FE A T U R E S
SIMPLE INSTALLATION
COMPACT FOOTPRINT
LOAD MONITORING
TEMPERATURE SENSOR READY
AUTO CALIBRATION
SINGLE MOTOR
Z-WAVE COMPATIBLE
Z-WAVE SCENE ACTUATOR DEVICE
Z-WAVE NODE NAME CAPABILITY
SAFETY TIMEOUT
LESS THAN 1WATT POWER CONSUMPTION
Basic Installation Procedure
Connect motor and power supply wires as indicated on the enclosure
Check that motor wires are correctly connected by using OPEN and CLOSE buttons
Swap motor wires if necessary
Set the motor mechanical limits
Calibration Procedure
Simultaneously press and hold OPEN and CLOSE for 5 seconds
The calibration procedure will open, close, then open the motor
At this point the unit is installed and ready to become part of a Z-Wave network
It is also possible to calibrate the unit by sending the proper Z-Wave configuration command
Uncalibrated units (brief LED flash every 1.5 seconds) will not respond to Z-Wave movement commands correctly
Sensor Installation
If an optional sensor is to be used with the unit, connect the two sensor wires to the sensor input
Sensor connections are not polarized, i.e., may be connected in any order
Multiple sensors must not be connected to the same sensor input
Z-Wave Network Installation
The unit may be joined to a Z-Wave network even if the unit is uncalibrated
To Include, place the primary controller in inclusion mode and press the Z button
To Exclude, place the primary controller in exclusion mode and press the Z button
For supported Z-Wave commands, refer to the Z-Wave Programmer’s Manual at our website
IN S T A L L A T I O N GU I D E
©2007 RS Scene Automation LLC. Product specifications subject to change without notice. DC1-ZW • 2007.09 • #004
5520 SW 159TH PL SE ∙ Bellevue, WA 98006
Phone: 425.644.1887 ∙ Fax: 425.644.1887
RS SC E N E AU T O M A T I O N
Z-WA V E MO T O R CO N T R O L L E R FA M I L Y
http://www.rssceneautomation.com
[email protected]
DC1-ZW
LED Modes
•Uncalibrated Continuous blink every 1.5 seconds
•Power Up One blink upon power up
•Set to Factory Defaults Three blinks when commanded to set factory defaults
•Z-Wave Command Received One long blink when Z-Wave command is received
Button Functions
•Set to Factory Defaults Press and hold Z button, then apply power to the unit
•Perform Auto Calibration Simultaneously press and hold OPEN and CLOSE for 5 sec
•Include / Exclude from Z-Wave Network Briefly press Z button
•Open or Close Motor Briefly press OPEN or CLOSE
Sensor
•Temperature Sensor Type Aprilaire interior flush mount model 8051
•Temperature Sensor Range 32°F - 105°F; (0°C - 40°C)
•Temperature Sensor Accuracy ±3% @ 25°C
•Mating Sensor Connector 2 conductor Female PTR AKZ1550/2-3.81 (18 - 24 AWG)
Electrical Specifications
•Operating Voltage 12 - 24 Volts DC
•Maximum Motor Current 10 Amps
•Fuse 10A 250V 5x20mm
•Nominal Power Consumption < 1W with no radio activity and motor relay activated
Physical Specifications
•Dimensions (including mounting flange) 5.1 inches (length); 2.0 inches (width); 0.75 inches (height)
•Dimensions (metric, including mounting flange) 129.5mm (length); 50.8mm (width); 19mm (height)
•Enclosure Color Bone
•Mounting Flange Hole Diameter 0.185 inches
•Mounting Flange Hole Distance 4.5 inches (114.3 mm)
•Operating Temperature Range 32°F - 105°F; (0°C - 40°C)
•Mating Power / Motor Connector 4 conductor Female PTR AKZ950/4-508-G (12 - 18 AWG)
Agency Listings / Certifications
•FCC VQH-DC1-ZW
•Z-Wave Pending
SP E C I F I C A T I O N S
©2007 RS Scene Automation LLC. Product specifications subject to change without notice. DC1-ZW • 2007.09 • #004
5520 SW 159TH PL SE ∙ Bellevue, WA 98006
Phone: 425.644.1887 ∙ Fax: 425.644.1887
RS SC E N E AU T O M A T I O N
Z-WA V E MO T O R CO N T R O L L E R FA M I L Y
http://www.rssceneautomation.com
[email protected]
DC1-ZW
FE D E R A L CO M M U N I C A T I O N S CO M M I S S I O N ST A T E M E N T
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
▪Reorient or relocate the receiving antenna
▪Increase the separation between the equipment and receiver
▪Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
▪Consult the dealer or an experienced radio/TV technician for help
The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer
could void the user's authority to operate this equipment.
IN D U S T R Y CA N A D A ST A T E M E N T
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired operation of the
device.
IN S T A L L A T I O N GU I D E

Popular Controllers manuals by other brands

Berker 7531 40 13 operating instructions

Berker

Berker 7531 40 13 operating instructions

Carel MasterAria user manual

Carel

Carel MasterAria user manual

Emerson Bettis Q series Installation, operation and maintenance manual

Emerson

Emerson Bettis Q series Installation, operation and maintenance manual

gefran GF_LOOPER 3.5” quick start guide

gefran

gefran GF_LOOPER 3.5” quick start guide

Sonus 5100 Configuration guide

Sonus

Sonus 5100 Configuration guide

Cypress F2MC Series Setup guide

Cypress

Cypress F2MC Series Setup guide

Graco 248921 310798D Instructions - parts

Graco

Graco 248921 310798D Instructions - parts

KBR multicomp D6 7 Series User Manual Technical Parameters

KBR

KBR multicomp D6 7 Series User Manual Technical Parameters

ICP DAS USA TPD-433F quick start guide

ICP DAS USA

ICP DAS USA TPD-433F quick start guide

Thermomax SMX 100 user manual

Thermomax

Thermomax SMX 100 user manual

AUMA AC 01.2-22X manual

AUMA

AUMA AC 01.2-22X manual

Siemens SINUMERIK 840D sl operating manual

Siemens

Siemens SINUMERIK 840D sl operating manual

American Megatrends MegaRAC MG9077 datasheet

American Megatrends

American Megatrends MegaRAC MG9077 datasheet

Nuvo Essentia BTicino NV-E6DS-BT manual

Nuvo

Nuvo Essentia BTicino NV-E6DS-BT manual

LOVATO ELECTRIC ATL10 manual

LOVATO ELECTRIC

LOVATO ELECTRIC ATL10 manual

Danfoss ECL Comfort 310 operating guide

Danfoss

Danfoss ECL Comfort 310 operating guide

Toro OSMAC RDR Satellite Controller installation instructions

Toro

Toro OSMAC RDR Satellite Controller installation instructions

LSI Avago SAS 9206-16e user guide

LSI

LSI Avago SAS 9206-16e user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.