SAFETY REGULATIONS
In order to avoid risks for the user’s and other
people’s safety, as well as annulling the warranty,
it is advisable to read the suggestions in this section
for correct use of the product.
• Do not expose the unit to rain or use it in
locations with a high humidity level.
• Ensure that no liquids or solid objects
accidentally enter the unit; should this occur,
stop using the unit and contact OUTLINE or
specialist staff.
• When connecting the unit, ALWAYS check
ground connection as required by technical
and safety norms.
• If the original connector cable is worn or
damaged, it must be replaced with another of
the same type (in perfect condition).
• Carry out connections in an orderly manner,
only allowing access to experienced specialist
staff.
• The unit must only be opened and/or repaired
by specialist staff.
• For any requirements of a technical nature,
contact OUTLINE or authorized staff.
• The unit is dedicated to moving heavy or bulk
objects. For this reason, it must be used under
the supervision of experienced personnel.
DISPOSAL OF WASTE MATERIALS
Your product is designed and manufactured
with high quality materials and components,
which can be recycled and reused. When
this crossed-out wheeled bin symbol is attached to
a product, it means the product is covered by the
European Directive 2012/19/EU and subsequent
amendments. This means that the product must
NOT be disposed of with other household-type
waste. It is the users’ responsibility to dispose of
their waste electrical and electronic equipment by
handing it over to an approved reprocessor. For
more information about where you can send your
equipment for recycling, please contact your local
distributor. The correct disposal of your old product
will help prevent potential negative consequences
for the environment and human health.
CONFORMITY AND WARRANTY
All the Outline electro-acoustic and
electronic devices are in conformity with
the provisions of EC/EU directives (as
stated in our CE declaration of conformity).
The CE declaration of conformity is attached to the
product warranty certificate and is shipped with
the product.

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
3
SYSTEM DESCRIPTION
The target of this device is to identify macroscopic
damages (like disconnected wires, blown coils,
etc...) for each way of the Outline speakers quickly
and without the need of an external mains power.
In order to perform the measure you have to
connect a single speaker to one connector on the
device via a short link cable, select the measurement
preset and push the “MEASURE” button. The result
is shown on the display and via the coloured LEDs
for each active way.
UNPACKING
After unpacking the device, check very carefully
for any damage. If any damage is found, please notify
your dealer.
It is advisable to keep the packaging for use in the
event of the unit being transported in the future.

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
4
FRONT PANEL
MEASURE
BACKLIGHT
SHORT CIRCUIT
FAULT
OK
LK8 CONNECTOR
NL4 CONNECTOR
A/B C/D E/F G/H
1+/1- 2+/2-
A FASTQC-LS
SHORT CIRCUIT
FAULT
OK
LK8 CONNECTOR
NL4 CONNECTOR
LOUDSPEAKER FAST QUALITY CONTROL
MEASURE
BACKLIGHT
SHORT CIRCUIT
FAULT
OK
LK8 CONNECTOR
NL4 CONNECTOR
A/B C/D E/F G/H
1+/1- 2+/2-
A FASTQC-LS
SHORT CIRCUIT
FAULT
OK
LK8 CONNECTOR
NL4 CONNECTOR
LOUDSPEAKER FAST QUALITY CONTROL
OUTLINE
Spk Tester
1
2
3 4
7
8
9
10
5
6
• 1) POWER EXCLUSION: connects and
disconnects the battery. To turn on the
device push one of the four buttons; about
thirty seconds after the last activity the
device automatically switches off (no power
consumption). In order to reactivate it press
one of the four buttons;
• 2) 9V BATTERY HOUSING: standard single 9V
battery housing;
• 3 & 4) CONNECTORS: two connectors are
available (one NL4 and one LKI8) to connect the
loudspeaker to test;
• 5) DISPLAY: shows the name of the selected
preset, the name of each way and, during
the test phases, more information about the
detected issues;
• 6) REPORT: test results for each way are also
shown via coloured LEDs.;
• 7) “MEASURE” BUTTON: run the measurement;
• 8) “BACKLIGHT” BUTTON: enables and
disables the display backlight. Ten seconds
after the last use, the backlight turns off
automatically; to reactivate it press one of the
buttons.
• 9 & 10) SCROLL BUTTONS: used to scroll the
list of the measurement presets.

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
5
1. Power up: after checking the presence of the
battery and its good condition switch the power
exclusion button(1) in the active position.
Push any button to activate the device.
(7/8/9/10).
During the start-up the display shows the
firmware version.
Afterwards the temperature measured by
the internal sensor and the estimated battery
charging level are shown. In this configuration
it is possible to change the intensity of the
backlight via the two arrow buttons. (9 and 10)
2. Measurement preset selection: push the
“MEASURE” button(7) to open the list. Scroll
it with the arrow buttons (9 and 10) in order
to select the preset corresponding to the
enclosure to test. The display will show the
name of the speaker in the first row and the
name of each way in the second one, as is
reported in the label attached to each Outline
speaker.
3. Measuring: push the “MEASURE” button(7).
You will hear a “click” and you will see the
results of the test. For each way the resistance
is measured and compared to the limits saved
in the measurement preset. If the detected
value is within the limits, the green LED of
the corresponding way will light up, otherwise
one of the two red LEDs will come up and
the loudspeaker will have to be tested more
thoroughly. In addition the display will alternate
the name of the way with the result of the test.
The display will show:
Ok
Value within the limits
OpC
Open Circuit
LoR
Low Resistance
HiR
High Resistance
4. Execution of a subsequent test: push again the
“MEASURE” button(7).
5. Selection of a different preset: push the arrow
buttons (9 and 10) in order to scroll the list and
repeat step 3.
NOTE: via the “No One” preset you can measure
the resistance of each way and the display will
show the numerical values.
DEVICE USE

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
6
OVERALL DIMENSIONS
46140 235
168
106

OUTLINE S.R.L.
Via Leonardo da Vinci, 56
25020 Flero (Brescia) Italy
Tel.: +39 030.3581341
Fax +39 030.3580431
www.outline.it
7
NOTES

Outline carries out on-going research for product improvement. New materials, manufacturing methods
and design upgrades are introduced to existing products without prior notice as a routine result of this phi-
losophy. For this reason, any current Outline product may differ in some aspect from its description, but will
always equal or exceed the original design specifications unless otherwise stated.
© Outline 2021
Operating manual product code: Z OMFASTQC
Release: 20211015
Printed in Italy
Table of contents
Popular Controllers manuals by other brands

BIFFI
BIFFI ALGAS Installation, operation and maintenance manual

Beck
Beck 14-100 instruction manual

CAMDEN
CAMDEN WC13 Series installation instructions

Alcor
Alcor AU9381 Technical reference manual

American Megatrends
American Megatrends MegaRAC MG9070 datasheet

vacuubrand
vacuubrand CVC 3000 Instructions for use