  9. Rowe ADCP User manual

Rowe ADCP User manual

Quick Start Guide
ADCP Communicaon and Recording
1Connect the underwater
cable to the ADCP. 2Connect the power and serial
communicaon to the under-
water cable. Connect the USB
serial communicaon to the
computer. Plug the power
into the wall.
34
5Congure the ADCP. Then click
the “START PING” buon to
begin collecng data.
Common Commands
CDEFAULT—Set Default sengs
CWS—Salinity
0=Fresh water
35 = Salt water
CHO—Heading oset or declinaon
CEI—Data Output ming
Prole Range
CWPBL—Blank
CWPBN—Number of Bins
CWPBS—Bin Size
CWPBB—Set Lag Length
CSAVE– Save all sengs
START– Start pinging
Note:
Use the predicon model in Pulse to verify all com-
mands meet your requirements.
Home->ADCP Ulies->ADCP Predicon Model
6Once the ADCP begins to stream
data to the terminal, click the
VIEW buon on the navigaon
bar to view the data.
Open Pulse, go to TERMINAL in
top right corner. Set the serial
port and baud rate. By default
the ADCP is 115200 8N1. Then
click the BREAK buon to verify
communicaon.
7To record data, click the RECORD
buon on the top navigaon bar.
Data will record to C:\RTI_Capture
Rev: C
858.842.3020 | www.rowetechinc.com | support@rowetechinc.com
Install Pulse. Install any win-
dows drivers for the USB –To-
Serial adapters if required. The
soware and drivers can be
found on the USB memory
sck.
Power
RS-232
RS-485
`
Rev: C
858.842.3020 | www.rowetechinc.com | support@rowetechinc.com
Predicon Model
The predicon model will help you create a de-
ployment. The things to keep in mind for a de-
ployment are the:
 Maximum Measureable Velocity
Boat Speed + Water Speed
 Standard Deviaon of Velocity
 Baery Consumpon (Number of Baeries)
 Data Consumpon (SD Memory Card)
 Prole and Boom Track Range
ADCP Ulies->ADCP Predicon Model
BREAK or Wake-Up Statement
Copyright (c) 2009-2015 Rowe Technologies Inc. All rights reserved.
Direct Reading
DP1200
SN: 01200000000000000000000000000208
FW: 00.02.82 Feb 19 2016 13:58:12
ADCP Power
Max Voltage: 36v
Min Voltage: 12v
Min Current: 3a
Maintenance
 Baeries
Replace the baeries when dead. A
dead baery will read a voltage of 15v
to 17v under load.
 Desiccant
Desiccant should be replaced every
year.
 O-Rings
O-Rings should only be replaced if
damaged. When sealing the housing
make sure not to pinch or cut an O-
Ring.
ADCP Baeries
Baeries are not inially connected when shipped.
When ready to deploy, connect the baeries by con-
necng the baery connectors to the available power
connectors on the pigtail within the housing.
When reassembling the endcap, ensure the o-ring is
placed properly in the groove. Aer sealing the
endcap to the housing, ensure a proper seal. Slide a
paper against the opening of the endcap and housing
and make sure the paper does not touch the o-ring.
Voltage: 28v-30v 38 C-cell baeries
Fuse: 5a
Quick Start Guide
ADCP Hardware and Conguraon
ADCP Baud Rate
Default: 115200 8N1
To change the RS-485 baud rate to
921600, send the command:
C485B 921600
GPS Heading
Due to magnec interference from
the environment, the internal com-
pass may not be useable. A GPS
can be connected directly to the
ADCP through the RS-232 port of
the ADCP’s underwater cable. Then
set the baud rate of the GPS using
the command C232B. Then send
the command CHS 2 to use the GPS
compass.
C232B 19200
CHS 2

Other manuals for ADCP

1

Popular Sonar manuals by other brands

Lowrance Traditional Installation

Lowrance

Lowrance Traditional Installation

Lowrance X71 Installation and operation instructions

Lowrance

Lowrance X71 Installation and operation instructions

Lowrance Elite 5X DSI Operation manual

Lowrance

Lowrance Elite 5X DSI Operation manual

Furuno CSH-5LMARK-2 installation manual

Furuno

Furuno CSH-5LMARK-2 installation manual

Simrad SU90 Operator's manual

Simrad

Simrad SU90 Operator's manual

Lowrance X510C Operation instructions

Lowrance

Lowrance X510C Operation instructions

Furuno CH-28 Operator's manual

Furuno

Furuno CH-28 Operator's manual

deeper START manual

deeper

deeper START manual

Simrad SU90 Harbour Acceptance Test

Simrad

Simrad SU90 Harbour Acceptance Test

Sonic KCS-5200 Operation manual

Sonic

Sonic KCS-5200 Operation manual

Simrad FS70 - Operator's manual

Simrad

Simrad FS70 - Operator's manual

Furuno CH-24 installation manual

Furuno

Furuno CH-24 installation manual

Furuno FSV-84 installation manual

Furuno

Furuno FSV-84 installation manual

Furuno CH-500 Operator's manual

Furuno

Furuno CH-500 Operator's manual

Eagle FISHMARK 640C Installation and operation instructions

Eagle

Eagle FISHMARK 640C Installation and operation instructions

Furuno CSH-7 installation manual

Furuno

Furuno CSH-7 installation manual

Kongsberg M3 Sonar instruction manual

Kongsberg

Kongsberg M3 Sonar instruction manual

Eagle FishMark 500C Installation and operation instructions

Eagle

Eagle FishMark 500C Installation and operation instructions