Samson 5007-2 Series Service manual

Translation of original instructions
EB 9511 EN
Firmware version 1.03.11
Edition January 2021
SAM Connect Gateway (Type5007-2)

Note on these mounting and operating instructions
These mounting and operating instructions assist you in mounting and operating the device
safely. The instructions are binding for handling SAMSON devices. The images shown in
these instructions are for illustration purposes only. The actual product may vary.
ÎFor the safe and proper use of these instructions, read them carefully and keep them for
later reference.
ÎIf you have any questions about these instructions, contact SAMSON‘s After-sales Service
(aftersalesservice@samsongroup.com).
Documents relating to the device, such as the mounting and operating
instructions, are available on our website at www.samsongroup.com >
Service & Support > Downloads > Documentation.
Denition of signal words
Hazardous situations which, if not avoided,
will result in death or serious injury
Hazardous situations which, if not avoided,
could result in death or serious injury
Property damage message or malfunction
Additional information
Recommended action
DANGER
!
WARNING
!
NOTICE
!
Note
Tip
EB 9511 EN

Contents
EB 9511 EN
1 Safety instructions and measures ................................................................1-1
1.1 Notes on possible property damage.............................................................1-3
2 Markings on the device ..............................................................................2-1
2.1 Nameplate .................................................................................................2-1
2.2 Firmware versions.......................................................................................2-2
2.3 Article code................................................................................................2-3
3 Design and principle of operation ...............................................................3-1
3.1 CongurationusingtheTROVIS-VIEWsoftware ............................................3-4
3.2 Versions .....................................................................................................3-4
3.3 Device overview and operating controls........................................................3-4
3.4 Option modules..........................................................................................3-6
3.5 Power supply unit with standby power supply (SPS) .......................................3-6
3.6 Technical data ............................................................................................3-7
3.7 Dimensions in mm.....................................................................................3-10
3.7.1 Dimensions for mounting (mm)...................................................................3-11
4 Shipment and on-site transport ...................................................................4-1
4.1 Accepting the delivered goods .....................................................................4-1
4.2 RemovingthepackagingfromtheSAMConnectGatewayandmodules .........4-1
4.3 TransportingtheSAMConnectGateway.......................................................4-1
4.4 Storing the gateway....................................................................................4-1
5 Installation.................................................................................................5-1
5.1 Installation conditions..................................................................................5-1
5.2 Preparation for installation...........................................................................5-1
5.3 Setting up the optional additional functions...................................................5-1
5.3.1 Inserting option modules..............................................................................5-2
5.3.2 Setting up the standby power supply (SPS)....................................................5-4
5.4 MountingtheSAMConnectGateway...........................................................5-6
5.5 Establishingelectricalconnections ................................................................5-6
6 Operation..................................................................................................6-1
6.1 Capacitive keys...........................................................................................6-1
6.2 Display ......................................................................................................6-2
7 Start-up and conguration..........................................................................7-1
7.1 Settings ......................................................................................................7-2
7.1.1 Setting the user level....................................................................................7-2
7.1.2 Setting the language ...................................................................................7-3
7.1.3 Activating password protection ....................................................................7-3

Contents
EB 9511 EN
7.1.4 Setting the local power line frequency...........................................................7-4
7.1.5 Performing option module settings................................................................7-4
8 Operation..................................................................................................8-1
8.1 Remotedatatransmission ............................................................................8-1
8.1.1 StatusLEDsoftheGSMmodule....................................................................8-1
8.1.2 Improving the signal quality.........................................................................8-1
9 Malfunctions ..............................................................................................9-1
9.1 Troubleshooting ..........................................................................................9-1
10 Servicing..................................................................................................10-1
10.1 Firmware updates .....................................................................................10-1
10.2 Periodic inspection and testing of the gateway.............................................10-1
11 Decommissioning .....................................................................................11-1
12 Removal ..................................................................................................12-1
12.1 Removingtheoptionmodule......................................................................12-1
12.2 Removingthegateway ..............................................................................12-1
13 Repairs ....................................................................................................13-1
13.1 ReturningdevicestoSAMSON ..................................................................13-1
14 Disposal...................................................................................................14-1
15 Certicates...............................................................................................15-1
16 Annex A (conguration instructions)..........................................................16-1
17 Annex B...................................................................................................17-1
17.1 Accessories ..............................................................................................17-1
17.2 After-sales service.....................................................................................17-1

