Safeline FD1600 User manual

www.safeline-group.com
09.2019 © 2019 SafeLine and all the SafeLine products and
accessories are copyrighted by law.
Made in Tyresö Sweden with quality and care
FD1600
Manual
Floor Displays & Voice Announcers
FD1600 v.2.03 EN

2FD1600 v.2.03 EN
Introduction
Introduction
Technical data 3
General information 4
System description 5
Content
Overview
Installation
Start up
Conguration
LED indicators & component list 6
Inputs 7
Wiring diagram FD1600 8
Wiring Diagram FD1600 - IPS 10
Start-up 12
Menu buttons 13
Menu tree structure 14
Floor texts 17
Display fonts 17
Arrows 18
Boot menu 19
Setup menu 19
Learning mode with IPS 20
Dynamic menus 20
Memory card 20
Sound les 21
Checklist before deployment of IPS and FD1600 22
Certication
Declaration of conformity 23

3
SafeLine FD1600
FD1600 v.2.03 EN
Introduction
External power: 18-28 VDC
Power consumption: 40-200 mA at 24 VDC
CAN: Fixed speed 125 kBit/s
Up to 63 oor units (plus two car units, and one system unit).
One CANopen compliant absolute encoder.
Inputs / Outputs 8 Inputs and 1 Output
Inputs: 24 V / 0 V
Memory card microSD card, SD and SDHC (up to 32 GB) with soundles
Speaker output: 3W 8
Ω
Size: 80 x 61 x 20 mm (H x W x D)
Operating temperature: +5° C — +40° C
Orientations: 0°, 90°, 180° or 270°
Inputs: Decimal, binary, gray, IPS, absolute encoder
Matrix: 10 rows x 16 columns
Color: Red, blue
Bluetooth:
Audio les:
Bluetooth 4.0
BLE 2,4 GHz
Format WAVE-8 or 16kHz, 16 bit mono, max 16 sec/le
Technical data main unit

4FD1600 v.2.03 EN
Introduction
This unit was built with state-of-the-art technology and to
generally recognised safety related technical standards currently app-
licable. These installation instructions are to be followed by all people
working with the unit, in both installation and maintenance.
It is extremely important that these installation instructions are made
available at all times to the relevant technicians, engineers or servicing
and maintenance personnel. The basis prerequisite for safe handling
and trouble free operation of this system is a sound knowledge of the
basic and special safety regulations concerning conveyor technology,
and elevators in particular. The unit may only be used for its intended
purpose. Note in par ticular that, no unauthorised changes or additions
may be made inside the unit or individual components.
Exclusion of liability
The manufacturer is not liable with respect to the buyer of this product
or to third par ties for damage, loss, costs or work incurred as a result of
accidents, misuse of the product, incorrect installation or illegal chang-
es, repairs or additions. Claims under warranty are likewise excluded in
such cases. The technical data is the latest available. The manufacturer
accepts no liability arising from printing errors, mistakes or changes.
Declaration of conformity
Download ”The declaration of conformity” at our website:
www.safeline-group.com
Safety Precautions!
- Only trained professionals, who are authorised to work on the equip-
ment, should install and con gure this product.
- This quality product is dedicated for the lift industry. It has been
designed and manufactured to be used for its speci ed purpose only.
If it is to be used for any other purpose, SafeLine must be contacted in
advance.
- It should not be modi ed or altered in any way, and should only be
installed and con gured stric tly following the procedures described in
this manual.
- All applicable health and safety requirements and equipment
standards should be considered and strictly adhered to when installing
and con guring this product.
- After installation and con guration this product and the operation
of the equipment should be fully tested to ensure correct operation
before the equipment is returned to normal use.
Electrical and electronic produc ts may contain materials, parts and
units that can be dangerous for the environment and human health.
Please inform yourself about the local rules and disposal collection
system for electrical and electronic products. The correct disposal of
your old product will help to prevent negative consequences for the
environment and human health.
General
information
This unit was built with state-of-the-art technology and to
generally recognised safety related technical standards currently app-
licable. These installation instructions are to be followed by all people
working with the unit, in both installation and maintenance.
It is extremely important that these installation instructions are made
available at all times to the relevant technicians, engineers or servicing
and maintenance personnel. The basis prerequisite for safe handling
and trouble free operation of this system is a sound knowledge of the
basic and special safety regulations concerning conveyor technology,
and elevators in particular. The unit may only be used for its intended
purpose. Note in par ticular that, no unauthorised changes or additions
may be made inside the unit or individual components.
Exclusion of liability
The manufacturer is not liable with respect to the buyer of this product
or to third par ties for damage, loss, costs or work incurred as a result of
accidents, misuse of the product, incorrect installation or illegal chang-
es, repairs or additions. Claims under warranty are likewise excluded in
such cases. The technical data is the latest available. The manufacturer
accepts no liability arising from printing errors, mistakes or changes.
Declaration of conformity
Download ”The declaration of conformity” at our website:
www.safeline-group.com
Safety Precautions!
- Only trained professionals, who are authorised to work on the equip-
ment, should install and con gure this product.
- This quality product is dedicated for the lift industry. It has been
designed and manufactured to be used for its speci ed purpose only.
If it is to be used for any other purpose, SafeLine must be contacted in
advance.
- It should not be modi ed or altered in any way, and should only be
installed and con gured stric tly following the procedures described in
this manual.
- All applicable health and safety requirements and equipment
standards should be considered and strictly adhered to when installing
and con guring this product.
- After installation and con guration this product and the operation
of the equipment should be fully tested to ensure correct operation
before the equipment is returned to normal use.
Electrical and electronic produc ts may contain materials, parts and
units that can be dangerous for the environment and human health.
Please inform yourself about the local rules and disposal collection
system for electrical and electronic products. The correct disposal of
your old product will help to prevent negative consequences for the
environment and human health.
General
information

