Rockwell Automation Allen-Bradley VersaView 6300M Series User manual

User Manual Original Instructions
VersaView 6300M Panel
Monitors
Bulletin Number 6300M

2Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021
VersaView 6300M Panel Monitors User Manual
Important User Information
Read this document and the documents listed in the additional resources section about installation, configuration, and
operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize
themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to
be carried out by suitably trained personnel in accordance with applicable code of practice.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be
impaired.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use
or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and
requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for
actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software
described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is
prohibited.
Throughout this manual, when necessary, we use notes to make you aware of safety considerations.
These labels may also be on or inside the equipment to provide specific precautions.
The following icon may appear in the text of this document.
WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment,
which may lead to personal injury or death, property damage, or economic loss.
ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property
damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence.
IMPORTANT Identifies information that is critical for successful application and understanding of the product.
SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous
voltage may be present.
BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may
reach dangerous temperatures.
ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to
potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL
Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).
Identifies information that is useful and can help to make a process easier to do or easier to understand.

Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021 3
Table of Contents
Preface
Catalog Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Additional Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Chapter 1
About the Monitor Monitor Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Monitor Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Monitor Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Chapter 2
Install the Monitor Unpack the Monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Prepare for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Environment and Enclosure Information . . . . . . . . . . . . . . . . . . . . . . 14
UL/cUL Mark Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
European Union Directive Compliance . . . . . . . . . . . . . . . . . . . . . . . . 15
Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Restricted Access Locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Hazardous Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Environnements dangereux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Panel Monitor Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Panel Mounting Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Prepare the Panel Cutout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Required Tools for Panel Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Panel Mounting the Monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Connect Peripheral Cables to the Monitor . . . . . . . . . . . . . . . . . . . . . . . . . 19
Grounding and Bonding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
DC Power Supply Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Install the Ground Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Connect DC-powered Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Connect AC-powered Monitors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Connect the Monitor to a Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Video Input Status and On Screen Display (OSD) Buttons . . . . . . . 24
Touch Screen Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Chapter 3
Configure the Display Set the Monitor Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Check and Change the Display Resolution . . . . . . . . . . . . . . . . . . . . . . . . . 25
Touch Screen Precaution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Calibrate the Touch Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Light-emitting Diode and Button Descriptions . . . . . . . . . . . . . . . . . . . . 28
OSD Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

4Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021
Table of Contents
Chapter 4
Clean the Monitor Clean the Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Clean Monitor Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Clean All Vent Holes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Remove Paint and Grease from Bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Chapter 5
Troubleshoot the Monitor Ship or Transport the Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Dispose of the Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021 5
Preface
This manual is a user guide for VersaView® 6300M panel monitors. It provides
procedures to the following:
• Install the monitor.
• Make monitor connections.
• Operate the monitor.
• Troubleshoot the monitor.
A general knowledge of automation technology is needed to understand and
follow the instructions in this publication.
Knowledge of monitors, personal computers, and Microsoft Windows®
operating systems are required to understand and follow the instructions in
this publication.
Catalog Numbers This publication is applicable to these 6300M panel monitors. For your catalog
number, see the product label on your monitor.
Additional Resources These documents contain additional information about related products from
Rockwell Automation.
You can view or download publications at rok.auto/literature.
Cat. No. Identifier Bezel Material Touch Screen
Type Aspect Ratio
6300M-xxxAAPS…
Aluminum Resistive
16:9
6300M-xxxCAPS…
6300M-xxxBAPS… 4:3
6300M-xxxDAPS…
6300M-xxxBBPS… Aluminum True Flat Resistive 4:3
6300M-xxxDBPS…
6300M-xxxAXPS…
Stainless Steel True Flat Resistive
16:9
6300M-xxxCXPS…
6300M-xxxBSPS… 4:3
6300M-xxxDSPS…
6300M-xxxACPS… Aluminum glass True Flat PCAP 16:9
6300M-xxxCCPS…
Resource Description
VersaView 6300M Panel Monitors Installation
Instructions, publication 6300M-IN001 Provides basic installation guidelines and instructions for
VersaView 6300M panel monitors.
VersaView 6300M Panel Monitors for Hazardous
Locations Installation Instructions, publication
6300M-IN002
Provides basic installation guidelines and instructions for
VersaView 6300M panel monitors for hazardous locations.
VersaView 6300 Industrial Computer and Monitor
Specifications Technical Data, publication IC-TD003 Provides technical specifications about the VersaView 6300M
industrial panel monitors.
Industrial Automation Wiring and Grounding Guidelines,
publication 1770-4.1 Provides general guidelines for installing a Rockwell
Automation industrial system.
Safety Guidelines for the Application, Installation, and
Maintenance of Solid-State Controls. publication SGI-1.1 Provides general guidelines for the application, installation,
and maintenance of solid-state control.
Product Certifications website,
rok.auto/certifications Provides declarations of conformity, certificates, and other
certification details.

6Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021
Notes:

Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021 7
Chapter 1
About the Monitor
The Allen-Bradley® VersaView® 6300M panel monitor family is available in
various display sizes and resolutions. There are options of either standard or
low profile bezel units.
IP65 (model dependent) environmental protection makes the VersaView
6300M panel monitor an excellent match for wash-down applications such as
food processing and life sciences.
Some VersaView 6300M panel monitors have long distance capabilities, which
means they can be connected to a personal computer where both are up to
100 m (328 ft) apart.
VersaView 6300M panel monitors offer the following features:
• Available in standard and low profile bezels, with the latter available in
aluminum, aluminum glass True Flat, and stainless steel True Flat
• Available in standard and widescreen formats
• Analog resistive or projected capacitive (PCAP) touch screens, the latter
for multi-touch operation
• Available in display sizes between 8.4…24 inches
•Resolutionsthatinclude FHD/VGA/SVGA/SXGA/XGA
• Wide angle LCD viewing with light-emitting diode (LED) backlight
technology
• Standard panel monitors offer the following:
- Two video ports, DVI-D and DisplayPort
- One USB HUB, Type B port, and up to three USB 2.0, Type A ports(1)
• Long distance panel monitors offer the following:
- One remote video link (RVL) port
- Up to five USB 2.0 ports(1)
• 110/240V AC input power standard, 24V DC optional
• IP65 rating on monitors with aluminum, aluminum True Flat, and
aluminum glass True Flat bezels
• IP66K and IP69K (model dependent) ratings on monitors with stainless
steel True Flat bezels
For more information about your computer model, see Monitor Options on
page 8.
(1) Only certain models offer a USB 2.0 port on the front bezel; see page 8.
Standard Profile, Stainless Steel Bezel
Low Profile, Aluminum Bezel
Low Profile, Aluminum-glass True Flat Bezel

8Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021
Chapter 1 About the Monitor
Monitor Options The following monitors are covered in this user manual. See the label on your
monitor for its catalog number.
Cat. No. Display Size
(In.) Touch Screen
Type Aspect
Ratio Resolution
(W x H) Luminance,
cd/m2Bezel Type USB Port
on Front Bezel? Long Distance
Model?
6300M-xxxBAPS…
8.4 Resistive 4:3 800x600, SVGA 400
Aluminum
Yes
No
6300M-xxxDAPS… Yes
6300M-xxxBBPS… Aluminum True Flat No
6300M-xxxDBPS… Yes
6300M-xxxAAPS…
10.1
Resistive
16:9 1280x800, WXGA 400
Aluminum
No
No
6300M-xxxCAPS… Yes
6300M-xxxAXPS… Stainless Steel True Flat(1) No
6300M-xxxCXPS… Yes
6300M-xxxACPS… PCAP Aluminum Glass True Flat No
6300M-xxxCCPS… Yes
6300M-xxxBAPS…
10.4 Resistive 4:3 800x600, SVGA 400
Aluminum
Yes
No
6300M-xxxDAPS… Yes
6300M-xxxBBPS… Aluminum True Flat No
6300M-xxxDBPS… Yes
6300M-xxxBAPS…
12.1
Resistive
4:3 1024x768, XGA 600
Aluminum
Yes
No
6300M-xxxDAPS… Yes
6300M-xxxBBPS… Aluminum True Flat No
6300M-xxxDBPS… Yes
6300M-xxxBSPS… Stainless Steel True Flat(2) No No
6300M-xxxDSPS… Yes
6300M-xxxAAPS…
16:9 1280x800, WXGA 400
Aluminum
No
No
6300M-xxxCAPS… Yes
6300M-xxxAXPS… Stainless Steel True Flat(2) No
6300M-xxxCXPS… Yes
6300M-xxxACPS… PCAP Aluminum Glass True Flat No
6300M-xxxCCPS… Yes
6300M-xxxBAPS…
15.0 Resistive 4:3 1024x768, XGA 500
Aluminum
Yes
No
6300M-xxxDAPS… Yes
6300M-xxxBBPS… Aluminum True Flat No
6300M-xxxDBPS… Yes
6300M-xxxBSPS… Stainless Steel True Flat(2) No No
6300M-xxxDSPS… Yes
6300M-xxxAAPS…
15.6
Resistive
16:9 1920x1080, FHD 400
Aluminum
No
No
6300M-xxxCAPS… Yes
6300M-xxxAXPS… Stainless Steel True Flat(2) No
6300M-xxxCXPS… Yes
6300M-xxxACPS… PCAP Aluminum Glass True Flat No
6300M-xxxCCPS… Yes
6300M-xxxBAPS…
17.0 Resistive 4:3 1280x1024, SXGA 350
Aluminum
Yes
No
6300M-xxxDAPS… Yes
6300M-xxxBBPS… Aluminum True Flat No
6300M-xxxDBPS… Yes
6300M-xxxBSPS… Stainless Steel True Flat(2) No No
6300M-xxxDSPS… Yes
Table continues on the next page.

Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021 9
Chapter 1 About the Monitor
6300M-xxxAAPS…
18.5
Resistive
16:9 1920x1080, FHD
400
Aluminum
No
No
6300M-xxxCAPS… Yes
6300M-xxxAXPS… Stainless Steel True Flat(2) No
6300M-xxxCXPS… Yes
6300M-xxxACPS… PCAP 500 Aluminum Glass True Flat No
6300M-xxxCCPS… Yes
6300M-xxxBAPS…
19.0 Resistive 4:3 1280x1024, SXGA 300
Aluminum
Yes
No
6300M-xxxDAPS… Yes
6300M-xxxBBPS… Aluminum True Flat No
6300M-xxxDBPS… Yes
6300M-xxxBSPS… Stainless Steel True Flat(2) No No
6300M-xxxDSPS… Yes
6300M-xxxAAPS…
21.5
Resistive
16:9 1920x1080, FHD 300
Aluminum
No
No
6300M-xxxCAPS… Yes
6300M-xxxAXPS… Stainless Steel True Flat(2) No
6300M-xxxCXPS… Yes
6300M-xxxACPS… PCAP Aluminum Glass True Flat No
6300M-xxxCCPS… Yes
6300M-xxxAAPS…
24.0
Resistive
16:9 1920x1080, FHD 300
Aluminum
No
No
6300M-xxxCAPS… Yes
6300M-xxxAXPS… Stainless Steel True Flat(2) No
6300M-xxxCXPS… Yes
6300M-xxxACPS… PCAP Aluminum Glass True Flat No
6300M-xxxCCPS… Yes
(1) IP69K rating.
(2) IP66K rating.
Cat. No. Display Size
(In.) Touch Screen
Type Aspect
Ratio Resolution
(W x H) Luminance,
cd/m2Bezel Type USB Port
on Front Bezel? Long Distance
Model?

10 Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021
Chapter 1 About the Monitor
Monitor Connections The next two figures show the hardware features and peripheral connections
of VersaView 6300M monitors.
Figure 1 - VersaView 6300M Monitor Hardware Features
1 2 3
5
7
6
DC Power Models AC Power Models(1)
8
Bottom of Standard Panel Monitor Chassis
1 2 3
5
7
6
4
DC Power Models AC Power Models(1)
Bottom of Long Distance Panel Monitor Chassis
4
No. Description No. Description
1 AC power switch 5 Ground (earth) screw
2 Fuse box 6 Video status LED
3 AC power cord inlet 7 OSD control buttons
4 DC two-pole connector 8 Remote video link LEDs

Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021 11
Chapter 1 About the Monitor
Figure 2 - Peripheral Connections for VersaView 6300M Standard Monitors
Figure 3 - Peripheral Connections for VersaView 6300M Long Distance Monitors
No. Description No. Description
1 DisplayPort 4 3 x USB 2.0, Type A ports
2 DVI-D port 5 USB 2.0, Type A port(1)
(1) Only available on certain models; see page 8. The USB port cover must be closed properly for IP65 protection.
IMPORTANT: USB ports on front bezels of 6300M-xxxBA and 6300M-xxxBB monitors are not for use in hazardous
locations.
3 USB HUB port, Type B
No. Description No. Description
1RVL(1)
(1) Remote video link. Requires specific Ethernet cables; see Table 4 on page 20.
3USB 2.0, Type A port(2)
(2) Optional feature.
2 3 x USB 2.0, Type A ports 4 USB 2.0, Type A port(3)
(3) Only available on certain models; see page 8. The USB port cover must be closed properly for IP65 protection.
IMPORTANT: USB ports on front bezels of 6300M-xxxBA and 6300M-xxxBB monitors are not for use in hazardous
locations.
Bottom of a Panel Monitor Chassis
1234
5
Front of Monitor
Bottom of a Panel Monitor Chassis
12
3
4
Front of Monitor

