Room & Board 140NG User manual

08142019-3-KV
140NG Estes Low Square Fire Table
Owner’s Manual
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper,
tent, car or home.
DANGER!
FIRE OR EXPLOSION HAZARD
If you smell gas:
• Shut o gas to the appliance.
• Extinguish any open flame.
• If odor continues, leave the area
immediately.
• After leaving the area, call your
gas supplier or fire department.
Failure to follow these instructions
could result in fire or explosion,
which could cause property damage,
personal injury, or death.
!DANGER !WARNING: FOR OUTDOOR USE ONLY.
Installation and service must be performed by a
qualified installer, service agency, or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
!
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may result
causing property damage, serious injury, or loss of life.
!
WARNING: Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this
or any other appliance.
An LP gas tank not connected for use shall not be
stored in the vicinity of this or any other appliance.

TABLE OF CONTENTS
Important Safety Information
Natural Gas (NG) Dangers and Warnings
Parts List
Assembly Instructions
Pre-Use Instructions
Lighting Instructions
Care and Cleaning
Spider and Insect Warning
Tips and Troubleshooting
Technical Parts List
Warranty and Return Policies
SPECIFICATIONS
Product Name
Estes Low Square Fire Table
Model No.
140NG
Rated Heat Output
60,000 BTUs/hr
Type of Gas
Natural Gas (NG)
Gas Supply
Professionally Installed
NG System
2
ATTENTION
Please register your fireplace for recall notifications, proof of ownership
and quality assurance at https://www.realflame.com/registration.
3
5
6
7
10
11
12
13
14
15
16

IMPORTANT SAFETY INFORMATION
General Warnings
•Children and adults should be alerted to the hazards of high surface temperatures
and should stay away to avoid burns or clothing ignition.
•Children should be carefully supervised when in the area of the fireplace.
•Clothing or other flammable materials should not be hung from the fireplace or placed
on or near the fireplace.
•Any guard or other protective device removed for servicing the fireplace must be
replaced prior to operating the fireplace.
• Installation and service must be performed by a qualified service agency or gas
supplier. Real Flame recommends using professionals who are certified in the U.S.
by the National Fireplace Institute®(NFI) as NFI Gas Specialists.
• More frequent cleaning may be required as necessary. It is imperative that the
control compartment, burners, and circulating air passageways of the appliance
are kept clean.
• Do not store or use gasoline or other flammable vapors or liquids within 25 ft (7.62 m)
of this fireplace or any other appliance.
• Do not store combustible materials in the fireplace enclosure.
• Be sure to protect the hose and its components from any hot surfaces. It is dangerous
to allow the hose to come into contact with any hot surface.
• Use only the natural gas hose and quick connect assembly provided. The replacement
NG hose and quick connect assembly shall be that specified by the manufacturer.
• Do not attempt to disconnect natural gas hose or quick connect socket from the main
gas supply or any gas fitting while the outdoor fireplace is in use.
• Always shut o gas at the shut-o valve and disconnect the quick connect socket
from the main gas supply when the fireplace is not in use.
• Keep all parts of the fireplace clean including the burner and hose assembly. For more
information on cleaning your fireplace please refer to the “Care and Cleaning” section
of this manual.
• Do not use this fireplace if any part has been under water. Immediately call a qualified
service technician to inspect the fireplace and replace any part of the system that has
been under water.
• Do not use this fireplace for cooking.
• Do not pour water into the fireplace.
• Do not attempt to move or store this fireplace until all parts are cool.
• Always shut o the gas supply at the source and disconnect the hose when the fireplace
is not in use.
•Any alteration of this fireplace that is not specifically directed in the owner’s manual
will void the manufacturer’s warranty. This includes the use of unapproved filler materials.
3