5
2
1
FD1600 v.2.03 EN
Introduction
This unit was built with state-of-the-art technology and to
generally recognised safety related technical standards currently app-
licable. These installation instructions are to be followed by all people
working with the unit, in both installation and maintenance.
It is extremely important that these installation instructions are made
available at all times to the relevant technicians, engineers or servicing
and maintenance personnel. The basis prerequisite for safe handling
and trouble free operation of this system is a sound knowledge of the
basic and special safety regulations concerning conveyor technology,
and elevators in particular. The unit may only be used for its intended
purpose. Note in par ticular that, no unauthorised changes or additions
may be made inside the unit or individual components.
Exclusion of liability
The manufacturer is not liable with respect to the buyer of this product
or to third par ties for damage, loss, costs or work incurred as a result of
accidents, misuse of the product, incorrect installation or illegal chang-
es, repairs or additions. Claims under warranty are likewise excluded in
such cases. The technical data is the latest available. The manufacturer
accepts no liability arising from printing errors, mistakes or changes.
Declaration of conformity
Download ”The declaration of conformity” at our website:
www.safeline-group.com
Safety Precautions!
- Only trained professionals, who are authorised to work on the equip-
ment, should install and con gure this product.
- This quality product is dedicated for the lift industry. It has been
designed and manufactured to be used for its speci ed purpose only.
If it is to be used for any other purpose, SafeLine must be contacted in
advance.
- It should not be modi ed or altered in any way, and should only be
installed and con gured stric tly following the procedures described in
this manual.
- All applicable health and safety requirements and equipment
standards should be considered and strictly adhered to when installing
and con guring this product.
- After installation and con guration this product and the operation
of the equipment should be fully tested to ensure correct operation
before the equipment is returned to normal use.
Electrical and electronic produc ts may contain materials, parts and
units that can be dangerous for the environment and human health.
Please inform yourself about the local rules and disposal collection
system for electrical and electronic products. The correct disposal of
your old product will help to prevent negative consequences for the
environment and human health.
General
information
Car unit
(max 2 units)
CAN bus
Floor unit
optional, (max 63 units)
System
description
FD1600 is a system consisting of floor and car displays. The system
is wired together via CAN bus.
The floor position information can be set directly at the unit's input
or from external source. External source can be a hardwired absolute
encoder or a hardwired position unit.
The FD1600 unit system may contain:
• Floor unit (up to 63 floors)
• Car unit (up to 2 units)
• System unit (none or 1 unit)
• External position unit (none or 1 unit)
It is also possible to use only one display without any connection to
the CAN bus (standalone).
Each unit must be
programmed with a unique
unit ID (unit address) and a
working mode. Also assure
that only one unit control the
oor position.
System unit (SYS)
(optional, max. 1 unit)
Floor unit
optional, (max 63 units)
External position unit
(optional, max 1 unit)
IPS or absolute encoder