EB 9511 EN 1-1
Safety instructions and measures
1 Safety instructions and measures
Intended use
ThemodularSAMConnectGatewayallowstheinputofsignals(4to20mA),forexample
issuedbyexternaltransmitters.Furthermore,theintegratedGSMmoduleallowsremotedata
transmission.
Thedeviceisdesignedtooperateunderexactlydenedconditions(e.g.supplyvoltage,
temperature). Therefore, operators must ensure that the device is only used in operating
conditionsthatmeetthespecicationsusedforsizingthedeviceattheorderingstage.
SAMSON does not assume any liability for damage resulting from the failure to use the
deviceforitsintendedpurposeorfordamagecausedbyexternalforcesoranyother
externalfactors.
ÎRefertothetechnicaldataforlimitsandeldsofapplicationaswellaspossibleuses.
Reasonably foreseeable misuse
TheSAMConnectGatewayisnot suitable for the following applications:
−Useoutsidethelimitsdenedduringsizingandbythetechnicaldata
Furthermore, the following activities do not comply with the intended use:
−Use of non-original spare parts
−Performing maintenance activities not described in these instructions
Qualications of operating personnel
Thedevicemustbemounted,startedupandservicedbyfullytrainedandqualiedpersonnel
only; the accepted industry codes and practices are to be observed. According to these
mounting and operating instructions, trained personnel refers to individuals who are able to
judgetheworktheyareassignedtoandrecognizepossiblehazardsduetotheirspecialized
training,theirknowledgeandexperienceaswellastheirknowledgeoftheapplicable
standards.
Personal protective equipment
No personal protective equipment is required for the direct handling of the SAM Connect
Gateway.Workintheplantmaybenecessarythatrequirespersonalprotectiveequipment.
ÎCheck with the plant operator for details on personal protective equipment.

1-2 EB 9511 EN
Safety instructions and measures
Revisions and other modications
Revisions,conversionsorothermodicationsoftheproductarenotauthorizedbySAMSON.
Theyareperformedattheuser'sownriskandmayleadtosafetyhazards,forexample.Fur-
thermore, the product may no longer meet the requirements for its intended use. Use of the
device is no longer permitted in this case.
Warning against residual hazards
To avoid personal injury or property damage, operators and operating personnel must pre-
venthazardsthatcouldbecausedinthedevicebytakingappropriateprecautions.Plantop-
eratorsandoperatingpersonnelmustobserveallhazardstatements,warningandcaution
notes in these mounting and operating instructions, especially for installation, start-up and
service work.
Responsibilities of the operator
Operators are responsible for proper use and compliance with the safety regulations. Opera-
tors are obliged to provide these mounting and operating instructions to the operating per-
sonnel and to instruct them in proper operation. Furthermore, operators must ensure that op-
eratingpersonnelorthirdpartiesarenotexposedtoanydanger.
Responsibilities of operating personnel
Operating personnel must read and understand these mounting and operating instructions as
wellasthespeciedhazardstatements,warningandcautionnotes.Furthermore,theoperat-
ing personnel must be familiar with the applicable health, safety and accident prevention
regulations and comply with them.
Referenced standards, directives and regulations
DeviceswithaCEmarkingfullltherequirementsoftheDirectives2014/53/EUand
2011/65/EU.
The'Certicates'sectioncontainsthisdeclarationofconformity.
Referenced documentation
The following documents apply in addition to these mounting and operating instructions:
−OperatingInstructions(SAMConnectGateway–CongurationwithTROVIS-VIEW)
uEB9511-2
−Mountingandoperatinginstructionsforconnectedcomponents(Media5,Media6)