Installation Warnings
•Minimum clearance from the fireplace to combustible materials is 48 inches (121.9 cm) on
all sides. Do not place this fireplace under any overhead structure or vegetation.
•The normal inlet pressure for this fireplace is 7.0" W.C. (1.74 kPa). Maximum inlet pressure
is 10.5" W.C. (2.61 kPa). Minimum inlet pressure is 3.5" W.C. (0.87 kPa).
•A fireplace with a connection to a fixed piping system must conform with local codes, or in the
absence of local codes with The National Fuel Gas Code, ANSI Z223.1/NFPA 54, or International Fuel
Gas Code.
•Do not remove the feet from this fireplace.
•Do not place the fireplace on anything that blocks or seals the gap between the fireplace and the ground.
•Do not permanently secure the fireplace in any way or to any surfaces.
•Do not bury the hose. You must be able to visually inspect the hose for damage before each use.
•Do not coil or hide the hose under the fireplace. The hose could be damaged if it touches hot surfaces.
Set Up Warnings
•Prior to each operation, check the hose assembly for evidence of excessive abrasion, wear or
damage. Use a handheld mirror, if necessary, to see the hose sections located below the unit.
•If the hose assembly is damaged, cracked, or cut, it must be replaced before using the fireplace.
The hose assembly must be replaced with a hose assembly specified by Real Flame.
Please contact Real Flame Customer Service at 1-800-654-1704 for assistance.
•Place the hose out of the pathways where people may trip over it. Do not place the hose
in areas where it may be accidentally damaged.
•Before each use, examine the burner and its components for dirt and debris. If cleaning is required,
use a pipe cleaning brush and compressed air. Also examine the area around the burner.
Any dirt or foreign material, such as spider webs, nests, leaves, etc., should be removed. If it is
evident that the burner is damaged, the fireplace must not be used, and the burner assembly
must be replaced. Please contact Real Flame Customer Service at 1-800-654-1704 for support.
In-Use Warnings
•NEVER LEAVE this fireplace unattended when in use.
•Do not burn solid fuels, such as charcoal briquettes, lump charcoal, manufactured logs, trash, leaves
paper, cardboard, any type of natural or treated wood, or any other materials in this fireplace.
•The use of alcohol, prescription or non-prescription drugs may impair your ability to safely
operate this fireplace.
•Always use in accordance with all applicable local, state, and national codes. Contact your
local fire department for details on outdoor burning.
•Do not use in windy conditions. High winds may cause the flame to extinguish.
•Some surfaces of this fireplace may become hot during use. Be careful and do not touch
surfaces until the unit has cooled.
•Do not attempt to disconnect the gas supply from the fireplace when the unit is in use.
•Do not sit on the fireplace.
4
IMPORTANT SAFETY INFORMATION

NATURAL GAS (NG) DANGERS AND WARNINGS
!DANGER
This outdoor fireplace is for use with natural gas only. The conversion to or attempted use of
liquid propane in this outdoor fireplace is dangerous and could result in property damage,
serious injury, or death.
Natural Gas Characteristics
•Natural gas is flammable, explosive under pressure, lighter than air, and collects in high
areas. Collected gas may ignite causing a fire or explosion which could cause property
damage, serious injury, or death.
•In its natural state, natural gas has no odor. For your safety, a scent has been added.
•Direct contact with natural gas can burn your skin.
•Natural gas is extremely flammable and hazardous if handled improperly.
Natural Gas Information
•This natural gas fireplace is designed to operate on natural gas only at a pressure of
7" W.C. (1.74 kPa).
•Check with your local gas provider for local gas pressure, because in some areas natural
gas pressure varies.
Natural Gas Connection
•It is recommended that an ON/OFF manual shut-o valve be installed outdoors at the
gas supply source after the gas line exits the outside wall or before the gas line enters
the ground, and before the quick connect.
•When making a connection, sealing compound or pipe thread tape of the type resistant to the
action of natural gas must be applied on 3 to 4 threads of all male pipe threads.
•Connect the end of the natural gas hose with the quick release connector to the manual shut-o
valve at the gas supply.
5
!WARNING
Natural gas is flammable and hazardous if handled improperly. Become aware of its characteristics
before using any natural gas product. Failure to understand and follow these warnings or any
directions and warnings provided by your gas supplier may result in property damage, serious
injury, or death.
!CAUTION
During any high pressure testing of the gas supply piping system at test pressures in excess of 1/2
psi. (3.5 kPa) the fireplace and its individual shut-o valve must be disconnected from the gas supply
piping system.
!WARNING
Burner valves are pre-tested at the factory to operate on natural gas. Do not attempt to
convert or change.