6
TERM
ON
OFF
SD-CARD
USB
+24V
CAN H
GND
CAN L
GND
IN 1
IN 2
IN 3
IN 4
IN 8
IN 5
IN 6
IN 7
SPK
GND
OUT
24V
3
5
6
7
4
9
8
ab c d e
2
1
FD1600 v.2.03 EN
Overview
LED indicators &
component list
LED
aGreen USB LED Constantly lit when a USB-cable is
connected.
bGreen CAN BUS detect Flashing when valid CAN message
detected.
cRed CAN BUS error Lit or ashing when BUS error
detected (auto recovery).
dYellow SD LED Constantly lit (for 2 minutes) when SD
card is inserted and working. After 2
minuter the LED-indicator turns off.
eGreen power Constantly lit when powered up.
All connections have to be in
place before powering up the
installation. Changes in the
wiring with a powered
installation is not allowed.
4. SD card slot.
5. Output for speaker.
6. Output (no function).
7. USB outlet for conguration
and SW update.
8. Input for decimal, binary and gray.
9. Input for power and CAN
BUS connection.
1. LED indicator.
a. USB cable connected
b. CAN BUS
c. CAN BUS error
d. SD card
e. Power
2. Termination switch
3. Menu buttons.

7
TERM
ON
OFF
SD-CARD
USB
+24V
CAN H
GND
CAN L
GND
IN 1
IN 2
IN 3
IN 4
IN 8
IN 5
IN 6
IN 7
SPK
GND
OUT
24V
FD1600 v.2.03 EN
Overview
Inputs
FD1600 can handle different
signals from a controller, these
can be sourced from +24 VDC
or 0 VDC.
Brown
Blue
Yellow
Green
Red
Black
Orange
Grey
Default binary inputs (for 15 oors)
Input 1 Binary 1 Input 5 Programmable
Input 2 Binary 2 Input 6 Programmable
Input 3 Binary 4 Input 7 Programmable
Input 4 Binary 8 Input 8 Programmable
Binary signals
Binary code is a standardized way to control outputs that are used
for oor displays.
Default gray code inputs (for 15 oors)
Input 1 Gray code 1 Input 5 Programmable
Input 2 Gray code 2 Input 6 Programmable
Input 3 Gray code 3 Input 7 Programmable
Input 4 Gray code 4 Input 8 Programmable
Gray code signals
Gray code is an uncommon way to control oor displays. You
only change one input at a time, which minimizes the risk of
error. It is often used on older controllers.
Default decimal inputs (oor 1-8)
Input 1 Floor 1 Input 5 Floor 5
Input 2 Floor 2 Input 6 Floor 6
Input 3 Floor 3 Input 7 Floor 7
Input 4 Floor 4 Input 8 Floor 8
Decimal signals (one-oor-per-pin)
The old way to control oor displays are called decimal or
one-oor-per-pin.
Default decimal inputs (oor 9-16)
Note: two FD1600 units needs to be installed to
address oors 9-16
Input 1 Floor 9 Input 5 Floor 13
Input 2 Floor 10 Input 6 Floor 14
Input 3 Floor 11 Input 7 Floor 15
Input 4 Floor 12 Input 8 Floor 16