EB 9511 EN 1-3
Safety instructions and measures
1.1 Notes on possible property damage
NOTICE
!
Risk of fatal injury due to electric shock (230V version).
ÎBeforeconnectingwiring,performinganyworkonthedeviceoropeningthede-
vice, disconnect the voltage supply and protect it against unintentional reconnection.
ÎOnly use power interruption devices that are protected against unintentional recon-
nection of the power supply.
Risk of damage to the electronics due to the incorrect connection of the electrical
power supply.
TheSAMConnectGatewayisdesignedtooperateunderexactlydenedelectricalcon-
ditions.
ÎObserve the permissible tolerances of the supply voltage.
ÎFor wiring, you are required to observe the relevant regulations concerning device
safety and electromagnetic compatibility.
Risk of damage to the device due to incorrect mounting position.
ÎMount the device in the upright position only.
Incorrect installation and removal of option modules will damage the SAM Connect
Gateway.
ÎBeforeinsertingorremovingtheoptionmodules,disconnectthesupplyvoltage.
Risk of malfunction due to incorrect power line frequency setting.
Thelocalpowerlinefrequencymustbeenteredtobeabletoproperlylteroutanydis-
turbanceswhicharetransmittedovergroundwiresorexternalpowersupplyunits.
ÎSet the local power line frequency by selecting the corresponding parameters.
The use of unapproved batteries will damage the SAM Connect Gateway.
ÎDonotuserechargeablebatteriesintheSAMConnectGateway.
Risk of device damage due to foreign particles entering it.
ÎDonotremovethepackagingandprotectivelm/protectivecapsuntilimmediately
before mounting and start-up.

1-4 EB 9511 EN

EB 9511 EN 2-1
Markings on the device
2 Markings on the device
2.1 Nameplate
1 Signal range
2Electricpowersupply
3 Model number
4 Firmware version
5CongurationID
6 Serial number1)
SAMSON 5007 - 2
SAMSON AG, Germany
Made in Germany
Output Supply
Model 5007 -
SAM Connect Gateway
See technical data for ambient temperature
Firmware
Serial no.
Var.-ID
1 2
3
4
5
6
1) Thersttwoguresoftheserialnumberinreverseorderindicatetheyearof
manufacture(example:serialnumber71xxxxxÎYear of manufacture = 2017).
2) 15-digitserialnumberforuniqueidenticationofmobiledevices
2
SAMSON 5007-1 Option module [GSM]
IMEI:
Activation-Code:
GSM Module
Model
1
4
3
1InternationalMobileEquipmentIdentity1)
2 Model number
3 Activation code
4QRcode
GSM module:
SAMSON 5007 Option module
2
1
Option module:
1 Abbreviation of optional additional function
2 Optional additional function

2-2 EB 9511 EN
Markings on the device
2.2 Firmware versions
Firmware revisions
Old New
1.02.07 1.03.09
• Newversion:230Vversion
• Increased measuring accuracy of the analog inputs
• RussianandTurkishaddedasmenuanddisplaylanguage
• Start-upwizardadded
• Improved operation
• Four-gurecodetoprotectthegatewaysettings
1.03.09 1.03.11
Internal revisions

EB 9511 EN 2-3
Markings on the device
2.3 Article code
SAM Connect Gateway 5007-2- 0 0 0 xxxxxx0x000xxxxxx
Power supply
Powersupplyunit,18to36VDC 1
Powersupplyunit,100to230VAC 2
Option module slot 1
AI: Analog input 4
AIA: Analog input active 6
Option module slot 2
Without 0
AI: Analog input 4
AIA: Analog input active 6
Option module slot 3
Without 0
AI: Analog input 4
AIA: Analog input active 6
Option module slot 4
Without 0
AI: Analog input 4
AIA: Analog input active 6
GSMmodule
GSMmodulewithantenna(includingSIMcard) 2
Housing material
Plastic 0
Version
Standard 0 0
Hardware version
Index:00 9 9

