Royal Exclusiv AutoSwitch ON/OFF Manual

Operating and maintenance instructions for AutoSwitch ON/OFF
For all switchable outlets with capacitive sensor and delay release
ENG
v1.0
Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
Operating and maintenance instructions for AutoSwitch ON/OFF
For all switchable outlets with capacitive sensor and delay release
Important Notice
Please read this manual carefully before you install the device. We recommend not to proceed the installation of the
device until you read the manual. This prevents any questions and problems that might occur in installation process. As
soon as you power-on the device for the rst time, you agree that you read and understood this manual. In doubt or if
anything is unclear please contact your supplier/vendor or dealer before you start-up the device.
0.1 Foreword
The capacitive sensor of the switchable outlet recorded
contact-free electro-metals, almost all plastics, glass, ce-
ramics, wood, paper, oils, fats, water and all aqueous ma-
terials. The sensor is equipped with a NC- and C- contact,
which supplied to the socket with voltage / or which sepa-
rates from the voltage.
0.2 Packaging content
- Socket unit with relay
- Connected cable for the power plug
- Connected sensor
- Slide of sensor with plastic knurled screw to
xing of the slide
- Bar to the secure the slide and sensor on the
tank to be monitored
Bars are avaibale in3 different lengths 320, 250, 160mm
0.3 Commissioning
Please see the switchable socket with the capacitive sen-
sor from the packaging and check the product for any ship-
ping damage must appear immediately within 24 hours, at
the competent dealer.
The switchable socket with capacitive sensor is fully pre-
installed and can immediately on a lter sump, etc. to be
installed. !! Max load: 2500 Watts!! The maximum dis-
tance for the function of the senor is 8mm!
0.4 Operating and display elements
Self explanatory. The LEDs shows the status:
The green LED indicates whether there is voltage
The yellow LED shows whether the relay is working
The red LED indicates whether the sensor has tripped
The delay/relay can completely with mode Rel. on / / Rel.
off on or be turned off.
The delay can be controlled either rough (grob) or ne
(fein).
0.5 Installation with the help of the carriage
The supplied slide and bar installed as follows. Super-
glue, mirror tape or double-sided tape can be used for
xing the rail where to monitored containers.
0.6 Maintenance
The operation of the device is maintenance-free. For
proper functioning, it is worth noting:
The active surface and if necessary a freedom from de-
posits and foreign bodies are free to keep.
0.7 Setting non-contact sensor
Please note the following pages.
Bedienungsanleitung
Kapazitive Sensoren
KQ6
DE
80003301 / 00 09 / 2013

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
3
UK
1 Preliminary note
1.1 Symbols used
•Operating elements are indicated as follows:
Example: [OUT OFF] = Button “OUT OFF“�
•An instruction is indicated by “►“.
Example: ► Mount the unit as shown.
•A reaction to the action is indicated by “>“�
Example: > Yellow LED on�
Important note
Non-compliance can result in malfunctions or interference�
Information
Supplementary note�
2 Safety instructions
•Please read the product description prior to set-up of the unit� Ensure that the
product is suitable for your application without any restrictions�
•The unit conforms to the relevant regulations and EC directives�
•Improper or non-intended use may lead to malfunctions of the unit or to
unwanted effects in your application�
•That is why installation, electrical connection, set-up, operation and
maintenance of the unit must only be carried out by qualified personnel
authorised by the machine operator�
4
3 Functions and features
•capacitive sensor used as level or proximity sensor
•detects without contact metals, almost all plastics, glass, ceramics, wood,
paper, oils, greases, water and all hydrous materials and indicates their
presence by providing a switched signal
•automatic adjustment to the medium to be detected by means of programming
buttons
•in level applications the sensor detects the medium through the tank wall (only
suitable for non-metallic tanks)
3.1 Application examples

