Starmatrix Clever-Pool/220V Owner's manual

CLEVER-POOL ENERGY SAVER
ACCORDING TO:EN61800-5-1:2007
Designed by STARMATRIX GROUP INC.,
Installation, Operation & Maintanence Instructions
Read this manual carefully before commencing installation
WWW.STARMATRIX.CN
Please leave this instruction booklet with the owner as it contains important maintanence and safty information.
- 1 -

4.1 BUTTON AND FUCNTION EXPLANATION …………………………………………………………………………………13
CONTENTS
1. SAFTY AND CAUTION
1.1 READING BEFORE INSTALLATION………………..………………………………………..…………………………………3
1.2 PRODUCT CHECK BEFORE INSTALLATION ……………..………………………………..………………………………..4
1.3 ENVIROMENT CAUTION ………………………………………………..………………..……………………………………...5
2.1 DIMENSION AND TECHNICAL PARAMETERS………………………………………..………………………………………6
3.1 INSTALLATION ………………………………………..………………………………………………………………………...…7
3.1.1 INSTALLATION SKETCH AND DESCRIPTION………………………………………………………………………….7
3.2 WIRE CONNECTION ……………..……………………………………………………………………………………………… 8
3.2.1 WIRE CONNECTION AND DESCRIPTION FOR 2HP AC220V SINGLE PHASE IN - SINGLE PHASE OUT….….8
3.2.2 WIRE CONNECTION AND DESCRIPTION FOR 3HP AC220V SINGLE PHASE IN - THREE PHASE OUT….….9
3.2.3 WIRE CONNECTION AND DESCRIPTION FOR 5HP AC380V THREE PHASE IN - THREE PHASE OUT….….10
3.3 RUNNING ………………………………………...……………………………………………………………………………. 10
3.3.1 CHECK BEFORE RUNNING………………………………………………………………………………………………10
3.3.2 PROGRAMMING GUIDE …………………………………………………………………………………………………..11
2. PRODUCT DIMENSION AND PARAMETERS
3. INSTALLATION AND FUNCTION EXPLANATION
4. BUTTON AND FUCNTION EXPLANATION
- 2 -

DANGER
1. SAFTY AND CAUTION
1.1 READING BEFORE INSTALLATION
Clever-Pool uses vector frequency technology and is a highly precious electronic device, to ensure for personal and
property safty, please read carefully this instruction before using.
There are marks【DANGER】or【CAUTION】in this book,please strictly obey when moving,installing,using or
checking the product.
1、Please make sure to use the correct power supply.
2、Please make sure to close the control panel before power connection to avoid eletricity shock or
explosion
3、Please make sure not to confuse the input and output terminals.
5、Please DO NOT touch the wire terminals when power is connected.
7、Please DO NOT use wet hands for operation.
6、Please wait after 10 minutes after the power is cut off when all the indication lights are off for further
maintanence.
8、Please ask for professional help if you need to change any parts, strictly forbidden to leave any metal
things inside our Clever-Pool.
4、If our Clever-Pool is stocked over 2 years, please use a voltage adjuster to increase the voltage
gradually when power connection.
- 3 -

CAUTION
3、Power connection is required after control panel closed,electricity shock will occure if against this rule.
9、Please stock our Clever-Pool in a dry,ventilated and cool place.
1.2 PRODUCT CHECK BEFORE INSTALLATION
Each Clever-Pool is 100% tested before factory delivery, you need to check by yourself below:
⑴If our Clever-Pool is the right model you ordered.
⑵Any damage caused by transportation, if yes please do not connect to power supply.
5、Do not disconnect the wire connection if power is connected, serious personal damage will occure if
against this rule.
8、Make sure air ventilation when in summer or high ambient temperature use,this will avoid
condensate water formed and electrical faulty.
1. SAFTY AND CAUTION
1、Installation based on local safty rules.
2、Only professionals for installation and maintanence.
4、Do not touch the terminals,electricity shock will occure if against this rule.
6、Do not touch CMOS elements.
7、No voltage duration test allowed for our Clever-Pool, it will get semiconductor elements damaged.
- 4 -

→No corrosive fluid →No dust or metal scraps
→Away from radioactive or flammable substances →No electromagnetic interference
→No rain drops or wet enviroment
1. SAFTY AND CAUTION
1.3 ENVIROMENT CAUTION
The correct enviroment for our Clever-Pool determines its right function and life. So the installation must obey below:
→Indoor use →Ambient temperature:-10℃~+40℃
→No direct sunshine →No oil or salt
- 5 -

