manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Roland
  6. •
  7. Music Equipment
  8. •
  9. Roland S-1608 - ARCHITECTS AND ENGINEERS User manual

Roland S-1608 - ARCHITECTS AND ENGINEERS User manual

This manual suits for next models

1

Other Roland Music Equipment manuals

Roland V-studio VS-2480 Owner's manual

Roland

Roland V-studio VS-2480 Owner's manual

Roland SD-90 User manual

Roland

Roland SD-90 User manual

Roland RMP-12 User manual

Roland

Roland RMP-12 User manual

Roland V-studio VS-2480 User manual

Roland

Roland V-studio VS-2480 User manual

Roland ME-25 Operating and maintenance manual

Roland

Roland ME-25 Operating and maintenance manual

Roland MT 300s User manual

Roland

Roland MT 300s User manual

Roland V-studio VS-2480 Manual

Roland

Roland V-studio VS-2480 Manual

Roland V-studio VS-2480 Instruction Manual

Roland

Roland V-studio VS-2480 Instruction Manual

Roland SoundCanvas SK-88Pro Operating and maintenance manual

Roland

Roland SoundCanvas SK-88Pro Operating and maintenance manual

Roland VIMA JM-8 User manual

Roland

Roland VIMA JM-8 User manual

Roland eBand JS-8 User manual

Roland

Roland eBand JS-8 User manual

Roland VS-1824 User manual

Roland

Roland VS-1824 User manual

Roland MV-8000 Instruction manual

Roland

Roland MV-8000 Instruction manual

Roland V-Drums TD-02 User manual

Roland

Roland V-Drums TD-02 User manual

Roland Digital Snake S-0808 User manual

Roland

Roland Digital Snake S-0808 User manual

Roland TL-16 User manual

Roland

Roland TL-16 User manual

Roland Sound Canvas SC-55mkII Operating and maintenance manual

Roland

Roland Sound Canvas SC-55mkII Operating and maintenance manual

Roland AC-90 Acoustic Chorus User manual

Roland

Roland AC-90 Acoustic Chorus User manual

Roland S-760 Owner's manual

Roland

Roland S-760 Owner's manual

Roland MKS-20 User manual

Roland

Roland MKS-20 User manual

Roland SCB-55 User manual

Roland

Roland SCB-55 User manual

Roland S-330 Operating and maintenance manual

Roland

Roland S-330 Operating and maintenance manual

Roland S-4000S User manual

Roland

Roland S-4000S User manual

Roland AT-4 User manual

Roland

Roland AT-4 User manual

Popular Music Equipment manuals by other brands

Aguilar CHORUSAURUS user guide

Aguilar

Aguilar CHORUSAURUS user guide

Fishman NEO-D user guide

Fishman

Fishman NEO-D user guide

HEXDEVICES Tama 12 user manual

HEXDEVICES

HEXDEVICES Tama 12 user manual

Mesa/Boogie Flux-drive owner's manual

Mesa/Boogie

Mesa/Boogie Flux-drive owner's manual

DOLFINOS The CARBON Edition user manual

DOLFINOS

DOLFINOS The CARBON Edition user manual

DAPAudio IPS-PT user guide

DAPAudio

DAPAudio IPS-PT user guide

Dynacord DPM 8016 owner's manual

Dynacord

Dynacord DPM 8016 owner's manual

Moen GEC8 Live owner's manual

Moen

Moen GEC8 Live owner's manual

Fender 1 brochure

Fender

Fender 1 brochure

Yamaha MLC-16 operating manual

Yamaha

Yamaha MLC-16 operating manual

Sonuscore TIME TEXTURES manual

Sonuscore

Sonuscore TIME TEXTURES manual

flight of harmony V'Amp user guide

flight of harmony

flight of harmony V'Amp user guide

NANO PERFORMANCE MIXER quick guide

NANO

NANO PERFORMANCE MIXER quick guide

BHI NEIM 1031 MKII user guide

BHI

BHI NEIM 1031 MKII user guide

Befaco KICKALL user manual

Befaco

Befaco KICKALL user manual

Paia 9720 Assembly and using manual

Paia

Paia 9720 Assembly and using manual

limex ALPIN MASTER 128 user manual

limex

limex ALPIN MASTER 128 user manual

nord Electro 3 user manual

nord

nord Electro 3 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

801 West Orchard Drive, Suite 3
Bellingham, WA 98225
WWW.ROLANDSYSTEMSGROUP.COM
TOLL FREE: 800.380.2580 • FAX: 800.634.8202
Architects & Engineers Speci cation
