2. Generalprovisions
•Thismanualispartoftheproductand mustbestorednearthedevice toallowquickand easyaccess
to information.
•Thedevice is notintended foruseforpurposes other than thosedescribed in this manual.
•Thedevice mayonlybeusedforthepurposesforwhichit hasbeendesignedand inaccordancewith
theconditions stipulated bythemanufacturer.
•Theproductmustnotbeused as asafetydevice.
•Before use,check therangeofconditions forthegiven application.
•Theoperatormustregularlyconductavisualcheck ofthedevice and ensurebasicmaintenance.
3. RomotopDIRECTautomaticregulatorparameters
Technicalparameters
•Power supply:230VAC+/-15%
•Consumption:1.4 Wwhen theservomotoris running
•Consumption:1.2 Wwhen theservomotoris notrunning
•Ingress protection:IP20
•Noiselevel: <42 dB
•Inputs:1 analog– temperature sensor
1 logiccommand -doorswitch
1 power supply(230VAC+/-15%)
•Outputs:1 servomotorcontrol(24VAV/DC, 1VA)
1 acoustic– signals whenstokingis required
1 optical– LEDsignalization oftemperature (1xgreen, 3x yellow, 1xred)
•Theelectricaldevicewastested in accordancewith thefollowingstandards: SNEN60730-1, SN
EN55022 and SNEN61000-6-1.
•Theelectricaldevicecomplies with thefollowingstandards: SNEN55014-1 ed.3:2007, SNEN
55014-2:1998, SNEN62233:2008, SNEN61000-3-2 ed.3:2006, SNEN61000-3-3 ed.2:2009,
SNEN60335-1 ed.2:2003, SNEN60335-2-102:2007
Parameters ofthecentralunit
•Frontpaneldimensions:125x95 mm
•Recess depth:80mm
•Weight: 200 g
•Installation:theunit is designed to beinstalled in awall, alternativelyon the
fireplacestovebody, in theplace designated bythestovemanufacturer
•Degreeoffouling:1 /dry, non-conducting/
•Operatingtemperature:0 to 50°C
•Storagetemperature:-10 to +60°C
•230 Vconnection cablenotincluded in thedelivery!!!
•Rated pulsevoltage:categoryII
•Forconnection ofindividualconductors referto thewiringdiagram
Accessories included:
•1x RomotopDirect regulationunit
•1xrecess box(forwall installation)
•1xtemperature sensorwith screwfitting
•1xservomotorwith installation accessories, includingcables
•!230Vconnection cablenotincluded in thedelivery!
Additionalaccessories:
•doorswitchwithconnection cable-theassemblydiagramforthedoorswitchisincludedinthe
delivery
4. Descriptionoftheregulationprocess
Whenstartingafire inthefireplacestove,the RomotopDirect automaticregulation unit willbeginthe
process ofregulatingcombustion byeither manuallypressingthestartbutton orthedoorswitch.Thesystem
assessesthetemperatureinthecombustion chamber fromthebeginningofthecombustion process. Basedon
thisvalue,the RomotopDirect automaticregulation unit evaluatesthestateofcombustion inthecombustion
chamber and optimizestheamountofairand place it issuppliedinthecombustion process. Theamountofair
suppliedisrealizeddirectlythroughthefireplaceinsert(fireplace stove) fixer,whichistheonlyregulatory
componentdesignatedand allowedbythemanufacturer.The RomotopDirect automaticregulation unit also
optimizesthecombustionprocess basedon information whether thefireisbeingstarted, heatingisinprogress
orit istheend ofthecombustion process. Everytimethestartbutton ispressed, orthefeedingdoorwithadoor
switch is opened during thecombustion process, the RomotopDirect automaticregulationunit re-evaluatesand
re-optimizesthecombustion process basedon thecurrentstateoftheinterruptedcombustion cycle.Attheend
ofthecombustion cycle,anacousticsignalsounds and thegreenLEDstartstoflash to informtheuser thestove
shouldbestokedand anewcombustion cyclestarted. Theprogress ofthecombustion cycleismonitoredby
LEDs installedundertheglass ofthefrontpanelofthe RomotopDirect automaticregulation unit (forthecolor
spectrum,seethe Operation section).Attheendofheatingand blowingthroughthecombustion chamber,the
airintaketothechamber iscompletelyclosed. Theregulatorswitchesto STANDBY modeuntil thenextfire is
started.
Graphofthedependenceoftemperatureand timeinregulated and non-regulated combustion
non-regulated burningcurve
regulated burning curve
time
temperature