12 Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021
Chapter 1 About the Monitor
Monitor Dimensions The following figure shows the dimensions of the various VersaView 6300M
monitors.
Figure 4 - VersaView 6300M Panel Monitor Dimensions
NOTE: Panel cutout is
not to scale and does
not represent any
aspect ratio.
J
CD
G
F
E
B
A
Panel Cutout
4:3 and 5:4 Display Ratio Monitor
16:9 and 16:10 Display Ratio Monitor
DC
E
B
A
Display
Size
(In.) Bezel Type Aspect
Ratio
All dimensions are in mm (In.)
Panel Monitors Panel Cutout
A B C D E F G
8.4 Aluminum 4:3 250
(9.84) 210
(8.27) 45
(1.77) 19
(0.75) 5
(0.2) 230
(9.06) 190
(7.48)
Aluminum True Flat
10.1
Aluminum
16:10
262.5
(10.33) 181
(7.13) 45
(1.77) 17.5
(0.69) 4.5
(0.18) 255.5
(10.06) 174
(6.85)
Stainless steel 278.3
(10.96) 196.7
(7.74) 45
(1.77) 17.5
(0.69) 6 (0.24) 255.5
(10.06) 174
(6.85)
Aluminum glass True Flat 262.5
(10.33) 181
(7.13) 45
(1.77) 17.5
(0.69) 4.5
(0.18) 255.5
(10.06) 174
(6.85)
Stainless steel 278.3
(10.96) 196.7
(7.74) 45
(1.77) 17.5
(0.69) 6 (0.24) 255.5
(10.06) 174
(6.85)
10.4 Aluminum 4:3 300
(11.81) 245
(9.65) 45
(1.77) 19
(0.75) 5 (0.2) 280
(11.02) 225
(8.86)
Aluminum True Flat
12.1
Aluminum
16:10
308
(12.13) 210
(8.27) 45
(1.77) 17.5
(0.69) 4.5
(0.18) 301
(11.85) 203
(7.99)
Aluminum glass True Flat 308
(12.13) 210
(8.27) 45
(1.77) 17.5
(0.69) 4.5
(0.18) 301
(11.85) 203
(7.99)
Aluminum
4:3
335
(13.19) 270
(10.63) 45
(1.77) 19
(0.75) 5 (0.2) 315
(12.4) 250
(9.84)
Stainless steel 335
(13.19) 270
(10.63) 45
(1.77) 19
(0.75) 5 (0.2) 315
(12.4) 250
(9.84)
15.0
Aluminum
4:3
390
(15.35) 315
(12.4) 45
(1.77) 19 (0.75) 6 (0.24) 370
(14.57) 295
(11.61)
Stainless steel 398
(15.67) 315
(12.4) 45
(1.77) 19 (0.75) 6 (0.24) 370
(14.57) 295
(11.61)
15.6
Aluminum
16:9
395
(15.55) 245
(9.65) 45
(1.77) 25
(0.98) (1)
(1) 4.5 mm (0.18 in.) for aluminum bezels, 6 mm (0.24 in.) for aluminum glass True Flat bezels.
388
(15.28) 238
(9.37)
Aluminum glass True Flat 395
(15.55) 245
(9.65) 45
(1.77) 25
(0.98) (1) 388
(15.28) 238
(9.37)
17.0
Aluminum
5:4
455
(17.91) 355
(13.98) 45
(1.77) 21
(0.83) 6 (0.24) 435
(17.13) 335
(13.19)
Stainless steel 455
(17.91) 355
(13.98) 45
(1.77) 21
(0.83) 6 (0.24) 435
(17.13) 335
(13.19)
18.5
Aluminum
16:9
461
(18.15) 282
(11.1) 45
(1.77) 25
(0.98) 6 (0.24) 453
(17.83) 274
(10.79)
Aluminum glass True Flat 461
(18.15) 282
(11.1) 45
(1.77) 25
(0.98) 6 (0.24) 453
(17.83) 274
(10.79)
19.0
Aluminum
5:4
490
(19.29) 388
(15.28) 45
(1.77) 21
(0.83) 6 (0.24) 470
(18.5) 368
(14.49)
Stainless steel 490
(19.29) 388
(15.28) 45
(1.77) 21
(0.83) 6 (0.24) 470
(18.5) 368
(14.49)
21.5
Aluminum
16:9
528
(20.79) 319
(12.56) 45
(1.77) 25
(0.98) 6 (0.24) 520
(20.47) 312
(12.28)
Aluminum glass True Flat 528
(20.79) 319
(12.56) 45
(1.77) 25
(0.98) 6 (0.24) 520
(20.47) 312
(12.28)
24.0
Aluminum
16:9
584
(23) 352
(13.86) 45
(1.77) 25
(0.98) 6 (0.24) 577
(22.72) 344
(13.54)
Aluminum glass True Flat 584
(23) 352
(13.86) 45
(1.77) 25
(0.98) 6 (0.24) 577
(22.72) 344
(13.54)

Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021 13
Chapter 2
Install the Monitor
Follow these guidelines and procedures to help you plan your installation,
prepare the panel cutout, and mount and power up the monitor.
Unpack the Monitor Before you unpack the monitor, inspect the shipping carton for damage. If
damage is visible, immediately contact the shipper and request assistance.
Otherwise, proceed with unpacking.
Keep the original packing material in case you must return the monitor for
repair or transport it to another location.
The monitors ship with the following items.
Table 1 - Parts List
Item Description
Hardware • Mounting clips (for panel mounting)
• DC power connector assembly kit (DC-powered models)
Document
• For non-hazardous applications:
VersaView® 6300M Industrial Panel Monitors Installation Instructions, publication 6300M-IN001
• For hazardous locations:
VersaView 6300M Panel Monitors for Hazardous Locations Installation Instructions, publication
6300M-IN002