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
4
3 Functions and features
•capacitive sensor used as level or proximity sensor
•detects without contact metals, almost all plastics, glass, ceramics, wood,
paper, oils, greases, water and all hydrous materials and indicates their
presence by providing a switched signal
•automatic adjustment to the medium to be detected by means of programming
buttons
•in level applications the sensor detects the medium through the tank wall (only
suitable for non-metallic tanks)
3.1 Application examples
7
UK
4.2 Use as proximity sensor
4.2.1 Installation and installation remarks
without mounting adapter with mounting adapter
2
1
33
1
2
1: sensing face
2: programming buttons
3: plastic plate
Sn: nominal sensing range (see data sheet)
A: distance = 8 mm
B: width of the mounting adapter = 36 mm
►Align the sensing face (1) to the object� Make sure that the programming but-
tons (2) remain accessible�
►Adhere to the indicated minimum distances to metallic objects opposite and
beside the sensor (free space)�
►Non-metallic objects (e�g� plastic fixtures) are allowed within the lateral free
space�
►Fix the sensor with appropriate fixing screws to the designated location�
►If the sensor is installed behind a plastic plate (3), the object will be detected
through the wall� Depending on the material used and the wall thickness the
sensor characteristics might change slightly� Do not use conductive plastics! If
possible, use thin walls�

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
8
4.2.2 Minimum distances
Installation of several sensors of the same type
Sn: nominal sensing range (see data sheet)
A: sensor distance 50 mm
4.2.3 Sensor bore hole dimensions
3,2
13,4
4,3
4.3 Notes on laying of the connection cable
►Lay the cable as straight as possible and do not coil it�
►If necessary, cut the cable to the required length�
5 Electrical connection
The unit must be connected by a qualified electrician�
The national and international regulations for the installation of electrical
equipment must be adhered to�
►Disconnect power
►Connect the unit
7
UK
4.2 Use as proximity sensor
4.2.1 Installation and installation remarks
without mounting adapter with mounting adapter
2
1
33
1
2
1: sensing face
2: programming buttons
3: plastic plate
Sn: nominal sensing range (see data sheet)
A: distance = 8 mm
B: width of the mounting adapter = 36 mm
►Align the sensing face (1) to the object� Make sure that the programming but-
tons (2) remain accessible�
►Adhere to the indicated minimum distances to metallic objects opposite and
beside the sensor (free space)�
►Non-metallic objects (e�g� plastic fixtures) are allowed within the lateral free
space�
►Fix the sensor with appropriate fixing screws to the designated location�
►If the sensor is installed behind a plastic plate (3), the object will be detected
through the wall� Depending on the material used and the wall thickness the
sensor characteristics might change slightly� Do not use conductive plastics! If
possible, use thin walls�

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
8
4.2.2 Minimum distances
Installation of several sensors of the same type
Sn: nominal sensing range (see data sheet)
A: sensor distance 50 mm
4.2.3 Sensor bore hole dimensions
3,2
13,4
4,3
4.3 Notes on laying of the connection cable
►Lay the cable as straight as possible and do not coil it�
►If necessary, cut the cable to the required length�
5 Electrical connection
The unit must be connected by a qualified electrician�
The national and international regulations for the installation of electrical
equipment must be adhered to�
►Disconnect power
►Connect the unit
9
UK
5.1 Wiring
p-switching (type ���FPKG��� or ���FPOG���)
n-switching (type ���FNKG��� or ���FNOG���)
BN = brown, BK = black, BU = blue
BN = OUT / IO-Link 4: OUT / IO-Link
5.2 Unit versions with auto-detect
On power up, unit types with auto-detect (types ���FAKG or ���FAOG���) detect
automatically if the output is connected to L- (p switching) or to L+ (n switching)�
►Disconnect the unit to acknowledge a change of the load connection�
Automatic load detection is only ensured when a resistor is switched in
series to a closed mechanical contact�
load detection is possible load detection impossible

