Ronda QM2 User manual

Installation, Use & Care
Guide
Double Drawer / Not insulated Units QM2

IL-MO-045 Rev. 0 05/2010
Double Drawer Unit – QM2
not insulated
Pag. 2 / 12
PROFESSIONAL INSTALLATION REQUIRED
Welcome & congratulations
Congratulations on your purchase of this double drawer.
We at Ronda are very proud of our product and we hope you consider us for fu-
ture purchases.
This product is made in our factory in Italy with components all made in Italy.
For any questions contact us at : info@ronda.it
PLEASE READ CAREFULLY AND SAVE THESE INSTRUCTIONS
Packaging contents:
# 1 SMC Frame
# 2 Drawers
# 3 Stainless Steel Frame
2
2
1
3

IL-MO-045 Rev. 0 05/2010
Double Drawer Unit – QM2
not insulated
Pag. 3 / 12
PROFESSIONAL INSTALLATION REQUIRED
Notes and Installation Tips
ALWAYS USE PROTECTION GLOVES AND EYE SAFETY GOGGLES:
Use care and always use protection gloves and safety goggles during in-
stallation and care. Because the drawers may have sharp edges, if not
handled with care they can cause cuts and abrasions.
Tools you will need : Power screw driver, manual screw driver, level, tape
measure.
Carefully unpack cabinets making sure not to scratch stainless steel fronts
and not to loose or misplace any components.
DO NOT remove polyethylene protective coating until installation is com-
plete.
Remove all drawers before installation. This will make cabinet easier to lift
and install and give access to installation hardware.
This product is made only for application on a subframe, which can be
made in different materials (wood, plastic, alluminium) into a wall structure
(Fig. 1)
Do not use the drawers as ladder. This would be dangerous for you and can
cause the item to break.
Fig. 1
a
b
Subframe

IL-MO-045 Rev. 0 05/2010
Double Drawer Unit – QM2
not insulated
Pag. 4 / 12
PROFESSIONAL INSTALLATION REQUIRED
Before Installation
Verify model number on the box label.
Verify the counter hole measure refering to the following table :
The maximum deviation permitted is : 0.04’’ (1 mm). Otherwise the SMC
frame get deformed and drawers don’t work properly. Use spacers to get
the right counter hole dimensions.
Check with a level that the wall is plumb.
Verify with a level the horizontal and vertical level of the counter hole and
correct if not accurate.
Counter Hole
Model a b
+0,04 + 0,04
inch
16,96
0
24.44
0
+1 +1
QM21
mm 431
0
621
0

IL-MO-045 Rev. 0 05/2010
Double Drawer Unit – QM2
not insulated
Pag. 5 / 12
PROFESSIONAL INSTALLATION REQUIRED
Assembly and Installation
1.
Carefully unpack cabinet making sure not to scratch stainless steel fronts.
Stainless is protected by a plastic coating that must be removed after
setup.
2.
Remove drawers and store in a safe place.
3.
Use protection gloves
4.
Put the frame inside the
counter hole.

IL-MO-045 Rev. 0 05/2010
Double Drawer Unit – QM2
not insulated
Pag. 6 / 12
PROFESSIONAL INSTALLATION REQUIRED
5.
Be sure that the SMC
frame fits well in the wall.
If not, use spacers to fit.
6.
Secure the SMC frame to
the wall with screws into the
dedicated matching holes.
Use # 10 mushroomhead
screws (not included).
The use of screws with dif-
ferent heads can cause an
interference with the
drawer guides.

IL-MO-045 Rev. 0 05/2010
Double Drawer Unit – QM2
not insulated
Pag. 7 / 12
PROFESSIONAL INSTALLATION REQUIRED
7.
Insert the drawer rear
wheels into the guide
slots.
To do this easier you
must incline the front
down a bit.
8.
Close thedrawer completely
and repeat theoperation for
thesecond drawer.

