RFSA-11B, RFSA-61B
Wireless switch unit
EN
02-55/2016 Rev.5
Made in Czech Republic
Technical parameters /
Supplyvoltage:
Apparent input:
Dissipated power:
Supplyvoltagetolerance:
Output
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Min. DC switching power:
Mechanical service life:
Electrical service life(AC1):
Control
RF, by command from transmitter:
Manual control:
Rangein free space:
Other data
Operating temperature:
Operating position:
Mounting:
Protection:
Overvoltagecategory:
Contamination degree:
Terminals(CY wire, cross-section):
Length of terminals:
Dimensions:
Weight:
Related standards:
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Instal-
lation and connection can be carried out only by a person with adequate professional qualification upon under-
standing this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free
function of the device also depends on transportation, storing and handling. In case you notice any sign of damage,
deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat
this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure
that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regula-
tions, norms, directives and professional, and export regulations for working with electrical devices. Do not touch
parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of
RF components in a building where the installation is taking place. RF Control is designated only for mounting in
interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into
metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible.
RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, inter-
fered, battery of the transceiver can get flat etc. and thus disable remote control.
Attention:
When you instal iNELS RF Control system, you have to keep
minimal distance 1 cm between each units.
Between the individual commands must be an interval
of at least 1s.
RFSA-11B/230V RFSA-11B/120V RFSA-11B/24V
RFSA-61B/230V RFSA-61B/120V RFSA-61B/24V
Selecting the memory function /
• Memory function on:
- For functions 1-4, these are used to store the last state of the relay output before the supply
voltage drops, the change of state of the output to the memory is recorded 15 seconds after
the change.
- For functions 5-6, the target state of the relay is immediately entered into the memory after the
delay, after re-connecting the power, the relay is set to the target state.
• Memory function off:
When the power supply is reconnected, the relay remains off.
12
Press of programming button on receiver RFSA-x1B for 1 second
will activate receiver RFSA-x1B into programming mode. LED is
flashing in 1s interval.
Pressing the programming button on the RFSA-x1B receiver for
less than 1 second will finish the programming mode, this will
reverse the memory function. The LED lights up according to
the current pre-set memory function. The set memory function
is saved.
Every other change is made in the same way.
PROG > 1s
1 x PROG < 1s
1 x
6/6
DE
Funkgesteuerte Schalteinheit
AT
www.elkoep.com / www.elkoep.de / www.elkoep.at
ELKO
EP
,
s.r
.o.
|
P
alackého
493
|
769
01
Holešov,
Všetuly
|
Czech
Republic
|
e-mail:
[email protected] |
Support:
+420
778
427
36
6ELKO
EP
Germany
GmbH
|
Minoritenstr
.
7
|
50667
Köln
|
Deutschland
|
E-mail:
[email protected] |
T
el:
+49
(0)
221
222
837
80
ELKO EP Austria GmbH | Laurenzgasse 10/7 | 1050 Wien | Österreich | E-mail: elko@elkoep.at | Tel: +43 (0) 676 942 9314
230VAC/ 50-60 Hz120 VAC/ 60Hz12-24VAC/DC 50-60Hz
7VA / cos φ = 0.1 7VA / cos φ = 0.1 --
0.7W 0.7 W 0.7W
+10 %; -15 %
1x switching / Schaltkontakt (AgSnO2)
16 A/ AC1
4000 VA / AC1, 384W / DC
30A/ < 3 s
250 VAC1 / 24VDC
500 mW
3x107
0.7x105
866 MHz, 868 MHz, 916 MHz
button PROG /Taste PROG (ON/OFF)
up to / bis zu 200 m
-15 ... + 50 °C
any / beliebig
free at lead-in wires / Frei an den Anschlussdrähten
IP 30
III.