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
10
6 Operating and display elements
12 3
1: sensing face
2: programming buttons
3: LED
7 Settings
7.1 Basic teach empty state
Using the basic teach empty state the unit suppresses the installation environ-
ment� The basic teach empty state resets the unit, an adjustment teach already
carried out is deleted�
►Empty the tank until the level is at least 20 mm
below the sensor�
Set the unit as normally open (output closes when the
tank is full):
►Press [OUT OFF] for min� 2 s (max� 6 s)�
> While pressing the pushbutton the LED flashes
slowly� After releasing the pushbutton, the LED
goes out� 2 - 6 s
Set the unit as normally closed (output opens when
the tank is full):
►Press [OUT ON] for min� 2 s (max� 6 s)�
> While pressing the pushbutton the LED flashes
slowly� After releasing the pushbutton, the LED
lights continuously� 2 - 6 s
The unit is now ready for operation� For the detection of media with a low dielectric
constant (e�g� plastic granulates or oils) no further setting is required�
9
UK
5.1 Wiring
p-switching (type ���FPKG��� or ���FPOG���)
n-switching (type ���FNKG��� or ���FNOG���)
BN = brown, BK = black, BU = blue
BN = OUT / IO-Link 4: OUT / IO-Link
5.2 Unit versions with auto-detect
On power up, unit types with auto-detect (types ���FAKG or ���FAOG���) detect
automatically if the output is connected to L- (p switching) or to L+ (n switching)�
►Disconnect the unit to acknowledge a change of the load connection�
Automatic load detection is only ensured when a resistor is switched in
series to a closed mechanical contact�
load detection is possible load detection impossible

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
10
6 Operating and display elements
12 3
1: sensing face
2: programming buttons
3: LED
7 Settings
7.1 Basic teach empty state
Using the basic teach empty state the unit suppresses the installation environ-
ment� The basic teach empty state resets the unit, an adjustment teach already
carried out is deleted�
►Empty the tank until the level is at least 20 mm
below the sensor�
Set the unit as normally open (output closes when the
tank is full):
►Press [OUT OFF] for min� 2 s (max� 6 s)�
> While pressing the pushbutton the LED flashes
slowly� After releasing the pushbutton, the LED
goes out� 2 - 6 s
Set the unit as normally closed (output opens when
the tank is full):
►Press [OUT ON] for min� 2 s (max� 6 s)�
> While pressing the pushbutton the LED flashes
slowly� After releasing the pushbutton, the LED
lights continuously� 2 - 6 s
The unit is now ready for operation� For the detection of media with a low dielectric
constant (e�g� plastic granulates or oils) no further setting is required�
11
UK
7.2 Adjustment teach full state
Necessary for aqueous media� The sensitivity of the unit is optimised� Later on,
the adjustment teach full state can be repeated at any time, an adjustment teach
empty state already carried out is not affected�
A basic teach empty state must be carried out prior to the adjustment teach full
state (→ 7.1 Basic teach empty state)! If it is not possible to empty the tank, a
basic teach empty state can be carried out by simulating the empty state (e�g�
adjustment when not installed, adjustment at a higher position)� For optimum
function it is necessary to carry out the “modified basic teach empty state“ →
7�3 Modified basic teach empty state) when the tank is emptied the next time�
►Fill the tank until the sensing face of the unit is
covered�
> For NO the LED lights, for NC it goes out�
Set the unit as normally open (output closes when the
tank is full):
►Press [OUT ON] for min� 6 s�
> While pressing the pushbutton the LED first flashes
slowly, after 6 s more quickly� After releasing the
pushbutton, the LED lights continuously� > 6 s
Set the unit as normally closed (output opens when
the tank is full):
►Press [OUT OFF] for min� 6 s�
> While pressing the pushbutton the LED first flashes
slowly, after 6 s more quickly� After releasing the
pushbutton, the LED goes out� > 6 s
7.3 Modified basic teach empty state
Recommended for deposits in the tank� Deposits are largely suppressed� This is
also recommended if it has not been possible to carry out a basic teach empty
state (e�g� if the sensor is set up on a full tank; details: → 7.2 Adjustment teach full
state)

