Salto ESDB User manual

Publications of SALTO SYSTEMS S.L. are protected by copyright and all rights are reserved.
SALTO SYSTEMS publications may not be reproduced in any form or by any means without written permission from the copyright owner.
\\USER MANUAL
SALTO ESDB | Universal Energy Saver
The Universal Energy Saving Device allows efcient
energy control and management in residential and
hospitality environments.
The system permits energy to be connected once a
person’s presence is detected in the controlled area or
room.
Universal Energy Saver
ESDB

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
2
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
NON - CARD ENERGY SAVER
1. INTRODUCTION 5
2. INSTALLATION 5
3. OPERATION 8
4. CLEANING AND MAINTENANCE 10
5. RESPECTING THE ENVIRONMENT 10
FLUSH MOUNTED MOTION DETECTORS
1. INTRODUCTION 13
2. INSTALLATION 14
3. CLEANING AND MAINTENANCE 16
4. RESPECTING THE ENVIRONMENT 17
5. TECHNICAL DATA 17
SURFACE MOUNTED MOTION DETECTORS
1. INTRODUCTION 21
2. INSTALLATION 22
3. CLEANING AND MAINTENANCE 24
4. RESPECTING THE ENVIRONMENT 25
5. TECHNICAL DATA 25
DOOR/ WINDOW DETECTOR
1. INTRODUCTION 29
2. INSTALLATION 30
3. DETECTOR CONFIGURATION 32
4. CLEANING AND MAINTENANCE 33
5. RESPECTING THE ENVIRONMENT 34
6. TECHNICAL DATA 34

Publications of SALTO SYSTEMS S.L. are protected by copyright and all rights are reserved.
SALTO SYSTEMS publications may not be reproduced in any form or by any means without written permission from the copyright owner.
//USER MANUAL
SALTO ESDB | Universal Energy Saver
The ESDB Energy Saving Device allows efcient
energy control and management in residential and
hospitality environments.
The system permits energy to be connected once a
person’s presence is detected in the controlled area or
room.
Universal Energy Saver
Non-card energy saver

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
4
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
Read the following instructions carefully before installing the product and keep
this documentaiton for future reference.
General warnings and instructions to ensure the correct operation of the product
in your installation:
1. The installation and use of the product must be done in accordance with the
instructions included in this document.
2. Correct operation of the unit is the client’s responsability. SALTO is not responsible
for any damages resulting from the incorrect use of the product.
3. If a unit has failed to function correctly and/or has been damaged, please contact
your SALTO dealer and do not try to repair and reinstall the unit yourself.
4. This device must be used only in indoor environments.
IMPORTANT! Do not expose this device to rain, dripping water,
humidity, high temperatures (above 50ºC) or dust.
Product guarantees will be made invalid if this system is used incorrectly and not in
accordance with the directions explained in the product documentation, including if the
product has in any way been opened and/or manipulated.

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
5
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
1. INTRODUCTION
1.1 Brief description
The ESDB Energy Saving Device allows efcient energy control and management
in residential and hospitality environments. The system will manage the room power
according to the room presence status.
External detectors (Motion Detector, Door/Window Detector) are needed to complete
the system.
1.2 Material included
The basic system is comprised of the following equipment:
• 1 Energy Saver
• 1 Motion Detector
• 1 Door/Window Detector
• 1 Cards kit
• User manual
2. INSTALLATION
2.1 Installation safety information
Please read the instructions included here before starting, and follow them carefully
prior to installation and using the Energy Saver.
1. Use the device only with the power supply indicated on the product documentation.
If you are unsure about the type of power supply used on your installation, please
contact your electric company.
2. Be sure to turn off the power before performing any maintenance or modications to
the installation.
3. Any incorrect connections can result in personal injury an/or can cause irreparable
damage to the product.
4. The device’s electrical connections must follow ofcial standards and valid legal
directives and requirements.
5. The installation must include a device that cuts the power to the Energy Saver in
the case of any possible spike to the device due to a malfunction.

