Russound ABUS A-H484 User manual

A-H484 Overview
The Russound A-H484 is a four-zone, four-source audio
distribution hub used with A-BUS amplified keypads. The
A-H484 can be linked to another A-H484 to increase the
number of zones in a system.
The A-H484 multisource hub supports four audio
sources in a four-zone A-BUS system. Each zone is
expandable to two rooms with inputs for A-K4 keypads.
You can select any source independently in each zone at
the keypad or with an A-LRC2 remote control.
NOTE: The A-VC2 amplified volume control is not
multisource-capable and is not recommended for use
with the A-H484 multisource hub.
A-H484 Features
• Four line-level audio inputs
• Four zone coupled outputs (2 keypads per zone)
• 12VDC trigger output
• Link in and out
• 4 routed, 1 common IR outputs
A-H484 Specifications
Power Supply: A-PS, 24VDC, 2.5A
(one required for each bank A, B)
Trigger Output: 12VDC, 100mA, 1/8” male
(tip (+). sleeve (-))
Keypad Connection: CAT-5, RJ-45 connector, T568A
Link Connection: CAT-5, RJ-45 connector, T568A
IR Emitter Connection: 1/8” male, tip (+), sleeve (-)
Dimensions: 6.5”W x 5”H x 1.5”D
(165 x 127 x 38mm)
Weight: 1.0 lb. 12 oz. (795g)
Safety Instructions
1. Read Instructions - All the safety and operating instructions should
be read before the appliance is operated.
2. Retain Instructions - The safety and operating instructions should be
retained for future reference.
3. Heed Warnings - All warnings on the appliance in the operating
instructions should be adhered to.
4. Follow Instructions - All operating and user instructions should be
followed.
5. Water and Moisture - The appliance should not be used near water;
for example, near a bathtub, washbowl, kitchen sink, laundry tub, in
a wet basement, or near a swimming pool.
6. Wall or Ceiling Mounting - The appliance should be mounted to a
wall or ceiling only as recommended by the manufacturer.
7. Heat - The appliance should be situated away from heat sources
such as radiators, heat registers, stoves, or other appliances (includ-
ing amplifiers) that produce heat.
8. Power Sources - The appliance should be connected to a power
supply only of the type described in the operating instructions or as
marked on the appliance.
9. Grounding or Polarization - Precaution should be taken so that the
grounding or polarization means of an appliance is not defeated.
10. Object and Liquid Entry - Care should be taken so that objects do
not fall and liquids are not spilled into the enclosure through the
openings.
11. Damage Requiring Service - The appliance should be serviced by
qualified service personnel when:
The power supply cord or the plug has been damaged;
Objects have fallen, liquid has been spilled into the appliance
The appliance has been exposed to rain
The appliance does not appear to operate normally
The appliance has been dropped or enclosure is damaged.
12. Servicing - The user should not attempt to service the appliance
beyond that described in the operating instructions. All other servic-
ing should be referred to qualified service personnel.
13. Care – From time to time you should wipe off the front panel with a
soft dry cloth.
Limited Warranty
The Russound A-H484 is fully guaranteed for two (2) years from the date of purchase
against all defects in materials and workmanship. During this period Russound will
replace any defective parts and correct any defect in workmanship without charge
for either parts or labor. For this warranty to apply, the unit must be installed and used
according to its written instructions. If service is necessary, it must be performed by
Russound. Russound assumes no responsibility for defects resulting from abuse or
servicing performed by an agency or person not specifically authorized in writing by
Russound. Damage to or destruction of components due to improper use voids the
warranty. In these cases the repair will be made at the owner’s expense. Accidental dam-
age and shipping damage are not considered defects under the terms of the warranty.
To return for repairs, the unit must be shipped to Russound at the owner’s expense,
along with a Return Authorization number and documentation explaining the nature
of the service required. Any product returned without prior written permission will
be returned to sender. Russound sells products only through authorized Dealers and
Distributors to ensure that customers obtain proper support and service. Any Russound
product purchased from an unauthorized dealer or other source, including retailers, mail
order sellers and online sellers will not be honored or serviced under existing Russound
warranty policy. Any sale of products by an unauthorized source or other manner not
authorized by Russound shall void the warranty on the applicable product.
CONNECTION INSTRUCTIONS FOR A-H484. REFER TO NUMBERED DIAGRAM ON REVERSE.
A-H484
Multisource, Multizone Hub
for A-BUS®System
Installation Manual
1 Amplified Keypads
The A-H484 has coupled zone outputs in two groups
of four (A and B) that support one or two A-KP2 or A-K4
keypads per zone. Source selection is shared by coupled
zone outputs. Connect up to eight A-BUS amplified
keypads to the A-H484 with CAT-5 cable. For clean
installations, use RJ-45 CAT-5 patch cables to connect
