ROL ERGO ECS-2 Manual

Flygplatsvägen 1 | SE-555 93 Jönköping | Sweden
E-mail: [email protected] | Phone: +46 (0) 36 31 88 00
Web: www.rolergo.com | Fax: +46 (0) 36 36 89 62
Date: 2012-10 | Version: 1.2
The Sit N’ Stand Concept
FUNCTION
Control: 2-parallel system
Speed: up to 30mm/second
Soft start: progressive acceleration ensures soft
height adjustment
Maximum load: 120 kg
Travel range: 500, 600 & 650mm
ELECTRONIC DATA POWER UNIT
Input: 110-240V
Frequency: 50/60Hz
Output: 29V
Power Plug: EU
OPERATING ENVIRONMENT
Compatibility: Motor hall sensor Bosch 24V,
actuator ED
Operating Cycle: 1 minute on, 9 minutes off
Operating Temperature: +10° C to +40° C (indoors)
OPTIONS
Color Control Unit: black, white
Collision detection: on/off
MATERIALS:
Cover Control Unit: ABS plastic
DIMENSIONS & WEIGHT
Control unit: 115 x 96 x 23 mm, 95 g
Power unit: 115 x 53 x 37 mm, 330 g
Power cables: Length 1500 mm (primary side)
Length 1900 mm (secondary side)
Motor cable: Length 1500 mm
ENERGY USE
Standby: 0,5 W
Operation: 88 – 146 W at 0-120kg load
Control System ECS-2 - Technical specification
Developed by ROL ERGO for seamless integration with height
adjustable frames.
Control box and hand switch consolidated in one compact and
lightweight unit.
Energy-efficient allow for up to 50W lower consumption compared
to previous generations.
NEW
Flygplatsvägen 1 | SE-555 93 Jönköping | Sweden
E-mail: [email protected] | Phone: +46 (0) 36 31 88 00
Web: www.rolergo.com | Fax: +46 (0) 36 36 89 62
Date: 2012-10 | Version: 1.2
The Sit N’ Stand Concept
Control System ECS-2 - Technical specification
SAFETY FEATURES
Overheating Protection: Table is inoperable when the overheating protection has shut down the control unit.
Control unit will be reactivated automatically when temperature has dropped sufficiently.
Intermittency Function: The operating cycle of the control unit is 10%, which means that the table can be operated for
1 minute at maximum load, after which it will stop and must remain inactive for nine minutes.
Lesser loads allow for longer operating cycles. Control unit is automatically reset.
Memory Function: The control unit stores information on the elevation of the table at all times. This information remains
stored even when the power supply is interrupted, for instance during a blackout or if the power
plug is disconnected
STANDARDS & ENVIRONMENT
EMC
Control Unit: RoHs WEE CE Reach
Power Unit: WEE CE UL TÜV/GS
Stand with mounted control systemHand control with built-in control system. Power source
0 50 100 120
UP
DOWN
40
30
20
10
0
mm/sec
Kg
LOAD/SPEED
0 20 40 60 80 100 120 160
STANDBY
OPERATION
160
140
120
100
80
60
40
20
0
W
Kg
OUTPUT IN STANDBY AND OPERATION
0 50 100 120
UP
DOWN
40
30
20
10
0
mm/sec
Kg
LOAD/SPEED
0 20 40 60 80 100 120 160
STANDBY
OPERATION
160
140
120
100
80
60
40
20
0
W
Kg
OUTPUT IN STANDBY AND OPERATION
Flygplatsvägen 1 | SE-555 93 Jönköping | Sweden
E-mail: [email protected] | Phone: +46 (0) 36 31 88 00
Web: www.rolergo.com | Fax: +46 (0) 36 36 89 62
Date: 2012-10 | Version: 1.2
The Sit N’ Stand Concept
User Instructions - Control Unit ECS-2
FRAME ASSEMBLY
Assemble columns Leg system, foot/feet and bar/bars
Make sure that the power cable is correctly secured by slotting it into the groove in the motor housing.
CONNECTING CONTROL UNIT
1. Mount the control unit to the desktop in the desired location.
2. Connect the motor cables
3. Connect the power unit to the control unit and the power outlet
4. Remember to reset the unit on first use
RESETTING UNIT ON FIRST USE
Before the table can be used, the control unit must be reset to establish
the lowest point of the table. This is achieved by first lowering the table
as far as it will go. Until this is done, it will not be possible to elevate
the table.
RESETTING AFTER REPLACING CONTROL UNIT
If a control unit is replaced or switched, the new control unit must first be
reset to establish the lowest point of the table. To do this, press and hold
the “Up” and “Down” buttons simultaneously for at least 7 seconds and
then press “Down” to bring the table to the lowest point. The control unit
will now have registered the lowest point and the table is ready for use.
Verify correct functionality by elevating the table to the highest point and
then back to the lowest point.
The control unit is equipped with two safety features; the intermittency function and the overheating protection
• Intermittency function – The intermittency factor of the control unit is 10%, meaning it can be operated for 1 minute after which it must remain
inactive for 9 minutes. If the one-minute limitation is exceeded, the table will become inoperable until the control box resets automatically.
• Overheating protection – The table will become inoperable if the overheating protection is triggered and will return to operation automati-
cally once the heat has dissipated sufficiently
Speed – the speed of the table varies with load (see separate diagram)
Memory function – The control unit will retain information regarding the elevation of the table at all times. This information will remain stored even in
case of power failure or if the power cable is disconnected from the power outlet.
Soft start – Progressive acceleration allows for soft starts and stops
RESET UNIT ON FIRST USE
1. Lower table to lowest point
by pressing “Down” button
2. Table is ready to use
RESETTING AFTER REPLACING CON-
TROL UNIT
1. Press and hold “Up” and
“Down” simultaneously for 7
seconds
2. Lower table to lowest point
by pressing “Down” button
3. Table is ready to use