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
6
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
2.2 Technical characteristics
2.3 Installation process
Ensure that the cables used in the electrical installation of the device are no connected
to the electrical supply during the installation process.
2.3.1 Mechanical assembly
This unit is designed to be mounted on a DIN rail.
RF model reference ESDB
Description: Wireless Non-card Energy Saver
Power supply: 110 - 230 Vca.
Consumption: Nominal 30 mA, Maximum 50 mA (230 Vac)
Frequency 50 – 60 Hz.
Output relay: 2 Relays (free potential with 2 contacts NO / NC)
Cutting power:
12 A, 230 V~,cos =1
8 A, 230 V~,cos = 0,6
Incandescent max. load: 10 A.
Halogen max. load: 10 A.
Cutting power max. in NC contact:
12 A, 230 V~,cos =1
8 A, 230 V~,cos = 0,4
Incandescent max. load.10 A.
max. Halogen 10 A.
Dimensions: 90,2x53,30x57,50mm
Weight: 183g
Housing PC/ABS reproof (according to norm UL94V-0)
Pilots: Tricolour LED (amber, red, green)
Temperature range: 0º - 50º

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
7
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
2.3.2 Connection diagram
The device electrical connections must follow the local standards and the ofcial
regulations.
Connection Diagram 1
* An external contactor may be needed if the connected load exceeds the maximum
ESD power requirements.

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
8
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
2.3.3Conrmingcorrectinstallation
With the mechanical and electrical assembly completed, you can now test the device to
ensure that it is ready and can be put into use.
1. Check that the Energy Saver is connected according to the connection diagram 1
2. Ensure that the unit is plugged into a connected electrical line.
3. Conrm that the LED shows a continuous amber light.
3. OPERATION
The Energy Saver must be plugged into the electrical grid as explained in Electrical
Characteristics (2.2). Each Energy Saver device has two output relays wherein one
is used to activate electrical current (such as lighting) and the other is used for other
applications (such as air conditioning).
Considerations:
The room is considered as empty.
The main door is equipped with a door detector.
The room is equipped with a motion detector.
• The main door is open and the relay 1 is activated. The guest can now control the
lighting.
• Relay 2 is activated as soon as the motion detector detects the guest.
• The room is occupied.
• If no door is detected (open/close - a person entering/leaving the room), both relays
will be maintained activated.
• If someone leaves the room, the Door Detector will register the door closing and will
communicate this to the Energy Saver. The Motion Detector will start searching for
motion as per the conguration set-up (15 or 60 minutes for relay 1 and 15 minutes
for relay 2).
• If no motion is detected during the setup time period, the Energy Saver will turn the
lighting (Relay 1) and the air conditioning (Relay 2) off until motion is again detected
in the room. The Relay 2 timing is always xed at 15 minutes.
• If a Window Detector registers that a window has been opened for more than 30
seconds, it will communicate this to the Energy Saver and Relay 2 will be turned off,
thus deactivating the air conditioning or heating systems. This will also result if the
main door is left open for more than 30 seconds.
3.1 Synchronizing the Energy Saver with Motion and Door/Window Detectors
To synchronize an Energy Saver to its Detectors, follow these steps:
1. Present the Sensor Synchronizing Card to the Energy Saver, putting the device
into Synchronizing Mode.

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
9
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
2. With the Energy Saver in Synchronizing Mode, press the Detector’s inner button
(see Detector section).
3. The Detector’s LED will now go red, and the Detector and Energy Saver will now
begin to synchronize. When thesynchronization process has been successfully
completed, the Detector will blink red for a couple of seconds, followed by four slow
blinks and the LED will go off.
4. Repeat these steps for all the Detectors that need to be synchronized to the same
Energy Saver.
5. Once all the Detectors are synchronized, remove the Synchronizing Card from the
Energy Saver to exit Synchronizing Mode.
Please note that this same Synchronization Card can be used for the synchronization of
each room’s devices.
IMPORTANT! Synchronize each detector one at a time. Do not synchronize
several energy savers at the same time.
3.2 Special card kits
The following cards are included in the kit:
• Synchronizing Card. It is used to put an Energy Saver in Synchronizing Mode
(LED blinks amber) and synchronize with the Detectors in the same room.
• Sensor Deleting Card. It is used to desynchronize a room’s Energy Saver from the
Detectors in the same room. (LED blinks green to indicate the number of Detectors
desynchronized from the Energy Saver.) The Energy Saver is now ready to be
synchronized with new Detectors.
• Motion Detector Time Card (15 min). It is used to change the lightning (relay 1)
motion detection time to 15 minutes. Once a door is closed, the Motion Detector
search for motion in the room for the next 15 minutes before shutting off.
• Motion Detector Time Card (60 min). It is used to change the lightning (relay 1)
motion detection time to 60 minutes. Once a door is closed, the Motion Detector
search for motion in the room for the next 60 minutes before shutting off electricity.