8
TERM
ON
OFF
SD-CARD
USB
+24V
CAN H
GND
CAN L
GND
IN 1
IN 2
IN 3
IN 4
IN 8
IN 5
IN 6
IN 7
SPK
GND
OUT
24V
24V DC
2 A
GND
+24V
Optional
FD1600
FD1600 v.2.03 EN
Installation
Green
Grey
Brown
Yellow
White
Grey
Orange
Black
Red
Green
Yellow
Blue
Brown
In car
Unit ID: CAR1
Main mode: Decimal,
gray, binary
Term: On
Wiring diagram
FD1600
Cable for decimal,
binary and gray
code. Also used for
fixed messages
Binary, decimal and
gray decoding

9
3
2
1
4
TERM
ON
OFF
SD-CARD
USB
+24V
CAN H
GND
CAN L
GND
IN 1
IN 2
IN 3
IN 4
IN 8
IN 5
IN 6
IN 7
SPK
GND
OUT
24V
TERM
ON
OFF
SD-CARD
USB
+24V
CAN H
GND
CAN L
GND
IN 1
IN 2
IN 3
IN 4
IN 8
IN 5
IN 6
IN 7
SPK
GND
OUT
24V
TERM
ON
OFF
SD-CARD
USB
+24V
CAN H
GND
CAN L
GND
IN 1
IN 2
IN 3
IN 4
IN 8
IN 5
IN 6
IN 7
SPK
GND
OUT
24V
FD1600
FD1600
FD1600
FD1600 v.2.03 EN
Installation
In car
Unit ID: CAR2
Main mode: Normal
Term: off
Top oor
Unit ID: Floor(X)
Main mode: Normal
Term: off
Bottom oor
Unit ID: Floor1
Main mode: Normal
Term: on

10
24VDC
2 A
TERM
ON
OFF
SD-CARD
USB
+24V
CAN H
GND
CAN L
GND
IN 1
IN 2
IN 3
IN 4
IN 8
IN 5
IN 6
IN 7
SPK
GND
OUT
24V
GND
+24V
IPS
FD1600
Optional
FD1600 v.2.03 EN
Installation
Wiring Diagram
FD1600 - IPS
Wiring diagram for car unit
and/or oor units.
Grey
Orange
Black
Red
Green
Yellow
Blue
Brown
In car
Unit ID: CAR1
Main mode:
Ext. position unit (CAN)
Term: Off
NOTE! If only one display
is used set Term to on.
Used for fixed messages
IPS: Install
on car roof
Term: On
NOTE! If only one
display is connected
set Term to on.
Green
Grey
Brown
Yellow
White

11
3
2
1
4
TERM
ON
OFF
SD-CARD
USB
+24V
CAN H
GND
CAN L
GND
IN 1
IN 2
IN 3
IN 4
IN 8
IN 5
IN 6
IN 7
SPK
GND
OUT
24V
TERM
ON
OFF
SD-CARD
USB
+24V
CAN H
GND
CAN L
GND
IN 1
IN 2
IN 3
IN 4
IN 8
IN 5
IN 6
IN 7
SPK
GND
OUT
24V
TERM
ON
OFF
SD-CARD
USB
+24V
CAN H
GND
CAN L
GND
IN 1
IN 2
IN 3
IN 4
IN 8
IN 5
IN 6
IN 7
SPK
GND
OUT
24V
FD1600
FD1600
FD1600
FD1600 v.2.03 EN
Installation
In car
Unit ID: CAR2
Main mode: Normal
Term: off
Top oor
Unit ID: Floor(X)
Main mode: Normal
Term: off
Bottom oor
Unit ID: Floor1
Main mode: Normal
Term: on