PARTS LIST
6
ITEM JCo NUMBER QUANTITY
Fire Table Body N/A 1
NG Hose and 056NG010 1
Quick Connect Socket
Black Lava Rock 100240120J 2
Protective Cover 01400101 1
Key 11110004 1
1
2
3
4
5
1
2
3
4
5

ASSEMBLY INSTRUCTIONS
1. Place the filler material into the burner pan by hand. To avoid clogging the burner with dust
do not dump the bag into the burner pan. Position the filler across the burner pan to a level
that is 1 inch (2.54 cm) above the burner tube. Make sure you do not block the igniter housing
with the filler material to ensure proper ignition and operation.
If using glass filler, Real Flame suggests first placing a layer of lava rock in the burner pan
to improve airflow.
Filler Material Warning
•Do not overfill the burner area with rock or glass filler; use only the specified amount. The
depth of the filler should not be more than 1 inch (2.54 cm) above the burner tube. Only
Real Flame filler products have been certified and tested for safe use with this Real Flame
fireplace. Using other filler material may result in increased popping and cracking or increased
carbon monoxide emissions.
•Do not light or use this fireplace if the filler is wet. Ensure filler is completely dry before lighting.
Intense heat can cause wet filler to explode and hit someone causing property damage,
serious injury, or death.
•Keep away from the fireplace for at least 20 minutes during initial start-up as filler could
retain moisture from manufacturing and shipping.
7

ASSEMBLY INSTRUCTIONS
8
Natural Gas Source
Quick Connect Socket
Natural Gas Hose
Shut-O Valve
To Fireplace
2. Connect the fireplace to the natural gas source:
A professionally installed shut-o valve between the supply piping and the socket is
recommended by The National Fuel Gas Code, and must be used for the fireplace. A
professional gas technician or plumber must make sure that your gas system is capable of
providing the correct amount of gas at the correct pressure for your fireplace to operate
safely and correctly.
The quick connect socket connection must be made outdoors. The diagram below shows the
main components of a standard natural gas connection.
If the socket connection is below the fireplace, no part of the hose may contact the side
panels or base panel of the burner area when the fireplace is in its normal operating position.

ASSEMBLY INSTRUCTIONS
9
Apply gas approved, pipe
compound or tape.
valve on the gas supply line.
Screw the provided quick connect
socket onto the gas supply pipe.
To Fireplace
3. Install the quick connect socket:
Coat the gas supply threading with gas approved pipe compound or tape. Screw the quick
connect socket included with the fireplace onto the gas supply pipe.
The quick connect should not be permanently attached to the gas hose on the fireplace.
The direction of the gas flow is indicated on the socket.
Using one hand, pull back the sleeve on the quick connect socket and with the other
hand, insert the unattached end of the fireplace gas hose into the socket. Release the
sleeve and continue pushing the hose into the socket until the sleeve snaps into the
locked position.
After making the connection, perform a leak check as described on the next page.

10
PRE-USE INSTRUCTIONS
!WARNING
Before using this fireplace, make sure you have read, understand, and are following all information
provided in this manual. Failure to follow these instructions could cause property damage,
serious injury, or death.
Checking for Leaks
1. Make a leak check solution by mixing 1 part dishwashing soap with 3 parts water in a spray bottle.
2. Make sure the control knob on the fireplace is in the “OFF” position, then connect your
fireplace to the gas supply line and turn the gas on.
3. Spray the leak solution on the valve connections, paying particular attention to the areas
indicated by arrows in the diagrams below.
4. If bubbles appear, shut o the gas supply, disconnect the hose and inspect all connections
making sure threads are clear of debris. Reconnect the hose, turn the gas supply on and
retest. If you continue to see bubbles, turn the gas supply o, disconnect the hose, and call
Real Flame Customer Service at 1-800-654-1704 for assistance.
5. If no bubbles appear after 1 minute, wipe away excess leak solution and proceed to
“Lighting Instructions.”
Pay close attention to the areas indicated by the arrows.

