Rotech SafePass RD6 User manual

ar.
How to install the radar detector
Use a power adapter output 8-4OVDC IA.
When using a gate for power supply, please ensure that the output current is not less than
200ma.
When applied to lanes, the best height between the radar center and the ground is 50-60cm.
The distance between the center of the radar and the fence is not less than 25cm.
The radar installation surface should be perpendicular to the ground and be fixed solid.
The ground within the detection range should be flat without any obstacles. The direction of the
traffic should be at right angle to this radar.
The meaning of the indicator light and function menu (red LED )
Menu Setting function Default (factory)
1 Detection distance: The reading corresponds to a distance of 1-6 meters 3 meters
2 Sensitivity: Reading value 1-Low 2-Middle 3-High
It is used to set the factory default value when the reading is 6
2 (middle)
3 Gate dosing speed: reading 1-6 corresponds to time 2-12 seconds 6 seconds
4 When Relay delay : Reading 0-6 corresponding time 0-6 second 0 second
6 Setting: 1-Straight bar barrier 2-fence barrier 3-plus signal
1 (straight bar
barrier)
Press and hold the function key for 8 seconds to enter the menu mode.
LED indicated light (3pcs RED led)
Function Menu
Menu
1
ON
OFF
OFF
Me
nu 2
OFF
ON
OFF
Me
nu 3
OFF
OFF
ON
Menu 4 ON OFF ON
Menu 6 ON ON ON
Menu 1: Detection distance settings
(The indicator light is the blue LED, the indicator LED has three states: 1. ON 2. FLASH 3. OFF)
Menu 1
1 meter ON OFF OFF
1.5 meter FLASH OFF OFF
2 meters OFF ON OFF
2.5 meter OFF FLASH OFF
3 meter OFF OFF ON
3.5 meter OFF OFF FLASH
4 meter ON OFF ON
4.5 meter FLASH OFF FLASH
5 meter OFF ON ON
5.5 meter OFF FLASH FLASH
6 meter ON ON ON

Menu 2: Sensitivity content details
(The indicate light was the blue LED, The indicator LED has three states: 1. ON 2. OFF)
Menu 2
Low sensitivity ON OFF OFF
Middle
sensitivity
OFF ON OFF
High sensitivity OFF OFF ON
Factory default FLASH FLASH FLASH
Menu 3: Details of closing speed
(The indicate light was the blue LED, the indicator LED has three states: 1. ON 2. FLASH 3. OFF)
Menu 3
2 second ON OFF OFF
3 second FLASH OFF OFF
4 second OFF ON OFF
5 second OFF FLASH OFF
6 second OFF OFF ON
7 second OFF OFF FLASH
8 second ON OFF ON
9 second FLASH OFF FLASH
10 second OFF ON ON
11 second OFF FLASH FLASH
12 second ON ON ON
Menu 4: The relay content details
(The indicate light was the blue LED, the indicator LED has two states: 1. ON 2. FLASH 3. OFF)
Menu 4
0 second OFF OFF OFF
1 second ON OFF OFF
2 second OFF ON OFF
3 second OFF OFF ON
4 second ON OFF ON
5 second OFF ON ON
6 second ON ON ON
Menu 6: Barrier or function content details
(The indicate light was the blue LED, The indicator LED has three states: 1. ON 2. OFF)
Menu 6
Straight bar barrier OFF OFF OFF
Fence pole barrier ON OFF OFF
Pole count OFF ON OFF

How program and save the parameters
Step 1: Press the function key (do not release) until the menu number to be set is selected and
release the key, the corresponding parameter light will be on.
Step 2: Edit parameters: Change the current parameter by function key.
Step 3: Save parameters: Press the function key momentarily, and then release. The red
indicator lights I, 2 and 3 flashing at the same time. The parameters will be changed and saved.
Quick setting
1. Straight lane application settings
Step 1: Set the barrier mode to straight bar barrier (Menu 6)
Step 2: Set the detection distance (Menu 1)
2. Fence pole barrier application settings
Step 1: Set the barrier mode to fence mode (Menu 6)
Step 2: Set the detection distance ( Menu 1)
Step 3: The brake speed is determined to be 1 second (Menu 3)
3. Trigger mode application settings (only need 3 step)
Step 1: Set the barrier mode to trigger mode (Menu)
Step 2: Set the detection distance (Menu 1)
Step 3: Set the reply output method (Menu 5)
Optimize radar detector settings (select setting items)
1. Sensitivity setting: The recommended setting for vehicles is medium or low, and the
pedestrian passage setting is medium or high. You can set one in the middle and the other as
high or low.
2. Pedestrian and vehicle distinction setting: it is strongly recommended to set the distinction
between pedestrian and vehicle in non-necessary situations. Vehicle passage or pedestrian
passage should be set to "No distinction between pedestrians and vehicles". Otherwise. Please
set the " distinction the pedestrian and the vehicle" To prevent accidents caused by non-
vehicle passing.

How to debug on site?
Straight lane mode: After the barrier pole is raised, the palm of the hand triggers the radar at a
close range, and the gate will automatically close after removing. Within the set detection
distance, the pole reverses when the human body approaches the pole. The response speed of
the radar can be adjusted.
Trigger mode: Refer to the debugging method of the straight lane mode
Connection:
Color: Function
Red: Power supply input +10-24VDC
Black: Power supply input GND
Yellow: Set button input port
White: Input GND
Orange: Relay NC
Brown: Not used
Blue: Relay COM
Green: Relay NO
General troubleshooting
The radar is triggered by the fence itself during opening or closing
Check whether the distance between the radar and the center of the fence is in accordance with
the requirements and whether the radar installation surface is perpendicular to the fence. Please
adjust the installation position or add a 2-4mm spacer to the side of the radar close to the fence.
Whether the set opening speed is greater than the actual closing speed.
Whether there is no distinction between people and vehicles, if it is necessary to set the distinction
between people and vehicles, the sensitivity can be lowered by one level.
Radar output has not been reset
The set distance is greater than the lane or a foreign object on the ground is detected, or the radar
is not installed vertically.
If you still can't solve the problem after troubleshooting, please enter menu 2 (when the 3 blue lights
flash at the same time, press the function key and go straight to "Radar Initialization"). After the
initialization is completed, please power on again.
The three lights are always on after the radar is powered on
The radar is initialized, and it still doesn't work after repeated restarts, please return to the factory for
inspection
The indicated blue light number I and number 3 flash
When the radar judges that the gate is triggered when the gate is closed, or there is a reversal
signal at the edge of the beam, the radar cannot distinguish whether it is a fence or a vehicle. The
gate will be closed after the gate is opened or there is no lane passing after the signal disappears.
It is a safety mechanism to prevent lowering on the rear of the vehicle and does not need to be
dealt with.