Runleader HM035LT User manual

2.
+
6
x 1
1
x 1
x 1
x 2
x 1
mm
4
M3
M6
1
2
3
5
1.
a)
b)
7
8
9
※
2S
1
a)
b)
2S
b)
a)
+
-
Black wire
Battery
Red wire
12V
MADE IN CHINA
Multifunctional hour meter
Please read and understand following notice carefully, and correctly install and operate the
product before using.
Notice
1.Please use the product accordance with the user manual strictly.
2.Please do not try to disassemble the main unit and its accessories.
3.This meter or in the heavy rain can not be used underwater.
4.Fierce vibration and strong impact may make the product failure.
5.Incorrect installation of battery cover at the back side will make the front panel of main unit
fogged, condensed or watered.
6.Little error will be happened when measuring, within the normal range.
7.Installation needed professional , otherwise easily get an electric shock.
Product accessories list
Product
User manual
Zip ties
Screw fittings
Sensor Components
Dimension
Unit:
Installation
Remark: 3 different installation methods are available for the product. Please use any one of the 3 installation
methods as per users’ needs.
Double-sided adhesive
tape installation
Screws installation
Remark: Mounting plate should have the related fixing holes. If no, please make the fixing holes on the mounting plate.
Aluminium alloy mounting bracket installation
Remarks: When users need aluminium
alloy mounting bracket, please purchase
it separately.
Components installation
Input the power to product correctly.
According to the below picture to wrap the yellow cable to engine’s spark plug wires 5circles or
more, and fixed by zip ties.(Remark : If the cable is not be fixed firmly, it will affect the accuracy
of the test data.)
Connect the terminals of product to the cable components. Yellow cable
Plug wire
Ignition coils
5-10arounds, fixed by zip
ties after warp.
Verify the accuracy of the product installation
Temperature interface will display current temperature, start the engine, RPM interface display RPM,
which means the correct installation.
Region definition
In the non-setting mode, short press to view
menu interface, long press for 2S into setting
status. In the setting status, decrease the value.
Long press for 2S to save the data.
button
button
button
Switch the main interfaces, increase the value when setting
Temperature icon
Warning light
Timing light
Button operation explanation
Button name Short press Long press
Menu button
Setting button
View the submenu interface, decrease the value when setting
Switch the main interfaces or return to main interface, increase
the value when setting
Get into setting mode, quickly decrease the value when setting
Quickly increase the value when setting
In the setting mode, long press M+S to save and exit setting
Interface switching
In the non-setting mode to press “ ” to switch the interface
Temperature interface RPM interface Timing interface
Product operation
Temperature interface operation-------real-time display current temperature
Standby interface
Not connect to sensor, it will display “Err”, connect to the sensor, it will display the
current temperature
Short press
Short press
View the high temperature value Setting the high temperature value, value flashing.
Long press
Long press
View the max temperature Reset the max temperature value
Default high temperature reminder value is 100℃(212℉),
setting range:-40℃-+ 300℃(-40℉-+572℉)
When the measuring temperature exceeds the high temperature
reminder value, warning icon flashing, at the same time, the
measuring temperature value displays 3S and flashes 2S to remind
the high temperature, setting value will be saved after cut off the
power.
After resetting, max temperature value will be return to
default -40℃(-40℉)
When the temperature value exceeds the history recorded
value 2 times continuously, max temperature value will be
refreshed.
Mounting plate

a)
2
2S
a)
2S
b)
a)
a)
2S
1P1R
2P1R
3P1R
4P1R
6P1R
8P1R
3P2R
5P2R
0 19990---
0---19990
0 15000---
0 15000---
0 10000---
0 10000---
0 7500---
0 5000---
0 3750---
0 19990---
0 12000---
0---19990
1P2R
7
9
ABS
IP67
LED
41 *17mm
116g
69 * 37 *18mm
19999H
19999H
0 19990RPM-
10
11
01000H-
10RPM
%1
DC12V
-℃-+ ℃(-℉-+ ℉)40 300 40 572
a)
2S
a)
2
c)
MADE IN CHINA
2S
b)
a)
MADE IN CHINA
a)
2S
Short press
Long press
View the temperature unit Setting temperature unit
℃ and ℉ can be switched, default unit is ℃, short press
any button to switch the unit.