14 Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021
Chapter 2 Install the Monitor
Prepare for Installation Read and follow these precautions before you install the monitor.
Environment and Enclosure Information
UL/cUL Mark Compliance
This equipment is not suitable for use in locations where children are likely to
be present.
Cet équipement ne convient pas à une utilisation dans des lieux pouvant
accueillir des enfants.
For 6300M Panel Monitors in Non-hazardous Locations
Equipment with the UL/cUL mark complies with the requirements of UL
61010-1, UL 61010-2-201, CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201.
A copy of the certificate of compliance is available at rok.auto/certifications.
For 6300M Panel Monitors in Hazardous Locations
Equipment with the UL/cUL mark complies with the requirements of UL
61010-1, UL 61010-2-201, UL 121201, CSA C22.2 No. 213, CSA C22.2 No. 61010-1,
and CSA C22.2 No. 61010-2-201. A copy of the certificate of compliance is
available at rok.auto/certifications.
ATTENTION: This equipment is intended for use in a Pollution Degree 2
industrial environment, in overvoltage Category II applications (as defined in IEC
60664-1), at altitudes up to 2000 m (6561 ft) without derating.
This equipment is considered Group 1, Class A industrial equipment according to
EN 61326-1. Without appropriate precautions, there can be potential difficulties
with electromagnetic compatibility in other environments due to conducted as
well as radiated disturbance.
This equipment is considered open equipment.
•For non-hazardous locations: The equipment must be mounted in an
enclosure where it can be operated from the front panel. The enclosure in which
this equipment is installed must be accessed only with a key or tool, and only by
trained and authorized personnel.
•For hazardous locations: To meet some regulatory requirements, the
equipment must be mounted in an enclosure that is suitably designed for
environmental conditions that can be present and appropriately designed to
help prevent personal injury resulting from accessibility to live parts. This
equipment is an open-type device and is meant to be installed in an enclosure
suitable for the environment such that the equipment is only accessible with the
use of a tool.
• In addition to this publication, see the following:
• Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for
more installation requirements
• UL 50, UL 50E, CSA C22.2, No 94.1, and CSA C22.2, No. 94.2, as applicable, for
explanations of the degrees of protection provided by enclosures

Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021 15
Chapter 2 Install the Monitor
European Union Directive Compliance
The VersaView 6300M panel monitors for non-hazardous locations meet the
European Union Directive requirements when installed within the European
Union or EEA regions and have the CE marking. A copy of the declaration of
the conformity is available at rok.auto/certifications.
Connect peripheral cables to the appropriate I/O ports on the monitor. To
comply with EN 61326-1, see Connect Peripheral Cables to the Monitor on
page 19 for the required cable types.
Installation Guidelines Follow these guidelines to make sure that your monitor provides service with
excellent reliability.
• When choosing the installation site, consider the following:
- The site must have sufficient power
- The site must be indoors and non-hazardous, except where the
monitor is rated for hazardous locations; see Hazardous Locations on
page 16
- The site must not expose the monitor to direct sunlight
- The material for panel mounting must meet the criteria that are
described in Prepare the Panel Cutout on page 18
• The monitors can operate in a surrounding air temperature range of
0…50 °C (32…122 °F).
The surrounding air temperature must not exceed the maximum
temperature for your monitor, especially when the monitor is mounted
in an enclosure.
• The monitors can be stored in a surrounding air temperature range of
-5…+60 °C (23…140 °F).
• The relative humidity of the ambient air must be 20…90%
noncondensing at 0…40 °C (32…104 °F), and 20…80% noncondensing at
41…50 °C (105…122 °F).
IMPORTANT VersaView 6300M panel monitors for hazardous locations are intended only
for USA and Canada applications.
ATTENTION: This monitor is intended to operate in an industrial or control room
environment, which uses some form of power isolation from the public
low-voltage mains. Some monitor configurations cannot comply with the
EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of
the European Union. Obtain permission from the local power authority before you
connect any monitor configuration that draws more than 75 W of AC power
directly from the public mains.
All I/O cables must be used only indoors.
IMPORTANT The monitor can operate at a range of extremes. However, the life
span of any electronic device is shortened if you continuously
operate the monitor at its highest rated temperature, which
includes the touch screen and LCD panel.