11
LIGHTING INSTRUCTIONS
Lighting the Fireplace
1. Read and understand all operating instructions before lighting.
2. Before beginning, make sure the key valve is in the “OFF” position.
3. Connect the quick connect hose to your gas supply.
4. Position a burning long match or long burning butane lighter near the side of the burner.
5. Insert the key and slowly turn the key valve counterclockwise toward the “ON” position.
6. Once the burner has been lit, remove the match/lighter. Observe the flame and make sure
that all of the burner ports are lit.
7. Adjust the flame to the desired height using the key valve.
WARNING: If ignition does not occur in 15 seconds, turn the key valve to the “OFF”
position and turn the gas o at its source. Make sure there is no source of ignition around
the fireplace and wait at least 5 minutes until the gas has cleared to repeat the lighting
procedure. Failure to do so could result in a large flashback of collected gas, causing
property damage, serious injury, or death.
Shut-O Instructions
1. Turn the key valve clockwise to the “OFF” position.
2. Once the flame is out, remove the key, and turn the gas o at the source using the shut-o valve.
3. Store the key in a safe location. If the key is lost please contact Real Flame Customer Service at
1-800-654-1704 for a replacement.
Flame Height
8-14”
(20.3-35.5 cm)
OFF
ON
KEY VALVE

12
CARE AND CLEANING
Inspecting Your Fireplace
!WARNING
DO NOT inspect, clean, move or store your fireplace until the flames are COMPLETELY out
and all parts are cool to the touch.
Your fireplace should be inspected regularly to ensure that it is safe to use and to extend the life of its parts.
Inspect your fireplace:
1. Make sure all parts are securely fastened in place. If a part moves when touched, check its
connection points to see if they are loose.
2. Check all connections for leaks using the method described in the “Checking for Leaks” section
of this manual.
3. Visually check all components for any signs of damage, rust, or excessive wear.
4. If damage or leaks of any kind are found. DO NOT operate the fireplace until the proper
repairs have been made.
!WARNING
DO NOT tamper with this fireplace. This is dangerous and will void the warranty.
Repairs and modifications must be approved by Real Flame and completed by a
professional gas technician.
This fireplace has been tested and certified by a third party certification agency based on its
specific and unique parts. Installing any other parts will void both the certification and the warranty.
For approved replacement parts contact Real Flame Customer Service at 1-800-654-1704.
General Care and Cleaning
After repeated use, a slight discoloration or weathering of the fireplace finish may occur. Your
fireplace should be cleaned regularly to ensure safe use and extend its life.
General Cleaning
Make a cleaning solution using a mild soap mixed with water. Use a soft cloth to wipe down
exterior surfaces and rinse with clean water. Never use oven cleaners or abrasive solvents as
these will damage the fireplace.
Burner
The burner should be kept clean to ensure proper operation. Clogged burner ports may be
cleared with a paper clip or pin. Debris in the burner tube can be cleaned using compressed
air or a pipe cleaning brush.
Soot
After use it is possible for soot to develop on some surfaces. This soot deposit will usually
come o with water and mild soap.
Storage
1. Turn the gas supply o at the source. Remove the quick connect hose from the gas
supply line and coil for storage under the fireplace.
2. Secure all loose filler material or parts.
3. Cover the fireplace when not in use and do not allow water to pool on the cover surface.
Covering the fireplace will help to protect the internal components from dirt and debris
and prevent the finish from fading.
4. Store the fireplace in a cool, dry location away from children and pets.

13
SPIDER AND INSECT WARNING
Spiders or other insects may build webs or nests in your fireplace burner tube which can obstruct
or block the flow of gas.
Some of the gas may back up in the burner tube and cause a flashback (a fire in the burner tube
or underneath the fireplace), which could result in property damage, serious injury, or death.
Check and clean the burner tube periodically using a pipe cleaning brush (shown below) and
compressed air available at any hardware store.
Example of pipe cleaning
brush available at local
hardware store.
Burner Ports
Possible Debris
Possible Debris
Example of a typical burner tube.
Your exact burner tube may vary.

TIPS AND TROUBLESHOOTING
14
If the Fireplace Will Not Ignite or Stay Lit
Make sure that the gas shut-o valve is fully open and that the connection between the
hose and the quick connect socket is correct. Verify that the key valve is not stripped out
and that the valve is opening and closing. Make sure that the hose does not have any kinks
or sharp bends.
Other Common Problems
Clogged or Obstructed Burner
It is common for bugs, especially spiders, to make webs or nests inside of burner tubes. If it
seems like you are getting low or no gas flow, visually check all openings in the burner for
signs of clogs. If you see anything clogging the burner using a pipe cleaner or compressed
air to remove the debris.
High Winds
High winds may cause the flame to blow out. Do not operate your fireplace in high wind
conditions.
Out of Gas
Verify that the shut-o valve is open.
If you continue to have problems with your fireplace please
contact Real Flame Customer Service at 1-800-654-1704.