12
...
FD1600 v.2.03 EN
Installation
FD1600
Term.:ON FD1600
Term.:OFFFD1600
Term.:ON
Start-up
Error codes
When an exception or internal fault is detected, the display shows an
error code. The error code is always two characters, starting with the
full stop punctuaction mark ".".
* If conflicting ID's one or more units may exist with same ID. All ID's
must be unique, and it is up to the installer to ensure the system
integrity. When these errors are detected, a reset or power cycle
must be performed to clear the error.
CAN bus
CAN bus speed is fixed at 125 kBit/s. The CAN BUS must be
terminated in each end. When the bus is active and connected, two
units have enabled the termination. All other units connected to the
bus have termination disabled. If a CAN absolute position encoder
or an external CAN position unit (i.e. IPS unit) is used, also check
and set bus termination of these units.
If no oor trigger is received
or generated, the display
shows the user settable error
text. This text may also be a
symbol (i.e. the STOP symbol).
The display starts "empty" with no text on the display. After internal
initializtion, functionality starts and sends status for any active
inputs to other connected display.
If a speaker is connected it is possible to hear the start-up sound.
• No sound = no memory card inserted or recognized
• Two short beeps = memory card recognized and usable
• One long beep = memory card inserted, but unusable
(try removing and re-insert)
The following error codes are dened
.0 undened error
.1 more than one unit is set as oor generator
.2 a unit with same ID exists *
.3 main mode not set (or out of bounds)
.4 position too high
.5 position too low
.6 no positions set (or learned)
.7 ID not valid (out of bounds) *
.8 encoder heartbeat fault (encoder lost)
.T IPS not ready for learning trip.
.A program mode active.

13
TERM
ON
OFF
SD-CARD
USB
+24V
CAN H
GND
CAN L
GND
IN 1
IN 2
IN 3
IN 4
IN 8
IN 5
IN 6
IN 7
SPK
GND
OUT
24V
FD1600 v.2.03 EN
Installation
Menu buttons There are two menu buttons, which are located on the back of the unit.
Using the menu buttons
Pressing the two menu buttons simultaneously will:
• Enter conguration mode, or
• Conrm selection.
Pressing one of the menu buttons at a time will:
• Scroll through the current menu options.
The menu options will be presented and loops around either
clockwise (if pressing the right menu button) or counterclock-
wise (if pressing the left menu button).
The SLProFD1600 need to be
used in order to access all of
the installation options.
Download SafeLine Pro from:
www.safeline-group.com via
the SafeLine Pro product page
Menu buttons

14
UNIT*
DISP
(Display)
START HERE
FD1600 v.2.03 EN
Installation
Main mode
9 E-CA: External (IPS)
9 E-BL: External position encoder with BLE
9 NRM: Normal (not oor generator)
9 DEC1: Decimal (oor 1 -8)
9 DEC2: Decimal (oor 9 - 16)
9 BIN: Binary
9 GRY: Gray code
9 CAN: CAN Encoder
Floor count (total)
9 1-63
ID Unit (installation)
Sets the installation point of the unit. All units
connected to the BUS must have unique ID's
(two SYS or two CAR1 units are not allowed).
9 CAR1, CAR2, Floor 1-63, SYS (System)
Arrival trigger
9 SLW: CAR reduce
9 STP: CAR stop
9 NON: None
9 INP: Input
9 FLR: Floor change
9 ARW: Arrow change
Arrival sound
9 NON: none
9 3T: Three tone
9 EN: EN81-70 (according to regulations)
WAV: Wave
Menu tree
structure
Brightness
Sets the display brightness
when showing text in the display.
9 1-20
Orientation
Sets the orientation mode, where "0" is landscape
mode. The menu is always shown in same way,
regardless of the settings in the orientation.
9 0, 90, 180, 270
Volume
Sets the speaker volume when playing
WAVE-les and/or built in system sounds.
9 1-20
Language
Selected language sets the displayed xed
system messages. The language in the menu is
xed, and always English.
9 ENG, GER, FRE, SWE, DAN, USR (user language)