16 Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021
Chapter 2 Install the Monitor
Restricted Access Locations
Verify that restricted access locations meet these conditions for the VersaView
6300M panel monitors for hazardous locations:
• Access is gained only by service personnel or by users who have been
instructed on the reasons for restrictions to a location and about any
precautions to be taken.
• Access is by using a tool, a lock and key, or other means of security
controlled by the authority responsible for the location.
Hazardous Locations VersaView 6300M panel monitors for hazardous locations are suitable for use
in Class I, Division 2 Groups A, B, C, D hazardous locations, or only in
non-hazardous locations, with a temperature code of T5.
The following statement applies to use in hazardous locations.
Environnements dangereux
La mise en garde suivante s’applique à une utilisation en environnement
dangereux.
WARNING: Explosion Hazard
• Substitution of any components can impair suitability for hazardous locations.
• This equipment is an open-type device and is meant to be installed in an enclosure suitable for the environment such that the
equipment is only accessible with the use of a tool.
• Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations.
• Peripheral equipment must be suitable for the location where it is used.
• The front USB port on VersaView 6300M-xxxBA and 6300M-xxxBB monitors is not for use in hazardous locations. Only use that
front USB port for installation and maintenance purposes.
• In the U.S., all wiring must be in accordance with Class I, Division 2 wiring methods of Article 501 of the National Electrical Code,
and in accordance with the authority having jurisdiction.
• In Canada, all wiring must be in accordance with Section 18-1J2 of the Canadian Electrical Code, and in accordance with the
authority having jurisdiction.
ATTENTION: The following section is a French translation of the above Hazardous
Locations section to comply with certification agency requirements.
AVERTISSEMENT : Risque d'explosion
• La substitution de composants peut rendre cet équipement impropre à une utilisation enenvironnement dangereux.
• Cet équipement est de type ouvert et conçu pour être installé dans un boîtier adapté à l'environnement, de sorte que seul un
outil peut être utilisé pour avoir accès à l'équipement.
• Ne débranchez pas l'équipement pendant qu'il est sous tension, sauf si l'environnement est connu pour être dépourvu de
concentrations inflammables.
• L’équipement périphérique doit être adapté à l’environnement dans lequel il est utilisé.
• Le port USB à l'avant des moniteurs VersaView 6300M-xxxBA et 6300M-xxxBB n'est pas destiné à être utilisé dans des lieux
dangereux. Il ne sert qu'à des fins d'installation et de maintenance.
• Ne pas connecter ou déconnecter des composants sans s’être assuré que l’alimentation est coupée.
• L’ensemble du câblage doit être conforme à la réglementation en vigueur dans le pays où cet équipement est installé.
• Tout équipement utilisé en environnement dangereux doit être monté dans une armoire fournissant une protection adaptée aux
conditions d'utilisation ambiantes et suffisante pour éviter toute blessure corporelle pouvant résulter d'un contact direct avec
des composants sous tension.

Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021 17
Chapter 2 Install the Monitor
Panel Monitor Mounting For VersaView 6300M monitors that can be panel mounted, perform the
following steps.
Panel Mounting Requirements
Follow these requirements to mount the VersaView 6300M panel monitor.
• Choose a suitable mounting height.
• To help prevent overheating and to provide access to the I/O ports for
cable connections, mount the monitor so there are the following
minimum clearances:
- X and Z directions: 7 cm (2.75 in.)
- Y direction: 10 cm (3.94 in.)
• For optimal performance, mount the monitor in the horizontal
orientation and vertical (upright) position, so the I/O ports face down.
Enclosure Requirements
• The enclosure must provide sufficient space around air inlets and outlets
to provide the circulation necessary for cooling. For further information,
see Panel Mounting Requirements on this page. Never allow air passages
to become obstructed.
• Hot air rises. The temperature at the top of the enclosure is often higher
than the temperature in other parts of the enclosure, especially if air is
not circulating.
Consider a user-supplied fan, heat exchanger, or air conditioner for heat
generated by other devices in the enclosure. See Installation Guidelines
on page 15 for the acceptable temperature ranges for these monitors.
IMPORTANT For 6300M panel monitors in non-hazardous locations:
The vertical position can be tilted up to 20° forward or 20° backward
from the upright position. However, this acceptable tilt angle range
decreases the maximum operating air temperature to 45 °C (113 °F).
For 6300M panel monitors in hazardous locations:
The vertical position must always be in the upright position; there is
no acceptable tilt angle.
Y
Y
XX Z
Horizontal Orientation
(I/O Ports Face Down)
Vertical
(Upright)
Position
0°
(preferred)
20°
max
20°
max
IMPORTANT: This acceptable tilt
angle range applies only to 6300M
panel monitors in
non-hazardous locations.
6300M panel monitors for
hazardous locations cannot be
tilted.