The digital audio transmission system
(Digital Snake) shall consist of at least two
modules. The  rst (Stage Module) shall
have 16 XLR inputs and 8 XLR outputs. The
second (FOH) Module shall have 16 XLR
outputs and 8 XLR inputs. The transmission
cable between the Stage Module and the
FOH Module shall be a Cat5e or Cat6 cable.
The inputs shall be of very high quality
and accept both line and microphone level
inputs with individually selectable phantom
power. The input gains or trims for the
inputs as well as their individually selectable
phantom power settings shall be remotely
controllable from the Stage or FOH Module
using either a hardware remote control
unit or a computer. The gain level shall be
controllable in 1 dB steps from microphone
level to line level. The system shall also
offer at least 10 preset memories of
different con gurations of the input gain and
phantom power settings.
The audio protocol shall have a 96 kHz
sampling rate, deliver 24-bit audio, and have
a protocol latency of 375 microseconds from
the stage unit to the FOH unit. The Input
Module shall allow the user to duplicate or
“split” the input sources to several Output
Modules using a fast gigabit Ethernet
switching hub.
The system shall be the S-1608 Digital
Snake System.
S-1608 / S-0816 Dimensions
401
177
135
S-1608 / S-0816 with Rack Mount Kit Dimensions
101.6
177
135
482
465
S-1608 Digital Snake System
801 West Orchard Drive, Suite 3
Bellingham, WA 98225
WWW.ROLANDSYSTEMSGROUP.COM
TOLL FREE: 800.380.2580 • FAX: 800.634.8202
Architects & Engineers Specication
Number of Channels
AD and DA Conversion
Frequency Response
Total Harmonic Distortion + Noise
Dynamic Range
Cross Talk
Nominal Input Level
PAD
Input Impedance
Nominal Output Level
Output Impedance
Recommended Load Impedance
Residual Noise Level (IHF-A, typ.)
Equivalent Input Noise Level
Network Latency
Connectors
Indicators
Power Supply
Power Comsumption
Phantom Power
Dimensions
Weight
Operation Temperature
Accessories
S-1608 : 16 in 8 out S-0816 : 8 in 16 out
24 bit / 96 kHz (auto-switchable to 44.1kHz & 48kHz)
-2 dB / +0 dB (@ +4 dBu, 20 Hz to 20 kHz)
0.05 % or less (Pad: On, Input Gain: +4 dBu, 22Hz to 20 kHz)
110 dB
-80 dB or less (Input Gain: +4 dBu, typ.)
-65 to -10 dBu (PAD: Off), -45 to +10 dBu (PAD: On)
(1 dB step, Max. +28 dBu)
20 dB On/Off
14 k ohms
+4 dBu, Max. +22 dBu
600 ohms
10 k ohms or greater
-80 dBu or less
S-1608: -128 dB S-0816: -124dB
375 microseconds when using REAC cable only (*1)
(AD>REAC>DA Latency: approx 1.2 ms)
S-1608 : Analog Input x 16 (XLR type, balanced, phantom power)
Analog Output x 8 (XLR type, balanced)
Digital Output connector x 1 (Optical type)
REAC Connector x 1 (RJ-45 EtherCon type)
Remote Connector x 1 (RS-232C, DB-9 type)
S-0816 : Analog Input x 8 (XLR type, balanced, phantom power)
Analog Output x 16 (XLR type, balanced)
Digital Output connector x 1 (Optical type)
REAC Connector x 1 (RJ-45 EtherCon type)
Remote Connector x 1 (RS-232C, DB-9 type)
POWER Indicator x 1, REAC Indicator x 1,
REMOTE Indicator x 1, MUTE ALL OUTPUTS Indicator x 1
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
45W
+48 V / 14 mA (each input, remote controlled)
401 (W) x 135 (D) x 177 (H) mm or
15-13/16 (W) x 5-3/8 (D) x 7 (H) inches
5.5 kg 12 lbs 3 oz
0 to +40 degrees Celsius
+32 to +104 degrees Fahrenheit
Power Cord x 1, REAC Connector Cover x 1, Ferrite Cores x 1
Rubber Foot x 4, Rack Mount Kit x 1, Owner's Manual
*1: When a REAC Splitter S-4000-SP or a switching hub is used in-line with REAC cables, the network latency will increase by the
amount of processing delay introduced by the splitting device itself. The actual delay is dependant upon the specifications of the
splitting device.
* 0 dBu = 0.775 Vrms
S-1608 / S-0816 Main Specifications
S-1608 Digital Snake System