15
INP
TXT
LRN
FD1600 v.2.03 EN
Installation
Menu tree
structure
Floor 1-63
(select text)
Only accessible if main mode is NOT set to "Normal". In this menu
select the oor to change its text. Press both buttons, and rst
character of the oor text ashes. Adjust the character, and
press both buttons again. Now the next character ashes.
Editing is ended if an empty character is selected or three character
are entered. Each time a oor text is ended, it is possible to select a
new oor. Return to main menu by pressing both buttons for 2 seconds.
(Only accessible if not all inputs are predened. That is for example
if oor count is set to 8,"Unit > Main Mode" is set to "Decimal" and
all inputs are predened as individual oor generators.) Each time
an input function is selected, it is possible to select a new input.
Return to main menu by pressing both buttons for 2 seconds.
Input 1-8
(select function)
(Only accessible if "Unit > Main Mode" is set to "CAN Encoder" or
"External".) Floor 1 is always the lowest oor. “ENTER” stores
encoder position for selected oor. The learning process must
ALWAYS be in correct sequence 1 -> 2 -> 3 and up to maximum
oor position. Learning sequence is canceled by holding both
buttons for 2 seconds. Encoder resolution is only accessible if
encoder is selected as “main mode”.
Start
9 NO, YES
(Learn)***
(Text)
(Input)
(Only available if Main mode and ID unit is chosen)

16
DEF
OFF
FD1600 v.2.03 EN
Installation
* Sub menu items change, depending on the selected "Main Mode"
** Each time a oor text/Input function is entered, it is possible to
select a new oor. Return to main menu by pressing both buttons
for 2 seconds.
*** Floor 1 is always the lowest oor. "ENTER" stores encoder
position for selected oor. The learning process must ALWAYS be
in correct sequence 1 > 2 > 3 and up to maximum oor position.
Learning sequence is cancelled by holding both buttons for 2
seconds. Encoder resolution is only accessible if encoder is
selected as "main mode".
(Turn menu off and return to normal operation. Choose if parameter
must be saved.)
Save
NO, YES
Save
9NO, YES
Menu tree
structure
(default settings)
Menu
Function

17 FD1600 v.2.03 EN
Installation
Floor texts are user programmable and holds up to 4 characters.
Long oor text
If a long text is wanted, a user message can be assigned and used
as a oor text. Write “!1” to “!10” in the oor text eld, and write the
desired text in the according user text eld.
Symbol instead of text
It is also possible to get some xed symbols instead of oor text.
Following symbols are dened:
“!E0” Not in use
“!E1” STOP sign
“!E2” Not in use
“!E3” Not in use
“!E4” Not in use
“!E5” symbol “1/2”
“!E6” symbol “2/3”
“!E7” symbol “3/4”
“!E8” symbol “4/5”
Fixed messages
Fixed messages are handled as one, but actually divided in two
parts. First part (and highest priority) is the system messages.
System messages are xed and cannot be changed. System
messages automatically change depending on the selected
language.
Second part is the user messages and is set up via external
programming tool. It is also possible to select if message has to
roll once in display, or it has to be active as long as the input is
activated. Highest priority is “System message 1”, lowest priority is
“User message 10”.
Display fonts
The xed messages always
show the complete text, even
if the input that triggered the
text is inactive before text has
rolled minimum one round.
Floor texts
FD1600 has dened four usable fonts:
0 = Font 0, auto font selection
1 = Font 1, 8 x 10 pixel (normal)
2 = Font 2, 6 x 8 pixel (small)
3 = Font 3, 5 x 7 pixel (smaller)
4 = Font 4, 4 x 5 pixel (very small)
It is possible to select different font for static/steady texts (i.e. oors)
and rolling texts.

18 FD1600 v.2.03 EN
Startup
It is possible to enable both xed arrows and moving (scrolling)
arrows. Fixed arrows are usually used when display is mounted
in the hall (oor 1-63). Moving arrows are usually used in the car
(CAR1 and CAR2). It is possible to have both arrow types enabled
at the same time (not preferred in HALL displays).
Arrows
Both xed and moving arrow use following arrow styles:
Style 0 Arrow with spike and tail (old style)
Style 1 6 LED rows, 12 dots wide (standard style at spike)
Style 2 5 LED rows, 10 dots wide (standard style at spike)
Style 3 4 LED rows, 8 dots wide (standard style at spike)
Style 4 3 LED rows, 6 dots wide (standard style at spike)
Style 5 2 LED rows, 4 dots wide (standard style at spike)
Fixed arrows
Fixed arrows indicate direction of current travel, or intended
direction of next travel.
Moving arrows
The moving arrow normally have a much lower brightness than the
oor names (text), resulting in a 3D effect. If preferred, the brightness
can be set at a higher level.
Fixed arrows CAR
0 = Disabled
1 = Superimposed steady
2 = Superimposed ash
3 = Superimposed fade
Fixed arrows FLOOR
0 = Disabled
1 = Steady (enabled)
Fixed arrows, style
0 = Old style
1-5 = Solid arrow
Fixed arrows, position
0 = Automatic
1 = Middle
2 = Right
3 = Left
4 = Top
5 = Bottom
Moving arrow
0 = Off
1 = CAR only
2 = FLOOR only
3 = both CAR and FLOOR
Moving arrow, style
0 = Old style
1-5 = Solid arrow
Moving arrow, position
0 = Automatic (standard)
1 = Middle
2 = Left
3 = Right