from the hub to an RJ-45 wall plate (optional), and wire
from the wall plate to the keypad.
NOTE: A-BUS keypads must be set to multisource mode
to be used with the A-H484 hub. See keypad installation
manuals for complete details.
The zone output on the A-H484 is a CAT-5 RJ-45
connector using T568A wire configuration. The A-K4
has an RJ-45 connector with T568A wire configuration
and the A-KP2 has a 110 punchdown connector for
the 8 individual conductors of the CAT-5 cable (use a
punchdown tool with a 110 blade to insert conductors).
2 IR Emitters
Routed IR Outputs and Common IR Output. Connect an
IR emitter such as the 845.1 to each of the 4 IR connectors
on the A-H484. When a source is selected from a zone,
the IR signal received through the zone’s keypad is
routed exclusively to that source via the A-H484’s Routed
IR outputs. This allows the use of multiple sources of
the same brand (for example, two identical DSS units).
The Common IR output sends out all IR signals and
can be used with an IR flasher that blankets all source
components.
3 Trigger Output
The 12VC trigger output can be used to control a
switched AC outlet (e.g., ACT-1) to turn power on and off
to source equipment. The trigger voltage is sent when
any zone is in the system is turned on. When the ALL OFF
command is used, the trigger is turned off. Use a 1/8”
male 2-conductor jack (not included).
4 Link In and Link Out
The Link In and Out is used to connect multiple A-H484
hubs to allows for use of additional A-BUS keypads. The
connection is made using an RJ-45 patch cable. The Link
connects the Routed IR, Common IR, and Status. Audio
signals are shared with linked A-H484 hubs using “Y”
cables to split the audio outputs.
The A-H484 CANNOT be linked to single-source A-BUS
Hubs such as A-H2, A-H4P and A-H1, as these use a
different format for linking.
NOTE: The A-H484 is not recommended for use with the
Russound CAV6.6 controller/amplifier.
5 Sources
The A-H484 has four stereo audio inputs that support
connections to multiple audio sources. If sources are
connected to an existing home theater receiver, they can
be shared with the A-H484 by using “Y” connectors for
the audio outputs.
6 Multisource Mode for A-K4 Keypad
When used with the A-H484, the A-K4 must be set to
multisource mode by moving a jumper on the keypad.
The jumpers and pins are located under the faceplate on
the right side of the keypad (facing front). The pins are
jumpered to select between 1, 4 and 6 sources. Set for 4
sources when used with the A-H484 hub (4 sources = top
two pins jumpered).
7 Power Supply
The A-H484 hub and amplified keypads are powered
by the A-PS 24VDC/2.5A power supply. Each row (A and
B) must have its own power supply. The A-PS should
be plugged into an unswitched AC outlet (one that is
live all the time). When the A-PS is providing power, the
A-H484’s POWER LED will illuminate once a keypad is
turned on.
8 Installation
Install the A-H484 near the system’s source equipment
using screws or hook and loop fastener. The A-H484 will
also fit many structured wiring distribution panels.
9 Operation
The A-H484 is designed to be used with A-KP2 and
A-K4 multisource-capable amplified keypads.
A-KP2 and A-K4 keypads can be operated manually or
by using the A-LRC2 remote control. If using installed IR
emitters, sources can be operated with their own remote
control by aiming it at the IR window on an A-K4 keypad.
When the A-K4 keypad is set in multisource mode, tap
the power button to toggle through and select a source.
The top LEDs of the volume indicator show (from top to
bottom) the source that is selected (top LED is source 1,
next LED down is source 2, etc).
Russound, Inc. 5 Forbes Rd., Newmarket, NH 03857, USA
tel 603.659.5170 • fax 603.659.5388 www.russound.com
technical support: 866.888.7466 e-mail: [email protected]
28-1157 Rev. 3 05/30/13
Copyright ©2012 Russound® All rights reserved. All trademarks
are the property of their respective owners. Russound is not
responsible for typographical errors or omissions. Specications
are subject to change without notice.
A-BUS is a registered trademark of LeisureTech Electronics Pty
Ltd Australia. This product may be covered by one or more of the
following patents: US #7,181,023, #6,389,139; EP #1004222, AU
#739808, NZ #502982, Mexico #241196, Canada #CA2301062.
Pos (+)
Neg (–)
Tuner
CD Changer
Attach emitter to
source component’s
IR window
RJ-45 CAT-5
patch cable
Link ports of next
A-H484 hub
A-K4 (back) A-K4 (back)
CAT-5 cable
CAT-5 cable
A-PS power supplies
RCA cable
IR emitter
L GAIN R
Hub
L GAIN R
Hub
A-K4 (front)
CONNECTION DIAGRAM FOR A-H484. REFER TO THE NUMBERED INSTRUCTIONS ON REVERSE. DIAGRAMS ARE NOT TO SCALE.
1 1
1
2
2
44
5
3
6
Note: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part
15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment o
and on, the user is encouraged to try to correct the interference
by one of or more of the following measures: reorient or relocate
the receiving antenna; increase the separation between the
equipment and receiver; connect the equipment into an outlet on
a circuit dierent from that to which the receiver is connected, or
consult the dealer or an experienced radio/TV technician for help.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme
NMB-003 du Canada.