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
12
Later on, the modified basic teach empty state can be repeated at any time, an
adjustment teach full state already carried out is not affected�
►Empty the tank until the level is below the sensing
face of the unit�
> For NO the LED goes out, for NC the LED lights�
Set the unit as normally open (output closes when the
tank is full):
►Press [OUT OFF] for min� 6 s�
> While pressing the pushbutton the LED first flashes
slowly, after 6 s more quickly� After releasing the
pushbutton, the LED goes out� > 6 s
Set the unit as normally closed (output opens when
the tank is full):
►Press [OUT ON] for min� 6 s�
> While pressing the pushbutton the LED first flashes
slowly, after 6 s more quickly� After releasing the
pushbutton, the LED lights continuously� > 6 s
7.4 Locking / unlocking
The unit can be electronically locked to protect it against unintentional setting�
►To lock press [OUT ON] and [OUT OFF]simulta-
neously for 10 s�
> Acknowledgement: LED state (yellow) changes for
a short time (the lit LED goes out briefly or the LED
which is not lit lights briefly)�
►To unlock repeat this step� 10 s
If the unit does not react, it may be locked�
11
UK
7.2 Adjustment teach full state
Necessary for aqueous media� The sensitivity of the unit is optimised� Later on,
the adjustment teach full state can be repeated at any time, an adjustment teach
empty state already carried out is not affected�
A basic teach empty state must be carried out prior to the adjustment teach full
state (→ 7.1 Basic teach empty state)! If it is not possible to empty the tank, a
basic teach empty state can be carried out by simulating the empty state (e�g�
adjustment when not installed, adjustment at a higher position)� For optimum
function it is necessary to carry out the “modified basic teach empty state“ →
7�3 Modified basic teach empty state) when the tank is emptied the next time�
►Fill the tank until the sensing face of the unit is
covered�
> For NO the LED lights, for NC it goes out�
Set the unit as normally open (output closes when the
tank is full):
►Press [OUT ON] for min� 6 s�
> While pressing the pushbutton the LED first flashes
slowly, after 6 s more quickly� After releasing the
pushbutton, the LED lights continuously� > 6 s
Set the unit as normally closed (output opens when
the tank is full):
►Press [OUT OFF] for min� 6 s�
> While pressing the pushbutton the LED first flashes
slowly, after 6 s more quickly� After releasing the
pushbutton, the LED goes out� > 6 s
7.3 Modified basic teach empty state
Recommended for deposits in the tank� Deposits are largely suppressed� This is
also recommended if it has not been possible to carry out a basic teach empty
state (e�g� if the sensor is set up on a full tank; details: → 7.2 Adjustment teach full
state)

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
13
UK
7.5 IO-Link
7.5.1 General information
This unit has an IO-Link communication interface which requires an IO-Link-
capable module (IO-Link master) for operation�
The IO-Link interface enables direct access to the sensor values and parameters
and provides the possibility to set the parameters of the unit during operation�
In addition communication is possible via a point-to-point connection with a USB
adapter cable�
You will find more detailed information about IO-Link at www�ifm�com/uk/io-link�
7.5.2 Device-specific information
You will find the IODDs necessary for the configuration of the IO-Link unit and
detailed information about sensor values, diagnostic information and parameters
in the overview table at www�ifm�com/uk/io-link�
7.5.3 Parameter setting tools
You will find all necessary information about the required IO-Link hardware and
software (e�g� ifm LINERECORDER SENSOR ZGS210) at www�ifm�com/uk/io-link�
8 Operation
Check whether the unit operates correctly� Bring about a sensor response by
taking suitable measures�
Display by LEDs (indepedent of the programmed output function):
LED yellow OFF: switching output disabled
LED yellow ON: switching output enabled
12
Later on, the modified basic teach empty state can be repeated at any time, an
adjustment teach full state already carried out is not affected�
►Empty the tank until the level is below the sensing
face of the unit�
> For NO the LED goes out, for NC the LED lights�
Set the unit as normally open (output closes when the
tank is full):
►Press [OUT OFF] for min� 6 s�
> While pressing the pushbutton the LED first flashes
slowly, after 6 s more quickly� After releasing the
pushbutton, the LED goes out� > 6 s
Set the unit as normally closed (output opens when
the tank is full):
►Press [OUT ON] for min� 6 s�
> While pressing the pushbutton the LED first flashes
slowly, after 6 s more quickly� After releasing the
pushbutton, the LED lights continuously� > 6 s
7.4 Locking / unlocking
The unit can be electronically locked to protect it against unintentional setting�
►To lock press [OUT ON] and [OUT OFF]simulta-
neously for 10 s�
> Acknowledgement: LED state (yellow) changes for
a short time (the lit LED goes out briefly or the LED
which is not lit lights briefly)�
►To unlock repeat this step� 10 s
If the unit does not react, it may be locked�

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
13
UK
7.5 IO-Link
7.5.1 General information
This unit has an IO-Link communication interface which requires an IO-Link-
capable module (IO-Link master) for operation�
The IO-Link interface enables direct access to the sensor values and parameters
and provides the possibility to set the parameters of the unit during operation�
In addition communication is possible via a point-to-point connection with a USB
adapter cable�
You will find more detailed information about IO-Link at www�ifm�com/uk/io-link�
7.5.2 Device-specific information
You will find the IODDs necessary for the configuration of the IO-Link unit and
detailed information about sensor values, diagnostic information and parameters
in the overview table at www�ifm�com/uk/io-link�
7.5.3 Parameter setting tools
You will find all necessary information about the required IO-Link hardware and
software (e�g� ifm LINERECORDER SENSOR ZGS210) at www�ifm�com/uk/io-link�
8 Operation
Check whether the unit operates correctly� Bring about a sensor response by
taking suitable measures�
Display by LEDs (indepedent of the programmed output function):
LED yellow OFF: switching output disabled
LED yellow ON: switching output enabled
14
9 Maintenance, repair, disposal
The operation of the unit is maintenance-free� To ensure a correct function:
•Keep the sensing face and a clear space, if any, free from deposits and foreign
bodies�
When replacing the sensor ensure that installation is done in the same way and a
sensor with the same settings is used�
It is not possible to repair the unit�
After use dispose of the unit in an environmentally friendly way in accordance with
the applicable national regulations�
10 Terms
Active zone
Area above the sensing face in which the sensor reacts to the approach of the
target�
Output function
Normally open: object within the active zone - output switched�
Normally closed: object within the active zone - output blocked�
Programmable: Choice between normally closed or normally open�
Positive switching: positive output signal (to L-)�
Negative switching: negative output signal (to L+)�
Power-on delay time
The time the sensor needs to be ready for operation after application of the
operating voltage (in the millisecond range)�
Hysteresis
Difference between the switch-on and the switch-off point�
Leakage current
Current for the internal supply of 2-wire units, also flows through the load when
the output is blocked�
Current consumption
Current for the internal supply of 3-wire DC units�

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
14
9 Maintenance, repair, disposal
The operation of the unit is maintenance-free� To ensure a correct function:
•Keep the sensing face and a clear space, if any, free from deposits and foreign
bodies�
When replacing the sensor ensure that installation is done in the same way and a
sensor with the same settings is used�
It is not possible to repair the unit�
After use dispose of the unit in an environmentally friendly way in accordance with
the applicable national regulations�
10 Terms
Active zone
Area above the sensing face in which the sensor reacts to the approach of the
target�
Output function
Normally open: object within the active zone - output switched�
Normally closed: object within the active zone - output blocked�
Programmable: Choice between normally closed or normally open�
Positive switching: positive output signal (to L-)�
Negative switching: negative output signal (to L+)�
Power-on delay time
The time the sensor needs to be ready for operation after application of the
operating voltage (in the millisecond range)�
Hysteresis
Difference between the switch-on and the switch-off point�
Leakage current
Current for the internal supply of 2-wire units, also flows through the load when
the output is blocked�
Current consumption
Current for the internal supply of 3-wire DC units�
15
UK
Switch point drift
Shifting of the switch point owing to changes of the operating conditions (e�g�
temperature, pressure, air humidity)�
Short-circuit protection
ifm sensors which are protected against excessive current by means of a pulsed
short-circuit protection� The inrush current of incandescent lamps, electronic
relays and low resistance loads may cause this protection to cut in and turn the
sensor off!
Operating voltage
The voltage range in which the sensor functions safely� A stabilised and
smoothed direct voltage should be used! Take into account residual ripple!
Technical data and further information at www�ifm�com

