Button/Selector Descriptions:
Button Name Button Description
SWITCH For the SWITCH selector you can choose either MOMENTARY or LATCHING.
MOMENTARY means the relay is only activated while the trigger wire for that
circuit is activated. LATCHING means the relay is activated continuously once
the trigger wire has been activated and will be deactivated once the trigger wire
is activated again.
IGNITION The IGNITION selector chooses whether the relay circuit is activated only with
the ignition turned on or all the time (whether ignition is on or not). ALWAYS
ON means the relay circuit can be activated whether the ignition system is on
or not. IGNITION ON means the relay circuit can only be activated when the
ignition system is on.
INPUT The INPUT selector chooses whether you are activating a relay circuit by
applying power to the trigger wire or ground to the trigger wire. SWITCH PWR
means you will be controlling a relay circuit by applying power to the trigger
wire. SWITCH GND means you will be controlling a relay circuit by applying
ground to the trigger wire.
OUTPUT The OUTPUT selector chooses whether your device attached to th relay circuit
is receiving a ground or power. Choose SWITCH PWR if the equipment
connected to the relay circuit requires power to operate. Choose SWITCH GND
if the equipment connected to the relay circuit requires ground to operate. The
OUTPUT selector also has a WINDOWS option. The WINDOWS option allows
you to program two relay circuits together to create a reversing polarity circuits
for items such as power windows.
Programming:
With the ignition on or off you can wake up the BX-10 by pressing any button for two seconds.
Once the unit is active, press any relay circuit button for two seconds and the light for that relay circuit
will light up and the selector buttons will reflect how that relay circuit is programmed.
To program a single relay circuit:
1) Chose from the selectors to program how you want that circuit to behave: SWITCH, IGNITION,
INPUT, OUTPUT. See Button/Selector description section for more information/definitions.
2) Once you have made your choices on the selectors, press and hold the PROGRAM and the relay
circuit button at the same time until the relay circuit’s light flashes. That relay circuit is now programmed
to whichever selector switches you chose.
NOTE: If you plan to activate any circuits with a common ignition hot that is also running to the
ignition on connector on the end of the BX-10, it is recommended to program those circuits to
ALWAYS ON. The circuits will still only activate when the ignition is activated but will prevent any
possible intermittent performance due to switching circuits at the same moment box is receiving
the ignition on signal. No additional load will be incurred when ignition is turned off.