Other Russound Switch manuals

Russound 857 User manual

Russound

Russound 857 User manual

Russound A-BUS A-H4P User manual

Russound

Russound A-BUS A-H4P User manual

Russound A-SZ4 User manual

Russound

Russound A-SZ4 User manual

Russound A-BUS A-LC2 User manual

Russound

Russound A-BUS A-LC2 User manual

Russound A-BUS A-H4D User manual

Russound

Russound A-BUS A-H4D User manual

Russound A-BUS A-H484 User manual

Russound

Russound A-BUS A-H484 User manual

Russound A-BUS A-H4D User manual

Russound

Russound A-BUS A-H4D User manual

Russound A-BUS A-H2 User manual

Russound

Russound A-BUS A-H2 User manual

Russound A-H484 User manual

Russound

Russound A-H484 User manual

Russound AX-6 User manual

Russound

Russound AX-6 User manual

Russound A-MSS User manual

Russound

Russound A-MSS User manual

Russound A-BUS A-H4Dx User manual

Russound

Russound A-BUS A-H4Dx User manual

Russound A-BUS A-H4 User manual

Russound

Russound A-BUS A-H4 User manual

Russound AB-3.2 User manual

Russound

Russound AB-3.2 User manual

Russound ComPoint ISH1 User manual

Russound

Russound ComPoint ISH1 User manual

Russound A-BUS A-H4D User manual

Russound

Russound A-BUS A-H4D User manual

Russound A-H2 User manual

Russound

Russound A-H2 User manual

Russound AB-1.2-2.2 User manual

Russound

Russound AB-1.2-2.2 User manual

Russound A-BUS A-H4D User manual

Russound

Russound A-BUS A-H4D User manual

Popular Switch manuals by other brands

Sierra Wireless AirCard user guide

Sierra Wireless

Sierra Wireless AirCard user guide

Datakom DKG-171 Installation and operating instructions

Datakom

Datakom DKG-171 Installation and operating instructions

Beck Group 22 CPS-4 Replacement instructions

Beck

Beck Group 22 CPS-4 Replacement instructions

HP ProCurve Switch 2626-PWR Manual supplement

HP

HP ProCurve Switch 2626-PWR Manual supplement

REV Ritter RF102R Assembly and operating instructions

REV Ritter

REV Ritter RF102R Assembly and operating instructions

Kärcher 6.997 Series manual

Kärcher

Kärcher 6.997 Series manual

HP 6125XLG Configuration guide

HP

HP 6125XLG Configuration guide

H3C S5830V2 series Command reference

H3C

H3C S5830V2 series Command reference

Guntermann & Drunck TradeSwitch4-PS/2 Installation and operation

Guntermann & Drunck

Guntermann & Drunck TradeSwitch4-PS/2 Installation and operation

Carmanah SPEEDCHECK G Series Guide

Carmanah

Carmanah SPEEDCHECK G Series Guide

DANLERS BMPIR10M Installation notes

DANLERS

DANLERS BMPIR10M Installation notes

Cerio PoE Series user guide

Cerio

Cerio PoE Series user guide

iNels RFSA-11B manual

iNels

iNels RFSA-11B manual

Cisco IE 4010 Product documentation

Cisco

Cisco IE 4010 Product documentation

Linksys SD208 - Small Business Unmanaged Switch Brochure & specs

Linksys

Linksys SD208 - Small Business Unmanaged Switch Brochure & specs

ATEN RCM Series user manual

ATEN

ATEN RCM Series user manual

TRENDnet TK-207K - KVM Switch - USB Specifications

TRENDnet

TRENDnet TK-207K - KVM Switch - USB Specifications

Adler ASM512 INSTALLATION, MAINTENANCE AND OPERATING MANUAL INSTRUCTION

Adler

Adler ASM512 INSTALLATION, MAINTENANCE AND OPERATING MANUAL INSTRUCTION

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.