Safeline FD4-CAN User manual

www.safeline-group.com
03.2019 © 2019 SafeLine and all the SafeLine products and
accessories are copyrighted by law.
Reliability – brought to you from Tyresö, Sweden
ON
Floor display
FD4-CAN v.2.01 EN
FD4-CAN
Manual

2FD4 -CAN v.2.01 EN
Introduction
Content Introduction
Technical data 3
General information 4
Installation
Wiring instructions 5
LED 6
Settings 7
Conguration
Programming 8
Conguration 9
Certicate
Programming 10

3
FD4-CAN
FD4 -CAN v.2.01 EN
Introduction
Power: 19-28 VDC
Size (H x W x D): 61 x 80 x 25 mm
Current consumption, standby: 120 mA / 24 VDC
Max output current on each output: 200 mA
Max output current for the card: 1 A / 24 VDC
Power input: 20-30 VDC
Input current on each input: 8 mA / 24 VDC
SD-card: Kingston and Verbatin 1, 2 or 4 GB
Speaker output: 0,6Wat8Ω
0,3Wat16Ω
All outputs are shortcut protected.
Technical data

4FD4 -CAN v.2.01 EN
Introduction
This unit was built with state-of-the-art technology and to
generally recognised safety related technical standards currently app-
licable. These installation instructions are to be followed by all people
working with the unit, in both installation and maintenance.
It is extremely important that these installation instructions are made
available at all times to the relevant technicians, engineers or servicing
and maintenance personnel. The basis prerequisite for safe handling
and trouble free operation of this system is a sound knowledge of the
basic and special safety regulations concerning conveyor technology,
and elevators in particular. The unit may only be used for its intended
purpose. Note in particular that, no unauthorised changes or additions
may be made inside the unit or individual components.
Exclusion of liability
The manufacturer is not liable with respect to the buyer of this product
or to third parties for damage, loss, costs or work incurred as a result of
accidents, misuse of the product, incorrect installation or illegal chang-
es, repairs or additions. Claims under warranty are likewise excluded in
such cases. The technical data is the latest available. The manufacturer
accepts no liability arising from printing errors, mistakes or changes.
Declaration of conformity
Download ”The declaration of conformity” at our website:
www.safeline-group.com
Safety Precautions!
- Only trained professionals, who are authorised to work on the equip-
ment,shouldinstallandcongurethisproduc t.
- This quality product is dedicated for the lift industry. It has been
designedandmanufacturedtobeusedforitsspeciedpurposeonly.
If it is to be used for any other purpose, SafeLine must be contacted in
advance.
-Itshouldnotbemodiedoralteredinanyway,andshouldonlybe
installedandconguredstric tlyfollowingtheproceduresdescribedin
this manual.
- All applicable health and safety requirements and equipment
standards should be considered and strictly adhered to when installing
andconguringthisproduct.
-Afterinstallationandcongurationthisproductandtheoperation
of the equipment should be fully tested to ensure correct operation
before the equipment is returned to normal use.
Electrical and electronic products may contain materials, parts and
units that can be dangerous for the environment and human health.
Please inform yourself about the local rules and disposal collection
system for electrical and electronic products. The correct disposal of
your old product will help to prevent negative consequences for the
environment and human health.
General
information