2
2x 0.75mm2, 2x 2.5 mm2
90 mm
49x 49x 21 mm
46g
EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No426/2000 Coll.(Directive 1999/EC
) /
EN 60669, EN 300220, EN 301489 Richtlinie RTTE, RG Nr.426/2000 Sgl.(Richtlinie 1999/EG)
Technische Parameter
Spannungsversorgung:
Scheinleistung Eingang:
Verlustleistung:
Toleranz Spannungsversorgung:
Ausgang
Anzahl der Kontakte:
Messstrom:
Schaltleistung:
Spitzenstrom:
Schaltspannung:
Min. DC Schaltleistung:
Mechanische Lebensdauer:
Electrische Lebensdauer (AC1):
Steuerung
RF Signal durch Sender:
ManuelleSteuerung:
Reichweite im Freien:
Andere Daten
Arbeitstemperatur:
Arbeitspositionposition:
Installation:
Schutzart:
Kategorie Überspannung:
Verschmutzungsgrad:
Anschlüsse (CY Draht, Querschnitt):
Längeder Anschlusskabel:
Abmessungen:
Gewicht:
Standards:
Warnung
Die Betriebsanleitung dient der Montage, sowie dem Benutzer des Geräts. Sie ist immer im Lieferumfang enthalten.
Die Montage und der Anschluss darf nur durch eine Person mit einer angemessenen Berufsqualifikation, nach die-
ser Bedienungsanleitung und Funktionen des Gerätes und unter Beachtung aller gültigen Vorschriften ausgeführt
werden. Die störungsfreie Funktion des Gerätes hängt auch von Transport, Lagerung und Handhabung ab. Falls Sie
irgendwelche Anzeichen von Beschädigung, Verformung, Fehlfunktionen oder Fehlteilen feststellen, ie das Gerät
nicht und wenden sich an den Verkäufer. Es ist notwendig, dieses Produkt und Teile davon als Elektronikschrott
zu behandeln, nachdem seine Lebensdauer beendet ist. Vor Beginn der Montage ist sicherzustellen, dass alle
Leitungen, miteinander verbundenen Teilen oder Anschlüsse spannungsfrei sind. Während der Montage und der
Wartung sind die Sicherheitsvorschriften, Normen, Richtlinien für die Arbeit mit elektrischen Geräten zu beachten.
Berühren Sie keine Teile des Gerätes, die mit Energie versorgt werden - Lebensgefahr. Aufgrund der Sendeleistung
des RF Signals, beachten Sie den geeigneten Montageort der RF-Komponenten in einem Gebäude, in dem die Ins-
tallation stattfindet. RF Control ist nur für die Montage im Innenbereich geeignet. Geräte sind nicht für die Montage
in Außenbereichen und Feuchträumen geeignet. RF Control Komponenten dürfen nicht in Metallschalttafeln und
in Kunststoff -Schalttafeln mit Metalltür installiert werden - Die Durchlässigkeit des RF-Signals ist dann nicht gege-
ben. RF Control ist nicht für Aufzüge geeignet - das RF Signal kann gestört und abgeschirmt werden, die Batterie
des Emfängers verliert schnell die Leistung etc. - dieses verhindert die Steuerung durch eine Steuerungseinheit.
Achtung:
Bei der Installation Aktoren iNELS RF Control muss es
der Mindestabstand 1 cm geachtet sein.
Zwischen aufeinanderfolgenden Befehlseingaben sollte
mindesten 1s Abstand liegen.
Auswählen einer Speicherfunktion
• Speicherfunktion an:
- Für die Funktionen 1-4 wird es verwendet, um den letzten Zustand des Relaisausgangs vor
dem Netzausfall zu speichern, wobei der Zustand des Ausgangssignals in den Speicher nach
15 s aus der Änderung geschrieben wird.
- Bei den Funktionen 5-6 wird der Zielzustand des Relais sofort nach Ablauf der Verzögerung in
den Speicher eingegeben, nach erneutem Verbinden der Stromversorgung wird das Relais
auf den Zielzustand gesetzt.
• Speicherfunktion aus:
Wenn die Stromversorgung wieder angeschlossen ist, bleibt das Relais ausgeschaltet.
Drücken der Programmiertaste am Empfänger RFSA-x1B für 1 Se-
kunde aktiviert den Programmiermodus des Empfängers RFSA-
x1B LED blinkt im 1s-Intervall. Die Programmierung beendet die Programmiertaste auf RFSA-
x1B, weniger als 1 Sekunde, wodurch die Speicherfunktion auf
das Gegenteil geändert wird. Die LED leuchtet entsprechend der
aktuell eingestellten Speicherfunktion. Die gespeicherte Spei-
cherfunktion wird gespeichert.
Jede andere Veränderung wird in gleicher Weise gemacht.