18 Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021
Chapter 2 Install the Monitor
Prepare the Panel Cutout
Observe these guidelines to install the VersaView 6300M monitor in a panel.
• Plan the panel cutout according to the following:
- The acceptable horizontal orientation and vertical position; see Panel
Mounting Requirements on page 17.
- The panel cutout dimensions needed for your monitor that are found
on page 12.
• The mounting panel material must be 2…6 mm (0.08…0.24 in.) thick.
• For a uniform gasket seal, the roughness of the panel surface must not
exceed 120 microns (Rz 120).
• Confirm that there is adequate space behind the panel as needed. For
specific information, see Panel Mounting Requirements on page 17.
• Verify that the area around the panel is clear of obstructions.
• Remove all electrical power from the panel before you make the cutout.
Required Tools for Panel Installation
These tools are required for panel monitor installation:
• Panel cutout tools (for panel mounting)
• Torque limiting screwdriver with a 1.5 mm hex key bit
• Supplied mounting clips; for the needed quantity, see Figure 5 on page 19
• Safety glasses
Panel Mounting the Monitor
Perform the following steps to install the monitor in the panel cutout.
1. Remove all electrical power from the panel before you make the cutout.
2. Cut an opening in the panel area to the dimensions needed for your
monitor that are found on page 12.
3. After the cutout is completed, clean the panel area of all debris and metal
fragments.
4. Make sure that the sealing gasket is positioned properly on the monitor.
5. From the front of the panel, insert the monitor into the cutout.
ATTENTION: Failure to follow these guidelines can result in personal injury or
damage to the panel components.
Take precautions so any metal fragments during the panel cutout do not enter
components that are installed already in the panel.
À l’attention des: Lorsqu'un panneau est découpé, des morceaux de métal
peuvent être produits.
Vous devez prendre les mesures de sécurité nécessaires pour prévenir la
pénétration des morceaux dans les composants déjà installés dans le panneau.
IMPORTANT You need two people to install the monitor; one person to hold the monitor in
place while another person installs the mounting clips.
IMPORTANT All monitors have a gasket that forms a compression-type seal.
Therefore, do not use sealing compounds.

Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021 19
Chapter 2 Install the Monitor
6. Slide the mounting clips into the holes on
all four sides of the monitor as shown at
right. For the various hole locations, see
Figure 5.
7. Hand-tighten the mounting clips
according to the tighten sequence in
Figure 5.
8. With the torque limiting screwdriver and 1.5 mm hex key bit, tighten the
mounting clips to a torque of 0.2 N•m (1.8 lb•in) by the tighten sequence
in Figure 5.
9. Repeat this process at least three times until the clips are properly
torqued to 0.2 N•m (1.8 lb•in).
Verify that the gasket is compressed uniformly against the panel.
Figure 5 - Tighten and Torque Sequence for the Mounting Clips
Connect Peripheral Cables
to the Monitor
Connect peripheral cables to the appropriate I/O ports on a VersaView 6300M
monitor. To comply with EN 61326-1, use the following for cable types. All I/O
cables must be used only indoors, and USB cables must be less than 3 m
(9.84 ft) long.
ATTENTION: Tighten the mounting clips to the specified torque to provide
a proper seal and to help prevent product damage. Rockwell Automation
assumes no responsibility for water or chemical damage to the monitor or
other equipment within the enclosure because of improper installation.
I/O Ports
18
72
4
5
6
3
All Bezels Except
Stainless Steel
8.4…15 and 17 in. Display Sizes
I/O Ports
10 1
62
3
8
7
4
9
5
All Bezels Except
Stainless Steel
15.6 and 19 in. Display Sizes
I/O Ports
All Bezels Except Stainless Steel
21.5 and 24 in. Display Sizes
10 1
62
3
814
4
9
57
12
13
11
I/O Ports
All Bezels Except Stainless Steel
18.5 in. Display Size
10 1
62
84
9
5
7
12
3
11
18
72
4
5
6
3
Stainless Steel Bezel
(IP66 rating)
12.1 in. Display Size
I/O Ports
I/O Ports
Stainless Steel Bezel
(IP69K rating)
10.1 in. Display Size
10 1
62
3
814
4
9
57
12
13
11
I/O Ports
10 1
62
3
8
7
4
9
5
Stainless Steel Bezel
(IP66 rating)
15, 17, and 19 in. Display Sizes
1
23
74
8
Table 2 - Peripheral Connections for Standard Monitors
Item
No. Cable
Type Required
Attribute Item
No. Cable
Type Required
Attribute
1DisplayPort
Shielded
5USB2.0
(1)
(1) Optional feature.
Shielded
2DVI-D 6USB2.0
(2)
(2) Only certain models offer a USB 2.0 port on the front bezel.
IMPORTANT: USB ports on front bezels of 6300M-xxxBA and 6300M-xxxBB monitors are not
for use in hazardous locations.
3 USB HUB 7 DC power Unshielded
4 3 x USB 2.0 8 AC power
5
6