Finish the setting of temperature unit, all data about
temperature will be switched to the corresponding unit.
RPM interface operation
RPM main interface-------real-time display the current RPM
After 1S continuous signal is detected, LED
displays the current measuring speed.
Short press
Short press
Short press
Short press
Short press
View the high RPM reminder
Long press
Long press
Long press
Long press
Setting high RPM remind value, value flashing.
View the max RPM
Default: 8500,setting range:1000-19900.
When the measuring RPM exceeds the high RPM reminder
value, warning icon flashing, at the same time, the
measuring RPM value displays 3S and flashes 2S to remind
the high RPM, setting value will be saved after cut off the
power.
Max RPM return to the default data 0.
When the RPM value exceeds the history recorded value
2 times continuously, max RPM value will be refreshed.
Reset the max RPM
flash 3times
View stroke Setting the stroke value
Suitable for 9 types gasoline engine, initial value is 1P1R,
stroke types including: 1P1R, 2P1R, 3P1R, 4P1R, 6P1R, 8P1R,
1P2R, 3P2R, 5P2R
Timing interface operation
Timing main interface-----Display total working time
flash 3 times After 1S continuous signal is
detected, LED displays the
current measuring speed.
View the partial time
Clear the partial time
flash 3 times
Partial time return to default data 0.
View the maintenance reminder time
flash 3 times
Setting the maintenance reminder time
Long press
Return to the corresponding main
interface if there is no operation
between 10S.
Default value is 20, setting range: 0-1000.
When setting value is 0, maintenance time function is off: After
finish the maintenance time setting, the setting value will be
effective right now.
Count down display, when count to 0, warn icon flashes, press
button to clear the reminder icon, restart count down from the
last setting value after clearing.
Relationship between stroke and cylinder in setting RPM mode
RPM type Ignition Method Stroke and Cylinder RPM range
1 spark per revolution
2 spark per revolution
3 spark per revolution
4 spark per revolution
6 spark per revolution
8 spark per revolution
3 spark 2 revolution
5 spark 2 revolution
1 spark 2 revolution
4 stroke 2 cylinder
2 stroke 1 cylinder
4 stroke 4 cylinder
2 stroke 2 cylinder
4 stroke 6 cylinder
4 stroke 8 cylinder
4 stroke 12 cylinder
4 stroke 16 cylinder
4 stroke 3 cylinder
4 stroke 5 cylinder
4 stroke 1 cylinder
2 stroke 3 cylinder
Specifications &Parameter
Production name
Housing material
Total hour range
Partial hour range
RPM range
Maintenance hour range
RPM display accuracy
Waterproof level
Display mode
Display windows size(visible)
Product weight
Dimension
Temperature measuring range
Temperature measuring accuracy
Working voltage
Multifunction hour meter
Trouble shooting
Problems Possible reason Solution
No display on the screen
after input the power
1.Power voltage not enough.
2.Power wire is damaged
3.Positive of power and negative
of power wrong connected.
1. Change a new power
2.Repair or change power wires.
3.Re-install power correctly
Time no change or not
accurate after 6 minutes.or
RPM is not accurate
1.Cable loose or wrapped less cycles
2.Cable may damaged
3.Stroke type setting is incorrect
1.Tighten or wrap more cycles.
2.Repair or change cable.
3.Set the stroke type correctly.
LED screen display Err 1.Sensor is not connected well.
2.Sensor damaged
1.Re-install the sensor.
2.Replace a new sensor
No change on LCD display System halted due to interference Reconnect power source
This manual suits for next models
1