2 DE1151 SPY 1, 2, 3, 4 Installation Instructions
INSTALLATION
Suitable for wall or ceiling installation, and available with both a
collar and a front or rear mounting plate, depending on the model.
ENVIRONMENTAL
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Storage Temperature: -20°C to 60°C (-4°F to 140°F)
RFl Protection: Greater than 10 V/m to 1000MHz
PHYSICAL
Dimensions: Diameter: 19 mm (0.75 in) Length: 70 mm (2.75 in)
Weight: 30 g (1.1 oz)
Color: White
3. INSTALLATION
3. INSTALLATION3. INSTALLATION
3. INSTALLATION
ATTENTION: Whichever model of SPY PIR detector you are
installing, please observe the following:
1. Never touch the lens. Whenever you are handling the
detector, hold it firmly by the collar, mounting plate, or sides.
2. Splice or solder the wires from the control panel to the SPY
detector. Do not attach by only twisting wires together.
3. Insulate each wire individually. Do not permit uninsulated
wires to touch each other.
4. During the wiring operation, be careful to place the detector
so that the lens is protected.
5. Do not open the detector from either the front (lens end) or
the back (wire end).
FAILURE TO OBSERVE THESE PROCEDURES MAY
INVALIDATE YOUR WARRANTY.
3.1 Choosing the Right Loc tion
SPY PIRs can be installed in a wall or ceiling and are available
with both a collar and a front/rear mounting plate. Three of the
models (SPY 1, 2 and 4) can be installed with the mounting plate
in the front or rear of the detector unit, as required. The choice of
method depends upon the type of wall or ceiling and the degree
to which the detector should be unnoticed.
•SPY Models SPY 1, SPY 2 and SPY 4 are provided with both
a collar and a front/rear mounting plate.
•SPY 3 is provided with a fixed mounting plate for front- of-the-
wall installation.
1. Select the mounting location so that the expected motion of
an intruder will cross the coverage pattern.
2. When wall mounted, the SPY should be installed parallel to
the floor for maximum coverage. Recommended mounting
height: between 80 cm and 1.35 m (2.5 and 4.5 ft).
3. The curtain detector SPY 4 can be mounted in the ceiling or in
the wall. When mounting in the wall it should be installed
parallel to the floor. Maximum ceiling height: 4 m (12 ft).
4. Always install the unit into a firm and stable surface, and
assure that there are no moving objects within its field of view.
Remember: Passive infrared detectors are sensitive to
changes in infrared energy caused by an object moving
across the unit's field of view. Detection depends on the
difference between the amount of infrared energy
transmitted by the moving object and the temperature of the
background.
It is therefore recommended that the detector be aimed toward
the coolest place in the area to be protected, in order to obtain
maximum sensitivity in installations where high ambient tempera-
tures are expected. Do not aim the detector toward areas
containing hot water pipes or windows, which might cause
problems in the operational efficiency of PIR detectors.
BEFORE YOU START:
Do not touch the lens.
Solder or splice wire connections.
Insulate wires individually so that they cannot touch.
3.2 Inst ll tion with Coll r
(MODELS SPY 1 and 2)
1. Drill a 22 mm (7/8 in.) hole in the wall.
2. Hold the detector unit by the sides. Carefully put the collar on
the detector and adjust its
position so that the front of
the detector and the collar
are aligned (Fig. 1).
3. Fish the wiring from the
control panel through the
hole and connect to the
detector unit as described
under WIRING.
4. Feed the wiring into the
prepared hole.
5. Orient the detector unit so
Figure 1 - Installation with
Collar, Models SPY 1, SPY 2
that the mark on the front faces up (Fig. 1).
6. With your fingers on the outer edge of the collar, push the
detector unit, rear end first, into the hole until the retaining
collar is seated securely.
3.3 Front-of-W ll Inst ll tion
(MODELS SPY 1 and 2)
1. Drill a 24 mm (15/16 in) hole in the wall.
2. Hold the detector unit by the sides and put it, lens end first,
into the mounting plate (Fig. 2A).
3. Adjust the detector unit in the mounting plate so that the front
of the detector extends a minimum distance from the wall.
4. Place the locking ring over the rear end of the detector unit
and move it over the tabs of the locking plate until the detector
unit is absolutely stable in the mounting plate (Fig. 2A).
5. Fish the wiring from the control panel through the hole and
connect to the detector unit as described in WIRING.
6. Feed the wiring into the prepared hole.
7. Prepare the mounting plate screw holes on a horizontal line,
making sure that the mark on the front of the detector unit is
facing up (Fig. 2B).
8. Insert the detector unit, rear end first, into the hole with the
mark on the front facing up (Fig. 2B) and secure the mounting
plate to the wall with the screws provided.
Figure 2 (A & B) - Front of Wall Installation, Models SPY 1 and 2
3.4 B ck-of-W ll Inst ll tion
(Models SPY 007.1, 007.2)
1. Drill a 19 mm (3/4 in.) hole in the wall.
2. Hold the detector unit by the sides and put it, lens end first,
into the mounting plate (Fig. 3A).
3. Adjust the detector unit in the mounting plate according to the
thickness of the wall. When installed, the lens end of the
detector should extend about 1 mm (0.05 in.) from the wall.