2-4 EB 9511 EN

EB 9511 EN 3-1
Design and principle of operation
3 Design and principle of oper-
ation
ThemodularSAMConnectGatewayallows
theinputofsignals(4to20mA),forexam-
pleissuedbyexternaltransmitters.Forthis
purpose,fourslotsexistinthedevicetohold
option modules that can optionally be used
for the AI (analog input)and/orAIA (ana-
log input active) option modules.
At least one option module must always be
installed in the SAM Connect Gateway. See
section3.4 for details on the option mod-
ules.
Furthermore,theintegratedGSMmoduleal-
lows remote data transmission and connec-
tiontotheSAMTANKMANAGEMENTweb
portal.
Application
TheSAMConnectGatewaycanacceptupto
four4to20mAsignalsandtransferthe
dataovertheintegratedGSMmodule.Asa
result, transmitters installed in a plant (e.g.
Media5,Media6and/orothertransmitters
by other manufacturers) can be connected to
theSAMTANKMANAGEMENTweb
interface.Thisallowsthellinglevelsofup
tofourtanks(Fig.3-2)orthellingleveland
pressureoftwotanks(Fig.3-3)tobelogged
and managed on the SAM TANK
MANAGEMENTinterface.
Note
1 Microcontroller
2 Data memory
3 Operating keys
4 Depending on version:
24Vor230Vpowersupply
unit
5 Display
6 Serial interface
7 Depending on version:
UB=24to36Vor
UB=100to230V
8GSMmodule
9 Option module (up to 4)
9
2
1
3
4
5
EEPROM
µC
7
6
GSM
=
=
8
Fig.3-1: Block diagram of SAM Connect Gateway

3-2 EB 9511 EN
Design and principle of operation
Filling levels of four tanks are transferred to the gateway.
Media 5
Media 5
Media 6
Media 6
WWW
SAM TANK
MANAGEMENT
Fig.3-2: Sample application 1 of the SAM Connect Gateway

EB 9511 EN 3-3
Design and principle of operation
Filling levels and absolute pressures of two tanks are
transferred to the gateway.
Media 6
WWW
SAM TANK
MANAGEMENT
Media 6
Fig.3-3: Sample application 2 of the SAM Connect Gateway

3-4 EB 9511 EN
Design and principle of operation
Operation
Four capacitive keys are used to operate the
SAMConnectGatewayandallowtheuser
to navigate within the menu on the display.
3.1 Conguration using the
TROVIS-VIEW software
TheSAMConnectGatewaycanbecong-
uredwithSAMSON'sTROVIS-VIEWSoft-
ware(version4).Forthispurpose,thegate-
way has a digital interface (SSP) to allow the
USBportofacomputertobeconnectedtoit
using an adapter cable (order no. 1400-
9740).
TheTROVIS-VIEWsoftwareenablestheuser
toeasilycongurethegatewayaswellas
view process parameters online.
TROVIS-VIEW can be downloaded free of
charge from our website at www.sam-
songroup.com > Service & Support > Down-
loads > TROVIS-VIEW.
3.2 Versions
24V version (Type5007-2-0001…)
−Inputvoltage:24to36VDC
−Operatingtemperature:–40to+70°C
230V version (Type5007-2-0002…)
−Input voltage:
100to230V/50Hz
100to110V/60Hz
−Operatingtemperature:–20to+70°C
3.3 Device overview and
operating controls
ÎSeeFig.3-4
1 Display
2Conrmkey
3 Up arrow key
4 Down arrow key
5Backkey
6ErrorLED
7BatteryLED(SPS)
8StatusLEDsforGSMmodule
9 Terminal to connect the supply voltage
10 GSMmodule
11 SSP interface
12 Slots 1 to 4 for option modules
13 SPS: standby power supply
14 Groundingconnection
Note

EB 9511 EN 3-5
Design and principle of operation
9
12
12
11
10
12
12
13
14
1
6
8
8
72
3
4
5
Fig.3-4: Operating controls

3-6 EB 9511 EN
Design and principle of operation
3.4 Option modules
The gateway provides analog inputs through
the use of option modules to accept (4 to
20mA)analogsignalsfromllinglevelor
pressuresensorsofexternalequipment.Four
slots are available in the device.
UpondeliveryoftheSAMConnectGate-
way, at least one option module is installed.
Furtheroptionmodulescanberetrotted.
The following option modules are available:
−AI: Analog input
This module works passively and has
galvanically isolated inputs. It can accept
signals from devices with their own pow-
er supply.
−AIA: Analog input active
This AIA (analog input active) option
moduleworksactivelyandhasa12V
outputtopowerexternalequipmentthat
do not have their own power supply.
3.5 Power supply unit with
standby power supply
(SPS)
The power supply units include a battery
compartmentfora1.5Vbatterywhichpro-
vides standby power supply upon power
failure.

