weight:
Warranty:
Projection Dist:
Projection Area:
Mounting Height:
Compliance with: EN55015,EN60598-1,EN61000-3-2,
EN61000-3-3,EN61347-2-13,EN61547
Issue 3 031114
PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES.
! Electrical products can cause death or injury, or damage to property. If in any doubt about the installation or
use of this product, consult a competent electrician
Note:
Product technical information and specification may change over time without prior notification
For the latest technical information please visit our web site www.ledgrouprobus.com or robusdirect.com
INSTRUCTION MANUAL
Specifications Installation
Page 1
Information for the Product user:
1. Please note the requirement to dispose of Waste Electrical & Electronic Equipment separately from household waste (WEEE marked with
crossed out wheelie bin symbol).
2. Please consider your role in contributing to re-use and recycling by returning this product at end of life to a collection centre for waste electrical
equipment or a Civic Amenity site, or to a retail outlet from which you are purchasing a replacement.
3. This equipment may contain substances that are hazardous to health and the environment if disposed of carelessly. It is important that it is
separated from normal household waste and recycled in the WEEE chain
4. The “crossed out wheelie bin symbol” on a product indicates this equipment must not be disposed of in normal household waste, but should be
disposed of according to local WEEE regulations
The Installation must be carried out by an electrician
LED Group
Western Retail Park Tel: +353 1 7099000
Nangor Road Fax: +353 1 7099060
Ireland Website: www.led.ie
ISO 9001:2008
Q UAL IT Y ASSU RE DCO MPAN Y
1. Ensure mains supply is switched off before commencing
work.
2. Select suitable location for luminaire.
3. Mark wall with appropriate fixing positions. Before
drilling, ensure that the hole does not impinge on pipe
work, cables or other building services.
4. Mount luminaire on wall.
5. The luminaire is supplied with 0.5m of rubber cable.
Using suitable IP rated enclosure terminate Brown (Live),
Blue (Neutral) and Green/Yellow (Earth) to switch
supply..
6. This product has no user serviceable parts. If any part is
damaged, disconnect from mains and discontinue use.
Note: No “fixings screws provided’, please use
appropriate fixing screws.