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
10
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
4. CLEANING AND MAINTENANCE
Although the Energy Saver does not require regular maintenance, it should be gently
cleaned occasionally with a damp cloth. Do not use a stream of water or steam.
5. RESPECTING THE ENVIRONMENT
This device is made of recyclable materials. Please follow your local ordinances
regarding the correct disposal of waste. Recycling helps reduce the consumption of
raw materials and of environmental contamination.

Publications of SALTO SYSTEMS S.L. are protected by copyright and all rights are reserved.
SALTO SYSTEMS publications may not be reproduced in any form or by any means without written permission from the copyright owner.
\\USER MANUAL
SALTO ESDB | Universal Energy Saver
The ESDB “cardless” energy saver is an electronic
device that allows energy control and management in
residential and hospitality environments.
The system permits energy to be connected once a
person’s presence is detected in the controlled area or
room.
Universal Energy Saver
ESDBRD - Flush Mounted Motion Detector

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
12
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
Read the following instructions carefully before installing the product and keep
this documentaiton for future reference.
General warnings and instructions to ensure the correct operation of the product
in your installation:
1. The installation and use of the product must be done in accordance with the
instructions included in this document.
2. Correct operation of the unit is the client’s responsability. SALTO is not responsible
for any damages resultign from the incorrect use of the product.
3. If a unit has failed to function correctly and/or has been damaged, please contact
your SALTO dealer and do not try to repair and reinstall the unit yourself.
4. This device should be used only in indoor environments.

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
13
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
1. INTRODUCTION
1.1 Brief description
The adjustable ush mounted volumetric sensor is a passive infra-red device that
detects motion inside the room.
The unit is self-contained and is powered by a 3V CR123A lithium battery (not
rechargeable).
1.2 Material included
• Flush mounted volumetric sensor.
• Instructions and start-up manual

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
14
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
2. INSTALLATION
The ush mounted volumetric detector is always installed on the ceiling of the room*.
The device is installed by hooking to the ceiling with the tabs.
It is necessary to bore a 75mm hole in the ceiling in order to insert the detector.
The detector’s installation position must be taken into account. Detection coverage is
shown below to help positioning. It may be necessary to install more than one detector
per room.
It detects motion as soon as any movement above a speed of 1 m/s is detected in the
detection zone..
* Basic Principles
PaPIRs is a pyroelectric infrared sensor that detects variations in infrared rays.
However, it may not detect in the following cases: lack of movement, no temperature
change in the heat source. Besides, it could also detect the presence of heat sources
otherthanahumanbody.Efciencyandreliabilityofthesystemmayvarydependingon
actual operating conditions:
1) Detecting heat sources other than the human body, such as:
a) Small animals entering the detection area
b) When a heat source for example sun light, incandescent lamp, car headlights etc, or
strong light beam hit the sensor regardless inside or outside the detection area.
c) Sudden temperature change inside or around the detection area caused by hot or
coldwindfromHVAC,orvaporfromthehumidier,etc.
2) Difculty in sensing the heat source
a) Glass, acrylic or similar materials standing between the target and the sensor may
not allow a correct transmission of infrared rays.
b) Non-movement or quick movements of the heat source inside the detection area.
3) Expansion of the detection area
In case of considerable difference in the ambient temperature and the human body tem-
perature,detectionareamaybewiderapartfromthecongureddetectionarea.