IL-MO-045 Rev. 0 05/2010
Double Drawer Unit – QM2
not insulated
Pag. 8 / 12
PROFESSIONAL INSTALLATION REQUIRED
Care and cleaning
It is imperative that the owner realizes that he/she is required to perform
reasonable maintenance and care of the drawers in order to maintain the
manufacturers warranty. Failure to perform reasonable maintenance and
care may void the warranty.
The following is a list of maintenance steps and things to avoid. This is
not intended to be a complete list, but is to be used as a guideline for
general care.
Carefully remove protective plastic peel coat from each stainless steel surface.
External Surfaces:
Clean stainless with stainless steel cleaner in direction of grain. Rubbing across
the grain direction may produce minor scratches. Recommended cleaners are
Weiman
©
, Stainless Steel Magic
©
and Sheila Shine
©
.
In a salty air environment, a slightly more oily cleaner like Sheila Shine
©
will
protect better against oxidation, pitting or slight surface rust. Cleaning the sur-
faces periodically will protect the finish for many years. In a heavily salty area,
you will have to clean more frequently as salt breaks down into highly corrosive
chlorine that will attack the metal. Surface corrosion will not affect performance
of the product, but will affect the look.
DO NOT USE scratchy pads, scouring pads, or stiff sponges for cleaning. Do
not use abrasive detergents, powdered cleansers or detergents containing acid
substances or bleach.

IL-MO-045 Rev. 0 05/2010
Double Drawer Unit – QM2
not insulated
Pag. 9 / 12
PROFESSIONAL INSTALLATION REQUIRED
Removing and cleaning the magnetic gasket :
•Carefullyinsertascrewdriverintoacornerof
thegasket(1).
•Liftthegasketuntilitexits fromtheseat(2).
•Removethegasket byhand(3).
•Cleanwithwaterandneutraldetergent.
•Insertthegasketinitsseatand strongly
pressitonalltheperimeter.Youcanlubri-
catethegasketseattodothiseasly.
Drawer Guides
Drawer load capacity should not exceed 50 lbs per drawer. Never use an ex-
tended drawer for a ladder or a work platform.
1
2
3

IL-MO-045 Rev. 0 05/2010
Double Drawer Unit – QM2
not insulated
Pag. 10 / 12
PROFESSIONAL INSTALLATION REQUIRED
WARNINGS
•Surfaces can be very hot when exposed to direct sunlight.
•Molds can form if not properly dried.
•Do not use as a ladder.
•Avoid any contact with electrical outlets or wires.
•This is only a food container. It is not a refrigerated space,
and will not prevent food spoilage.
•If exposed to temperatures below – 4 °F and above + 120 °F
deformation and malfunction of the drawers can occur.
•If installed adjacent to the heating elements of a barbeque,
insulation can be less effective.
•If installed near to the sea, damage from salty water can oc-
cur.
•Keep drawers closed when not in use.

IL-MO-045 Rev. 0 05/2010
Double Drawer Unit – QM2
not insulated
Pag. 11 / 12
PROFESSIONAL INSTALLATION REQUIRED
LIMITED WARRANTY:
1. Limited Warranty.
RONDA warrants for a period of one (1) year from the date of purchase that each new
RONDA product shall be free, under normal use and maintenance, from any defect in mate-
rial and workmanship, subject to the exclusions and limitations set forth below.
2. Exclusions:
The limited warranty offered by RONDA is not applicable:
a. to products subject to wear and tear as part of their normal function (rubber parts);
b. to defects resulting from oxidation, damages from salty environment or the action of
atmospheric agents;
c. to defects resulting from incorrect use, misuse, neglect or abuse of the product or
failure to carry out the maintenance recommended by RONDA;
d. removal of drawers from their original location.
e. “remodeling” after original installation.
f. defects caused by failure to provide suitable installation environments for the prod-
uct, including without limitation the frame ; and
g. to defects resulting from faulty installation, modifications or adjustments not recom-
mended or authorized by RONDA in writing, or repairs carried out improperly.
3. Coverage.
RONDA will remedy any material or workmanship found to be defective within the one (1)
year limited warranty term as follows:
Any RONDA product which is found defective in material or workmanship within the one (1)
year limited warranty term shall be repaired or replaced, at the option of RONDA, at the
RONDA facilities located at
UTi, United States, Inc.
3717 Wilson Road SE, Suite 100
Atlanta
GA 30354
without charge. Any defective RONDA product replaced under this warranty shall become
the property of RONDA.
4. Limitation.
The liability of RONDA under this limited warranty is limited solely to the repair or replace-
ment of defective product at the RONDA location during normal business hours, without
charge for you. Defects and delays in repair do not give you a right to compensation. This
limited warranty does not include any expense of or related to transportation of the RONDA
product to or from the RONDA location or compensation for inconvenience or loss of use of
the product while the RONDA product is being repaired or replaced. TO THE MAXIMUM
EXTENT PERMITTED BY APPLICABLE LAW, RONDA SHALL NOT BE LIABLE FOR ANY

