CHARGING
• Max charge current is 6A. Charge this battery under 6A.
• It is recommended to charge this battery between 10°C and 30°C/ 50°F and 86°F.
• Please use our included D-TAP travel charger or other chargers designed for batteries
that meet the specications of this battery as listed below.
DISCHARGING
• The max total continuous discharging power is 160 watts. The main power is 160
watts max. The D-TAP power is 70 watts max. The USB power is 12.5 watts max.
When the main power is discharging at 160 watts full power, the D-TAP and USB
cannot be used. If the total power exceeds 160 watts, the protective circuit will be
activated and it will stop discharging and may cause damage to the battery. If the fuse
is blown due to an overload, the battery will not recover.
• The battery life may diminish if high loads are applied frequently.
• Battery run time may be reduced in extreme high and low temperature. It is
highly recommended to use the battery in ambient temperature of 10°C-40°C/
50°F-104°F.
• The discharge characteristics of this lithium ion battery have a steady discharge curve
until 13v.
• The battery will automatically stop discharging when the voltage reaches 11v. To
extend battery life, we recommended to stop using before the battery reaches 12v.
• Please be sure to remove the battery from the device after use. If the battery is left
mounted on the device that has standby power, the battery will be exhausted.
CAPACITY DISPLAY LEDS
• The remaining battery capacity is displayed with 8 LED bars.
• Press the check button and the LED bars will illuminate. The readout will go dark 10
seconds after the button is released to save power.
• When the battery reaches the last bar, it will icker to remind the user to change the
battery. When all LEDs are off, the battery will be exhausted.
• The capacity remaining is based on battery voltage. It varies according to the load, so
it is only for approximate reference.
PROTECTION CIRCUITRY
• There are four types of protective circuits to ensure the battery is protected from over
charge, over discharge, over current and over heat. If the protection fuse is blown, the
battery is no longer operable.
• Please charge the battery immediately when the over discharge protection is
activated. The battery may become unusable if the battery is not charged immediately.
USB
• USB connector for power supply (DC 5V, 2.5A).
• USB power will turn off automatically 10 seconds after the USB cable is removed.
• Do not draw power from USB when charging as it may interrupt charging and cause a
charge error.
• The terminal does not provide data, only power.
• The USB power output will not begin to charge the connected device until the battery
test button is pressed.
D-TAP