15
TECHNICAL PARTS LIST
Burner Kit
Key
11110004
Foot x 4
115010003
Protective Cover
01400101
Lava Rock
100240120J
NG Hose and Quick Connect
056NG010

WARRANTY AND RETURN POLICIES
06272019-3
Real Flame®
7800 Northwestern Ave.
Racine, WI 53406
USA
Warranty
Real Flame® Company warrants the body and internal components of this Real Flame gas fireplace to
be free from defects under normal use with a limited 2 year warranty from the date of purchase. The
burner tube and nozzles carry a lifetime warranty. In the event of defects Real Flame will, at its option,
replace the defective product or refund the purchase price. The foregoing is the exclusive remedy and
Real Flame disclaims all other warranties, including any implied warranty of merchantability or fitness
for a particular purpose. In addition, Real Flame will not be responsible for consequential damages in
excess of the purchase price of the product on which such liability is based.
Return Policy
You may return your purchase within 90 days of receipt. No refunds will be issued for incomplete
or unauthorized returns. All returned products must be 100% complete, adequately packaged in
original packaging and in resalable condition. Products that have been assembled or modified will not
be eligible for return. All items must be returned in their entirety, meaning all items included must be
returned together. No returns or exchanges on discontinued items. Please begin the return process
by contacting the store or company where you bought your Real Flame item.
Replacement Parts
In the event that an item has been lost or damaged, either by the manufacturer or in shipping, you
may request a replacement within 30 days of receipt. Replacement parts are not available for all units
and only given at Real Flame’s discretion. We will assess any damage and find a solution, which
could include shipping you a replacement. No replacements are available for discontinued items or
repackaged (open box) products. Please call Real Flame Customer Service at 1-800-654-1704 for replacement
parts before returning the damaged item. Please have the following information (which can be found
in your instruction manual) ready before you call Customer Service:
• Model number of item
• 4-8 digit part number
• Shipping address
• A picture of the damaged item may be requested. Pictures should be sent to custserv@realflame.com.
Incorrect Order Received
If you received something other than what you ordered, please contact Real Flame Customer Service at
1-800-654-1704 within 48 hours of receiving the item.
Refer to www.realflame.com for our complete return guidelines and policies.
Please register your fireplace for recall notifications, proof of ownership and quality assurance at
https://www.realflame.com/registration.
Real Flame Customer Service
USA: 1-800-654-1704
Canada: 1-800-363-6443
custserv@realflame.com
16

8122019-3-kv
RISQUE DE MONOXYDE DE CARBONE
Cet appareil peut produire du monoxyde de carbone qui n'a pas d'odeur.
Son utilisation dans un espace clos peut vous tuer.
Ne jamais utiliser cet appareil dans un espace clos tel qu'une caravane,
une tente, une voiture ou une maison.
DANGER!
!DANGER !AVERTISSEMENT : USAGE EXTÉRIEUR UNIQUEMENT.
!
!
RISQUES D’INCENDIE ET D'EXPLOSION
En cas de présence d’odeur de gaz :
• Couper l'alimentation en gaz vers
l'appareil.
• Éteindre toute flamme nue.
• Si l'odeur persiste, quitter immédi-
atement l’endroit.
• Après avoir quitté les lieux, appeler
votre fournisseur de gaz ou le service
d'incendie. Si ces précautions ne sont
pas respectées, cela pourrait pro-
voquer un incendie ou une explosion,
pouvant causer des dommages
matériels, des blessures ou la mort.
L'installation et l'entretien doivent être eectués par un installa-
teur qualifié, un service d’entretien ou le fournisseur de gaz.
INSTALLATEUR : Laisser ce manuel avec l'appareil.
CONSOMMATEUR : Conserver ce manuel pour référence
future.
AVERTISSEMENT : Si les informations contenues dans
ce manuel ne sont pas suivies à la lettre, un incendie ou
une explosion pourrait survenir et entrainer des
dommages matériels, des blessures graves ou la mort.
AVERTISSEMENT : Ne pas entreposer et ne pas utiliser
d’essence ou d’autres liquides ou vapeurs inflammables à
proximité de cet appareil ou de tout autre appareil.
Un réservoir de GPL non raccordé pour être utilisé ne
doit pas être entreposé à proximité de cet appareil ou
de tout autre appareil.
140NG Estes Low Square Table De Feu
Manuel du propriétaire