IL-MO-045 Rev. 0 05/2010
Double Drawer Unit – QM2
not insulated
Pag. 12 / 12
PROFESSIONAL INSTALLATION REQUIRED
OTHER EXPENSE, LOSS OR DAMAGE, WHETHER DIRECT, INCIDENTAL, CONSE-
QUENTIAL, OR EXEMPLARY ARISING IN CONNECTION WITH THE SALE OR USE OF
OR INABILITY TO USE THE RONDA PRODUCT FOR ANY PURPOSE.
This limited warranty shall constitute your sole remedy and the sole liability of RONDA, whe-
ther on warranty, contract or negligence grounds, with regard to any actual or alleged defect
in the condition or performance of any RONDA product. TO MAXIMUM EXTENT AL-
LOWED BY APPLICABLE LAW, THE FOREGOING STATEMENTS OF WARRANTY ARE
EXCLUSIVE AND IN LIEU OF ALL OTHER REMEDIES.
RONDA’S LIABILITY ON ANY CLAIM OF ANY KIND RELATING TO THESE TERMS OR
THE MANUFACTURE, SALE, DELIVERY, RESALE OR USE OF ANY RONDA PRODUCT,
SHALL IN NO EVENT EXCEED THE PRICE OF THE RONDA PRODUCT WHICH GAVE
RISE TO ANY SUCH CLAIM.
Some States do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
5. Disclaimer.
RONDA is not responsible for any accidents which may occur while the RONDA product is
being used or as a result of, or causes arising from, its installation or use and shall not be li-
able for any loss, damages or harm to persons or things derived from the same. RONDA is
not responsible for any damage to the drawers or to the outer casing caused by failure to
properly maintain the product.
This warranty gives you specific legal rights, and you may also have other rights
which vary from State to State.
6. Force Majeure.
RONDA shall not be responsible for any loss, damage or delay caused by industrial distur-
bances or disputes, strikes, fire, acts of nature, acts of God, casualty, embargoes, currency
restrictions, labor, conflicts or shortages, war, radiation, civil riot, import or export restric-
tions, shortage of materials or labor, or any other cause beyond RONDA’s reasonable con-
trol, even if RONDA knew, had reason to believe, or was advised of the possibility or prob-
ability of any such cause.
Ronda S.p.A.
Via Vegri, 83
36010 Zanè (VI) ITALY
Tel. +39 0445 385600 – Fax +39 0445 385700
Email: info@ronda.it
www.ronda.it
This manual suits for next models
1
Table of contents
Other Ronda LCD Drawer manuals
Popular LCD Drawer manuals by other brands

Acnodes
Acnodes KDS 6178 Specifications

Zline
Zline Attainable Luxury 24" Installation guide and user's manual

ATEN
ATEN CN8600 quick start guide

Rose electronics
Rose electronics Rackview LCD Panel Mount 19" Installation and operation manual

Acnodes
Acnodes MKD6019D user manual

Husky
Husky H46CH6 Use and care guide