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
11. Defects and claims for compensation,
disclaimer
11.1. Barring any further claims we are only liable that the
supplied goods are free of defects until the initial transfer of
perils. Insignicant variations of the contracted appearance
and workmanship or marginal limitation of the usability or
suitability of the product are unremarkable.
The warranted condition, endurance and usability the prod-
uct is solely subject to the specication agreed in writing,
in the product specication and / or in this manual. Further
oral agreements, especially from preliminary talks, advertis-
ing and / or in related industrial standards will are only valid
as integral part of a written contract. Only conditions and
specications assured specically by us are valid. We do
not accept conditions or specications made by third par-
ties. Specically the specication assured in this manual
are valid. If the customer wants to use the product for other
than the intended purpose, he is obliged to thoroughly the
suitability of the product for the other purposes. We give no
warranty and no liability accrues for any applications that
are not agreed on by us explicitly and in written form.
Any manipulation of the device the electronic as well as any
attempt to modify the software, to inuence the software
or to read out or re-engineer the software of the driver unit
immediately causes a loss of warranty and all claims and
rights expire.
Every user is held responsible for the appropriate usage of
his switchable socket with capacitive sensor. The user
manual does not discharge you from your liability for a safe,
appropriate and secure application, installation, operation
and maintenance.
By using this manual you agree that in no circumstances
the manufacturer can or will be held liable for any personal
injuries or property damages which possibly occur due to
the usage of the device. This applies specically for any
damages that are due to inappropriate piping or plumbing.
Insufcient or missing cleaning- or maintenance intervals
and damages that might result due to these are not cov-
ered by warranty. This applies especially for calcinations
(salt water usage) and accumulated foreign particles (pond
usage) such as sand or gravel, which lead to damages on
rotors, bearings, rotor housing or motor housing, that are
not covered by warranty.
11.2. Our warranty for defects is strictly limited to supple-
mentary performance. This is upon our choice either re-
moval of defects or replacement delivery free from defects.
In the case of challenge, impossibility or failure of the sup-
plementary performance the customer has the right for im-
pairment or the right to withdraw from the contract.
Additional expenses which arise because the customer has
brought the sales item to another place than his subsidiary.
The manufacturer explicitly limits the warranty to the device
itself. We are not reliable for consequential damages, or
damages that are caused by a malfunction or failure of the
device, such as a loss of animals. It is in the responsibility
of the customer to provide back-up devices for the case of
a potential malfunction or failure of the device.
11.3. The customer has to check the goods immediately
thoroughly, also for product safety. Apparent damages
have to be reported in written form immediately. Hidden
damages have to be reported immediately after their dis-
covery. The customer is liable to report transport damages
within 24 hours to the carrier and/or the delivery service.
Disregarding the rules for checking and reporting results in
a loss of warranty.
11.4. Furthermore we are not liable for the consequences
of inappropriate application, usage, maintenance and han-
dling of the product by the customer or his subsidiaries,
neither for normal abrasion. This applies specically to the
consequences of thermal, chemical, electrochemical or
electrical inuences as well as for infringements against
our uses- and maintenance manuals. The same applies to
damages which are the result of changes or adjustments
by the customer which have not been approved by us in
beforehand.
11.5. Our liability for wanton negligence is limited to claims
of injury of life, body and health, to claims based upon the
law on product liability and to claims from culpable funda-
mental breach of the contract which peril contractual ob-
ligations. For the rest our liabilities for wantonly negligent
breach of contractual obligations, which are foreseeable at
the time of the conclusion of the contract, are barred.
Damages, which are unambiguously attributed to inappro-
priate usage of the product, are in general to be accounted
for by the customer. In the case of returns of the product the
customer has to use break-proof packaging for the product.
The customer is liable for any damages that can be ac-
counted to an inappropriate packaging.

