manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Rosslare
  6. •
  7. Enclosure
  8. •
  9. Rosslare PS-C25TB User manual

Rosslare PS-C25TB User manual

Other Rosslare Enclosure manuals

Rosslare ME-14 User manual

Rosslare

Rosslare ME-14 User manual

Rosslare ME-01P14 User manual

Rosslare

Rosslare ME-01P14 User manual

Rosslare ME-0515M User manual

Rosslare

Rosslare ME-0515M User manual

Rosslare ME-1015 User manual

Rosslare

Rosslare ME-1015 User manual

Rosslare ME-1515 User manual

Rosslare

Rosslare ME-1515 User manual

Popular Enclosure manuals by other brands

Antec Veris Fusion Remote Max Specification sheet

Antec

Antec Veris Fusion Remote Max Specification sheet

ENERMAX iVektor.Q ECA 3371 Series user manual

ENERMAX

ENERMAX iVektor.Q ECA 3371 Series user manual

Lindy 43095 user manual

Lindy

Lindy 43095 user manual

SICK C4000 Select operating instructions

SICK

SICK C4000 Select operating instructions

Geeek A60 PLUS installation guide

Geeek

Geeek A60 PLUS installation guide

OVE SYDNEY 48 installation manual

OVE

OVE SYDNEY 48 installation manual

SilentiumPC Armis AR5 Hardware installation

SilentiumPC

SilentiumPC Armis AR5 Hardware installation

Pulsar 17/TRP80/DSPR Assembly instructions

Pulsar

Pulsar 17/TRP80/DSPR Assembly instructions

MSI MPG SEKIRA 500X quick start guide

MSI

MSI MPG SEKIRA 500X quick start guide

Antec Dark fleet DF-10 user manual

Antec

Antec Dark fleet DF-10 user manual

Peavey DS 1502 Specifications

Peavey

Peavey DS 1502 Specifications

D-Link ShareCenter Pro DNS-1550-04 user manual

D-Link

D-Link ShareCenter Pro DNS-1550-04 user manual

Rosewill RX82-U(JBOD) user manual

Rosewill

Rosewill RX82-U(JBOD) user manual

QNAP SAS JBOD CLI 1.0 user guide

QNAP

QNAP SAS JBOD CLI 1.0 user guide

GAMDIAS Talos P1 Quick installation guide

GAMDIAS

GAMDIAS Talos P1 Quick installation guide

Auvs KR615 user manual

Auvs

Auvs KR615 user manual

Antec AR300 user manual

Antec

Antec AR300 user manual

CommScope FDH 3000 user manual

CommScope

CommScope FDH 3000 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PS-C25TB
Power Managment Enclosure with built in Secure Relay I/O Module
Installation Manual
1. Introduction
The PS-C25TB is a Power Management Enclosure for use with
Rosslare's Secure Stand-Alone Controller Unit. It is a combination of
the ME-0515M Multipurpose Power Management Enclosure and the
MD-25TB Secure Relay I/O Module preassembled for installation
convenience. The secure relay provides power to the Controller Unit.
The Controller Unit communicates with the secure module through a
Rosslare proprietary protocol, providing instructions to activate the
lock/auxiliary relays and a built-in sounder (with bell and siren
tones). The secure module also communicates the REX input status
to the Controller Unit. A red LED indicates the secure module power
status. The secure module includes removable terminal blocks for
ease of wiring and installation.
The enclosure features a switch-mode power supply (SMPS) that
outputs power to the PM-05 power management module.
The PM-05 power management module has two independent power
channels with an isolated PTC (self-resetting fuse). One channel
powers the MD-25TB while the other channel may be used to power
a lock. Battery backup is available. When AC power fails, the PM-05
instantaneously (UPS) switches power over to a stand-by sealed
lead acid (SLA) battery (not included) charged by a built-in battery
charger.
Figure 1: PS-C25TB
2. Technical Specifications
2.1 Electrical Characteristics
SMPS
Input
110 –240 VAC, 50/60 Hz, 1.5 A
Output
15 VDC, 4 A
PM-05
Input
15 VDC, 4 A