TABLE DES MATIÈRES
Informations importantes sur la sécurité 3
Dangers et avertissements concernant le gaz naturel (GN) 5
Liste des pièces 6
Instructions d’assemblage 7
Instructions avant l’utilisation 10
Entretien et nettoyage 12
Avertissement concernant les araignées et les insectes 13
Conseils et dépannage 14
Liste des pièces techniques 15
Garantie et politiques de retour 16
SPÉCIFICATIONS
Nom du produit
Estes Low Square
Table De Feu
N° de modèle
140NG
Puissance
thermique nominale
60,000 BTU/h
Type de gaz
Gaz naturel (GN)
Approvisionnement en gaz
2
ATTENTION
Veuillez enregistrer votre foyer pour recevoir les notifications de
rappel, les preuves de propriété et l’assurance qualité à l’adresse
https://www.realflame.com/registration.
Approvisionnement en gaz
Système GN installé
professionnellement
Instructions d'allumage 11

INFORMATIONS IMPORTANTES SUR LA SÉCURITÉ
Avertissements généraux
3
Les enfants et les adultes doivent être informés des risques de températures de surface élevées
et doivent rester éloignés pour éviter les brûlures ou que leurs vêtements prennent feu.
Les jeunes enfants devraient être soigneusement surveillés autour du foyer.
Les vêtements ou autres matériaux inflammables ne doivent pas être accrochés au foyer
ou placés sur ou à proximité de l’appareil.
Toute protection ou autre dispositif de protection retiré pour l’entretien du foyer doit être
replacé avant d’utiliser l’appareil.
L'installation et l'entretien doivent être eectués par un service d’entretien qualifié ou le
fournisseur de gaz. Real Flame recommande d’utiliser des professionnels certifiés aux
États-Unis par le National Fireplace Institute® (NFI) en tant que Spécialistes NFI du Gaz.
Un nettoyage plus fréquent peut être nécessaire. Il est impératif que le compartiment de
commande, les brûleurs et les passages de circulation d’air de l’appareil soient
maintenus propres.
Ne pas entreposer et ne pas utiliser d’essence ou d’autres liquides ou vapeurs inflammables
à moins de 7,62 m (25 pi) de cet appareil ou de tout autre appareil.
Ne pas ranger de matériaux combustibles dans le boîtier du foyer.
S’assurer de protéger le tuyau et ses composants de toutes surfaces chaudes. Il est
dangereux de laisser le tuyau entrer en contact avec une surface chaude.
N'utiliser que le tuyau de gaz naturel et le raccord rapide fournis. Le tuyau de gaz naturel et
la prise de connexion rapide de rechange doivent être ceux spécifiés par le fabricant.
Ne pas essayer de débrancher le tuyau de gaz naturel ou la prise de connexion rapide de
l’alimentation en gaz principale lorsque l'appareil est en marche.
Toujours couper l’alimentation en gaz à la vanne d’arrêt et débrancher la prise de connexion
rapide de l’alimentation en gaz principale lorsque l'appareil est en marche.
Conserver toutes les parties du foyer propres, y compris le brûleur et le tuyau. Pour plus
d’informations sur le nettoyage du foyer, consulter la section Entretien et nettoyage de ce
manuel.
Ne pas utiliser ce foyer si une pièce a été submergée. Appeler immédiatement un technicien de
service qualifié pour inspecter l’appareil et remplacer toute pièce du système qui a été submergée.
Ne pas utiliser ce foyer pour la cuisson.
Ne pas verser d’eau dans le foyer.
Ne pas essayer de déplacer ou de ranger ce foyer jusqu’à ce que toutes les pièces soient
froides.
Toujours couper l’alimentation en gaz à la source et débrancher le tuyau lorsque le foyer n’est
pas utilisé.
Toute modification de ce foyer qui n’est pas spécifiée dans le manuel du propriétaire
annulera la garantie du fabricant. Cela comprend l’utilisation de matériaux de remplissage
non approuvés.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