Royal Exclusiv pumps &skimmers
Since 1986
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into
the search box or email: info@royal-exclusiv.de.
All information subject to change. We try our best, but printing errors reserved.
11.6. Claims against us become time-barred within a year
after the initial delivery of the goods to the customer. The
same applies to claims for damages regardless of their ju-
ridical cause. The limitation period does not apply to claims
based upon the malicious concealment of damages from
the injury of life, health or body and for other damages that
result out of intention or wanton negligence.
11.7. If it becomes apparent during our examination of dam-
ages reported by the customer or in the course of our re-
moval of defects, that the reported damages or claims were
made wantonly negligent or unwarranted, we may charge
an adequate consideration for our examination and for the
removal of defects. The customer has the right to neglect
a necessary repairing and to demand the return of the de-
vice. In general every examination of damages is bound to
lump-sum compensation if it occurs that the customer has
to be accounted for the damages.
11.8. Spare parts
Our liability to deliver and hold spare parts available is limit-
ed to the period of 5 years after initial shipment of the prod-
uct. Our respective list prices apply for spare parts.
11.9. Disposal
We offer our customers to take back products that fall under
the restriction of hazardous substances directive (ElektroG)
within Germany free of charge, for products, which were
brought into circulation after the 13th of August 2005. We
will take care for the disposal. If a customer chooses not to
let us take care for the disposal, he takes the responsibility
of a disposal according to legal regulations and discharges
us from our liabilities according to §10 sect. 2 ElektroG and
any associated liabilities of others.
11.10. Subject to alterations
The manufacture has the right for changes in hardware and
software of the product at any time without preliminary no-
tice, as long as these changes advance reliability or qual-
ity of the device. No claims can be made if for instance
design, functionality or performance of the device changes
elementary. The assured specication of the device is al-
ways guaranteed.
12. Manufacturer’s declaration
Titles against Royal Exclusiv®concerning the
products described in this manual adress on the
Royal Exclusiv®guarantee clauses.
Specication may vary due technical improvements.
12.1. Manufacturer
Royal Exclusiv®pumps and skimmers
Richard-Byrd-Str. 7 // 50829 Cologne // Germany
Fon +49(0)221/222886 0 // Fax +49(0)221/22288622
info@royal-exclusiv.de // www.royal-exclusiv.de
Made in Germany
Royal-Exclusiv® EAR-number: WEE.Reg.No. 83082352
12.2. Informations and support
Thank your for purchasing a Royal Exclusiv® oat
switch. This device is a high quality product made in Ger-
many with the highest manufacturing demands on modern
CNC maschines. This manual is supposed to help you to
setup the oat switch for use and to advice you with the
necessarily maintenance procedures.
To ensure longlasting satisfaction with this product we
please you to read this manual carefully and follow our
guidelines.
Royal Exclusiv® guarantees 5 years of spare part
availability for the oat switch.
Should the device in some way not meet the high de-
mands you expect from Royal Exclusiv®please con-
tact the dealer where you purchases your oat switch.
This is usually the best way for product support. However
you may feel free to contact our support on our website:
http://www.royal-exclusiv.de
Table of contents
Popular Switch manuals by other brands

D-Link
D-Link DGS-3208TG - Switch user guide

EMC
EMC Connectrix B Series Hardware reference manual

Panasonic
Panasonic Switch-M24eGi installation guide

EtherWAN
EtherWAN EX42300 series installation guide

THOMSON
THOMSON Grass Valley Triton TTN-BVS-0808 installation manual

Cisco
Cisco MCS 7800 Series Administration guide