EB 9511 EN 3-7
Design and principle of operation
3.6 Technical data
Table 3-1: General technical data
SAM Connect Gateway
Mounting orientation Upright with display facing sideways
Display
Display LCD128x64(90x40mm)
Storage temperature –40toapprox.+80°C
Operating temperature 24Vversion:–40to+70°C
230Vversion:–20to+70°C1)
Environmental inuences
StorageaccordingtoEN60721-
3-1 (long-term storage)
1K5(airtemperature–40to+80°C);1M3
(ThefollowingrestrictionappliestoGSMmodule:airtemperatures–30to
+75°C)
Transportation according to
EN60721-3-2
2K4(airtemperature–40to+40°Cinventilatedenclosures,upto+70°Cin
unventilated enclosures), 2M1
(ThefollowingrestrictionappliestoGSMmoduleforlowairtemperaturesdown
to–30°C)
Operation according to
EN60721-3-4
(stationary use at non-weath-
er-protected locations)
4K4(withrestrictions:airtemperature–40to+55°C,temperatureinsidethe
housingmustnotexceed+70°Cwhenexposedtodirectsunlight);4M4
ThedisplayandGSMmoduleareheatedatlowairtemperatures.
Mechanical vibration
Vibrations(sinusoidal)according
toIEC60068-2-6
2to9Hz;3.5mmamplitude
9to200Hz;10m/s²acceleration
200to500Hz;15m/s²acceleration
Randomandguidancevibration
accordingtoIEC60068-2-64
1.0m²/s³;10to200Hz
0.3m²/s³;200to2000Hz
ShocksaccordingtoIEC60068-
2-27 Acceleration100m/s²;duration11ms
Requirements
EMC DeviceswithaCEmarkingfullltherequirementsoftheDirective2014/30/EU.
CompliancewithEN61000-6-2,EN61000-6-3andEN61326-1.
Degree of protection IP67accordingtoIEC60529(VDE470Part1,2014-09)
Electrical connections
Cable glands M16x1.5(max.5)
Terminals 0.2to2.5mm²wirecross-section
Spring-cage terminals (option
modules) 0.13to1.5mm²wirecross-section

3-8 EB 9511 EN
Design and principle of operation
Communication
Local SAMSONSSPinterfaceandserialinterfaceadapter,TROVIS-VIEW
Remotedatatransmission GSMmodule
Weight
Device (with 4 option modules) Approx.1400g
1) Impaired operation and readability may arise outside the temperature range.
Measurementisnotinuencedintherangebetween–40and+70°C.
Table 3-2: Power supply
24V version
Input voltage 24to36VDC
Output voltage 12VDC
Power 24W
Version Reversepolarityprotection
230V version
Input voltage 100to230V/50Hz·100to110V/60Hz
Output voltage 14VDC
Power Max.10W
Table 3-3: Optional additional functions
AI: Analog input
Version 4to20mAcurrentinput,externallypowered,galvanicallyisolated,reversepolarity
protection
Load impedance ≤5.0Vexternal(correspondingto≤200Ωat20mA)
Measuring range 0.1to21.6mA
Accuracy ≤1.0%
Resolution 20µA
Effectoftemperature 0.3%/10K
Static destruction limit 38VDC·30VAC
AIA: Analog input active
Version 4to20mAcurrentinput,internallypowered,reversepolarityprotection
Load impedance ≤1Vinternal(correspondsto≤50Ωat20mA)
Output voltage at the
terminal
≥12VDCtopowerexternaltwo-wiredevices
Measuring range 0.1to21.6mA