Popular Control System manuals by other brands

Truma MonoControl CS operating instructions

Truma

Truma MonoControl CS operating instructions

Parker IQAN-MD3 Instruction book

Parker

Parker IQAN-MD3 Instruction book

ENTRYPASS EP.MINI Wiring guide

ENTRYPASS

ENTRYPASS EP.MINI Wiring guide

Snap-On LEVEL5ATC Installation and operation manual

Snap-On

Snap-On LEVEL5ATC Installation and operation manual

Vaillant 0020236294 operating instructions

Vaillant

Vaillant 0020236294 operating instructions

Invicta VR2 Installation guidelines

Invicta

Invicta VR2 Installation guidelines

Vertiv WSN Gateway Installer and user guide

Vertiv

Vertiv WSN Gateway Installer and user guide

Airzone Aidoo Z-Wave Plus AZAI6ZW Series Integration manual

Airzone

Airzone Aidoo Z-Wave Plus AZAI6ZW Series Integration manual

Altecnic Matrix Midi 135D Installation, operation & maintenance instructions

Altecnic

Altecnic Matrix Midi 135D Installation, operation & maintenance instructions

Motorisation+ X-TRA4 Instructions and warnings for installation and use

Motorisation+

Motorisation+ X-TRA4 Instructions and warnings for installation and use

PAT DS 50 troubleshooting manual

PAT

PAT DS 50 troubleshooting manual

ETC Insight 2x user manual

ETC

ETC Insight 2x user manual

Raven AccuBoom installation manual

Raven

Raven AccuBoom installation manual

Pilz PSSu WB S IDN operating manual

Pilz

Pilz PSSu WB S IDN operating manual

Siemens SIPLUS HCS HCS PM4000 U/I Compact operating instructions

Siemens

Siemens SIPLUS HCS HCS PM4000 U/I Compact operating instructions

SEFRAM Sequencer COMPACT manual

SEFRAM

SEFRAM Sequencer COMPACT manual

Riello 20081469 Instruction booklet

Riello

Riello 20081469 Instruction booklet

Fagor CNC 8070 Hardware configuration

Fagor

Fagor CNC 8070 Hardware configuration

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.