5
ON
20-30 VDC
CAN H
CAN SHLD
CAN L
0V
IO4
IO3
IO2
IO1
20-30 VDC
CAN H
CAN SHLD
CAN L
0V
SPK
TERM
SD-CARD
RUN ERR
0 V
CAN L
CAN H
20-30 VDC
0 V
CAN L
CAN H
20-30 VDC
0 VDC
FD4 -CAN v.2.01 EN
Installation
This unit was built with state-of-the-art technology and to
generally recognised safety related technical standards currently app-
licable. These installation instructions are to be followed by all people
working with the unit, in both installation and maintenance.
It is extremely important that these installation instructions are made
available at all times to the relevant technicians, engineers or servicing
and maintenance personnel. The basis prerequisite for safe handling
and trouble free operation of this system is a sound knowledge of the
basic and special safety regulations concerning conveyor technology,
and elevators in particular. The unit may only be used for its intended
purpose. Note in particular that, no unauthorised changes or additions
may be made inside the unit or individual components.
Exclusion of liability
The manufacturer is not liable with respect to the buyer of this product
or to third parties for damage, loss, costs or work incurred as a result of
accidents, misuse of the product, incorrect installation or illegal chang-
es, repairs or additions. Claims under warranty are likewise excluded in
such cases. The technical data is the latest available. The manufacturer
accepts no liability arising from printing errors, mistakes or changes.
Declaration of conformity
Download ”The declaration of conformity” at our website:
www.safeline-group.com
Safety Precautions!
- Only trained professionals, who are authorised to work on the equip-
ment,shouldinstallandcongurethisproduc t.
- This quality product is dedicated for the lift industry. It has been
designedandmanufacturedtobeusedforitsspeciedpurposeonly.
If it is to be used for any other purpose, SafeLine must be contacted in
advance.
-Itshouldnotbemodiedoralteredinanyway,andshouldonlybe
installedandconguredstric tlyfollowingtheproceduresdescribedin
this manual.
- All applicable health and safety requirements and equipment
standards should be considered and strictly adhered to when installing
andconguringthisproduct.
-Afterinstallationandcongurationthisproductandtheoperation
of the equipment should be fully tested to ensure correct operation
before the equipment is returned to normal use.
Electrical and electronic products may contain materials, parts and
units that can be dangerous for the environment and human health.
Please inform yourself about the local rules and disposal collection
system for electrical and electronic products. The correct disposal of
your old product will help to prevent negative consequences for the
environment and human health.
General
information
Wiring
instructions
CAN-bus end
termination resistance
120Ωifshorted
Micro SD-card
MAX
4GB (HC)

6
ON
20-30 VDC
CAN H
CAN SHLD
CAN L
0V
IO4
IO3
IO2
IO1
20-30 VDC
CAN H
CAN SHLD
CAN L
0V
SPK
TERM
SD-CARD
RUN ERR
LED
FD4 -CAN v.2.01 EN
Installation
Green LED steady:
CAN OK
Red LED steady:
CAN error
Heartbeat
Flashing 2Hz

7FD4 -CAN v.2.01 EN
Installation
Settings
General settings are made by
CAN-wizard. Settings and
audio les can be saved on
the micro SD-card.
Micro SD-card
The memory card contains the following folders:
CFG
WAV
FIRMWARE
CFG
InCFGiswheretheleCONFIG.FD4islocated.Ithasallthesettings
of the unit. If an empty memory card is inserted, the unit will by
defaultcreateacatalogandwritea“CONFIG.FD4-le.*
WAV
InWAViswhereanysoundles,usedbytheunit,arelocated.
AudioleshavetobeintheWAVformat(16bit,16kHzmono),and
correspond to the search path given in CAN-wizard.
FIRMWARE
When needed updated software can be added here to update the unit.
Update of software:
1. Disconnect the power to FD4-CAN.
2. Insert a micro SD card, that has the new software located in the
folder named FIRMWARE
for eg. “X:\FIRMWARE\FD4-CAN-03_1.0.0.bin”
3. Press and hold the down-button on the backside of the FD4-
CAN, and power up the unit. Hold the down-button until the
upper part of the display reads “BLT” and the lower half reads
the software version. Then release the down-button. The unit
will now start.
*Fortransferofsettingsbetweenunitsseechapter“ReplacingFD4-CAN”.