Avertissements d’installation
•
•
•
•
•
•
•
•
Avertissements de préparation
•
•
•
•
Avertissements lors de l’utilisation
•
•
•
•
•
•
•
•
4
INFORMATIONS IMPORTANTES SUR LA SÉCURITÉ
Distance minimale de l’unité aux matériaux combustibles : 121,9 cm (48 po) de tous les côtés.
Ne pas placer pas ce foyer sous aucune structure suspendue ou végétation.
La pression d’entrée normale pour ce foyer est de 7,0 po W.C. (1,74 kPa). La pression d’entrée
maximale est de 10,5 po W.C. (2,61 kPa). La pression d’entrée minimale est de 3,5 po W.C. (0,87 kPa).
Un foyer connecté aux tuyauteries de gaz fixes doit se conformer aux codes locaux ou, en
l’absence de tels codes, au Code national du gaz combustible (National Fuel Gas Code), ANSI
Z223.1 / NFPA 54 ou le Code international du gaz combustible.
Ne pas retirer les pieds du foyer.
Ne pas placer le foyer sur tout ce qui bloque ou scelle l’espace entre le foyer et le sol.
Ne pas fixer en permanence le foyer de quelque manière que ce soit ou à aucune surface.
Ne pas enterrer le tuyau. Il faut pouvoir inspecter visuellement le tuyau avant chaque utilisation.
Ne pas enrouler ou cacher le tuyau sous le foyer. Le tuyau pourrait être endommagé s’il
touche des surfaces chaudes.
Avant chaque fonctionnement, vérifier le tuyau pour s’assurer qu’il n’y a pas d’abrasion,
d’usure ou de dommage. Utiliser un miroir portatif, si nécessaire, pour voir les sections de
tuyau situées sous l’appareil.
Si le tuyau flexible est endommagé, fissuré ou coupé, il doit être remplacé avant d’utiliser le
foyer. Le tuyau doit être remplacé par un tuyau spécifié par Real Flame. Contacter le service
à la clientèle Real Flame au 1-800-654-1704 pour obtenir de l’assistance.
Placer le tuyau hors des sentiers où les gens risquent de trébucher. Ne pas placer le tuyau
dans les endroits où il risque d’être endommagé accidentellement.
Avant chaque utilisation, examiner le brûleur et ses composants pour la présence de saleté et
de débris. Si le nettoyage est nécessaire, utiliser une brosse à tuyau et de l’air comprimé.
Examiner également la zone autour du brûleur. Toutes saletés ou matières étrangères telle que
les toiles d’araignées, les nids, les feuilles, etc., doivent être enlevées. S’il est évident que le
brûleur est endommagé, le foyer ne doit pas être utilisé et le brûleur doit être remplacé.
Contacter le service à la clientèle Real Flame au 1-800-654-1704 pour obtenir de l’assistance.
NE JAMAIS LAISSER ce foyer sans surveillance lorsqu’il est en cours d’utilisation.
Ne pas brûler de combustibles solides, tels que briquettes de charbon de bois, charbon de
bois en bloc, bûches de papier, rebut, feuilles, papier, carton, bois naturel ou traité, ou tout
autre matériau dans ce foyer.
La consommation d’alcool, de médicaments sur ordonnance ou en vente libre peut nuire à la
capacité d’utiliser ce foyer de façon sécuritaire.
Toujours utiliser conformément à tous les codes locaux, provinciaux et nationaux applicables.
Contacter le service d’incendie local pour plus de détails concernant les feux extérieurs.
Ne pas utiliser dans des conditions venteuses. Des vents forts peuvent éteindre la flamme.
Certaines surfaces de ce foyer peuvent devenir chaudes pendant l’utilisation. Faire attention
et ne pas toucher les surfaces jusqu’à ce que l’appareil soit refroidi.
Ne pas essayer de débrancher l'alimentation en gaz du foyer lorsque l'appareil est en marche.
Ne pas s'asseoir sur le foyer.
Table of contents
Languages:
Other Room & Board Outdoor Fireplace manuals
Popular Outdoor Fireplace manuals by other brands

Outsunny
Outsunny 842-230 instruction manual

Sunnydaze Decor
Sunnydaze Decor NB-MS201 Assembly and instruction sheet

FEUERHAND
FEUERHAND TYROPIT user manual

Direct Wicker
Direct Wicker G3R521E owner's manual

Mosaic
Mosaic FSMVPT2042 Assembly instructions & user manual

SNOWJOE
SNOWJOE SUNJOE SJFP35-STN-RM Operator's manual