Item Model
Clever-
Pool/220V
Clever-Pool
M/220V
Clever-Pool/380V
Input power Single-phase AC Single-phase AC Three-phase AC
Input voltage 220V±15% 220V±15% 380V±15%
Input frequency 50/60Hz 50/60Hz 50/60Hz
Output voltage
1~220V 3~220V 3~380V
PUMP TYPE SINGLE-PHASE THREE-PHASE THREE-PHASE
Max.Power MAX 2HP MAX 3HP MAX 5HP
Max current 12A 10A 10A
Mode option
Cooling
2. DIMENSION AND PARAMETERS
Motor speed
range
2.1 DIMENSION AND TECHNICAL PARAMETERS
Dimension
PARAMETER SHEET
50Hz:1200~3000rpm
60Hz:1200~3600rpm
Manual or Auto
By air
- 6 -

1. Use a cross screwdriver to take
off the screws as shown 3 and plate 1
3.1 INSTALLATION
3.1.1 INSTALLATION SKETCH AND DESCRIPTION
Sketch for Installation
Procedure and instruction
and use screws as shown 2 to fix
3. INSTALLATION AND FUNCTION EXPLANATION
power supply socket.
6、Strictly follow the operation
steps as indicated in this manual.
2、Put plate 1 in your installation place
plate 1.
3、Put the control box 4 on plate 1
and fix with screws as shown 3
4、Connect the plug from pump to the part
as shown 6.
5、Connect plug 5 as shown to the correct
- 7 -

3.2 WIRE CONNECTION
Wires has been preconnected before factory delivery as per request, if you need to
re-connect the wires, please pay attention as below:
3.2.1 WIRE CONNECTION AND DESCRIPTION FOR 2HP AC220V SINGLE PHASE IN - SINGLE PHASE OUT
WIRE CONNECTION SKETCH
Procedure and instruction
3. INSTALLATION AND FUNCTION EXPLANATION
9.Power supply connected only after the
control panel is fixed,
1.Disconnect power before opening the control panel.
2.Make sure no connection between PE,N,L1 termials and
U,V terminals.
3.Wire connection operated only when power disconnected.
4.Check if the input voltage from the power supply is
compliance with clever-pool.
5.No voltage duration test
6.Screw torque for terminal screws more than 1.7N.m
7.Ground link must be connected before operation.
8.Must use the copper wires over 3G1.5mm2
- 8 -

3. INSTALLATION AND FUNCTION EXPLANATION
3.2.2 WIRE CONNECTION AND DESCRIPTION FOR 3HP AC220V SINGLE PHASE IN - THREE PHASE OUT
WIRE CONNECTION SKETCH
3.Wire connection operated only when power disconnected.
4.Check if the input voltage from the power supply is
compliance with clever-pool.
5.No voltage duration test
6.Screw torque for terminal screws more than 1.7N.m
7.Ground link must be connected before operation.
8.Must use the copper wires over 3G2.0mm2
9.Power supply connected only after the
control panel is fixed,
Procedure and instruction
1.Disconnect power before opening the control panel.
2.Make sure no connection between PE,N,L1 termials and
U,V,W terminals.
- 9 -

8.Must use the copper wires over 4G2.0mm2
9.Power supply connected only after the
control panel is fixed,
2.Check if any metal substances left in the product.
3.Check if wire terminals are well tightened.
4.Check if there are naked wires on the terminals touching other terminals.
3.2.3 WIRE CONNECTION AND DESCRIPTION FOR 5HP AC380V THREE PHASE IN - THREE PHASE OUT
WIRE CONNECTION SKETCH
Procedure and instruction
1.Disconnect power before opening the control panel.
2.Make sure no connection between PE,T,S,R termials and
U,V W terminals.
3.Wire connection operated only when power disconnected.
4.Check if the input voltage from the power supply is
compliance with clever-pool.
5.No voltage duration test
6.Screw torque for terminal screws more than 1.7N.m
7.Ground link must be connected before operation.
3. INSTALLATION AND FUNCTION EXPLANATION
3.3 RUNNING AND OPERATION
3.3.1 BEFORE RUNNING AND OPERATION
1.Check if installation and wire connection is 100% correct.
- 10 -
This manual suits for next models
2
Table of contents
Other Starmatrix Audio & Video Accessories manuals
Popular Audio & Video Accessories manuals by other brands

Yamaha
Yamaha PTB-4210 installation instructions

Burst Electronics
Burst Electronics MCG-2 manual

Panasonic
Panasonic DMP-BD60 - Blu-Ray Disc Player installation manual

P3 International
P3 International Kill A Watt operating instructions

Bluetti
Bluetti EP900 user manual

South-Tek Systems
South-Tek Systems Quick-Check 10 manual