20 Rockwell Automation Publication 6300M-UM001A-EN-P - December 2021
Chapter 2 Install the Monitor
Grounding and Bonding Whenever two connected pieces of equipment are far apart, it is possible that
their ground connections could be at a different potential level.
To overcome possible grounding problems, the following bonding methods are
recommended:
• Method 1: Connect the data cable shields to the Equipotential bonding
rail on both sides before connecting the cable to the interfaces.
• Method 2: Use an Equipotential bonding cable (16mm2) to connect the
grounds between the monitor and a VersaView 6300P panel PC.
1
5
2
6
3
4
Table 3 - Peripheral Connections for Long-Distance Monitors
Item
No. Cable
Type Required
Attribute Item
No. Cable
Type Required
Attribute
1RVL(1)
(1) Remote video link. Requires specific Ethernet cables; see Table 4.
Shielded
5 DC power Unshielded
2 3 x USB 2.0 6 AC power
3USB2.0
(2)
(2) Optional feature.
4USB2.0
(3)
(3) Only certain models offer a USB 2.0 port on the front bezel.
IMPORTANT: USB ports on front bezels of 6300M-xxxBA and 6300M-xxxBB monitors are not
for use in hazardous locations.
IMPORTANT For optimal performance, use only Rockwell Automation-approved active
DisplayPort adapters.
Table 4 - Available Accessories for VersaView 6300M Panel Monitors
Category Cat. No. Description
Remote Video Link (RVL) cables
for long distance monitors
6300V-15RVLFIXED Cable 15 m (49.2 ft), Cat 5e SF/UTP type, for fixed laying, min bend radius 50.4 mm (2 in.)
6300V-20RVLFIXED Cable 20 m (65.6 ft), Cat 5e SF/UTP type, for fixed laying, min bend radius 50.4 mm (2 in.)
6300V-30RVLFIXED Cable 30 m (98.4 ft), Cat 5e SF/UTP type, for fixed laying, min bend radius 50.4 mm (2 in.)
6300V-40RVLFIXED Cable 40 m (131.2 ft), Cat 5e SF/UTP type, for fixed laying, min bend radius 50.4 mm (2 in.)
6300V-50RVLFIXED Cable 50 m (164 ft), Cat 5e SF/UTP type, for fixed laying, min bend radius 50.4 mm (2 in.)
6300V-100RVLFIXED Cable 100 m (328 ft), Cat 6A S/FTP type, for fixed laying, min bend radius 90 mm (3.5 in.)
6300V-5RVLFLEX Cable 5 m (16.4 ft), Cat 5e SF/UTP type, for not guided flex laying, min bend radius 94.5 mm (3.72 in.)
6300V-10RVLFLEX Cable 10 m (32.8 ft), Cat 5e SF/UTP type, for not guided flex laying, min bend radius 94.5 mm (3.72 in.)
6300V-15RVLFLEX Cable 15 m (49.2 ft), Cat 5e SF/UTP type, for not guided flex laying, min bend radius 94.5 mm (3.72 in.)
6300V-20RVLFLEX Cable 20 m (65.6 ft), Cat 5e SF/UTP type, for not guided flex laying, min bend radius 94.5 mm (3.72 in.)
6300V-25RVLFLEX Cable 25 m (82 ft), Cat 5e SF/UTP type, for not guided flex laying, min bend radius 94.5 mm (3.72 in.)
6300V-30RVLFLEX Cable 30 m (98.4 ft), Cat 5e SF/UTP type, for not guided flex laying, min bend radius 94.5mm (3.72 in.)
6300V-35RVLFLEX Cable 35 m (114.8 ft), Cat 5e SF/UTP type, for not guided flex laying, min bend radius 94.5 mm
6300V-40RVLFLEX Cable 40 m (131.2 ft), Cat 5e SF/UTP type, for not guided flex laying, min bend radius 94.5 mm
6300V-45RVLFLEX Cable 45 m (147.6 ft), Cat 5e SF/UTP type, for not guided flex laying, min bend radius 94.5 mm
6300V-50RVLFLEX Cable 50 m (164 ft), Cat 5e SF/UTP type, for not guided flex laying, min bend radius 94.5 mm
Adapters and other cables
6200V-DPVGA2 DisplayPort to VGA active adapter
6200V-DPDVI2 DisplayPort to DVI-D active adapter
6200V-DPHDMI4K DisplayPort to HDMI active adapter
6200V-DPCBL2M DisplayPort to DisplayPort cable, 2 m (6.5 ft) long
6300V-5MDVIUSB DVI-D to UBS 2.0 cable, 5 m (16.4 ft) long
6200V-USBCBL2M USB to USB touch screen cable, 2 m (6.5 ft) long
Table of contents
Other Rockwell Automation Monitor manuals

Rockwell Automation
Rockwell Automation Allen-Bradley 6186M Series User manual

Rockwell Automation
Rockwell Automation Allen-Bradley 6185-H User manual

Rockwell Automation
Rockwell Automation 6181P User manual

Rockwell Automation
Rockwell Automation Allen Bradley Bulletin 6185-C 15 User manual

Rockwell Automation
Rockwell Automation 6185-D User manual

Rockwell Automation
Rockwell Automation Allen-Bradley 6176M-15VN User manual