19 FD1600 v.2.03 EN
Startup
Boot menu Holding down one of the menu buttons while power is connected
displays a “boot menu”. The specic boot menu or function is
selected when button is released. If button was pressed by mistake,
release the button while unit show “RDY”, or keep pressing the button
until display continues to normal working state (8-10 seconds).
“RDY”
The unit is ready and no changes are made. In lower line the current
rmware version is shown.
“CFG”
Conguration is loaded from SD card, this can be used to copy a
conguration from one unit to another.
“BTL”
Bootloader is activated.
“CLR ALL”
All parameters are cleared to factory defaults.
Arrival
Both arrival trigger and arrival sound is programmable. The arrival
sound is heard on oor displays and SYS unit if used. No arrival
sound on CAR units.
Trigger
It is possible to make arrival trigger on a number of events, but not
all combinations make sense. As an example “CAR reduce” only
make sense when using either external position device (IPS) or an
encoder. “External input” only make sense if we also dene and use
an external input.
Sound
Some basic sounds are available if no SD card with sounds is used.
If more sophisticated sounds are required, an SD card with sounds
must be installed, and the sound setup must be performed by an
external programming tool (computer or smartphone application).
If only one of the menu buttons is pressed, the menu for volume
is entered directly. The volume can then be adjusted up or down
as desired. If both buttons are pressed, the main menu is entered.
When both buttons are pressed and a menu is already selected,
the next submenu is shown. When end is reached (no more
submenus), the main menu is shown again. If both buttons are
pressed for 2 seconds in a submenu, the main menu is shown.
Menu buttons
“UP” = increase item / value / menu
“DOWN” = decrease item / value / menu
“ENTER” = both buttons pressed = accept value or enter menu/sub-menu
“CANCEL”
= both buttons pressed for 2 seconds
Setup menu

20 FD1600 v.2.03 EN
Conguration
Learning is started with one of the following:
• SafeLine CONNECT app
• PC
• Menu buttons on the FD1600
1. Start the learning trip at the lowest level. Drive to the next level.
2. Make a stop at all levels. The position is saved automatically at each stop.
3. When the highest level is reached and the lif t is changing direction,
the learning trip is nished.
4. The IPS returns to normal functions.
Learning mode
with IPS
Menu content change depending on selected values in “Unit”
main menu.
Content change 1:
Main menu “Floor Text” only visible if “Main Mode” is not set to
“Normal”
Content change 2:
Main menu “Learn” only visible if encoder or external position is
selected as “Main Mode”
(Unit / Main mode / Encoder)
Content change 3:
Main menu “Inputs” are only visible if all inputs are not predened
(e.g. if oor count is set to 8 and main mode is decimal, all inputs
are predened as individual oor generators).
Dynamic menus
Expected directory structure:
X:\CFG = conguration directory
X:\WAV = wave les directory
X:\FIRMWARE = directory for rmware update
CFG directory
This directory holds a copy of the conguration, and also a copy of
the sound index le.
WAV directory
This directory holds all sound les, including user sound les.
FIRMWARE directory
This directory is not in use yet.
Memory card
The SLPro FD1600 need to
be used in order to access all
of the installation options.
Download SLPro from:
www.safeline-group.com
Other manuals for FD1600
1
This manual suits for next models
1
Table of contents
Other Safeline Monitor manuals