8
ON
20-30 VDC
CAN H
CAN SHLD
CAN L
0V
IO4
IO3
IO2
IO1
20-30 VDC
CAN H
CAN SHLD
CAN L
0V
SPK
TERM
SD-CARD
RUN ERR
ON
20-30 VDC
CAN H
CAN SHLD
CAN L
0V
IO4
IO3
IO2
IO1
20-30 VDC
CAN H
CAN SHLD
CAN L
0V
SPK
TERM
SD-CARD
RUN ERR
FD4 -CAN v.2.01 EN
Conguration
Programming Save settings from FD4-CAN on to a micro SD-card
1. Disconnect the power to FD4-CAN.
2. insert an empty micro SD-card into the unit.
3. Power the FD4-CAN. The transfer starts automatically.
Notethatsoundlescannotbetransferedthisway,astheynever
are stored directly onto the FD4-CAN.
Replacing FD4
1. Disconnect the power to new unit.
2. Insert the micro SD-card from the old unit into the new unit.
3. Press and hold the down-button on the backside of the FD4-
CAN, and power up the unit. Hold the button until the upper
part of the display reads “CFG” and the lower half reads the
software version. Then release the button. The unit will now
reboot.
Micro SD-card
Buttons

9FD4 -CAN v.2.01 EN
Conguration
Volume,LED-brightnessandnode-IDareconguredwiththe
buttons on the back of the unit. If no selection has been made after
acoupleofsecondstheunitwillleavethe“Settings-menu*and
return to normal mode.
Do not change Node-ID! Correct node-ID is set at delivery.
Conguration
FD4-CAN
normal mode
Hold both buttons for 2 seconds
Mode to set message volume.
Press up/down to set message volume
Press both buttons simultaneously
Mode to set LED-brightness
Press up/down to set LED-brightness
Hold both buttons a couple of seconds
Mode to set Node-ID
Press up/down to set FD4-CAN
Press both buttons simultaneously
Unit will reboot
Mode to set button volume
Press up/down to set button volume
Press both buttons simultaneously

Your partner in lift safety
Antennvägen 10, 13548 Tyresö, Sweden
+46 (0)8-447 79 32, www.safeline-group.com
EU Declaration of Conformity
Product: Floor display
Type / model: FD4
Article no: *FD4, *FD4_BLUE, *FD4_GREEN, *FD4_YELLOW, *FD4-MRL
*FD4_PLATESPK, *FD4_PLATESPK BL/GR/YL
*FD4_PLATESPKS, *FD4_PLATESPKS BL/GR/YL
*FD4-CAN, *FD4-CAN-BLUE
*FD4-CAN-PSP, *FD4-CAN-PSP-BL
*FD4-CAN-PSPS, *FD4-CAN-PSPS-BL
Manufacturer: SafeLine Sweden AB
Year: 2017
We herewith declare under our sole responsibility as manufacturer that the products referred to
above complies with the following EC Directives:
Directives
Electro Magnetic Compatibility: 2014/30/EU
RoHS 2: 2011/65/EU
Standards applied
EN 12015:2014 EMC: Emission, Electromagnetic compatibility
EN 12016:2013 EMC/Lifts: Immunity, Electromagnetic compatibility
EN 50581:2012 RoHS: Technical doc. for assessment of restriction of RoHS.
Tyresö, 2017-04-07
Lars Gustafsson,
Technical Manager, R&D , SafeLine Group


www.safeline-group.com www.safeline-group.com
SafeLine Europe
Industrieterrein 1-8 · 3290 Diest · Belgium
Support: +32 (0)4 85 89 08 95
SafeLine Deutschland GmbH
Kurzgewannstraße 3 · D-68526 Ladenburg · Germany
SafeLine Norway
Solbråveien 49 · 1383 Asker · Norway
SafeLine Denmark
Erhvervsvej 19 · 2600 Glostrup · Denmark
SafeLine Headquarters
Antennvägen 10 · 135 48 Tyresö · Sweden
Support: +46 (0)8 448 73 90
SafeLine Group UK
Unit 47 · Acorn Industrial Park · Crayford ·
Kent · DA1 4AL · United Kingdom
Other manuals for FD4-CAN
2
Table of contents
Other Safeline Monitor manuals