LED AND DIAGNOSTIC INDICATORS
LED DESCRIPTION
S.V. ON
(1)
Led on indicates that the solenoid valve
controlled by the units is open. In normal
standby state, this LED should not be on.
BY-PASS
(2)
Led on indicates that the solenoid valve
controlled by the unit is open due to
manual operation by the supervisor. In
normal operating state, this LED must
be off.
ONLINE
(3)
Led on indicates that the device is
correctly connected to the installation.
E.O.L
(4)
Led on indicates that the terminating
resistor is activated.
In the “standby” mode, the firmware version installed on
the unit and the supply voltage are displayed on the
screen by pressing the “SET” or “ENTER” button.
PAIRING WITH A U·VISION UNIT
This unit is equipped with a wireless connection so that it can be paired with a U·Vision or U·Vision+ gun.
Consult the U·Vision instruction manual for further information.
1 2 3 4
CONFIGURATION MENU
Once the unit is connected, follow the next procedure to access the configuration menu:
1. To Access the configuration menu, press and hold both the SET and ENTER buttons simultaneously until the display
shows “LOCAL SETUP”
2. Then, “ADD” is displayed on the screen to indicate that the local address can be set. Automatically a counter is
displayed. The count is incremented from one to 126. When the desired address number is displayed, press ENTER
to confirm the number. If you want to reset the counter, press SET.
3. Once the address is confirmed, “E.O.L” is displayed on the screen to set the end of line resistor. “ON” (led “E.O.L”
on) or “OFF” (led “EOL” off) is displayed according to the last saved status. To change the status, press the “SET”
button and then press ENTER to confirm.
4. “MODE” is displayed on the screen to set the display mode during a transaction. To change the mode, press SET
until the desired mode, “STD” (standard) or “XXL” are displayed. Once the mode is set, press “ENTER” to confirm.
5. “OK!” is displayed on the screen and the unit restarts showing the standby screen.
INSTALLATION AND CONFIGURATION