DC Output
14.5 VDC, 2 A (CH1/CH2)
Battery Charge
current
1.5 A
MD-25TB
Input
12 VDC, 2 A
Output
12 VDC, 0.25 A (PCB maximum output
current)
5 A Form C, SPDT Relay
Auxiliary Output
Max Switched Current: 5 A
Max Switched Voltage: 150 VDC or 300 VAC
UL Rating: 5 A at 30 VDC or 5 A at 125 VAC
Speaker Output
0.25 W, 8 Ω(minimum)
LED indicators
Power status:
•Red –power on
•Off –power off
2.2 Environmental Characteristics
Operating Environment
Indoor
Operating Temperature Range
-10°C - 50°C (14°F - 122°F)
Operating Humidity Range
0% - 85% (non-condensing)
2.3 Physical Characteristics
Dimensions
(H x W x D)
228 x 224 x 84 mm
Weight
2.21 kg (4.87 lb)
3. Installation
3.1 Mounting
Make sure the mounting location is a flat surface.
To mount the ME-0515M:
1. Drill holes in the wall using the enclosure back cover holes as a
guide (Figure 2).
2. Insert masonry anchors into the drilled holes.
3. Mount the enclosure on the wall.
4. Once the PC-C25TB is mounted, it can house a controller and an
expansion.
Figure 2. Enclosure Drill Holes
2
3.2 Wiring
Refer to the wiring diagrams below.
The MD-25TB auxiliary output maximum current is 5 A. But
the PM05 output max current is 2 A.
If the lock or auxiliary load current is more than 1.5 A, you
must use an external power supply (see Figure 6).
To wire the unit:
1. Connect the AC power cable to the PS-C25TB.
2. Connect the Controller Unit power input to the SECURED
CONTROLLER +V and (-) terminals.
3. Connect both lock outputs to the LOCK NC or NO terminals as
required.
4. [OPTIONAL] Connect the auxiliary relay.
5. [OPTIONAL] Connect the battery terminal to PM05 BAT 12VDC
terminals (battery leads included).
Do not use panic hardware with this device.
Figure 3. General Wiring Diagram
Figure 4. Secure Stand-Alone Controller Unit Wiring Diagram
Figure 5. Lock and REX Switch Wiring Diagram
Figure 6. Auxiliary Load Wiring Diagram
4. Maintenance
For proper operation, the unit should be tested at least once a year.
4.1.1 Output Voltage Test
1. Check DC output for proper voltage level under normal load
conditions.
4.1.2 Battery Test
1. Check specified voltage at the battery terminal and board BAT
12VDC terminals under normal load conditions.
2. Verify that the battery is fully charged and make sure there is no
break in the battery connection wires.
Maximum charging current under discharge is 1.2 A.
Expected battery life is 5 years. However, it is recommended
to change batteries within 4 years if needed.
Dispose of used batteries according to manufacturer ’s
instructions.
3
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the
Quick Links section on the ROSSLARE website at
www.rosslaresecurity.com.
Rosslare considers any use of this product as agreement to the
Warranty Terms even if you do not review them.
Contact Information
United States and Canada
Rosslare Security Products, Inc.
Southlake, TX, USA
Toll Free: +1-866-632-1101
Local: +1-817-305-0006
Fax: +1-817-305-0069
support.na@rosslaresecurity.com
Europe
Rosslare Israel Ltd.
Rosh HaAyin, Israel
Tel: +972-3-938-6838
Fax: +972-3-938-6830
support.eu@rosslaresecurity.com
Latin America
Rosslare Latin America
Buenos Aires, Argentina
Tel: +54-11-4001-3104
support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd.
Shenzhen, China
Tel: +86-755-8610-6842
Fax: +86-755-8610-6101
support.cn@rosslaresecurity.com
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd.
Kowloon Bay, Hong Kong
Tel: +852-2795-5630
Fax: +852-2795-1508
support.apa[email protected]
India
Rosslare Electronics India Pvt Ltd.
Tel/Fax: +91-20-40147830
Mobile: +91-9975768824
sales.in@rosslaresecurity.com
CERT
ISO 9001
ISO 14001
0706-0960701+03