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
15
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
2.1 Dimensions
The diameter and height dimensions of the ush mounted volumetric sensor are shown
in the following images.
2.2 Installation process
The ush mounted volumetric sensor should be installed in the following order:
1. Mark the position of the hole to be drilled.
2. Drill a hole with a 75mm crown.
3. Synchronise the sensor and the Energy Saver.
Present the Sensor Synchronising Card on the energy saver which will then
remain in synchronisation mode until the card is removed again.
Press the Sensor’s internal pushbutton with your hand while the Sensor Syn
chronising Card is on the energy saver. The red pilot light will come on.
The sensor and the energy saver will then try to synchronise. Synchronisation
is correct when the red sensor ashes very quickly for about ve seconds. The
red pilot light must go off then.
Repeat the same procedure with all the sensors in the same room that must be
synchronised with the same energy saver.
Remove the card from the energy saver once all sensors have been synchroni
sed.
4. Position the ush mounted volumetric sensor in the ceiling and secure it using the
two tabs.
37cm
66 cm
85cm

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
16
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
2.3 Desynchronization of detectors
Sensors are desynchronised when the sensor delete card is presented to the energy
saver. The energy saver deletes the list of all synchronised sensors.
Desynchronisation is necessary in the following cases:
- When one of the sensors has to be removed from the room.
- When a sensor fails and needs to be replaced.
The room sensors must always be resynchronised with the energy saver after desyn-
chronising.
Desynchronisation is NOT necessary in the following cases:
• When changing the sensor batteries.
• When adding a new sensor to the room.
3. MAINTENANCE AND CLEANING
To keep your device functioning properly, ensure that the optic is clean and nothing is
glued or xed to it.
Batteries should be replaced approximately every 2 years or sooner if the detector light
starts blinking red.
3.1 Battery replacement
When the battery needs to be changed, the Motion Detector LED will ash red three
times every eight seconds.

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
17
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
4. RESPECTING THE ENVIRONMENT
Dispose of used batteries correctly, in an authorized collection point, and never in the
general trash.
5. TECHNICAL DATA
ESDBRD-WIRELESS ADJUSTABLE RECESSED VOLUMETRIC SENSOR FOR ENERGY SAVER
REFERENCE SVExIxS
POWER 1 CR123A 3 V battery
BATTERY LIFE 5 years (Mean consumption 18uA, Maximum 20mA)
COMMUNICATIONS Wireless 2.4 GHz, IEEE 802.15.4
COMMUNICATIONS COVERAGE 10m (Maximum distance to the energy saver)
INTERFACE Red LED
TEMPERATURE/HUMIDITY RAN-
GE
Temperature: -40° to 160°
TECHNOLOGY Passive infra-red detector.
DETECTION COVERAGE For a height of 12 m, an area of (32x28) m
ASSEMBLY HEIGHT Maximum height 12 m
THERMOSTAT PRECISION Temperature: ±0.5° (15° to 40°), ±1° (0° to 60°)
DIMENSIONS 85 mm x 37 mm
WEIGHT 90 g

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
18
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
Notes:

Publications of SALTO SYSTEMS S.L. are protected by copyright and all rights are reserved.
SALTO SYSTEMS publications may not be reproduced in any form or by any means without written permission from the copyright owner.
\\USER MANUAL
SALTO ESDB | Universal Energy Saver
The ESDB “cardless” energy saver is an electronic
device that allows energy control and management in
residential and hospitality environments.
The system permits energy to be connected once a
person’s presence is detected in the controlled area or
room.
Universal Energy Saver
ESDBMD - Surface Mounted Motion Detector

ESDB-GUIDE-ENG- 02-21
www.saltosystems.com
SALTO Systems - Universal Energy Saver manual
20
CONFIDENTIAL - This document contains condential and privileged information.
The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L.
Read the following instructions carefully before installing the product and keep
this documentaiton for future reference.
General warnings and instructions to ensure the correct operation of the product
in your installation:
1. The installation and use of the product must be done in accordance with the
instructions included in this document.
2. Correct operation of the unit is the client’s responsability. SALTO is not responsible
for any damages resultign from the incorrect use of the product.
3. If a unit has failed to function correctly and/or has been damaged, please contact
your SALTO dealer and do not try to repair and reinstall the unit yourself.
4. This device should be used only in indoor environments.
This manual suits for next models
2
Table of contents